Truly Instrument TET-340 Infrared Thermometer User Manual TET 340

Truly Instrument Ltd. Infrared Thermometer TET 340

User Manual Rev.2

This thermometer has a memory for 10 readings. After each reading, the temperature is automatically recorded in the first empty memory.If all the memory space is used, the first memory is automatically deleted and replaced by the new reading and so on. To read the memorised temperatures: The product must be switched off.• Press the button       until    MEMORY appears on the screen.    The information appears on the   screen alternately.   example :• To read all of the 10 temperature    readings in the memory, press    briefly and successively on       :    the different temperatures are    displayed one after another as    the ear or forehead mode in   which they have been taken.• To exit the memory mode, press    the button       or wait for the    thermometer to switch off   automatically.To delete the memorised temperatures:• Enter in memory mode .• Press       until           appears.   The thermometer switches off  Switching offTo switch the appliance off:Press the button       until the screen displays OFF. Or the appliance switches off automatically after 60 seconds.Memory functionInfrared Ear & Forehead ThermometerMODEL: TET-340User ManualRev.00    2011/06/14MANUFACTURER: Truly Instrument Ltd.                                   2/F.,                                    Chung Shun Knitting Centre,                                   1-3 Wing Yip St, Kwai Chung,                                     N.T., HONG KONGTEL: (852) 2487 9803FAX: (852) 2146 5756, 2480 0018, 2480 0126EC-REPRESENTATIVE: Wellkang Ltd t/a Wellkang Tech Consulting Suite B,29 Harley Street, LONDON W1G 9QR, United Kingdom-1- -2- -3- -4--8--7--6--5-1. Lens2. Probe3. Battery compartment4. Luminous diodes to show     temperature mode : ear or     forehead5. Screen6. Take temperature and     memory function button7. On/Off and Ear or forehead     temperature Mode button8. Protection/vertical storage cap.   DescriptionPrecautions for useThis ear and forehead thermometer receives the infra-red rays emitted by the skin’s surface and in the ear drum area. It allows you to check your child’s temperature easily. This is how to use the appliance:• TET-340 is exclusively dedicated    to take ear or forehead    temperatures. We would like to    re-iterate that this appliance does    not replace the advice of a doctor.    In case of doubt or fever, contact    your doctor.    The simple take of temperature    cannot be considered as a    medical advice, DO NOT modify    the proportion of any drugs    prescribed by your doctor without    seeking medical advice first.• To ensure the reading is accurate,    the probe and the lens must be    absolutely clean.• Do not use the thermometer if it    has been dropped or shows any   signs of damage.• Always place the protection cap    back after use.• In cases of movement from one     Warning, this appliance is not suitable for detecting  hypothermia.Average temperatures   room to another, wait for half an    hour minimum before using the    appliance.• Wait for half an hour after    physical training, bathing or    eating before measuring    temperature.• Keep the thermometer out of    reach of children.• Do not expose the thermometer:   - To any warm sources (radiator,      sun rays, ...)   - To dust or humidity.• Never immerse the thermometer    in liquid.• Do not touch the lens with your    fingers.BODY TEMPERATURE: the normal human body temperature varies during the day. It is measuredalong a scale of values defined according to the part of the body where the temperature is taken:   - Rectal measurement:      36,6°- 37,8°C   - Axillary measurement      (under the arm): 34,7°- 37,3°C   - Oral measurement (in the      mouth) or forehead:      35,5°- 37,5°C   - Ear measurement:      35,8°- 37,8°CForehead temperatureEar temperatureRectal temperatureOral temperatureAxillary temperature36.1°C36.4°C37.0°C36.6°C36.1°CTechnical specificationsComments: these technical specifications may be subject to modifications to improve the appliance, without prior warning.Installing the batteryThe appliance is delivered with a lithium battery 3V (CR2032) already in place. At the first use, open the battery cover then remove the strip which ensures the protection of the battery (fig. 1/fig. 2). Replace the cover (fig. 3).Installing the battery, Open the battery compartment and place a new button lithium battery CR2032 3 volts polarity + on the top. Replace the cover. Keep the battery out of reach of children.IMPORTANT: When installing a newbattery. always wait half hour an hour before using the appliance.Screen resolution 0.1°CMeasurement range  20°C - 42.2°CPrecision 32°C ~ 42°C: +/-0.2°C<32°C and >42°C+/-0.3°COperation conditions-room temperature+16°C / + 35°C Relative humidity less than 85%Storage conditions -20°C / +80°C Relative humidity less than 95%Energy source  1 lithium battery 3V type CR2032 Service life: approximately 5000 measuresAs for all thermometers, slight variations in temperature may be displayed one after another:it is therefore recommended to take several readings (removing the thermometer from the ear between each reading) and take the highest reading into account.Forehead measurement• Remove the protection cap.• To switch on press and maintain    the button        until the    indications in fig. 4 are displayed   in the screen the appliance comes    automatically displays the Ear    mode.• Press the button       to select the    forehead mode. The screen    shows the corresponding    function fig. 7 and the luminous    diode corresponding to the    symbol        blink 5 times.• Place the probe in the middle of    the forehead. Press the button         . Slowly slide the probe on   the skin to the temple fig. 8. • While taking the temperature, the    screen indicates          and audible    bips sound.• As soon as the probe is placed on    the area of the temple, release    the button       , wait for the   validation sound beep before    removing the thermometer.• Read the temperature on the    screen.• The temperature is automatically    recorded.Notice:This temperature reading must be considered as an estimation.The temperature reading of the forehead can be influence by environmental conditionsbecause the probe is more sensitive to perspiration, sebum, physical activity and environmental temperature.It is recommended that you wipe the forehead before taking areading. In case of importantdifferences or if in any doubt, theear measurement must be pointedEar measurement• Remove the protection cap.• To switch on press and hold the    button        until the indications    in fig. 4 are displayed in the    screen the appliance automatically    displays the Ear mode. The screen    shows the corresponding function    fig. 5 and the luminous diode    corresponding to the symbol             blink 5 times.• Gently pull the ear upwards and    backwards to straighten the ear    canal. Insert the thermometer into    the ear canal fig. 6.• While continuing to hold the ear,    press       . During the taking of    temperature, the screen indicates              .• Wait for the validation sound    beep before releasing the button    and removing the thermometer.• Read the temperature on the    screen.• The temperature is automatically   recorded.Specific messagesSpecific messagesNotice:• For optimal precision, the ear    should not be obstructed by wax    or a plug.• Do not use this thermometer with    an ear infection (otitis). Moreover,    if your child has had several ear    infections, the measurement will    be less accurate. out. We remind you that there is a significant difference between an ear temperature reading and a forehead temperature reading. automatically.  The ear and forehead thermometer has been designed to give precise information. If the following messages appear on the screen, refer to the table below and follow the instructions : Battery energy is low.The battery is dead.The temperature reading exceeds the range of possible temperatures.The temperature reading is below the range of possible temperatures.The temperature reading is out the range of possible temperatures.Change the battery. If the screen remainswhite, contact a TRULY after sales servicecenter.Change the battery.Take the temperature reading again.Take the temperature reading again.Place the thermometer in a room wherethe temperature is between 16°C and 35°C and wait at least 30 minutes before taking the temperature again.81234567fig. 2fig. 1fig. 8fig. 3fig. 6fig. 5fig. 4fig. 7clean the body of the thermometer using a soft cloth; The probe can be cleaned with cotton soaked in disinfectant; The lens can be cleaned with cotton gently soaked in disinfectant.
FCC Caution.   § 15.19 Labelling requirements. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. If the labelling area is considered too small and therefore it is impractical (smaller than the palm of the hand) to display the compliance statement, then the statement may be placed in the user manual or product packaging.  § 15.21 Information to user. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.   § 15.105 Information to the user. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help.

Navigation menu