Truly Instrument TET-381 Infrared Thermometer User Manual Rev 2

Truly Instrument Ltd. Infrared Thermometer Rev 2

User Manual Rev.2

Download: Truly Instrument TET-381 Infrared Thermometer User Manual Rev 2
Mirror Download [FCC.gov]Truly Instrument TET-381 Infrared Thermometer User Manual Rev 2
Document ID2359231
Application IDYvv0knljsguR0KexrqwLLw==
Document DescriptionUser Manual Rev.2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize291.81kB (3647648 bits)
Date Submitted2014-08-15 00:00:00
Date Available2014-08-18 00:00:00
Creation Date2014-06-27 11:43:35
Producing SoftwareAdobe PDF library 7.77
Document Lastmod2014-08-08 16:04:59
Document TitleTET-381英文说明书 蓝牙
Document CreatorAdobe Illustrator CS2

Contents
Cautions ..................................................2
Infrared Thermometer
TET-381
Special Features .....................................2
Measurement Principle ...........................2
Product scope .........................................3
The component of product ......................3
Setting .....................................................3
C / OF unit conversion formula ...............4
Method of measurement .........................4
Connect iOS device via Bluetooth ..........5
Memory Function ....................................6
Replacing the Batteries ...........................6
Cleaning and Care ..................................6
Display Message .................................... 7
Product Specifications .............................8
Thank you for purchasing the non-contact
electronic thermometer, Please read through this
manual before using the product.
Cautions
1. Do not drop or shock the unit.
2. Do not immerse the unit into water.
3. Keep the unit out of reach of children.
4. Avoid touching the lens with bare hand.
5. Do not use in areas with strong electromagnetic
interference.
6. Consult your physician if the reading is out of normal
body temperature range.
7. Remove the batteries from the thermometer if the
unit will not be used for an extended period of time.
This will prevent battery leakage causing damage
to the thermometer.
8. If the unit is not working properly, please contact
customer service.
9. Do not disassemble the unit, Open the battery
cover only when replacing batteries.
Connect iOS device via Bluetooth
1. Installation
Prior to first use, Download and install application to
your iOS device. (Bluetooth 4.0 capabilities,
e.g. iPhone 4S, iPhone 5, NewiPad and iPadMini).
2. Open application, and then press the Blood
Pressure icon on Measure screen.
③
④
⑤
⑥
C / OF unit conversion formula
Power/Measure
Method of measurement
Battery cover
Back
Front
Setting
-4-
Display Message
Display
message
Situation
Product specification
Project
Allow the thermometer
remain in room
temperature (10-40OC)
for 30 minutes.
Sensor error
Please contact with the
customer service.
Memory error
Please contact with the
customer service.
Temperature measured
is higher than normal
human temperature
range
(Body above 42.2OC;
Surface above 60OC)
Check the measured
object and take a
new measure.
Temperature measured
is lower than normal
human temperature
range (Body below 32OC;
Body below 20OC)
Check the measured
object and take a
new measure.
Low battery
Replace batteries.
Content
Infrared measuring
Measuring mode
Surface/body temperature
Measuring distance
5~10cm
Measuring
Surrounding
Accuracy
Accuracy
32~42.2OC
16~35OC
±0.3OC
10~40OC
±0.4OC
20~32OC
Solution
Ambient temperature
is out of operating
range (10-40OC)
- 7-
This appliance conforms to the following
standards:
Measuring type
42.2~60OC
Indicator Functions
LCD display
Low voltage tip
<2.2V±0.3
Display resolution
0.1OC
Unit
Work surrounding
10OC~40OC
Storage temperature
-20OC~+50 OC
EN60601-1: Medical electrical equipment Part 1: General
requirements for safety
EN12470-5: Clinical thermometers Part 5: Performance of
infrared ear thermometers (with maximum
device)
93/42/EEC : Medical Device Directive
ASTM E 1965-98: Standard Specification for Infrared
Thermometers for Intermittent
Determination of Patient Temperature
Manufacturer
Rerfer to the instructions
Equipment of BF
Recycling and Processing
C , OF
Automatic shutdown
1 minute after not being used
Memory
50 Group memory
Battery
2 x AA
Size
159×87.5×45.5 mm
Weight
About 98g (Not including batteries)
1. Use a soft, dry cloth to clean the exterior of the
thermometer.
- 6-
1. Pressing "Power" and display.
2. Press "MODE" key to select temperature
measurement mode (body or surface) :
(1) Thermometer is straight to the forehead, and
distance is 5~10cm.
5~10cm
Cleaning and Care
- 5-
F=1.8xOC+32
- 3-
Memory Function
Products use battery by 2, when a battery symbol
appears and flash in the screen, and replace the
battery as soon as possible.
• Note:
1. Open the battery cover to
replace batteries, and
place the battery is the
Pull and open the
battery cover from
location of the negative
then on
electrode correctly.
2. If not use, please take out
the battery so as to
protect instrument.
Cranium
Memory
Mode
- 2-
2. Keep the thermometer away from direct sunlight,
dust and contamination environment.
3. Store the thermometer in normal room
temperature, or within 10-40oC.
4. Don't touch with the finger.
5. Can use less than 75% of the rubbing alcohol to
clean the lens.
Replacing the Batteries
Set
Surface
Measuring the temperature of the body and the
surface on forehead with infrared. Products the same
built-in infrared sensor and related hardware,
software, can sense the analyte, analysis and records
3. Press the “Enter” button.
4. Press the “Thermometer” button.
5. When the measurement is complete, the
temperature will display on Thermometer monitor &
save on iOS application screen.
6. This thermometer stores the last temperature
readings.
1. Pressing "Power" and display and showen the last
records.
2. Pressing the "MEM" key to switch record shows
upper
* LCD display test records and record number.
3. Switch mode
* Pressing the "MODE" key to switch MODE.
LCD
Body
4. Save setting value.
Pressing the "SET" key for 3 seconds to save
the value and exit setting mode. If F-04 value is
"YES", The thermometer will be delete all records.
(2) Pressing and holding the "Measure" key and
move thermometer scaning forehead.
(3) Release the "Measure" key to finish
measurement and display the result on LCD.
(4) Turn off: The thermometer will trun off
automatically without use for 1 minute.
- 1-
• Note:
The correct method of use is the key to test the
accuracy. Please follow these instructions, so as to
avoid the infrared measurement on the surrounding.
1. Testing temperature, as the showing in the figure,
instrument and the distance from the forehead
suggested in 5cm to 10cm.
2. Keep the body's temperature as the same as the
surrounding.
3. It should be avoided cold and any disease of cool
down the temperature.
4. Keep the Instrument's temperature as the same
as the surrounding.
5. Forbidden to use this instrument in the strong
sunshine place.
6. Measure suggestion: 3 times or so, every time
when to display up to a set of data shall prevail.
The component of product
1. Pressing the “SET” Key for 3 seconds, The
thermometer will be turn on and enter the setting
mode, the LCD display F-00 and alarm temperature
value.
2. Modify the setting value
Pressing the "MODE" or "MEM" key to change the
value.
3. Switch to other setting item:
Press the "SET" key to switch to other item.
F-01: Offset value for body mode(-2.0~+2.0).
Measurement Principle
Rev.00 20131023
Product scope
For measurement of body and surface temperature.
Special Features
1. Measurement range: Body: 32~42.2OC / 90~108OF
Surface: 20~60OC / 68~140OF
2. Free to set alarm temperature.
3. Non-contact measurement, avoid cross infection.
4. Memory for 50 readings.
5. Auto power off without use it.
6. Unit of Measure: OC/OF.
7. Backlight.
F-02: Offset value for surface mode(-2.0~+2.0).
F-03: Temperature Unit (OC/OF).
F-04: Delete records(Yes,No)
and environmental temperature, and once the user
has to pass the instrument near certain parts of the
body (forehead), and press the measure button can
immediately active infrared radiation sensor.
- 8-
The european Union flag
IP is short for Ingress Protection which means that
Protection’s level.
FCC Caution.
§ 15.19 Labelling requirements.
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
If the labelling area is considered too small and therefore it is impractical (smaller
than the palm of the hand) to display the compliance statement, then the statement
may be placed in the user manual or product packaging.
§ 15.21 Information to user.
Any Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
§ 15.105 Information to the user.
Note: This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2014:06:27 11:43:35+08:00
Creator                         : Adobe Illustrator CS2
Modify Date                     : 2014:08:08 16:04:59+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Format                          : application/pdf
Title                           : TET-381英文说明书 蓝牙
Creator Tool                    : Adobe Illustrator CS2
Metadata Date                   : 2014:08:08 16:04:59+08:00
Thumbnail Width                 : 256
Thumbnail Height                : 180
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 22621 bytes, use -b option to extract)
Document ID                     : uuid:930B53B2ACFDE3118D349AD792B93430
Instance ID                     : uuid:c40598e3-b998-4fd4-9b3d-630884cabf3a
Derived From Instance ID        : uuid:080d1ae5-68a8-46ef-b17a-c5a1b134d009
Derived From Document ID        : uuid:9AB1EF13A8FDE3118D349AD792B93430
Producer                        : Adobe PDF library 7.77
Page Count                      : 2
For                             : User, -
Bounding Box                    : -1 -2 1135 793
Container Version               : 9
Creator Version                 : 12
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ABG7TET-381

Navigation menu