Truly Instrument TET-381 Infrared Thermometer User Manual Rev 2
Truly Instrument Ltd. Infrared Thermometer Rev 2
User Manual Rev.2
Contents Cautions ..................................................2 Infrared Thermometer TET-381 Special Features .....................................2 Measurement Principle ...........................2 Product scope .........................................3 The component of product ......................3 Setting .....................................................3 C / OF unit conversion formula ...............4 Method of measurement .........................4 Connect iOS device via Bluetooth ..........5 Memory Function ....................................6 Replacing the Batteries ...........................6 Cleaning and Care ..................................6 Display Message .................................... 7 Product Specifications .............................8 Thank you for purchasing the non-contact electronic thermometer, Please read through this manual before using the product. Cautions 1. Do not drop or shock the unit. 2. Do not immerse the unit into water. 3. Keep the unit out of reach of children. 4. Avoid touching the lens with bare hand. 5. Do not use in areas with strong electromagnetic interference. 6. Consult your physician if the reading is out of normal body temperature range. 7. Remove the batteries from the thermometer if the unit will not be used for an extended period of time. This will prevent battery leakage causing damage to the thermometer. 8. If the unit is not working properly, please contact customer service. 9. Do not disassemble the unit, Open the battery cover only when replacing batteries. Connect iOS device via Bluetooth 1. Installation Prior to first use, Download and install application to your iOS device. (Bluetooth 4.0 capabilities, e.g. iPhone 4S, iPhone 5, NewiPad and iPadMini). 2. Open application, and then press the Blood Pressure icon on Measure screen. ③ ④ ⑤ ⑥ C / OF unit conversion formula Power/Measure Method of measurement Battery cover Back Front Setting -4- Display Message Display message Situation Product specification Project Allow the thermometer remain in room temperature (10-40OC) for 30 minutes. Sensor error Please contact with the customer service. Memory error Please contact with the customer service. Temperature measured is higher than normal human temperature range (Body above 42.2OC; Surface above 60OC) Check the measured object and take a new measure. Temperature measured is lower than normal human temperature range (Body below 32OC; Body below 20OC) Check the measured object and take a new measure. Low battery Replace batteries. Content Infrared measuring Measuring mode Surface/body temperature Measuring distance 5~10cm Measuring Surrounding Accuracy Accuracy 32~42.2OC 16~35OC ±0.3OC 10~40OC ±0.4OC 20~32OC Solution Ambient temperature is out of operating range (10-40OC) - 7- This appliance conforms to the following standards: Measuring type 42.2~60OC Indicator Functions LCD display Low voltage tip <2.2V±0.3 Display resolution 0.1OC Unit Work surrounding 10OC~40OC Storage temperature -20OC~+50 OC EN60601-1: Medical electrical equipment Part 1: General requirements for safety EN12470-5: Clinical thermometers Part 5: Performance of infrared ear thermometers (with maximum device) 93/42/EEC : Medical Device Directive ASTM E 1965-98: Standard Specification for Infrared Thermometers for Intermittent Determination of Patient Temperature Manufacturer Rerfer to the instructions Equipment of BF Recycling and Processing C , OF Automatic shutdown 1 minute after not being used Memory 50 Group memory Battery 2 x AA Size 159×87.5×45.5 mm Weight About 98g (Not including batteries) 1. Use a soft, dry cloth to clean the exterior of the thermometer. - 6- 1. Pressing "Power" and display. 2. Press "MODE" key to select temperature measurement mode (body or surface) : (1) Thermometer is straight to the forehead, and distance is 5~10cm. 5~10cm Cleaning and Care - 5- F=1.8xOC+32 - 3- Memory Function Products use battery by 2, when a battery symbol appears and flash in the screen, and replace the battery as soon as possible. • Note: 1. Open the battery cover to replace batteries, and place the battery is the Pull and open the battery cover from location of the negative then on electrode correctly. 2. If not use, please take out the battery so as to protect instrument. Cranium Memory Mode - 2- 2. Keep the thermometer away from direct sunlight, dust and contamination environment. 3. Store the thermometer in normal room temperature, or within 10-40oC. 4. Don't touch with the finger. 5. Can use less than 75% of the rubbing alcohol to clean the lens. Replacing the Batteries Set Surface Measuring the temperature of the body and the surface on forehead with infrared. Products the same built-in infrared sensor and related hardware, software, can sense the analyte, analysis and records 3. Press the “Enter” button. 4. Press the “Thermometer” button. 5. When the measurement is complete, the temperature will display on Thermometer monitor & save on iOS application screen. 6. This thermometer stores the last temperature readings. 1. Pressing "Power" and display and showen the last records. 2. Pressing the "MEM" key to switch record shows upper * LCD display test records and record number. 3. Switch mode * Pressing the "MODE" key to switch MODE. LCD Body 4. Save setting value. Pressing the "SET" key for 3 seconds to save the value and exit setting mode. If F-04 value is "YES", The thermometer will be delete all records. (2) Pressing and holding the "Measure" key and move thermometer scaning forehead. (3) Release the "Measure" key to finish measurement and display the result on LCD. (4) Turn off: The thermometer will trun off automatically without use for 1 minute. - 1- • Note: The correct method of use is the key to test the accuracy. Please follow these instructions, so as to avoid the infrared measurement on the surrounding. 1. Testing temperature, as the showing in the figure, instrument and the distance from the forehead suggested in 5cm to 10cm. 2. Keep the body's temperature as the same as the surrounding. 3. It should be avoided cold and any disease of cool down the temperature. 4. Keep the Instrument's temperature as the same as the surrounding. 5. Forbidden to use this instrument in the strong sunshine place. 6. Measure suggestion: 3 times or so, every time when to display up to a set of data shall prevail. The component of product 1. Pressing the “SET” Key for 3 seconds, The thermometer will be turn on and enter the setting mode, the LCD display F-00 and alarm temperature value. 2. Modify the setting value Pressing the "MODE" or "MEM" key to change the value. 3. Switch to other setting item: Press the "SET" key to switch to other item. F-01: Offset value for body mode(-2.0~+2.0). Measurement Principle Rev.00 20131023 Product scope For measurement of body and surface temperature. Special Features 1. Measurement range: Body: 32~42.2OC / 90~108OF Surface: 20~60OC / 68~140OF 2. Free to set alarm temperature. 3. Non-contact measurement, avoid cross infection. 4. Memory for 50 readings. 5. Auto power off without use it. 6. Unit of Measure: OC/OF. 7. Backlight. F-02: Offset value for surface mode(-2.0~+2.0). F-03: Temperature Unit (OC/OF). F-04: Delete records(Yes,No) and environmental temperature, and once the user has to pass the instrument near certain parts of the body (forehead), and press the measure button can immediately active infrared radiation sensor. - 8- The european Union flag IP is short for Ingress Protection which means that Protection’s level. FCC Caution. § 15.19 Labelling requirements. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. If the labelling area is considered too small and therefore it is impractical (smaller than the palm of the hand) to display the compliance statement, then the statement may be placed in the user manual or product packaging. § 15.21 Information to user. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. § 15.105 Information to the user. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2014:06:27 11:43:35+08:00 Creator : Adobe Illustrator CS2 Modify Date : 2014:08:08 16:04:59+08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Format : application/pdf Title : TET-381英文说明书 蓝牙 Creator Tool : Adobe Illustrator CS2 Metadata Date : 2014:08:08 16:04:59+08:00 Thumbnail Width : 256 Thumbnail Height : 180 Thumbnail Format : JPEG Thumbnail Image : (Binary data 22621 bytes, use -b option to extract) Document ID : uuid:930B53B2ACFDE3118D349AD792B93430 Instance ID : uuid:c40598e3-b998-4fd4-9b3d-630884cabf3a Derived From Instance ID : uuid:080d1ae5-68a8-46ef-b17a-c5a1b134d009 Derived From Document ID : uuid:9AB1EF13A8FDE3118D349AD792B93430 Producer : Adobe PDF library 7.77 Page Count : 2 For : User, - Bounding Box : -1 -2 1135 793 Container Version : 9 Creator Version : 12EXIF Metadata provided by EXIF.tools