Truma Geraetetechnik and KG INETBOXA Interface box with Bluetooth User Manual 50050 152 G iNet 011214 GB indb
Truma Geraetetechnik GmbH & Co. KG Interface box with Bluetooth 50050 152 G iNet 011214 GB indb
User Manual
iNet Box Operating Instructions To be kept in the vehicle! 11:05, 12.03.2015 ENTWURF DRAFT Page 2 iNet Box Table of Contents Symbols used Symbols used ......................................................................... 2 Intended use ........................................................................ 2 Intended use Operating Instructions Safety instructions .............................................................. Display and control panels / connections ....................... Preparing start-up ............................................................... Install the Truma app on mobile terminal device ................... Device identification ............................................................... Bluetooth communication ................................................. Bluetooth connection set-up .................................................. Bluetooth bonding .................................................................. GSM communication .......................................................... Preparing iNet Box ................................................................. Setting up the GSM connection ............................................. Operation ............................................................................. Technical data ...................................................................... Troubleshooting guide ....................................................... Factory setting ..................................................................... Cleaning ................................................................................ Maintenance ....................................................................... Disposal ................................................................................ Accessories .......................................................................... Declaration of conformity .................................................. Warranty declaration .......................................................... Note containing information and tips. The iNet Box was developed for controlling TIN-bus-capable Truma devices via mobile terminal devices (e.g. smartphones, tablet PCs). Communication is via Bluetooth or GSM. Display panels BLUETOOTH –– iNet Box must not be operated unless it is in technically perfect condition. –– Repairs must be carried out immediately. Only carry out repairs yourself if the solution is described in the troubleshooting guide of this manual. GSM –– A defective iNet Box may only be repaired by the manufacturer or the manufacturer’s service department. Description Bluetooth – flashes for Bluetooth pairing with 1 Hz Power – lights up when ready for operation GMS – lights up when GSM operation is not possible –– This device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Control panels / connections –– Le présent appareil est conforme aux CNR d‘Industrie Canada applicables aux appareils radio exempts de licence. L‘exploitation est autorisée aux deux conditions suivantes : (1) l‘appareil ne doit pas produire de brouillage, et (2) l‘utilisateur de l‘appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d‘en compromettre le fonctionnement. Figure 2 – Rear view Item INT LED Blue Green Red EXT –– Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Figure 1 – Top view GSM –– Do not perform any modifications to the iNet Box as this can be dangerous. iNet Box SIM Safety instructions Display and control panels / connections POWER Operating Instructions Description Bluetooth / factory setting button Insert, Mini-SIM card (25 x 15 mm) External antenna connection GSM (SMA) Changeover switch, internal / external antenna Preparing start-up Install the Truma app on mobile terminal device 1. Load the Truma app (at www.truma.com) onto the mobile terminal device. 2. Install the Truma app on the mobile terminal device. If necessary, an installed Truma app must be updated. 3. Repeat steps 1 and 2 for additional mobile terminal devices. 4. To continue installation, start the “Set-up assistant” of the Truma app or follow the instructions below. 5. Switch on all devices connected to the iNet Box (see “Bluetooth connection set-up” on Page 4). Bluetooth communication Bluetooth connection set-up To connect the mobile terminal device to the iNet Box, the mobile terminal device must be switched on and Bluetooth must be activated (see the operating instructions of the mobile terminal device). –– Press the button (Figure 2 – 1) for approximately 1 second. Device identification If the Bluetooth pairing is active, the iNet Box becomes visible for 3 minutes and the blue LED (Figure 1) flashes at the same time at a frequency of 1 Hz. The name “iNet Box” appears on the mobile terminal device. The TIN-bus-capable Truma devices connected to the iNet Box and CP plus must be known to the CP plus. The Bluetooth connection to the mobile terminal device can be made. 1. Connect all TIN-bus-capable Truma devices to the CP plus and the iNet Box. 2. Switch on the power supply for the devices connected to the CP plus and iNet Box (including iNet Box). 3. Perform the device search on the CP plus (see CP plus operating instructions, “Initial start-up”). After a repair / retrofitting, the device search with CP plus must be repeated. 4. At least the Bluetooth communication must be set up for each mobile terminal device. Up to 20 mobile terminal devices can be logged on / saved on the Bluetooth connection. Four mobile terminal devices can control the iNet Box at the same time. The first mobile terminal device set up (administrator) remains permanently in the iNet Box memory. The 21st mobile terminal device overwrites the second one in the memory. This means that each new mobile terminal device logged on overwrites the oldest one in the memory. The first mobile terminal device set up (administrator) can only be deleted by restoring to the factory setting (see “Factory setting” on page 6on Page 6) in the iNet Box. Bluetooth bonding If there is a saved mobile terminal device within range of the iNet Box, a Bluetooth bonding to the iNet Box is automatically performed. Removing the Mini-SIM card Pressing the Mini-SIM card again enables it to be removed. Setting up the GSM connection GSM communication An active Bluetooth connection is required for the continued installation and the Truma app on the mobile terminal device must be started. Preparing iNet Box 1. Select the “set-up assistant” of the Truma app A Bluetooth connection must first be established before the GSM communication can be set up and operated. 2. Via the “set-up assistant”, enter the PIN and the call number of the Mini-SIM (iNet Box), and also a freely selectable name (maximum 11 characters). A Mini-SIM card with its own call number and sufficient credit is required for GSM communication. The Mini-SIM card is not included in the scope of delivery. Insert the Mini-SIM card Position the Mini-SIM card (25 x 15 mm) so that the missing corner faces the slot and the contact surface faces the bottom of the iNet Box. –– If the Mini-SIM card is replaced, the GSM connection must be set up again before using the GSM communication. INT EXT GSM SIM Mini-SIM Push the Mini-SIM card into the “SIM” slot until it engages. Notes: –– The Mini-SIM card is blocked after 3 incorrect PIN entries. To unblock, the Mini-SIM card must be removed from the iNet Box and unblocked in the mobile terminal device with the PUK. Figure 3 Operation Troubleshooting guide To operate the devices connected via the iNet Box, follow the steps in the Truma app. –– The last incoming command is executed. –– Bluetooth communication has priority over GSM communication. –– The iNet Box automatically switches from GSM to Bluetooth communication as soon as a saved mobile terminal device comes into reception range. –– It automatically switches back to GSM communication when the device goes out of reception range. 147 x 96 x 40 mm -30 °C to +60 °C 10%rH to 99%rH 942 hPa to 1061 hPa -30 °C to +70 °C TIN bus 9 V – 29 V xxx mA xxx mA approx. 500 g External GSM antenna Anntenna gain max. 5.5 dBi at 850 MHz and max. 2 dBi at 1900 MHz Subject to technical changes. Check the operating voltage. LED red – GSM error –– No GSM reception –– No Mini-SIM card –– Mini-SIM card blocked –– Modem error Progress bar stops during firmware update / Bluetooth connection interrupted for an extended time / previous firmware status remains. Factory setting Technical data Dimensions (L x W x H) Operating conditions Temperature Humidity Air pressure Storage temperature range Interface Power supply Power consumption Standby current Weight The green “Power” LED (ready for operation) does not light up. Reset all settings to the factory setting and delete all individual data. –– Press the button (Figure 2 – 1) for at least 20 seconds. The blue LED flashes briefly to indicate that resetting has been done. Cleaning Clean only with a moist, lint-free cloth. Make sure that no liquid gets inside the iNet Box. This can cause a short circuit and destruction of the iNet Box. Maintenance Declaration of conformity There are no components inside the iNet Box that require servicing by the customer. 1. Information about the manufacturer If it is faulty, replace the complete iNet Box. Firmware update An iNet Box firmware update is indicated in the Truma app on the mobile terminal device. Transmission is via Bluetooth (follow the instructions in the Truma app). Disposal The device must be disposed of in accordance with the administrative regulations of the respective country in which it is used. National regulations and laws (in Germany, for example, the End-of-life Vehicle Regulation) must be observed. Accessories External GSM antenna TIN-bus cable, 3 different lengths Name: Truma Gerätetechnik GmbH & Co. KG Address: Wernher-von-Braun-Str. 12, D-85640 Putzbrunn 2. Device identification Type / model: GSM control unit / iNet Box 3. C omplies with the requirements of the following EC directives 3.1 3.2 3.3 3.4 Electromagnetic compatibility 2004/108/EC Radio interference suppression of motor vehicles UN ECE R10 End-of-life vehicle directive 2000/53/EC Low Voltage Directive 2006/95/EC and bears the CE mark and the type approval number E1 xxxxxxxxxxxxx 4. Basis of the proof of conformity 6. Signatory details Signature: xxxxx xxxxxxxx Putzbrunn, 17.11.2014 Warranty declaration 9 Las instrucciones de uso y de montaje en su idioma pueden solicitarse al fabricante Truma o al Servicio postventa Truma en su país. Saat käyttö- ja asennusohjeen pyynnöstä omalla kielelläsi valmistajalta (Truma) tai maasi Truma-huoltoon. Spør om bruks- og monteringsanvisning på norsk hos produsenten Truma eller Trumas serviceavdeling i landet ditt. Μπορείτε να ζητήσετε τις οδηγίες χρήσης και τοποθέτησης στη γλώσσα της χώρας σας από τον κατασκευαστή Truma ή από το σέρβις της Truma στη χώρα σας. Návod k použití a montážní návod si lze v řeči Vaší země vyžádat u výrobce Truma nebo servisu Truma ve Vaší zemi. Návod na použitie a montáž vo Vašom štátnom jazyku si môžete vyžiadať u výrobcu Truma alebo v servise Truma vo Vašej krajine. As instruções de utilização e montagem podem ser solicitadas junto do fabricante Truma ou do serviço de assistência da Truma no seu país. Az Ön nyelvén a használati és beszerelési utasítás a Truma gyártójától vagy az adott ország Truma szerviztől szerezhető be. Instrukcję obsługi i instrukcję montażu w Państwa wersji językowej można otrzymać w firmie Truma lub serwisie firmy Truma znajdującym się w Państwa kraju. TR Dilinizdeki kullanma ve montaj talimatı, üretici Truma'dan veya ülkenizdeki Truma servisinden talep edilebilir. Руководство по эксплуатации и монтажу на Вашем национальном языке можно запросить у изготовителя Truma или в сервисной службе фирмы Truma в Вашей стране. iNet Box Installation Instructions 11:16, 12.03.2015 ENTWURF DRAFT Page iNet Box Table of Contents Symbols used ......................................................................... 2 Symbols used Installation Instructions Safety instructions .............................................................. Intended use ........................................................................... Scope of delivery .................................................................... Accessories ............................................................................ Dimensions ............................................................................. Connections ........................................................................... Displays .................................................................................. Selecting a location ................................................................ Connection examples ............................................................. Assembly ................................................................................ The unit must only be installed and repaired by an expert. Note containing information and tips. Installation Instructions Dimensions Safety instructions In-vehicle installations must comply with the technical and administrative regulations of the respective country of use (e.g. EN 1648, VDE 0100-721). National regulations and rules must be followed. In other countries, the relevant regulations must be observed. Intended use The iNet Box was developed for controlling TIN-bus-capable Truma devices via mobile terminal devices (e.g. smartphones, tablet PCs). Communication is via Bluetooth or GSM. L x W x H 147 x 96 x 40 The dimensions are in mm Scope of delivery Connections 1 iNet Box 1 Fastening bracket 1 Set of operating instructions 1 Set of installation instructions 1 12 V connector cable 30 cm (+ = red , - = blue) 1 Connector cable (TIN-bus) Front view Accessories External GSM antenna TIN-bus cable, 3 different lengths POWER (9 V – 29 V operating voltage) TIN 1 TIN 2 Rear view Selecting a location Install the iNet Box in a location that is protected from moisture and humidity. For optimum transmission and reception, secure the iNet Box as high up as possible, e.g. above a window and in the middle of the vehicle. At the same time, due to the position of the installed antennae, the connections should go upwards or downwards (secure the box perpendicular on the wall). BLUETOOTH / factory settings button Mini-SIM (25 x 15 mm) External antenna connection GSM (SMA) Changeover switch, internal / external antenna GSM The slot for the Mini-SIM and the external GSM antenna connection, the internal / external antenna changeover switch and the button for the BLUETOOTH pairing must remain accessible. Displays Connect the external GSM antenna Top view People must maintain a distance of at least 20 cm from the antenna. Blue LED (BLUETOOTH pairing status) Green LED (POWER lights up during operation) Red LED (GSM) lights up when GSM operation is not possible. Connection examples –– Plug the cable (TIN-bus) into the iNet Box TIN 1/2 and connect it to a TIN-capable heater and/or air conditioning system (from 01.04.2015 onwards, the heater can only be operated in conjunction with a CP plus control panel). –– Plug in the 12 V connector cable and attach to unswitched 12 V operating voltage (permanent positive). Protect the positive cable with a 1 A fuse (near to the positive terminal of the power source). When the CP plus control panel is used, the same circuit as that of the iNet Box must be used. Figure 2 Figure 1 Figure 3 Figure 4 Figure 6 Figure 5 Figure 7 Assembly Initial start-up should be carried out before starting assembly –– Download the app to the mobile phone Establish the Bluetooth connection to the iNet Box Search for the location with the best Bluetooth reception –– Establish the position of the iNet Box (safety clearance >20cm from people). –– Fix the iNet Box to the wall at the established position using the two adhesive strips (the surface must be clean and smooth). –– Lay the iNet Box cables clear of the 230 V cables (approx. 20 cm) . –– The cables must have strain relief. Subject to technical changes. Bei Störungen wenden Sie sich bitte an das Truma Servicezentrum oder an einen unserer autorisierten Servicepartner (siehe www.truma.com). Für eine rasche Bearbeitung halten Sie bitte Gerätetyp und Seriennummer (siehe Typenschild) bereit. Should problems occur, please contact the Truma Service Centre or one of our authorised service partners (see www.truma.com). 50000-15100 · 01 · 12/2014 · © In order to avoid delays, please have the unit model and serial number ready (see type plate). Veuillez vous adresser au centre de SAV Truma ou à un de nos partenaires de SAV agréés en cas de dysfonctionnements (voir www.truma.com). Pour un traitement rapide de votre demande, veuillez tenir prêts le type d’appareil et le numéro de série (voir plaque signalétique). In caso di guasti rivolgersi al centro di assistenza Truma o a un nostro partner di assistenza autorizzato (consultare il sito www.truma.com). Affinché la richiesta possa essere elaborata rapidamente, tenere a portata di mano il modello dell’apparecchio e il numero di matricola (vedere targa dati). Truma Gerätetechnik GmbH & Co. KG Wernher-von-Braun-Straße 12 85640 Putzbrunn Deutschland Service Telefon Telefax +49 (0)89-4617-2020 +49 (0)89 4617-2159 service@truma.com www.truma.com Bei Störungen wenden Sie sich bitte an das Truma Servicezentrum oder an einen unserer autorisierten Servicepartner (siehe www.truma.com). Für eine rasche Bearbeitung halten Sie bitte Gerätetyp und Seriennummer (siehe Typenschild) bereit. Should problems occur, please contact the Truma Service Centre or one of our authorised service partners (see www.truma.com). 50050-15200 · 01 · 12/2014 · © In order to avoid delays, please have the unit model and serial number ready (see type plate). Veuillez vous adresser au centre de SAV Truma ou à un de nos partenaires de SAV agréés en cas de dysfonctionnements (voir www.truma.com). Pour un traitement rapide de votre demande, veuillez tenir prêts le type d’appareil et le numéro de série (voir plaque signalétique). In caso di guasti rivolgersi al centro di assistenza Truma o a un nostro partner di assistenza autorizzato (consultare il sito www.truma.com). Affinché la richiesta possa essere elaborata rapidamente, tenere a portata di mano il modello dell’apparecchio e il numero di matricola (vedere targa dati). Truma Gerätetechnik GmbH & Co. KG Wernher-von-Braun-Straße 12 85640 Putzbrunn Deutschland Service Telefon Telefax +49 (0)89-4617-2020 +49 (0)89 4617-2159 service@truma.com www.truma.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Create Date : 2015:03:12 11:04:30+01:00 Metadata Date : 2015:03:18 10:28:31+01:00 Modify Date : 2015:03:18 10:28:31+01:00 Creator Tool : Adobe InDesign CS6 (Windows) Instance ID : uuid:753e520e-8d6b-4fa7-9278-7205f380dc51 Original Document ID : adobe:docid:indd:79a7855c-c630-11df-981e-cc5ffdf2ba61 Document ID : xmp.id:A961C4009FC8E41187E3E94B6F92EC18 Rendition Class : proof:pdf Version ID : 1 Derived From Instance ID : xmp.iid:A861C4009FC8E41187E3E94B6F92EC18 Derived From Document ID : xmp.did:B4461F6DECC7E411877D89762780780A Derived From Original Document ID: adobe:docid:indd:79a7855c-c630-11df-981e-cc5ffdf2ba61 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2015:03:12 11:04:30+01:00 Format : application/pdf Title : 50050_152_G_iNet_011214_GB.indb Producer : Adobe PDF Library 10.0.1 Trapped : False GTS PDFX Version : PDF/X-3:2002 GTS PDFX Conformance : PDF/X-3:2002 Page Count : 19 Creator : Adobe InDesign CS6 (Windows)EXIF Metadata provided by EXIF.tools