Tyco Safety Canada 06F23X Field Disturbance Sensor User Manual
Digital Security Controls Ltd. Field Disturbance Sensor istisd23f2 300 0 0
a href="https://usermanual.wiki/Tyco-Safety-Canada" itemprop="url">
Tyco Safety Canada >
User Manual

!["AND" OPERATING MODE The de tec tor will go into alarmwhen both sen sors gen er ate the pro grammed num ber of pulses(see AND col umn – Ta ble 2) within 20 sec onds. This op er at ingmode ap plies to mod els F2-303, F2-304, F2-305, F2-306 andmod els F2-301 and F2-302 if DIP-switch no. 5 is ON (see theDIP-switch strip 20).+One long pul se (of 1 se cond) will also ge ne ra te Alarm sta tus."AND/OR" OPERATING MODE (F2-301 / F2-302) This modeis achieved by turn ing DIP-switch no. 5 OFF (see the DIP-switchstrip 20). The de tec tor will op er ate as per AND mode, and will alsowork when one of the sen sors is blinded or out-of-or der (OR). Inthis case, the de tec tor will go into alarm when the work ing sen sorgen er ates the pro grammed num ber of pulses (see OR col umn –Ta ble 2) within 20 sec onds.DISABLING THE LEDs The LEDs can be dis abled by re mov ingthe jumper 15 WT (for mod els: F2-303, F2-304, F2-305, F2-306) orby turn ing DIP-switch no. 4 OFF (see the DIP-switch strip 20 – formod els: F2-301 and F2-302).ENABLING THE MEMORY (F2-301 / F2-302 / F2-303 / F2-304)This fea ture is use ful in ap pli ca tions where sev eral de tec tors arecon nected to the same con trol panel zone. If the De tec tor sig nals analarm to the Con trol panel, the red LED will glow when the sys tem dis -arms thus in di cat ing the ex act place of vi o la tion. The mem ory willclear and the red LED will go OFF when the con trol panel re arms. To en able the mem ory:> con nect ter mi nal [M] to a con trol panel out put which closes toneg a tive when the con trol panel dis arms (for mod els F2-303 andF2-304 and mod els F2-301 and F2-302 if DIP-switch no. 3 is ON— see the DIP-switch strip 20) or,> con nect ter mi nal [M] to a con trol panel out put which opens whenthe con trol panel dis arms (for mod els F2-301 and F2-302 ifDIP-switch no. 3 is OFF — see the DIP-switch strip 20).+If the Mem ory func tion is not re quired, DO NOT con nect ter mi nal [M] and turn DIP-switch no. 3 ON (see the DIP-switch strip 20).DISABLING THE MICROWAVE (F2-301 / F2-302 / F2-303 / F2-304)To dis able the Mi cro wave, con nect ter mi nal [MW] to a con trolpanel out put which closes to neg a tive when con trol panel dis arms.WALK TEST Cre ate mo tion in the pro tected area, grad u ally in -crease the sen si tiv ity level (use trim mers 13 and 14) un til thegreen and yel low LEDs sig nal mo tion de tec tion.COMPONENT IDENTIFICATIONTECHINCAL FEATURESMi cro wave fre quency:F2-302 / F2-304 / F2-306F2-301 / F2-303 / F3-30510.515 GHz10.525 GHzRange 12 mPower sup ply 12 Vdc ± 3 VCur rent draw: F2-301 / F2-302F2-303 / F2-304F2-305 / F2-30610 mA (20 mA max.)10 mA (30 mA max.)12 mA (30 mA max.)Alarm con tact N. C. (form A)Alarm pulse 0.5 sTam per switch N. C.Mi cro phone sen si tiv ity (F2-305 / F2-306) -24 dB (300 to 4000 Hz)Tem per a ture range -10 to +40 °CPro tec tion clas si fi ca tion IP 40Di men sions (W*H*D) 60*105*44 mmWeight 200 gNCGND++uWPIRPWT+ASMICMIC1 2 3 4 5ONMWNCAS M++B032 uWPIRPWT91011121314199101511161211121314910151614201913191817a)b)c)Fig. 4Elec tronic board components: a) F2-301 / F2-302;b) F2-303 / F2-304; c) F2-305 / F2-306.Com po nen tes de la tar je ta elec tró ni ca: a) F2-301 /F2-302; b) F2-303 / F2-304; c) F2-305 / F2-306.Com po sants de la carte élec tro nique : a) F2-301 / F2-302; b) F2-303 / F2-304; c) F2-305 / F2-306.Par ti del le sche de: a) F2-301 / F2-302; b) F2-303 /F2-304; c) F2-305 / F2-306.Czê œci sk³ad owe elekt roni cznej p³ytki dru kow anej:a) F2-301 / F2-302; b) F2-303 / F2-304; c) F2-305 / F2-306.FUN ZIO NA MEN TO AND Il Ri le va to re va in al lar me quan do i suoisen so ri ge ne ra no, con tem po ra ne a men te, il nu me ro di im pul si pro -gram ma to, in un tem po mas si mo di 20 s (co lon na AND del laTab. 2). Qu e sto è l'u ni co modo di fun zio na men to dei ri le va to riF2-303, F2-304, F2-305 ed F2-306, men tre per i ri le va to ri F2-301 ed F2-302, si im po sta por tan do su ON il dip-switch n. 5 del ban co 20.+Il Ri le va to re va in al lar me an che con un im pul so con tem po ra -neo di 1 s.FUNZIONAMENTO AND/OR (F2-301 ed F2-302) Oltre a fun zio -na re come nel modo pre ce den te (AND), se uno dei due sen so ri vie ne ac ce ca to, il Ri le va to re va in al lar me quan do il sen so re fun zio nan tege ne ra il nu me ro di im pul si pro gram ma to, in un tem po mas si mo di 20s (co lon na OR del la Tab. 2). Qu e sto modo di fun zio na men to si im po -sta por tan do su OFF il dip-switch n. 5 del ban co 20.ESCLUSIONE LED I LED di se gna zio ne del Ri le va to re pos so no es -se re esclu si per non re ca re di stur bo o per na scon de re la pre sen za delRi le va to re. Per esclu de re i LED dei ri le va to ri F2-303, F2-304, F2-305ed F2-306, ri mu o ve re il pon ti cel lo 15 (WT). Per esclu de re i LED dei ri le -va to ri F2-301 ed F2-302, por ta re in OFF il dip-switch n. 4 del ban co 20.ABILITAZIONE MEMORIA (F2-301 / F2-302 / F2-303 / F2-304)Qu e sta fun zio ne è uti le quan do si de vo no col le ga re più ri le va to ri allastes sa li nea di una cen tra le, per sa pe re in qua le pun to pre ci so è av ve -nu ta l’in tru sio ne: se a cen tra le di sin se ri ta il LED ros so di un Ri le va to reri ma ne ac ce so, vuol dire che quel Ri le va to re è an da to in al lar me. Lame mo ria vie ne can cel la ta e il LED ros so si spe gne quan do la cen tra levie ne in se ri ta. Per abi li ta re la me mo ria, col le ga re il mor set to [M] ad unausci ta del la cen tra le che va a mas sa quan do la cen tra le è in se ri ta (ri le -va to ri F2-303 ed F2-304, ed F2-301 ed F2-302 con il dip-switch n. 3, del ban co 20, in ON) op pu re, che re sta ap pe sa quan do la cen tra le è in se ri -ta (F2-301 ed F2-302 con il dip-switch n. 3, del ban co 20, in OFF).+Se NON si vu o le uti liz za re la me mo ria, NON col le ga re il mor -set to [M] e la scia re il dip-switch n. 3, del ban co 20, in ON.ESCLUSIONE MICROONDA (F2-301 / F2-302 / F2-303 / F2-304)La mi cro on da può es se re esclu sa per ri dur re l'in qui na men toelet tro ma gne ti co, col le gan do il mor set to [MW] ad un open-col lec -tor del la cen tra le che va a mas sa a cen tra le di sin se ri ta.PROVA DI COPERTURA Ese gui re nel l’am bien te in cui è in stal la -to il Ri le va to re, una pro va di cam mi no ed au men ta re gra dual men tela sen si bi li tà (trim mer 13 e 14) af fin chè i LED ver de e gial lo se gna li -no che i vo stri mo vi men ti sono sta ti ri le va ti da en tram bi i sen so ri.IDENTIFICAZIONE DELLE PARTICARATTERISTICHE TECNICHEFre quen za mi cro on de:F2-302 / F2-304 / F2-306F2-301 / F2-303 / F3-30510,515 GHz10,525 GHzPor ta ta 12 mAli men ta zio ne 12 Vdc ± 3 VAssor bi men to:F2-301 / F2-302F2-303 / F2-304F2-305 / F2-30610 mA (20 mA max.)10 mA (30 mA max.)12 mA (30 mA max.)Usci ta al lar me N. C.Impul so di al lar me 0,5 sUsci ta sa bo tag gio N. C.Sen si bi li tà mi cro fo no (F2-305 / F2-306) -24 dB (300 ÷ 4000 Hz)Tem pe ra tu ra di fun zio na men to -10 ÷ +40 °CGra do di pro te zio ne IP 40Di men sio ni (L*H*P) 60*105*44 mmPeso 200 g1Co pri vi te2Vite di chiu su ra3Co per chio4Aper tu re per i fili5Fon do6Fori per i cavi ca na liz za tiester na men te7Staf fa per il fis sag gio inpia no8Staf fa per il fis sag gio adan go lo9Mor set tie ra10 LED di al lar me in fra ros so (ver de)11 LED di al lar me mi cro on -da (gial lo)12 LED di al lar me (ros so)13 Sen si bi li tà in fra ros so: ru -o tan do in sen so ora rioaumenta14 Sen si bi li tà mi cro on da:ru o tan do in sen so ora rioaumenta15 Esclu sio ne LED16 Pro gram ma zio ne con ta -im pul si17 Mi cro fo no18 Sen si bi li tà mi cro fo no: ru -o tan do in sen so ora rioau men ta19 De via to re an ti sa bo tag gio20 Dip-switch1Screw cap2Screw3Co ver4Wire en tries5Back pla te6Exter nally rou ted ca bleentry7Back pla te-mount brac ket8Cor ner/Side-mount brac -ket9Ter mi nal board10 Infra red alarm LED(green)11 Mi cro wa ve alarm LED(ye llow)12 Me mory and ge ne ralalarm LED (red)13 Infra red sen si ti vity trim -mer: turn clock wi se to in -crea se14 Mi cro wa ve sen si ti vity trim -mer: turn clock wi se to in -crea se15 Di sa ble LED jum per16 Pul se Coun ter jum per17 Mi crop ho ne18 Mi crop ho ne sen si ti vity trim -mer: turn clock wi se to in -crea se19 Tam per switch20 DIP-switchMODO DE OPERACIÓN "Y" El de tec tor dis pa ra rá la alar macuan do am bos sen so res ge ne ren el nú me ro pro gra ma do de im -pul sos (co lum na Y - Ta bla 2) a lo lar go de 20 s. Este modo de ope -ra ción apli ca a los mo de los F2-303, F2-304, F2-305, F2-306 y alos mo de los F2-301 y F2-302 si el mi croin te rrup tor n.º 5 está en -cen di do (ON) (véa se el mi croin te rrup tor DIP 20).+Un im pul so lar go (de 1 s) tam bién ge ne ra rá el es ta do de Alar ma.MODO DE OPERACIÓN "Y/O" (F2-301 / F2-302) Este modose con si gue apa gan do (OFF) el mi croin te rrup tor n.º 5 (véa se elmi croin te rrup tor DIP 20). El de tec tor fun cio na rá como en el modoY, pero tam bién fun cio na rá cuan do uno de los sen so res es ce ga -do o se en cuen tra ave ria do (O). En este caso, el de tec tor dis pa ra -rá la alar ma cuan do el sen sor ope ra ti vo ge ne re el nú me ropro gra ma do de im pul sos (co lum na O - Ta bla 2) a lo lar go de 20 s.DESHABILITAR LOS LED Los LED pue den ser des ha bi li ta dosre ti ran do el puen te 15 WT (para los mo de los: F2-303, F2-304,F2-305, F2-306) o apa gan do (OFF) el mi croin te rrup tor n.º 4 (mi -croin te rrup tor DIP 20 – para los mo de los: F2-301 y F2-302).HABILITAR LA MEMORIA (F2-301 / F2-302 / F2-303 / F2-304)Esta fun ción re sul ta útil en apli ca cio nes en las que hay va rios de tec -to res co nec ta dos a la mis ma zona del pa nel de con trol. Si el de tec toren vía una alar ma al pa nel del con trol, el LED rojo se en cen de rá cuan do el sis te ma se de sac ti ve, in di can do de este modo el lu gar exac to de lain tru sión. La me mo ria se bo rra rá y el LED rojo se apa ga rá (OFF) cuan -do el pa nel de con trol vuel va a ac ti var se. Para ha bi li tar la me mo ria:> co nec te el ter mi nal [M] a una sa li da del pa nel de con trol que se cie rrapa san do al es ta do ne ga ti vo cuan do el pa nel de con trol se de sac ti va(para los mo de los F2-303 y F2-304 y los mo de los F2-301 y F2-302, siel mi croin te rrup tor n.º 3 está ON - véa se el mi croin te rrup tor DIP 20) o,> co nec te el ter mi nal [M] a una sa li da del pa nel de con trol que se abre cuan do el pa nel se de sac ti va (para los mo de los F2-301 y F2-302, siel mi croin te rrup tor n.º 3 está OFF - véa se el mi croin te rrup tor DIP 20).+Si la fun ción Me mo ria no es un re qui si to, NO co nec te el ter mi nal [M] y en cien da (ON) el mi croint. n.º 3 (véa se el mi croin te rrup tor DIP 20).BLOQUEAR LAS MICROONDAS (F2-301 / F2-302 / F2-303 / F2-304)Para des ha bi li tar las mi croon das, co nec te el ter mi nal [MW] auna sa li da del pa nel de con trol que se cie rra pa san do al es ta done ga ti vo cuan do el pa nel de con trol se de sac ti va.PRUEBA DE DESPLAZAMIENTO Cree un mo vi mien to en lazona pro te gi da, in cre men te gra dual men te el ni vel de sen si bi li dad (uti -li ce los con tem po ri za do res 13 y 14) has ta que los LED ver de y ama ri -llo in di quen la de tec ción del mo vi mien to.IDENTIFICACIÓN DE COMPONENTESFICHA TÉCNICAFre cue cia de mi croon das:F2-302 / F2-304 / F2-306F2-301 / F2-303 / F3-30510,515 GHz10,525 GHzAlcan ce 12 mAli men ta ción 12 Vdc ± 3 VCon su mo: F2-301 / F2-302F2-303 / F2-304F2-305 / F2-30610 mA (20 mA max.)10 mA (30 mA max.)12 mA (30 mA max.)Con tac to de alar ma N. C. (form A)Impul so de alar ma 0,5 sInte rrup tor sa bo ta je N. C.Sen si bi li dad del mi cró fo no (F2-305 / F2-306) -24 dB (300 a 4000 Hz)Inter va lo de tem pe ra tu ra -10 a +40 °CPro tec ción IP 40Di men sio nes (An*Al*Pr) 60*105*44 mmPeso 200 gF2-303 / F2-304 F2-301 / F2-302PULSES F2-305 / F2-306 DIP-SWITCH 20OR AND Jumper 16 (P) no. 1 no. 221Inserted ON ON42Removed OFF ON63/ON OFF63/OFF OFFTab. 2Pulse chart1Ta pón de ros ca2Tor ni llo3Tapa4Entra da de ca bles5Pla ca de apo yo6Ori fi cio de en tra da de ca -bles tra za dos por el ex te rior7Escua dra mon ta da conpla ca de apo yo8Escua dra mon ta da en es -qui na/la te ral9Pla ca de ter mi na les10 LED de alar ma in fra rro ja(ver de) 11 LED de alar ma por mi -croon das (ama ri llo)12 LED de me mo ria y alar mage ne ral (rojo)13 Re gu la dor de sen si bi li dadde in fra rro jos: gí re lo en sen -ti do ho ra rio para au men tar la14 Re gu la dor de sen si bi li dad de mi croon das: gí re lo en sen ti -do ho ra rio para au men tar la15 De sac ti va ción de LED16 Puen te del con ta dor de im -pul sos17 Mi cró fo no18 Re gu la dor de sen si bi li daddel mi cró fo no: gí re lo en sen -ti do ho ra rio para au men tar la19 Inte rrup tor de se gu ri dad20 Mi croin te rrup tor DIPF2-303 / F2-304 F2-301 / F2-302IMPULSOS F2-305 / F2-306 MICRO-INTERRUPTOR DIP 20OYPuente 16 (P) no. 1 no. 221Insertado ON ON42Retirado OFF ON63/ON OFF63/OFF OFFTab. 2Gráfico de impulsosMODE DE FONCTIONNEMENT "ET" Le dé tec teur dé clenchel'a larme lorsque les deux cap teurs gé nè rent le nombre pro gram méd'im pul sions (voir co lonne ET - Ta bleau 2) en 20 s. Ce mode defonc tion ne ment s'ap plique aux mo dè les F2-303, F2-304, F2-305,F2-306 et les mo dè les F2-301 si l'in ter rup teur no. 5 est sur la po si -tion ON (voir l'in ter rup teur DIP bande 20).+Une longue im pul sion (d'1 s) gé nè re ra éga le ment l'é tat d'a larme.MODE DE FONCTIONNEMENT "ET/OU" (F2-301 / F2-302)Ce mode est ob te nu en pla çant l'in ter rup teur DIP sur OFF (voir l'in ter -rup teur DIP bande 20). Le dé tec teur fonc tion ne ra de la même fa çonqu'en mode ET, et fonc tion ne ra éga le ment lorsque l'un des cap teursest obs trué ou hors ser vice (OU). Dans ce cas, le dé tec teur dé clen -che ra l'a larme lorsque le cap teur qui fonc tionne gé nère le nombrepro gram mé d'im pul sions (voir co lonne OU - Ta bleau 2) en 20 s.DESACTIVER LES LED Les LED peu vent être dé sac ti vés enre ti rant le ca va lier 15 WT (pour les mo dè les: F2-303, F2-304,F2-305, F2-306) ou en pla çant l'in ter rup teur no. 4 sur la po si tionOFF (voir l'in terr. DIP 20 – pour les mo dè les: F2-301 et F2-302).ACTIVER LA MEMOIRE (F2-301 / F2-302 / F2-303 / F2-304)Cette fonc tion est utile pour les ap pli ca tions où plu sieurs dé tec teurssont connec tés au même ta bleau de com mande. Si le dé tec teur si -gnale une alarme au ta bleau de com mande, le LED rouge s'al lumelorsque le sys tème est dé sar mé en in di quant l'em pla ce ment exactde la vio la tion. La mé moire s'ef face et le LED rouge s'é teint lorsquele ta bleau de com mande est réar mé. Pour ac ti ver la mé moire:> connec tez le ter mi nal [M] à une sortie qui se ferme sur le pôle né -ga tif lorsque le ta bleau de com mande est dé sar mé (pour les mo dè -les F2-303 et F2-304 et les mo dè les F2-301 et F2-302 sil'in ter rup teur no. 3 est sur ON - voir l'in ter rup teur DIP bande 20) ou,> connec tez le ter mi nal [M] à une sortie qui se ferme sur le pôle né ga tivelorsque le ta bleau de com mande est dé sar mé (pour les mo dè les F2-301et F2-302 si l'in terr. no. 3 est sur OFF - voir l'in terr. DIP bande 20).+Si la fonc tion mé moire n'est pas re quise, NE PAS connec ter le ter -mi nal [M] et pla cer l'in terr. no. 3 sur ON (voir l'in terr. DIP bande 20).DESACTIVER L'HYPERFREQUENCE (F2-301 / F2-302 / F2-303 / F2-304)Pour dé sac ti ver l'hy per fré quence, connec tez le ter mi nal [MW] àune sortie du ta bleau de com mande qui se ferme sur le pôle né ga -tif lorsque le ta bleau de com mande est dé sar mé.TEST DE FONCTIONNEMENT Créez du mou ve ment dans lazone pro tégée, aug men tez pro gres si ve ment le ni veau de sen si bi -li té (uti li sez les conden sa teurs 13 et 14) jus qu'à ce que les LEDvert et jaune si gna lent la dé tec tion du mou ve ment.IDENTIFICATION DES COMPOSANTSCARACTERISTIQUES TECHNIQUESFré quen ce hyper fré quen ce: F2-302 / F2-304 / F2-306F2-301 / F2-303 / F3-30510,515 GHz10,525 GHzGam me 12 mAli men ta tion élec tri que 12 Vdc ± 3 VAppel de cou rant: F2-301 / F2-302F2-303 / F2-304F2-305 / F2-30610 mA (20 mA max.)10 mA (30 mA max.)12 mA (30 mA max.)Con tact d'a lar me N. C. (form A)Impul sion d'a lar me 0,5 sInte rrup teur anti-sa bo ta ge N. C.Sen si bi li té du mi crop ho ne (F2-305 / F2-306) -24 dB (300 à 4000 Hz)Gam me de tem pé ra tu re -10 à +40 °CClas se de pro tec tion IP 40Di men sions (L*H*P) 60*105*44 mmPoids 200 gF2-303 / F2-304 F2-301 / F2-302IMPULSIONS F2-305 / F2-306 INTERRUPTEUR DIP 14OU ET Cav a lier 16 (P) no. 1 no. 221Insertado ON ON42Retirado OFF ON63/ON OFF63/OFF OFFTab. 2Graphique des im pul sions1Bou chon à vis2Vis3Cou ver cle4Entrées de câble5Pla que arriè re6Entrée de câble ex ter ne 7Sup port mon té par la pla -que arriè re 8Sup port mon té en coin/la -té ra le ment9Pla que à bor nes10 LED de l’a lar me in fra rou ge(vert)11 LED de l’a lar me hyper fré -quen ce (jau ne)12 LED de l’a lar me gé né ra leet de la mé moi re (rou ge)13Vis de ré gla ge de la sen si bi li té de l’in fra rou ge: tour ner dansle sens des ai gui lles d’u nemon tre pour aug men ter14Vis de ré gla ge de la sen si bi li té de l’hyper fré quen ce: tour nerdans le sens des ai gui lles d’u -ne mon tre pour aug men ter15 Ca va lier de dé sac ti va tion LED16 Ca va lier du comp teur d’im -pul sions17 Mi crop ho ne18Vis de ré gla ge de la sen si bi li té du mi crop ho ne: tour ner dansle sens des ai gui lles d’u nemon tre pour aug men ter19 Inte rrup teur anti-sa bo ta ge20 Mi cro rup teur DIPF2-303 / F2-304 F2-301 / F2-302IMPULSI F2-305 / F2-306 DIP-SWITCH 20OR AND Pon ti cel lo 16 (P) n. 1 n. 221Inserito ON ON42Rimosso OFF ON63/ON OFF63/OFF OFFTab. 2Programmazione impulsi.+Po w³¹cze niu za sil ania czuj ka ustab ili zuje siê po oko³o 60 se kund ach(do tyc zy mo deli: F2-303, F2-304, F2-305, F2-306). Faza sta bil iza cjibêd zie sy gnal izo wana ci¹g³ym œw iece niem siê czer won ej dio dy LED.TRYB PRACY "AND" Czuj ka wywo³a alarm wte dy, gdy oby dwa czuj -niki w ci¹gu 20 s wy gen eruj¹ za prog ramo wan¹ li czbê im puls ów (patrz ko -lumna AND - Tab. 2). Ten tryb pra cy do tyc zy mo deli F2-303, F2-304,F2-305, F2-306 oraz mo deli F2-301 i F2-302, je ¿eli seg ment owyprze³¹cznik dwu stan owy nr 5 znaj duje siê w po zyc ji "ON" (patrz li stwaDIP-swi tch 20).+Je den d³ugi im puls (trwaj¹cy 1 s) równie¿ wy gen eru je stan alarm owy.TRYB PRACY "AND/OR" (F2-301 / F2-302) Ten tryb pra cy uzys -kiwa ny jest po przez prze³¹cze nie seg ment owe go prze³¹czni ka dwu stan owe -go nr 5 w poz ycjê "OFF" (patrz li stwa DIP-swi tch 20). Czuj ka bêdz ie dzia³aætak samo jak w try bie AND oraz bêd zie rów nie¿ dzia³aæ sy tua cji, gdy je den zcz ujników zo stan ie za mas kowa ny lub bê dzie uszkod zony (OR). W tym przy -padku czuj ka wywo³a alarm wte dy, gdy dzia³aj¹cy czuj nik w ci¹gu 20 s wy gen -eru je za prog ramo wan¹ li czbê im puls ów (patrz ko lumna OR - Tab. 2).WY£¥CZANIE DIOD LED Dio dy LED mog¹ zos taæ wy³¹czo ne po -przez us uniêcie zwor ki 15 WT (dla mo deli: F2-303, F2-304, F2-305, F2-306) lub po przez prze³¹cze nie seg ment owe go prze³¹czni ka dwu stan owe go nr 4w poz ycjê "OFF" (patrz li stwa DIP-swi tch 20 – dla mo deli: F2-301 i F2-302).W£¥CZANIE PAMIÊCI (F2-301 / F2-302 / F2-303 / F2-304)Funk cja ta jest przy datna w za stos owa nia ch, w kt órych kil ka czu jek jestpod³¹czo nych do tej sa mej li nii do zor owej cen trali alarm owej. Je¿eli czuj ka za -syg nali zuje alarm do cen trali, wte dy po roz broj eniu sys temu œwi eciæ siê bêd -zie czer wona dio da LED wska zuj¹c dok³adne miej sce na rus zenia. Popo nown ym uzbroj eniu cen trali alarm owej pamiêæ alarmu zo stan ie ska sow anai czer wona dio da LED zga œnie. W celu w³¹cze nia funk cji pami êci nale ¿y:> po³¹czyæ za cisk [M] z ta kim za cis kiem wy jœc iowym cen trali alarm owej,który po uzbroj eniu cen trali uzys kuje po tenc ja³ masy (dla mo deli F2-303 iF2-304 oraz mo deli F2-301 i F2-302 je ¿eli seg ment owy prze³¹cznik dwu -stan owy nr 3 znaj duje siê w po zyc ji "ON" lub> po³¹czyæ za cisk [M] z ta kim za cis kiem wy jœc iowym cen trali alarm owej,który po uzbroj eniu cen trali ma wy sok¹ im pedancjê (dla mo deli F2-301 iF2-302 je ¿eli seg ment owy prze³¹cznik dwu stan owy nr 3 znaj duje siê w po -zyc ji "OFF" - (patrz li stwa DIP-swi tch 20).+Je ¿eli funk cja pami êci nie jest wy mag ana NIE WOLNO pod³¹czaæ za cis -ku [M] i prze³¹czaæ seg ment owe go prze³¹czni ka dwu stan owe go nr 3 wpoz ycjê "ON" (patrz li stwa DIP-swi tch 20). WY£¥CZANIE MIKROFALOWEJ (F2-301 / F2-302 / F2-303 / F2-304)W celu wy³¹cze nia de tekc ji mi krof alo wej na le¿y po³¹czyæ za cisk [MW] zta kim za cis kiem wy jœc iowym cen trali alarm owej, który po roz broj eniu cen -trali uzys kuje po tenc ja³ masy.PRÓBA WYKRYWANIA RUCHU Nale¿y wywo³aæ ruch w ob szar zechro nion ym, stop niowo zwiê kszaj¹c po ziom czu³oœci (na le¿y u¿yæ tr ymerów 13 i 14) do mo mentu, w kt órym dio dy LED zie lona i ¿ó³ta bêd¹ syg nal izowaæwy kryc ie ru chu.IDENTYFIKACJA PODZESPO£ÓWDANE TECHNICZNECz êstotliwoœci mi krof al:F2-302 / F2-304 / F2-306F2-301 / F2-303 / F3-305 10,515 GHz10,525 GHzZa siêg 12 mZa sil anie 12 Vdc ± 3 VPo bór pr¹du: F2-301 / F2-302F2-303 / F2-304F2-305 / F2-30610 mA (maks. 20 mA)10 mA (maks. 30 mA)12 mA (maks. 30 mA)Styk alarm owy N.C. (typu A)Im puls alarm owy 0,5 sPrze³¹cznik antysabota¿owy N.C.Czu³oœæ mi krof onu (F2-305 / F2-306) -24 dB (300 do 4000 Hz)Za kres tem per atur -10 do 40 °CKla sa ochrony IP 40Wy miary (sz erok oœæ x wy soko œæ x g³êb okoœæ) 60*105*44 mmWaga 200 gF2-303 / F2-304 F2-301 / F2-302IMPULSY F2-305 / F2-306 DIP-SWITCH 20OR AND Zwor ka 16 (P) nr 1 nr 221Za³o¿ona ON ON42Usuniêta OFF ON63/ON OFF63/OFF OFFTab. 2Tabela impulsówFCC Compliance StatementCAUTION: Changes or modifications not expressly approved by Digital Security Controls could void your authority to use this equipment.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and(2) This device must accept any interference received, including interference that may cause undesired operationThis Class B digital apparatus meets all requirements of the ICES-003 Cet appareil numérique de la classe B respecte toutes les exigence du ICES-003.1Nak³adka na œru bê2Œruba3Po krywa4Otwory do wpro wad zania prze wod ów5P³yta tyl na6Otw ór do wpro wad zania prze wod -ów roz prow adz anych zew nêtr znie7Wspor nik do monta ¿u na p³ycie tyl nej8Wspor nik do monta ¿u wpo³o¿eniu naro¿ nym/bocz nym9P³yta z za cis kami po³¹cze niow ymi10 Dio da LED alarmu de tekt orapod czerw ieni (zie lona)11 Dio da LED alarmu de tekt orami krof alo wego (¿ó³ta)12 Dio da LED pam iêci i alarmuogóln ego (czer wona)13Try mer ustaw iania czu³oœci de -tekt ora pod czerw ieni: zwi êksza nie czu³oœci po przez ob rót zgod nie zru chem ws kazówek ze gara14Try mer ustaw iania czu³oœci de -tekc ji mi krof alo wej: zw iêks zan ie czu³oœci po przez ob rót zgod niez ru chem ws kazówek ze gara15 Zwor ka blo kow ania diod alarm -owy ch LED16 Zwor ka licz nika impu lsów17 Mi krof on18Try mer ustaw iania czu³oœci mi -krof onu: zw iêks zan ie czu³oœcipo przez ob rót zgod nie z ru -chem ws kazówek ze gara19 Prze³¹cznik antysabota¿owy20 Seg ment owy prze³¹cznik dwu -stan owyAT FI DE LU PT SE CZ EE HU SK!ISTISD23F2-300 0.0 160106 V10Part Number 29007194R001](https://usermanual.wiki/Tyco-Safety-Canada/06F23X/User-Guide-625253-Page-2.png)