Tyco Safety Canada 06RFK55XX4 ASK Receiver User Manual 29007261R001 PK55xx RFK55xx 5 0 INIS EN

Digital Security Controls Ltd. ASK Receiver 29007261R001 PK55xx RFK55xx 5 0 INIS EN

Contents

Users Manual

PK55XX
RFK55XX-433
WARNING: Please refer to the System Installation Man-
ual for information on limitations regarding product use and
function and information on the limitations as to liability of the
manufacturer.
NOTE: These instructions shall be used in conjunction with
the system Installation Manual of the Control Panel with which
this equipment is intended to be used.
Installation Instructions
The PK55XX\RFK55XX keypads can be used on security systems with
up to 64 zones. These keypads are compatible with the following
DSC security systems:
The RFK55XX keypads combine a standard PC5132 receiver with the
respective PK55XX keypad.
Specifications
Voltage rating: 12VDC nominal
Connects to control panel via 4-wire Keybus
1 keypad zone input/PGM output*
Current draw: 50mA (standby) /125mA (maximum)
Optional tamper version
5 programmable function keys
Ready (green LED), Armed (red LED), Trouble (yellow LED), AC
(green LED)
Low temperature sensor
Frequency: 433.92MHz (RFK55XX-433 Only)
Upto 32 wireless zones (RFK55XX Only)
NOTE: * Zone not to be programmed as Fire type or 24h type.
Unpacking
The Power keypad package includes the following parts:
One Power keypad • Keypad inner door labels
Four mounting screws • 1 tamper switch
2 end-of-line resistors 1 Installation Instructions
Mounting
You should mount the keypad where it is accessible to designated
points of entry and exit. Once you have selected a dry and secure
location, perform the following steps to mount the keypad.
1. Removing the keypad from the backplate for the first time.
(a) Position the keypad as indicated below, insert screwdriver and
rotate.
2. Removing the keypad from backplate once mounted.
(a) Open door, holding it 90° to the keypad, as shown below.
(b) Insert screwdriver into slot located under the door hinge and
rotate the screwdriver.
Wiring
1.Before wiring the unit, ensure that all power (AC transformer and
battery) is disconnected from the control panel.
2.Connect the four Keybus wires from the control panel (red, black,
yellow and green) to the keypad terminals. Refer to diagram:
3.If programmed as an input, you can connect a device - such as a
door contact - to the ‘P/Z’ terminal of the keypad. This eliminates
the need to run wires back to the control panel for the device. To
connect the zone, run one wire from the device to the ‘P/Z’ terminal
and the other wire from the device to the B (black) terminal. For
powered devices, run the red wire to the R (positive) terminal and
the black wire to the B (negative) terminal. When using end of line
supervision, connect the zone according to one of the configurations
outlined in your system’s Installation Manual.
4.If the ‘P/Z’ terminal is programmed as an output, the output fol-
lows the PGM programmed in Section [080]. A small relay, buzzer
or other DC operated device may be connected between the positive
supply voltage and the ‘P/Z’ terminal (maximum load is 50mA).
Applying Power
Once all wiring is complete, apply power to the control panel:
1. Connect the battery leads to the battery.
2. Connect the AC transformer.
For more information on control panel power specifications, see the
control panel Installation Manual.
Programming the Keypad
There are several programming options available for the keypad.
These are described below. Programming the keypad is similar to
programming the rest of the system. When you are in the keypad
programming sections, the keypad will display which options are
turned on along the top of the display. To turn an option on or off,
press the number correspond-
ing to the option on the num-
ber pad. The numbers of the
options that are currently
turned ON will be displayed.
For example, if options 1 and
4 are on, the display will look
like this on the different key-
pad displays:
For information on program-
ming the rest of your security
system, please refer to your system’s Installation Manual.
Programming LCD Labels
All LCD programming is done per keypad. If more than one LCD key-
pad is present on the system, labels programmed at one keypad can
be broadcast to all other LCD keypads. Perform the following proce-
dure in order to broadcast labels:
Step 1 - Program one LCD keypad completely.
Step 2 - Make sure all LCD keypads are connected to the Keybus.
Step 3 - Enter Installer’s Programming, then enter section [998] at
the keypad that was programmed. The keypad will now broadcast
all the information programmed to all the other LCD keypads on the
system.
Step 4 - When the keypad is finished press the [#] key to exit.
NOTE: Label brodcast from this keypad is only compatible with other
PK5500 and RFK5500 Keypads.
Installation Instructions
123
456
78
0
*
#
9
RFK5500
PK5500
123
456
78
0
*
#
9
RFK5501
PK5501
123
456
78
0
*
#
9
RFK5508
PK5508
123
456
78
0
*
#
9
RFK5516
PK5516
•PC580/PC585 •PC1555MX/PC1565 •PC1616/PC1832/PC1864
•PC5005 •PC5008 •PC5010
•PC5015 •PC5016 •PC5020
Disasembling
(Free-standing)
1. Insert the screwdriver into
slot at an angle and push
3. Repeat steps
1. and 2. for
left side
2. Rotate 90°
3. Repeat steps 1.
and 2. for right sid
e
Disasembling
(Wall-Mounted)
1. Insert the screwdriver into
slot at an angle and push
2. Rotate 90°
PK55XX\RFK55XX
RED
BLK
YEL
GRN
To zone or
PGM out
p
ut
R
B
Y
G
P/Z
FCC Compliance Statement
Caution: Changes or modifications not expressly approved by Digital
Security Controls could void your authority to use this equipment.
This equipment generates and uses radio frequency energy and if not installed
and used properly, in strict accordance with the manufacturer’s instructions,
may cause interference to radio and television reception. It has been type tested
and found to comply with the limits for Class B device in accordance with the
specifications in Subpart “B” of Part 15 of FCC Rules, which are designed to
provide reasonable protection against such interference in any residential
installation. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause interference to television or
radio reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the
following measures:
• Re-orient the receiving antenna
• Relocate the alarm control with respect to the receiver
• Move the alarm control away from the receiver
• Connect the alarm control into a different outlet so that alarm control and receiver
are on different circuits.
If necessary, the user should consult the dealer or an experienced radio/televi-
sion technician for additional suggestions. The user may find the following
booklet prepared by the FCC helpful: “How to Identify and Resolve Radio/
Television Interference Problems”. This booklet is available from the U.S.
Government Printing Office, Washington, D.C. 20402, Stock # 004-000-
00345-4.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du
Canada.
IC:160A-RFK55XX4
The term IC before the radio certification number signifies that the Industry
Canada technical specifications were met.
Operating Instructions shall be made available to the user.
©2006 Digital Security Controls, Toronto, Canada • www.dsc.com
Tech. Support: 1-800-387-3630 (Canada, US), 905-760-3036
Printed in Canada
29007261R001
41
Toggle Options
1 _ _ 4 _ _ _ _
Language Programming (PK5500\RFK5500 Only)
Hold (<>) keys for 2 seconds to enter language programming,
scroll to the desired language and Press [*] to select.
Enrolling the Keypad
The keypad will need to be assigned to a partition and slot if supervi-
sion or keypad zones are being used. Keypad assignments and key-
pad option programming must be done at each keypad individually.
The 1st digit of keypad assignment is used to determine partition
assignment (1 to 8). If partitioning is not used, enter [1]. For Global
Keypads, enter [0].
NOTE: LED and ICON keypads cannot be programmed as Global
Keypads
The 2nd digit of keypad assignment is used to determine slot assign-
ment for keypad supervision. Each keypad will be assigned a differ-
ent slot number from 1 to 8. PK5500 and RFK 5500 LCD keypads
come defaulted in slot 8. If LCD keypads are used one LCD keypad
must remain in slot 8.
NOTE: The RFK55XX enrolls as two modules:
1 = keypad section of the RFK55XX
17 = receiver section of the RFK55XX
NOTE: Deleting all wireless devices from the RFK55XX or
defaulting the RFK55XX will cause a supervisory fault.
Enter the following at each keypad installed on the system:
1. Enter Installer Programming by pressing [*][8][Installer’s Code]
2. Press [000] for Keypad Programming
3. Press [0] for Partition and Slot Assignment
4. Enter the 1st digit (0 to 8 for partition assignment)
5. Enter the 2nd digit (1 to 8 for slot assignment supervision)
6.Press the [#] key twice to exit programming.
7.After assigning all keypads, perform a supervisory reset by entering
[*][8][Installer’s Code][902] and wait for 60 seconds.
8.Press the [#] key to exit programming after 60 seconds.
Keypad Enrollment
Enter keypad programming by pressing [*][8][Installer’s Code][000].
[0] Partition / Slot Assignment
[1]-[5] Function Key Assignment
Keypad Function Keys
Please see your system installation manual for a complete list of all the
function key options available for your system.
Programming Labels (PK5500\RFK5500 Only)
1.Enter Installers Programming. Enter the 3-digit section number for the label
to be programmed.
2.Use the arrow keys (<>) to move the underline bar underneath the letter
to be changed.
3.Press the number keys [1] to [9] corresponding to the letter you require. The
first time you press the number the first letter will appear. Pressing the
number key again will display the next letter.
Refer to the following chart:
4.When the required letter or number is displayed use the arrow keys (<>)
to scroll to the next letter.
5.When you are finished programming the Zone Label, press the [*] key, scroll
to “Save,” then press [*].
6.Continue from Step 2 until all Labels are programmed.
NOTE: Label Programming can also be accessed from the [*][6] User
Functions Menu
ASCII Characters
Keypad Programming
Enter keypad programming by pressing [*][8][Installer Code][*]
[001]-[064] Zone Label 1 to 64 (PK5500\RFK5500 Only)
ex. For Zone 1 enter section [001], for Zone 2 enter section [002] etc.
Default: “Zone 1” - “Zone 64
[065] Fire Alarm Label (28 Characters) (PK5500\RFK5500 Only)
Default:“Fire Zone”
[066] Fail to Arm Event Message (PK5500\RFK5500 Only)
Default: “System Has Failed to Arm”
[067] Alarm When Armed Event Message (PK5500\RFK5500 Only)
Default: “Alarm Occurred While Armed < >”
[071] First User Display Mask
[072] Second User Display Mask
[073] Download LCD Message Duration (PK5500\RFK5500 Only)
Default: 003 I_____I_____I_____I (Valid entries are 000-255), 000=Unlimited Message Disp.
This number represents the number of times the Downloaded message is
cleared by pressing any key while the message is up after timeout).
[074] Key Options
[076] First Keypad Options
[077] Second Keypad Options
[080] PGM Terminal 1
D e f a ult: 01 I_______I _______I P GM Outp ut Nu mber
[101]-[108] Partition Labels (PK5500\RFK5500 Only)
ex. For Partition 1 enter section [101], for Partition 2 enter section [102] etc.
NOTE: Partition 1 Label is also used as the System Label
[120]-[151] Command Output Labels (PK5500\RFK5500 Only)
Default: “Command_O/P_1” - “Command_O/P_4”
For Partition 1 Command O/P 1 to 4 enter [120] to [123]
For Partition 2 Command O/P 1 to 4 enter [124] to [127]
For Partition 3 Command O/P 1 to 4 enter [128] to [131]
For Partition 4 Command O/P 1 to 4 enter [132] to [135]
For Partition 5 Command O/P 1 to 4 enter [136] to [139]
For Partition 6 Command O/P 1 to 4 enter [140] to [143]
For Partition 7 Command O/P 1 to 4 enter [144] to [147]
For Partition 8 Command O/P 1 to 4 enter [148] to [151]
[201]-[264] Door Chime Sound Programming
You can program the keypad to make upto four different door chime sounds
for individual zones.
ex. For Zone 1 enter section [201], for Zone 2 enter section [202] etc.
[995] Reset Keypad Options to Factory Default
[996] Label Default (PK5500\RFK5500 Only)
[997] View Software Version (PK5500\RFK5500 Only)
[998] Initiate Global Label Broadcast (PK5500\RFK5500 Only)
[999] Reset Keypad EEPROM to Factory Defaults
Digit Option Valid Range Default
1st Partition Assignment (0=Global Keypad) 0 to 8 1 I_____I
2nd Slot Assignment 1 to 8 LED\ICON=1
LCD=8 I_____I
Function Key Button Valid Range Default Function
[1] Function Key 1
Assignment 00 to 32 03 Stay Arm I_____I_____II
[2] Function Key 2
Assignment 00 to 32 04 Away Arm I_____I_____II
[3] Function Key 3
Assignment 00 to 32 06 Chime On/Off I_____I_____II
[4] Function Key 4
Assignment 00 to 32 14 Command
Output 2 I_____I_____II
[5] Function Key 5
Assignment 00 to 32 16 Quick Exit I_____I_____II
[00] - Null [10] - Alarm Memory [23] - Bypass Recall
[01] - Partition 1 Select [11] - User Programming [24] - Bypass Group Recall
[02] - Partition 2 Select [12] - User Functions [26] - Time & Date Program
[03] - Stay Arm [13] - Command Output 1 [27] - Partition 3 Select
[04] - Away Arm [14] - Command Output 2 [28] - Partition 4 Select
[05] - No Entry Arm [16] - Quick Exit [29] - Partition 5 Select
[06] - Chime On/Off [17] - Activate Stay/Away [30] - Partition 6 Select
[07] - System Test [19] - Command Output 3 [31] - Partition 7 Select
[08] - Bypass Mode [21] - Command Output 4 [32] - Partition 8 Select
[09] - Trouble Display [22] - Activate Camera
[1] - A, B, C, 1 [5] - M, N, O, 5 [9] - Y, Z, 9,0
[2] - D, E, F, 2 [6] - P, Q, R, 6 [0] - Space
[3] - G, H, I, 3 [7] - S, T, U, 7
[4] - J, K, L, 4 [8] - V, W, X, 8
Section Zone Label
[001] to [064] 1 to 64 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
[065] I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
[066] I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
[067] I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
Default Option ON OFF
ON I_____I 1 Hold [P]anic Key prompt ON Hold [P]anic Key prompt OFF
ON I_____I 2 Auto-arm Control/Time prompt ON Auto-arm Control/Time prompt OFF
ON I_____I 3 Quick Arm prompt ON Quick Arm prompt OFF
O N I_____I 4 In te rior Arm pro mpt ON I n t erio r Arm pro mpt O FF
OFF I_____I 5 Quick Exit prompt ON Quick Exit prompt OFF
OFF I_____I 6 Thermostat Control prompt ON Thermostat Control prompt OFF
OFF I_____I 7 ACK All Trouble Prompt ON ACK All Trouble Prompt OFF
OFF I_____I 8 Music Input prompt ON Music Input prompt OFF
Default Option ON OFF
O N I_____I 1 U s er-i nit iate d C all- up prom pt ON User-initiated Call-up prompt OFF
O F F I_____I 2 Fo r Futur e U s e
OFF I_____I 3 Walk Test prompt ON Walk Test prompt OFF
ON I_____I 4 Command Output#1 prompt ON Command Output#1 prompt OFF
ON I_____I 5 Command Output#2 prompt ON Command Output#2 prompt OFF
OFF I_____I 6 Command Output#3 prompt ON Command Output#3 prompt OFF
OFF I_____I 7 Command Output#4 prompt ON Command Output#4 prompt OFF
O F F I_____I 8 Fo r Futur e U s e
Default Option ON OFF
O N I_____I 1 [F]ire Key Enabled [F]ire Key Disabled
O N I_____I 2 [A]uxiliary Key Enabled [A]uxiliary Key Disabled
O N I_____I 3 [P]anic Key Enabled [P]anic Key Disabled
O F F I_____I 4 - 8 For Future Use
Default Opt. ON OFF
O N I_____I 1 D is pl ay Cod e w hen Pr og ra mming Display “Xs” when Programming
O N I_____I 2 L o ca l C l oc k D is p l a y O N L oca l C loc k D isp la y OF F
O F F I_____I 3 L o c a l C l o c k D i s p l a y s 2 4 - h r Ti m e L o c a l Cl oc k D i s p l a y s AM /PM
ON I_____I 4 Auto Alarm Memory Scroll Enabled Auto Alarm Memory Scroll Disabled
OFF I_____I 5 Local Display of Temperature ON Local Display of Temperature OFF
ON I_____I 6 Bypass Options prompt ON Bypass Options prompt OFF
O F F I_____I 7 F o r F u t u r e U s e
OFF I_____I 8 Auto-Scroll Open Zones ON Auto-Scroll Open Zones OFF
Default Opt. ON OFF
ON I_____I 1 Chime Enabled for Zone Openings Chime Disabled for Zone Openings
ON I_____I 2 Chime Enabled for Zone Closings Chime Disabled for Zone Closings
OFF I_____I 3 5th Terminal is Keypad PGM Output 5th Terminal is Keypad Zone Input
O F F I_____I 4 F o r F utu r e Use
OFF I_____I 5 Power LED Enabled Power LED Disabled
O N I_____I 6 Po w e r L E D i n d i c a t e s A C p r esent Power LED indicates AC absent
ON I_____I 7 Alarms always Displayed When Armed Alarms not Displayed When Armed
OFF I_____I 8 Low Temperature Warning Enabled Low Temperature Warning Disabled
Section Partition Label
[101] to [108] 1 to 8 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
Section Part. Cmd.
Output Label
[120] to [151] 1 to 8 1 to 4 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
Default Option ON OFF
ON I_____I 1 6 Beeps Disabled
OFF I_____I 2 “Bing-Bing” Sound Disabled
OFF I_____I 3 “Ding-Dong” Sound Disabled
OFF I_____I 4 Alarm Tone Disabled
OFF I_____I 5-8 For Future Use
Wireless Integration (RFK55XX Only)
Compatible Wireless Devices (RFK55XX-433 Only)
The RFK55XX can receive signals from the following devices:
Downloading
The RFK55XX product has an integrated wireless receiver. When
downloading to this keypad, please select the PC5132-433 v5.0 file.
DLS2002 and greater must be used in order to have the capability of
downloading to this keypad.
Testing Wireless Devices
1. Temporarily put the wireless devices in the places you want to
mount them.
2. At a system keypad, enter [*][8][Installer Code].
3. Enter programming section [904], then enter the two digit zone
number.
NOTE: If global placement test is enabled enter [01] to test all zones.
4. Activate the device being tested until a result is displayed on the
keypad or sounded by the keypad or bell
Activate the device until you get 3 good results in a row. Wait 10 sec-
onds between each test on the same device. You may mount wireless
devices where results were good.
Devices indicating a bad result must be moved to another location.
You may only have to move the device a few inches to correct a bad
result.
NOTE: Do not mount any device where a “bad” test result was indi-
cated.
Testing Portable Device Reception
To test portable devices (e.g., WS4938, WS4939) press the button(s)
at several different points in the installation, to confirm the coverage
area. If these devices do not operate from all points in the installa-
tion, you will need to move the RFK55XX.
Wireless Programming (RFK55XX Only)
Enter Wireless programming by pressing [*][8][Installer’s Code][804]
[01]-[32] Wireless Device Serial Number
Zone Serial Numbers Default = 000000
[41]-[56] Wireless Key Serial Number
Wireless Key Serial Numbers Default = 000000
[61]-[68] Wireless Function Key Options
Wireless Key Functions
[69] Wireless Keys (1-16) Partition Assignments
Default = 01
[81] Wireless supervisory Window
Default: [NA] 96 = 24 hours / [EU] 10 =2.5 hours I_____I_____I
The window is programmed in 15 minute increments. Valid entries are
10 to 96, equal to 2.5 to 24 hours.
[82]-[85] Zone Device Supervision Options
[90] Other Options
NOTE: For UL Listed installations, the RF Jam feature must be enabled.
NOTE: For DD243 instllations, the RF delinquency feature should be
enabled.
NOTE: Supervision must be enabled for RF Delinquency.
[93] RF Jam Detect Zone
Default: 00 I_____I_____I
Select an unused zone that will be set to the tamper state when a jam-
ming signal is detected (valid entries = 01 - 32, 00 = No RF Jam tone
selected).
Replacing Wireless Device Batteries
1. Remove the cover of the device from its backplate. This creates a
tamper condition on the zone.
2. Refer to the battery installation instructions on the Installation
Sheet of each component. Be sure to note the proper orientation of
the batteries as you install them.
3. When the fresh batteries are in place, re-attach the cover to the
backplate. The tamper is restored and the zone sends a battery trou-
ble restoral signal to the receiver. The battery trouble is now clear and
the device should function normally.
NOTE: When batteries in one device need to be replaced, the batteries in
all devices should be replaced at the same time.
Troubleshooting
1. When I enter the 2-digit zone number when adding a wire-
less device, the keypad gives me a long beep.
You cannot enter ESNs unless the RFK55XX is properly connected to
the Keybus.
2. I have entered the ESN for the device but when I violate the
device, the zone does not show open on the keypad.
Check the following:
Ensure the ESN has been entered correctly
Ensure that the zone is enabled for the partition (if partition pro-
gramming is used).
Ensure that the wireless zone is not assigned to a zone used by
PC5108 modules, an on-board zone or a keypad zone.
Ensure that the zone is programmed for something other than “Null
Operation and that the wireless zone attribute is turned on.
3. When I try a module placement test I get no result or “Bad”
results.
Check the following:
Verify that you are testing the correct zone
Verify that the correct ESN was entered when the device was enrolled
Verify that the device is in range of the RFK55XX. Try testing the
device in the same room as the receiver.
Confirm that the RFK55XX is properly connected to the Keybus.
Check that you are testing the zone correctly. Refer to the instruc-
tions that came with the zone.
Check that the batteries are working and installed correctly.
Look for large metal objects that may be preventing the signal from
reaching the RFK55XX.
The device must be located where consistent “Good” results are
obtained. If several devices show “Bad” results, or if panic pendants
and wireless keys operate inconsistently, move the receiver.
4. The LED on the motion detector does not turn on when I
walk in front of the unit.
The LED on the motion detector is for walk test purposes only. See
your WLS904-433/WLS904P(L)-433 Instruction Sheet for walk test
instructions.
•WLS904(P)L-433 Pet Immune PIR •WLS912L-433 Glass Break Detector
•WS4965 •WLS914-433 Pet Immune PIR
•WS4938 Panic Button •WLS925L-433 Mini Door/Window Contact
•WS4916 Smoke Detector •WS49X9 Wireless Keys
Result LED Keypad LCD Keypad Bell/Buzzer
Good Light 1 ON Steady Good 1 Beep/Squawk
Bad Light 3 ON Steady Bad 3 Beeps/Squawks
[01] Zone 1 I_____I_____I_____I_____I_____I_____I [17] Zone 17 I_____I_____I_____I_____I_____I_____I
[02] Zone 2 I_____I_____I_____I_____I_____I_____I [18] Zone 18 I_____I_____I_____I_____I_____I_____I
[03] Zone 3 I_____I_____I_____I_____I_____I_____I [19] Zone 19 I_____I_____I_____I_____I_____I_____I
[04] Zone 4 I_____I_____I_____I_____I_____I_____I [20] Zone 20 I_____I_____I_____I_____I_____I_____I
[05] Zone 5 I_____I_____I_____I_____I_____I_____I [21] Zone 21 I_____I_____I_____I_____I_____I_____I
[06] Zone 6 I_____I_____I_____I_____I_____I_____I [22] Zone 22 I_____I_____I_____I_____I_____I_____I
[07] Zone 7 I_____I_____I_____I_____I_____I_____I [23] Zone 23 I_____I_____I_____I_____I_____I_____I
[08] Zone 8 I_____I_____I_____I_____I_____I_____I [24] Zone 24 I_____I_____I_____I_____I_____I_____I
[09] Zone 9 I_____I_____I_____I_____I_____I_____I [25] Zone 25 I_____I_____I_____I_____I_____I_____I
[10] Zone 10 I_____I_____I_____I_____I_____I_____I [26] Zone 26 I_____I_____I_____I_____I_____I_____I
[11] Zone 11 I_____I_____I_____I_____I_____I_____I [27] Zone 27 I_____I_____I_____I_____I_____I_____I
[12] Zone 12 I_____I_____I_____I_____I_____I_____I [28] Zone 28 I_____I_____I_____I_____I_____I_____I
[13] Zone 13 I_____I_____I_____I_____I_____I_____I [29] Zone 29 I_____I_____I_____I_____I_____I_____I
[14] Zone 14 I_____I_____I_____I_____I_____I_____I [30] Zone 30 I_____I_____I_____I_____I_____I_____I
[15] Zone 15 I_____I_____I_____I_____I_____I_____I [31] Zone 31 I_____I_____I_____I_____I_____I_____I
[16] Zone 16 I_____I_____I_____I_____I_____I_____I [32] Zone 32 I_____I_____I_____I_____I_____I_____I
[41] Key 1 I_____I_____I_____I_____I_____I_____I [49] Key 9 I_____I_____I_____I_____I_____I_____I
[42] Key 2 I_____I_____I_____I_____I_____I_____I [50] Key 10 I_____I_____I_____I_____I_____I_____I
[43] Key 3 I_____I_____I_____I_____I_____I_____I [51] Key 11 I_____I_____I_____I_____I_____I_____I
[44] Key 4 I_____I_____I_____I_____I_____I_____I [52] Key 12 I_____I_____I_____I_____I_____I_____I
[45] Key 5 I_____I_____I_____I_____I_____I_____I [53] Key 13 I_____I_____I_____I_____I_____I_____I
[46] Key 6 I_____I_____I_____I_____I_____I_____I [54] Key 14 I_____I_____I_____I_____I_____I_____I
[47] Key 7 I_____I_____I_____I_____I_____I_____I [55] Key 15 I_____I_____I_____I_____I_____I_____I
[48] Key 8 I_____I_____I_____I_____I_____I_____I [56] Key 16 I_____I_____I_____I_____I_____I_____I
Function
Key 1 Default Function
Key 2 Default Function
Key 3 Default Function
Key 4 Default
[61] Partition 1 I_____I_____II 03 I_____I_____II 04 I_____I_____II 27 I_____I_____II 30
[62] Partition 2 I_____I_____II 03 I_____I_____II 04 I_____I_____II 27 I_____I_____II 30
[63] Partition 3 I_____I_____II 03 I_____I_____II 04 I_____I_____II 27 I_____I_____II 30
[64] Partition 4 I_____I_____II 03 I_____I_____II 04 I_____I_____II 27 I_____I_____II 30
[65] Partition 5 I_____I_____II 03 I_____I_____II 04 I_____I_____II 27 I_____I_____II 30
[66] Partition 6 I_____I_____II 03 I_____I_____II 04 I_____I_____II 27 I_____I_____II 30
[67] Partition 7 I_____I_____II 03 I_____I_____II 04 I_____I_____II 27 I_____I_____II 30
[68] Partition 8 I_____I_____II 03 I_____I_____II 04 I_____I_____II 27 I_____I_____II 30
[00] - Null [07] - System Test [21] - Command Output 4
[03] - Stay Arm [13] - Command Output 1 [27] - Disarm
[04] - Away Arm [16] - Quick Exit [29] - Auxiliary Alarm
[05] - No Entry Arm [17] - Activate Stay/Away [30] - Panic Alarm
[06] - Chime On/Off [19] - Command Output 3
Key 1 I_____I_____II Key 5 I_____I_____II Key 9 I_____I_____II Key 13 I_____I_____II
Key 2 I_____I_____II Key 6 I_____I_____II Key 10 I_____I_____II Key 14 I_____I_____II
Key 3 I_____I_____II Key 7 I_____I_____II Key 11 I_____I_____II Key 15 I_____I_____II
Key 4 I_____I_____II Key 8 I_____I_____II Key 12 I_____I_____II Key 16 I_____I_____II
Default
ON
[82]
Zone
Supervision
ON/OFF
[83]
Zone
Supervision
ON/OFF
[84]
Zone
Supervision
ON/OFF
[85]
Zone
Supervision
ON/OFF
O p ti o n 1 1 I_____I 9 I_____I 1 7 I_____I 2 5 I_____I
O p ti o n 2 2 I_____I 1 0 I_____I 1 8 I_____I 2 6 I_____I
O p ti o n 3 3 I_____I 1 1 I_____I 1 9 I_____I 2 7 I_____I
O p ti o n 4 4 I_____I 1 2 I_____I 2 0 I_____I 2 8 I_____I
O p ti o n 5 5 I_____I 1 3 I_____I 2 1 I_____I 2 9 I_____I
O p ti o n 6 6 I_____I 1 4 I_____I 2 2 I_____I 3 0 I_____I
O p ti o n 7 7 I_____I 1 5 I_____I 2 3 I_____I 3 1 I_____I
O p ti o n 8 8 I_____I 1 6 I_____I 2 4 I_____I 3 2 I_____I
Default Option ON OFF
O FF I_____I 1 - 4 F or Futu r e U s e
O F F I_____I 5 RF Delinquency Disabled RF Delinquency Enabled
O F F I_____I 6 For Future Use
O F F I_____I 7 RF Jam Detect Disabled RF Jam Detect Enabled
OFF I_____I 8 Global Placement Test Individual Placment Test
Notes Notes Notes Notes Keypad Display Symbols Limited Warranty
Digital Security Controls warrants that for a period of 12 months from the
date of purchase, the product shall be free of defects in materials and work-
manship under normal use and that in fulfilment of any breach of such war-
ranty, Digital Security Controls shall, at its option, repair or replace the
defective equipment upon return of the equipment to its repair depot. This
warranty applies only to defects in parts and workmanship and not to dam-
age incurred in shipping or handling, or damage due to causes beyond the
control of Digital Security Controls such as lightning, excessive voltage,
mechanical shock, water damage, or damage arising out of abuse, alteration
or improper application of the equipment.
The foregoing warranty shall apply only to the original buyer, and is and
shall be in lieu of any and all other warranties, whether expressed or implied
and of all other obligations or liabilities on the part of Digital Security Con-
trols. Digital Security Controls neither assumes responsibility for, nor autho-
rizes any other person purporting to act on its behalf to modify or to change
this warranty, nor to assume for it any other warranty or liability concerning
this product.
In no event shall Digital Security Controls be liable for any direct, indirect or
consequential damages, loss of anticipated profits, loss of time or any other
losses incurred by the buyer in connection with the purchase, installation or
operation or failure of this product.
Warning: Digital Security Controls recommends that the entire system be com-
pletely tested on a regular basis. However, despite frequent testing, and due to,
but not limited to, criminal tampering or electrical disruption, it is possible for
this product to fail to perform as expected.
Important Information:Changes or modifications not expressly approved by
Digital Security Controls could void the users authority to operate this equip-
ment.
1Fire – Indicates that there are fire alarms in memory.
2 Memory – Indicates that there are alarms in memory.
3 Ready Light (green) – If the Ready light is on, the system is
ready for arming.
4 Armed Light (red) – If the Armed light is on, the system has
been armed successfully.
5 System Trouble – Indicates that a system trouble is active.
6AC – Indicates that AC is present at the main panel.
7 Program – indicates that the system is in Installer’s Program-
ming, or the keypad is busy.
8 Bypass – Indicates that there are zones automatically or man-
ually bypassed.
9 For Future Use
10 Arm Mode – Indicates the mode the panel is armed in.
Stay – Indicates that the panel is armed in the Stay Mode. It
will turn on at the beginning of the Exit Delay
Away – Indicates that the panel is armed in the Away
Mode. It will turn on at the beginning of the Exit Delay
11 Chime – This icon turns on when the Chime function key is
pressed to enable Door Chime on the system. It will turn off
when the chime function key is pressed again to disable Door
Chime.
12 Open – This icon is used with clock digits 1 and 2 to indicate
violated zones (not alarm) on the system. When zones are
opened, the OPEN icon will turn on, and 7 segment displays 1
and 2 will scroll through the violated zones.
12
3
4
5
6
7
8
12 9
10
11
12 7
8

Navigation menu