Tyco Safety Canada 12WIFI422SCW WiFi Module for DSC Impassa Alarm System User Manual DRAFT 29008546R001 WIFI422SCW INIS ENG ONLY

Digital Security Controls Ltd. WiFi Module for DSC Impassa Alarm System DRAFT 29008546R001 WIFI422SCW INIS ENG ONLY

user - installation manual

WIFI422SCW MODULE INSTALLATION SHEETIntroductionThe WIFI422SCW module provides a wireless link from the host security control panel tothe C24 Interactive gateway. This manual provides installation and setup information forWiFi422SCW only. Features & SpecificationsCompatibilityThis module is compatible with the following SCW control panels: SCW9055-SM-433,SCW9055D-SM-433, SCW9055G-SM-433, SCW9055I-SM-433, SCW9057-SM-433,SCW9057D-SM-433, SCW9057G-SM-433, SCW9057I-SM-433.Installation and WiringInsert WIFI422SCW module into the SCW905X backplate. Refer to Table 1 below forwiring details.Table 1:  WIFI422SCW Module Wiring ConnectionsFigure 1: WIFI422SCW Module WiringSetup & ProgrammingThe WIFI422SCW module receives power from the control panel AUX output and itcommunicates via the RS-422 interface on the 3G2055-SM-NA or TL2553G-SM-NAcommunicators.1. Enter section [851][920]. • The communicator will send a command to initiate Wi-Fi Protected Setup (WPS).• The message “WPS Success” is displayed when setup is complete.PGM AttributePlease refer to the SCW9055/9057 Installation Manual to configure PGM1 to Pulse.  Thedefault configuration (5 seconds) is recommended.[920] Initiate Protected SetupUpon entering this section the WIFI422SCW module shall initiate WPS and connect tothe nearest Access Point (AP) also performing WPS. The LCD shall display “WPS Enroll-ment in Progress”.• Upon failure of enrollment, the LCD shall display “WPS Enrollment Failure”.• Upon successful of enrollment, the LCD shall display “WPS Enrollment Success”.NOTE: If you exit this section, all Wi-Fi sections are blocked until WPS is eithersuccessful or has failed. The longest possible lock out is 1 minute. NOTE: Communicator Option [663] must be 11, configured for Interactive overGateway. If this section is any other value, Wi-Fi sections are also blocked.[921] WIFI422SCW Module Factory DefaultDefault (99)Enter [00] to perform a factory default, this will disconnect the WiFi422SCW from theAccess Point. The installer must perform a WPS with the new Access Point in order toenroll the router.Once the Access Point is disconnected, the default SSID will display “X”.[922] SSID DisplayEnter section [851][922] to obtain the SSID of the currently enrolled Access Point.The keypad will display the SSID of the network that it is using. If the WiFi422SCW isnot connected to any Access Point, the keypad will display “X” to indicate the networkconnection has not been created. [923] Signal Strength DisplayEnter section [851][923] to view the Wi-Fi signal strength.Once in this section, the keypad will display the signal strength with respect to the AccessPoint it is currently using. If the WiFi422SCW is not associated with any Access Point,the Keypad will display “X------”NOTE: This section is available on the display of the control panel only.Table 2: Signal Strength DisplayTroubleshootingFCC/ICThis modular transmitter is labeled with its own FCC ID and IC number. When the mod-ule is installed inside the host device and the FCC ID/IC of the module is not visible thehost device shall display the provided label referring to the FCC ID and IC of the enclosedmodule. This label is shipped together with the module and it is the responsibility of theintegrator to apply it to the exterior of the enclosure as indicated below.FCC COMPLIANCE STATEMENTCAUTION: Changes or modifications not expressly approved by DSC could void your authority to use thisequipment.This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accor-dance with the manufacturer’s instructions, may cause interference to radio and television reception. It has beentype tested and found to comply with the limits for Class B device in accordance with the specifications in Sub-part “B” of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interfer-ence in anyresidential installation. However, there is no guarantee that interference will not occur in a particular installa-tion. If this equipment does cause interference to television or radio reception, which can be determined byturning the equipment off and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures:• Re-orient the receiving antenna• Relocate the alarm control with respect to the receiver• Move the alarm control away from the receiver• Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits.If necessary, the user should consult the dealer or an experienced radio/television technician for additional sug-gestions. The user may find the following booklet prepared by the FCC helpful: “How to Identify and ResolveRadio/Television Interference Problems”. This booklet is available from the U.S. Government Printing Office,Washington,D.C. 20402, Stock # 004-000-00345-4.This device complies with Part 15 of the FCC Rules and with Industry Canada license exempt RSS standard(s).Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may cause undesired operation. ““Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts delicence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doipas produire de brouil-lage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage estsusceptible d'en compromettre le fonctionnement.• RS-422 interface • Dimensions: 64mm × 24.71 mm• SSID indication (SCW variant) • Indoor range: 32m (120ft) • Signal strength indication • Outdoor range: 95m(300ft)• Reset via PGM • Power consumption: 66mA (max.) / 12V• SW WPS Setup • Humidity: 85%, non-condensing• WPA2 PSK • Wi-Fi Data Rate: 802.11 b/g • UART Serial Data Rate: 115200bpsFrom WIFI422SCW Module To SCW905X(D)(G)(I)Red Aux+ terminal block on the panelBlack Aux- terminal block on the panelBrown 1 I/O terminal block on the panelWhite Rx- terminal block on communicatorYellow Rx+ terminal block on communicatorBlue Tx - terminal block on communicatorGreen Tx+ terminal block on communicator+TX- +RX-GND1 I/O 2R   TR1  T1+AUX-ACWIFI422SCWSCW905XRED BLACKBROWN WHITEGREENBLUEYELLOWSignal Strength RSSI ValueNo signal Less than -85 1 Bar -85 to -762 Bars -75 to -663 Bars -65 to -564 Bars -55 to -465 Bars -45 and upTrouble  SolutionSignal strength is below 3 bars (see Table 2) Relocate the system until 3 bars or higher is observed.Error tone being generated / unable to enter WiFi422SCW section Check WiFi422SCW wiringPerform a power cycleWiFi422SCW unable to connect to APFCC/IC Label(SCW Approval Label)© 2012 Tyco International Ltd. and its Respective Companies. All Rights Reserved. Toronto, Canada  •  www.dsc.com Tech Support: 1-800-387-3630 (Canada, USA), 905-760-3000Printed in Canada29008546R001DRAFTIMPORTANT NOTE: To comply with FCC and Industry Canada RF exposure compliance requirements, the antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. Failing to comply with any of the above conditions would require new FCC/IC equipment authorization for the host device.  The WLAN module may only be used with host equipment (SCW905X control panels) as listed under section "Compatibility".

Navigation menu