Tyco Safety Canada 98SS12 User Manual 8
Digital Security Controls Ltd. 8
8
g; D. Cecic - osc Ltd. FOG 1D: “5396st M8912 Wireless AcuITY Glass Break Detector Instructions for Installation and Use “WORKING PAPER "“ Introduction The model WL5912 is a battery operated acoustic glass break sensor, designed to detect the sound produced by the shattering ol framed glass. Equipped with an RF transmitter, the WLSQ12 establishes a supervised. one-way communications link with the QODMHZ System Controller. The WLSS12 uses Dynamic Signal Processing‘ to provide accurate detection of Plate. Laminated, Wired and Tempered glass types, while rejecting common false alarm sounds. " Protected under US Patent 5, 675,320 Specificao‘ons 4,5V (three 'AA" Alkaline Batteries) 0°C - 50°C (32° F 122°F) 5% - 95% RH, non-condensing Operating Voltage Operating Environment Sensitivity: Glass Type Thickness Mlnlmum Level 1 led 2 Glass size (wa) Setting Setting Plate/Tempered 1/8"-l/4' 12’th zorr tort 3.6mm SOcrmGDcm 6m 3m “fired/Laminated 1/4' 1e'x18' 201i DO NOT use 5mm 46cmX4Gcn-r em Battery Guidelines and Installation Before installing batteries, please note the following guidelines: . The detector is designed to work with Evoready Alkaline Energiser "AA" batteries. Do not install any other type “No-name“ or generic brand batteries may not provide the best quality and dependability. - Always replace all three batteries at the same time. . When disposing of used batteries, follow the instructions and precautions printed on the batteries. Marry cities and communities have collerxion sites or services for used household batteries. Contact your municipal offices for infon'na/tion on the disposal of used batteries. To install the batteries, 1. Remove the detector from its mounting plate by holding the detector by its sides and pushing up as indicated in Figure xx. 2. Observe the correct polarity (see Figure xx). 34 Install the batteries negative (-) side first as shown in Figure xx. - CONFlDENTIAL : FOR INTERNAL USE ONLY— 10/23/98 . FCC ID F53988312 0. Cent: - osc Ltd. WL5912 Wireless ACUITY Glass Break Detector Instructions for lrlstallation and Use "WORKING PAPER "' Setting the DID-Switches The detector has two user-selectable jumper settings as shown in Figure xx: SW1 — Alarm Led enable/disable This jumper enables/disables alarm led operation during alarm Indications. The detector is factory preset to SW1-OFF (LED enabled). SWZ — Lovell/Levelz Detection This a sensitivity selection jumper which may be used to optimize false alarm immunity for certain acoustic environments. The detector is factory set for Levelt detection (SWZ = OFF). This is the highest sensitivity setting for the detector. and will be suitable for most applicatlons. For rooms which are smaller. and contain a significant amount of sound-reflective surfaces (such as bathrooms, kitchens, entrances, etc), Level2 detection (SW2=0N) pmvides a reduced sensitivity setting which is more appropriate iorthese environments. Locating the Detector The detector is omnidirectional, providing 350° coverage. Coverage is measured from the detector to the point on the glass farthest from the detector as shown in Figure xx. Guidelines for Optimizing Detect/on andAvoiding False Alarms Insert here all bullets from A04 00 sheet 29002506R1 — section "Locating detedor‘ Testing the Detector When choosing a location for each WLS-912 glass break detector, the following test should be performed to ensure that it is mounted in the best possible location. Test Mode Setup: 1, Select a location. Make sure that the Alarm Led is enabled (dip switch J1 =OFF) 2. Place the detector in test mode by momentarily pressing the tab on the base plate, as shown in Figure xx. The detector‘s led will blink periodically to indicate that it is operating in test mode. Test mode operation is tenninatsd either manually (by momentarily pressing the tab on the base plate), or automatically by the detector (alter 10 minutes). 3. Use double—sided tape to temporarily mount the detector in the selected location. NOTE: The detector will not respond to the glass break simulator unless the test mode operation has been enabled by momentarily pressing the test mode tab on the base plate. - CONFIDENTIAL: FOR INTERNAL USE ONLY- 1 0/23/95 FCC ID: FSSQGSSIZ D. Cecic — DSC Ltd. WL591 2 Wireless ACUITY Glass Break Detector Instructions for Installation and Use “WORKING PAPER “ Testing: The AFT-100 Glass Break Simulator The AFT-100 glass break simulator generates plate or tempered glass sounds. Use the plate glass setting if you are unsure of the glass type. Observe the following when testing the detector. - The correct mounting location is indicated by three successive detections. It the detector does not respond each time, relocate the detector and repeat the test. . If the windows in question are covered by drapes or blinds. place the tester behind the closed window coverings. If the drapes prevent reliable detection, we suggest that the detector be mounted behind the drapes either on an adjacent wall or on the ceiling. . If there are multiple windows, or one large window, activate the tester at the furthest point on the glass. Mounting the Detector Once the location of the detector has been detemined. pertorrn the Module Placement Test to ensure that the selected location is in range of the wireless receiver (See the Placement Test instructions in the Instruction sheet for your receiver). [NOTE: ADD FOLLOWING PARAGRAPH TO ALL 900MHZ SYSTEM INSTALLATION MANUALS — RE “MODULE PLACEMENT AND TESTING — Glass Break Detectors": “Remove the detector from its backplale, wait 5 seconds, then reattach the detedor to its backplate. The keypad will then display the test result. An alternative method is to press/hold the test mode tab, wail 5 seconds, then release the test mode tab“.] Once the transmitter range has been verified, the detector can be mounted to the wall. For mounting to a wall, mount the backplate using the screw holes Indicated in Figure m. The detector can also be mounted on the XXXX-XX ceiling/wall mount bracket using the screw holes indicated in Figure xx. Once the detector is permanently mounted, repeal the installation tests using the AFT-100 tester to confirm proper operation. - CONFIDENTIAL : FOR INTERNAL USE ONLY— 1 0/23/98
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : Yes Create Date : 2001:07:12 16:03:57 Producer : Acrobat Distiller 4.0 for Windows Modify Date : 2001:07:12 16:03:58-04:00 Page Count : 3EXIF Metadata provided by EXIF.tools