Tyco Safety Sensormatic 4000-PI26 RM2L-4000-P126, RM2-4000-P126 User Manual RM2 4000 PI26 RM2L 4000 PI26 Reader Installation Guide
Tyco Safety Products/Sensormatic RM2L-4000-P126, RM2-4000-P126 RM2 4000 PI26 RM2L 4000 PI26 Reader Installation Guide
User Manual - DRAFT4_RM2L_4000_P126_Reader_8200- 1179-01_A0.pdf
RM2-4000-PI26 Reader RM2L-4000-PI26 Reader Installation Guide Version A0 Document Part Number 8200- 1179-01 September 2015 OVERVIEW This guide provides installation and connection information for RM2-4000-PI26 and NOTE AF RM2L-4000-PI26 Readers. The RM2-4000-PI26 reader model is UL294 approved and not UL1076 approved. The RM2L-4000-PI26 reader model is both UL294 and UL1076 approved. Reader Models The RM readers provide an enclosed RM-4 board with multiple read heads. The readers include two separate read heads in their enclosure – a multi-technology read head positioned behind the right hand side of the reader, and a separate Indala prox read head located behind the keypad portion of the reader. The multi-technology read head will read both low frequency (125KHz) HID prox cards and high frequency (13.56 MHz) smart cards. RM2-4000-PI26 FIGURE 1. Reader Models RM2L-4000-PI26 Overview TABLE 1. Part Numbers RM2-4000-PI26 With keypad and LCD; built-in RM-4 DS interface board RM2L-4000-PI26 The RM Multi-Technology reader can read three major card technologies – HID prox, Indala prox, and 13.56 MHz smart card. Specific card formats supported include ISO 14443 A/B serial number, ISO 15693 serial number, iCLASS® serial number, MIFARE encrypted sector, DESFire serial number, FIPS 201 PIV-II, and most 125 KHz formats (HID, Indala 26-bit and CASI ProxLite). UL has not evaluated the ability to “flash” new card protocols or formats directly to the reader. The RM Multi-Technology reader can be used to transition from a proximity system to a more advanced smart card system gradually over time, or to maintain the existing proximity card system while moving selected personnel to smart cards. UL has not evaluated Smart Card technology with this unit. UL has evaluated the Wiegand Proximity (26-bit only) card format for this unit. TABLE 2. Proximity (125 KHz) Formats Supported Proximity (125 KHz) Formats Supported With keypad; built-in RM-4 DS interface board NOTES Part Number AF Supported Technologies and Card Formats Reader Model As Shipped: Default Mode (On) HID® 26 Bit Yes HID® Corporate 1000 Yes HID® 36 Bit Wiegand Yes HID® 37 Bit Wiegand Yes Other HID® Pass-through Formats Yes Indala 26 Bit Yes Deister Prox SmartFrame® Yes (GE) Casi Rusco ProxLite Yes Kantech ioProx No Proximity (125 KHz) Formats Supported NOTE Not all features have been evaluated by UL. Features Smart Card (13.56 MHz) Formats Supported TABLE 3. Smart Card (13.56 MHz) Formats Supported Enabled by Default? MiFARE® Sector No MiFARE® Serial number, 32 Bit Yes MiFARE® Serial number, 56 Bit Yes MiFARE® Plus Serial number, 56 Bit Yes MiFARE® DesFire Serial number, 56 Bit No MiFARE® DesFire® EV1 Serial number, 56 Bit No iCLASS® ISO 15693 Serial number, 64 Bit Yes * PIV, TWIC, CAC, FASC-N Read Yes* (200-bit output) * PIV-I, 128 Bit, GUID Yes* (if 200-bit output is enabled) AF Smart Card (13.56 MHz) Formats Supported * PIV-C, 128 Bit, GUID Yes* (if 200-bit output is enabled) * Refers to cards issued under the U.S. Government Smart Card Initiative, HSPD-12. Not all features have been evaluated by UL. NOTE Universal compatibility with most 125 KHz Prox (including all HID® Prox formats and Indala 26-bit), all ISO 15693, and ISO 14443A credentials (badges, disk tags and key fobs). Reads both 125 KHz and 13.56 MHz credentials in the same reader. FEATURES NOTE Electrical protection (reverse polarity diode protection on power lines). Data lines: high-speed transient voltage suppressor diodes. IP65-rated sealed electronics for deployment in both interior and exterior environments. Beep-on-card defaults to ON. PIV support – The reader supports a FASC-N read (low assurance read, 200-bit output) from all major PIV, TWIC and CAC cards, plus a 128-bit output from PIV-I and CIV cards. MIFARE 7-byte CSN Support - The reader firmware will be able to distinguish between a legacy MIFARE Classic card and a “next-generation” MIFARE classic card. The next generation MIFARE cards have a unique 7-byte serial number, not 4byte. When presented to a reader, the next-gen card causes the reader to output a 56bit CSN. Older cards still output a 32-bit CSN. Not all features have been evaluated by UL. Features Controller Communications Wiegand Locally Flashable via RS485 Open Standards Compliance ISO 14443A ISO 14443B ISO 15693 Configure Using Program Card Pass-through - Default setting that allows the reader to send all data on the card. Fixed length - Reader can be configured to output a fixed length by padding or truncating data on the card. CASI ProxLite (26-bit, 32-bit, 35-bit, 37-bit, 64-bit) AF 44-bit pass-through MIFARE sectors Customize encryption keys Specify data format (number of bits output) Select a sector (0-15) Enable PIN-on Smart Card functionality FIPS 201 PIV-II Customize FASC-N Weigand BCD output 75-bit 128-bit 200-bit (default) Customize the HMAC by changing the site key Output HMAC Output expiration date Specifications SPECIFICATIONS Specification Requirement Data Cable Recommended data cable is Belden #9841or equivalent. The maximum length is 4000 feet (1212 meters) between the controller and the reader. Power Wiring Recommended power wiring is Belden #8461/8442 twisted pair. Maximum length depends on the wire gauge. Readers can be powered from a local power supply. Temperature Indoor: 32° F to 120° F (0° C to 49° C) Outdoor: -31° F to 151° F (-35° C to 66° C) Reader Display: 14° F to 151° F (-10° C to 66° C) Display with heater kit: -4° F to 151° F (-20° C to 66° C) Maximum: 25 feet Distance from P5 to the ARM-1 Distance from P5 to the inputs Maximum: 2000 feet Locate as close as possible to the switch. AF 1KW resistors for the NO and NC supervised inputs Shielded, minimum 22 AWG stranded, twisted pair cable Power Requirements Must be used to comply with UL. Reader power to be supplied from power limited output of a Listed control unit or from a separately-supplied UL Listed, access control (UL294) or burglar alarm (UL603), power-limited power source with 4-hour standby capability. Connection to the ARM-1 has not been evaluated by UL. NOTES TABLE 4. Reader Power Supply Requirements Reader Power Requirements: 12 VDC RM2-4000-PI26 With Keypad 350 mA Max RM2L-4000-PI26 With Keypad and LCD 350 mA Max Relay contact power limits Up to 30 VAC/DC, 3.3 A maximum Voltage Range: 12V Voltage Range: 12V Installation INSTALLATION To Install the Reader: 1. Install the reader mount plate. 2. Wire the components. 3. Connect and ground the cable shields on the reader bus. (Refer to TAB 2010-15 “RM Reader ESD Protection Guidelines.”) 4. Set the reader address. 5. Install the ARM-1 relay boards (optional). 6. Install the heater kit (optional). 7. Mount the reader standard housing on the reader mount plate using the Software House security screwdriver (Part number 132-183). Figure 2 shows the standard housing, mount plate, and gasket. The readers conform to the same housing, mount plate, and gasket dimensions. Install the RM Mount Plate FIGURE 2. Standard Housing and Mount Plate AF Standard Housing Housing screws Requires a security screwdriver Standard mount plate Figure 3 on page 7 shows the mount plate dimensions. Gasket Installation FIGURE 3. Mount Plate Dimensions 5.45" Wiring access 4.11" 3.66" 4.94" 2.47" 1.29" .83" 1.54" 1.82" 8 mounting holes 2.73" 3.64" .0.156" Thru, 0.280” Countersink 3.92" AF This device has been approved for outdoor use when properly installed with the RM Heater Kit Installation (P.N. 130-915) and the supplied gasket material. Position the gasket with the RM mount plate so that the mounting holes are properly aligned. Ensure that the gasket is placed between the mounting surface and mating surface of the RM mount plate. Fasten the RM mount plate to the mounting surface with the gasket material in between. Install the gasket so that no gaps or wrinkles are present. The RM mount plate contains eight mounting holes. However, you do not have to use all eight holes; usually any four of the eight holes are adequate. The mounting holes are 0.156” and provide clearance for 6-32 flat head counter sunk bolts or screws. Installation Figure 4 shows reader connections. FIGURE 4. Reader Connection UL has not evaluated the ARM-1. NOTE AF Wiring the Reader Components Setting up the reader Figure 5 shows RM-4 P1 and P5 wiring. FIGURE 5. RM-4 Wiring Requirements AF Wiring the Inputs, Outputs, Reader Bus SW3-7 and SW3-8 refer to the Beeper on the RM-4. P3 BEEP refers to the Beeper on the read head, if it exists. There is no Beeper on the reader read heads. Some third-party readers that are connected to a standalone reader have beepers. NOTES SETTING UP THE To Set Up the Reader: READER 1. Set the Reader Address Switch, SW1 (a 16 position rotary switch, see Figure 5), to a number from one to eight. Each Reader along the bus must have a unique address. 2. The SW3-1, SW3-2, SW3-3, and SW3-6 Configuration Switches are factory preset for the readers, as shown in Figure 5 on page 9. 3. Note that you can override SW3-4, SW3-5, SW3-7 and SW3-8 if desired. To properly terminate an RS-485 line, only the last unit on the bus should have SW3-5 in the On (closed) position. Setting up the reader Grounding and Shielding Single RM Reader When connecting a single RM reader to the reader bus, use twisted pair, shielded minimum 24 AWG cable. Attach the shield at the controller end. (Refer to TAB 2010-15 “RM Reader ESD Protection Guidelines.”) Attach a local earth ground (18 or 22 gauge) wire to the J5 component on the RM reader. Multiple RM Bus Devices When wiring an RM reader to a bus with multiple devices, such as other RM-4s, I/8s, or R/8s: Attach the shields along the bus together (insulate each connection). Snip off the shield wire at the end of the bus, see Figure 6. Attach the shield to the ground at only one point – at the ground stud inside the controller Attach a local earth ground (18 or 22 gauge) wire to the J5 component on the RM reader. AF FIGURE 6. Reader Shield Wiring Ground stud Twist shield wires together and insulate (do not ground) Shield wire Shield wire Snip off shield wire at end of bus Knockout RS-485 connector on a reader (bus configuration) Enclosure/cabinet Setting Module Address and EOL Termination 10 To set the module address, set SW1 (16 position rotary switch) to a number from one to eight. Every reader on a bus must have a unique address. To set RS-485 EOL (End of Line) termination, set SW3-5 to the On (closed) position if the module is the last unit on the bus. If the module is not the last unit on the bus, SW3-5 should be Off (open). Setting up the reader Figure 7 shows how to connect ARM-1 relay modules to the reader outputs and how to wire NO (Normally Open) and NC (Normally Closed) supervised inputs. AF FIGURE 7. Reader Input/Output Connections Two ARM-1 relay components can be connected to the reader through the P5 connector (Table 5 ). Installing the ARM-1 Relay Module RM P5-1 is the common (+12 VDC) pin for either ARM-1. RM P5-2 is the output drive (GND) for the first relay. RM P5-3 is the output drive (GND) for the second relay. TABLE 5. ARM-1 Wiring Module (131-192) Wiring ARM-1 Relay ARM P2-1 to RM P5-1 ARM P2-2 to RM P5-2 ARM-2 Relay ARM P2-1 to RM P5-1 ARM P2-2 to RM P5-3 11 Setting up the reader Installing the Heater (optional) The readers require a heater kit (Model C130-915) when installed outdoors in an environment where temperatures may drop below 40° F (5° C). The Model C130-915 heater kit contains the following parts: TABLE 6. Heater Parts Description Transformer 12 VAC 40VA Heater Strips Thermostat (turns on at 40 ° F) Wire nuts 6-32 x 1/4” screws to mount thermostat to RM plate. Quantity AF Part number C130-915A is supplied without a transformer. A UL Listed Class 2 transformer rated output 12 VAC, 40 VA is required for proper installation. Figure 8 shows how to wire the RM heater kit. FIGURE 8. RM Heater Kit Wiring Figure 9 on page 13 shows the location of the heater strips and thermostat on the RM mount plate. 12 Setting up the reader FIGURE 9. RM Installation To Apply Heater Strips: Applying Heater Strips AF 1. Clean the attachment surface of the RM mount plate with a solvent such as alcohol (use all required precautions when handling solvents). 2. Carefully remove the release film from the adhesive. 3. Locate the heater on the clean surface of the RM mount plate exactly as shown in Figure 9. 4. Gently roll the heater strip in place to remove air bubbles. 5. For maximum adhesion, do not apply pressure to the heater strips for 72 hours. Air gaps or bubbles under the heater cause localized overheating and possible heater burnout. Also, application of adhesives at temperatures below 50° F is not recommended. NOTE Installing the Thermostat To Install the Thermostat: 1. Fasten the thermostat to the RM mount plate with the body of the device facing the junction box and the face sitting flat against the RM mount plate surface. 2. With the back (or outside) surface facing up, align the thermostat such that the screw holes of the thermostat allow for the 6-32 x 1/4” screws to secure the device to the RM mount plate. 3. Use two (Quantity 2) 6-32 x 1/4” screws to mount the thermostat to the RM mount Plate. Tighten the screws allowing the thermostat to be sufficiently secured to the RM mount plate. Do not over tighten the screws. 13 Testing Readers TESTING READERS To Test the Readers: 1. Properly configure Readers, Inputs, and Outputs using the C•CURE Administration application and put the reader Online. 2. Measure the supply voltage to the reader. The voltage can be measured between pin 1 (+12 VDC supply) and pin 4 (ground) on the P4 connector. The voltage must be +12 VDC (+/-5%). 3. Check the reader address setting. The reader must be set to an unused address, between 1 and 8, when connected to the apC or iSTAR. Use rotary switch SW1 to set the reader address. 4. Check the reader for communications to the controller by observing LED2 and LED3. (RM2L-4000-PI26 only) 5. Check the supervised inputs. Configure the inputs on the controller using the C•CURE Administration application. AF With no switches or resistors connected to the supervised input 1 and 2 lines, the C•CURE Monitoring application should report inputs as “Open Loop”. When you connect the 1,000-ohm resistor to the input terminals, the C• CURE Monitoring application should report that the input as “Deactivated”. Supervised inputs #1 is found at pins 4 and 5 of P5. Supervised input #2 is found at pins 6 and 7 of P5. 6. Check the outputs. The outputs can be functionally tested by using the “momentary activate” feature in the C• CURE Monitoring application. When the outputs are momentarily activated, the signal will change state for a few seconds. An RM2L-4000-PI26 and RM2L-NH can be used in area/partition for signal acknowledgement. 7. Check the reader interface. The reader interface can only be tested by presenting a card with the appropriate technology to the reader. Reading a card will cause the display to show “Access Granted” or “Access Denied,” depending on the clearance of the card. CONFIGURATION The change to the default reader settings requires the use of special program cards that NOTES are available from the Software House Applications Department. Program cards are used to set a specific MIFARE read key and change other settings including card technologies to be read. To Program a Card Reader: 1. Power cycle the reader. 2. Present the .INI card. The reader’s internal amber LED turns off within the read head compartment to indicate the reader is ready for the first program card. 3. Present the first program card. The amber LED turns on solid. 14 Configuration Notes 4. If there are more program cards, repeat steps 2 and 3 until you have presented the necessary number of program cards. 5. The reader is configured for the specified option(s) and is ready for use. AF For information about upgrading the firmware revision, refer to the PDF document entitled SWH Readers Download Firmware to Reader posted on the Software House Member Center. Flash Upgrade Amber LED 15 Compliance Compliance Specification Description UL294 5th Edition Access Control System USA UL1076 5th Edition Proprietary Alarm Units USA IEC60950-1 ITE – Safety International EN60950 ITE – Safety EU EN55022-:2010 ITE – Radio Disturbance Characteristics EU EN55024 ITE – Immunity Characteristics EU EN50130-4:2011 Alarm systems – Electromagnetic Compatibility EU RoHS Restriction of hazardous substances EU FCC 47 CFR part 15 FCC – unintentional transmitter USA - Class A ICES-003/NMB-003 Issue 5 Canada – unintentional transmitter Canada - Class A AF IEC 62599-2 AS/NZS CISPR 22:2009 ITE – Radio Disturbance Characteristics Australia/New Zealand Canadian Radio This digital apparatus does not exceed the Class A limits for radio noise emissions from Emissions digital apparatus set out in the Radio Interference Regulations of the Canadian Requirements Department of Communications. Le present appareil numerique n’emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la class A prescrites dans le Reglement sur le brouillage radiolelectrique edicte par le ministere des Communications du Canada. United States This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the device is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense. CAUTION: Equipment changes or modifications without the approval of the party responsible for compliance could void the user's authority to operate the equipment and could create a hazardous condition. 16 Important Safety Information UL Listing The following requirements must be adhered to: RM2L-4000-PI26 and RM2-4000-PI26 readers are Underwriters Laboratories Inc. (UL) Listed to Standard UL 294, Access Control System Units. RM2L-4000-PI26 reader is Underwriters Laboratories Inc. (UL1076). The RM2-4000-PI26 and the RM2L-4000-PI26 readers installed in accordance with the National Electric Code (ANSI/NFPA 70) or the Canadian Electric Code as required by local authorities. When purchased modularly, the reader module assembly is only for field replacement in the RM housing. Important Safety Information AF LIFE SAFETY REQUIREMENT: A fail-safe mechanism override must be installed at each card reader exit to allow people to leave the secure area in case of electromechanical device failure. 2002/96/EC (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. C•CURE and Software House are trademarks of Tyco Security Products. The trademarks, logos, and service marks displayed on this document are registered in the United States [or other countries]. Any misuse of the trademarks is strictly prohibited and Tyco will aggressively enforce its intellectual property rights to the fullest extent of the law, including pursuit of criminal prosecution wherever necessary. All trademarks not owned by Tyco are the property of their respective owners, and are used with permission or allowed under applicable laws. Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all features. Availability varies by region; contact your regional sales manager. Document Number: 8200-1179-01 Revision: A0 Release Date: September 2015 This manual is proprietary information of Software House. Unauthorized reproduction of any portion of this manual is prohibited. The material in this manual is for information purposes only. It is subject to change without notice. Software House assumes no responsibility for incorrect information this manual may contain. ©2015 Tyco Security Products All Rights Reserved. 17 T AF
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Has XFA : No Language : en XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 10.1.15 (Windows) Creator Tool : FrameMaker 10.0.2 Modify Date : 2015:09:02 08:21:50-04:00 Create Date : 2012:08:28 11:05:58Z Metadata Date : 2015:09:02 08:21:50-04:00 Format : application/pdf Title : RM2-4000-PI26/ RM2L-4000-PI26 Reader Installation Guide Creator : Software House Technical Publications Document ID : uuid:e9cd3c8a-bd9e-459b-afff-2b8777a7322f Instance ID : uuid:4d66311a-e7ee-4bd4-91e2-f9fc9ad0a23b Page Layout : SinglePage Page Mode : UseOutlines Page Count : 18 Author : Software House Technical PublicationsEXIF Metadata provided by EXIF.tools