Tyco Safety Sensormatic BIM1000 Business Intelligence Module User Manual
Tyco Safety Products/Sensormatic Business Intelligence Module
Contents
- 1. User manual
- 2. User manual_REV
User manual
PRELIMINARY Business Intelligence Module (BIM1000) Installation Guide BIM1000 © 2018 Sensormatic Electronics, LLC BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-03 REV 3E 1 of 32 *8200-1088-03* PRELIMINARY Contents About this guide ..................................................................................................................................... 4 Additional documentation .................................................................................................................... 4 Technical Support ............................................................................................................................... 4 About the product ....................................................................................................................................... 5 Features .............................................................................................................................................. 5 Compatibility ........................................................................................................................................ 5 Section I: Installation sequence overview ................................................................................................ 7 Section II: Before you begin ....................................................................................................................... 8 Installation prerequisites ....................................................................................................................... 8 Training................................................................................................................................................ 8 Part numbers .......................................................................................................................................... 8 Survey and planning requirements ...................................................................................................... 9 Survey requirements ........................................................................................................................... 9 Network Topology Map requirements ................................................................................................. 9 Application and firmware requirements ............................................................................................... 9 TrueVUE requirements ...................................................................................................................... 10 Laptop requirements ......................................................................................................................... 10 Component installation requirements ............................................................................................... 10 Electrical power requirements ........................................................................................................... 10 Wiring requirements .......................................................................................................................... 10 Tools required ................................................................................................................................... 11 Safety ..................................................................................................................................................... 11 Section III: Installing the Business Intelligence Module (BIM1000) ..................................................... 12 Overview of steps ................................................................................................................................. 12 Step 1: Locating the Business Intelligence Module ......................................................................... 12 Step 2: Mounting the Business Intelligence Module ........................................................................ 13 Mounting the Business Intelligence Module to a hollow cavity wall .................................................. 13 Mounting the Business Intelligence Module to the ceiling ................................................................ 14 Mounting the Business Intelligence Module to a surface-mounted electrical box ............................ 17 Step 3: Connecting and securing the Business Intelligence Module ............................................. 18 Section IV: Connecting the Business Intelligence Module (BIM1000) ................................................. 20 Overview of connection steps ............................................................................................................ 20 Equipment required ............................................................................................................................. 20 Step 1: Connecting the Business Intelligence Module .................................................................... 21 Ethernet cable set-up ........................................................................................................................ 21 USB set-up ........................................................................................................................................ 23 Step 2: Optional: Installing a cellular modem ................................................................................... 25 Step 3: Commissioning the Business Intelligence Module ............................................................. 26 Step 4: Powering on the Business Intelligence Module ................................................................... 28 Step 5: Verifying the Business Intelligence Module ......................................................................... 29 BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-03 REV 3E 2 of 32 *8200-1088-03* PRELIMINARY Specifications ............................................................................................................................................ 30 Declarations ............................................................................................................................................... 31 Other declarations ................................................................................................................................ 32 BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-03 REV 3E 3 of 32 *8200-1088-03* PRELIMINARY About this guide This installation guide explains how to install the Business Intelligence Module (BIM1000) with the Business Intelligence Accessory (BIX1000), to synchronize all Sensormatic-connected devices. Additional documentation The following is a list of additional documents related to this installation: Business Intelligence Accessory (BIX1000) Installation Guide, 8200-1088-15. Business Intelligence Module (BIM1000) and Business Intelligence Accessory (BIX1000) Setup Guide, 8200-1088-01. Ultra Post® IV AMS-1012 Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide, 8200-1088-05. Ultra Post® VI AMS-1014 Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide, 8200-1088-06. Ultra 1.8 Meter ABS Pedestal Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide, 8200-1088-07. AMB9010-IPS and AMB-1200 Label Deactivator Controller Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide, 8200-1088-08. AMS-9050 Controller Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide, 8200-1088-09. AMS-9040 Controller Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide, 8200-1088-10. AMS-9060 Controller and AMS-1170-2C/4C Controller Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide, 8200-1088-11. ZBSMPROE ScanMax® Pro Label Deactivator Controller Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide, 8200-1088-12. IDKM-10XX/AMK-10XX SuperTag® Detacher Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide, 8200-1088-13. AMB-2011/AMB-1101/ZBAMB9010 EAS Label Deactivator Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide, 8200-1088-16. Business Intelligence Accessory (BIX1000) Extension Cable Kit Installation Guide, 8200-1088-14. Technical Support For product bulletins, and the most recent updates to this guide, visit https://sensormaticsecurelogin.com BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-03 REV 3E 4 of 32 *8200-1088-03* PRELIMINARY About the product The Business Intelligence Module (BIM1000) is a wireless access point that connects to the Business Intelligence Accessory (BIX1000). Using IEEE 802.15.4 wireless protocol, the Business Intelligence Accessory (BIX1000) connects to the Business Intelligence Module (BIM1000) to synchronize all in-store Sensormatic-connected devices, to collect data and to provide a health status for all connected devices. For an example, see Figure 1 and Figure 2 on page 6. The data collected includes alarms, events, and people-counting statistics. It also collects alarm response times to help eliminate false deactivation and detection alarms at store exits. Customers can use a desktop browser to log into a TrueVUE reporting platform, or a Shrink Management as a Service (SMaaS) platform, to access daily data reports from all the connected devices. The customer can also use the Device Mobile App (BIZ1000), which is compatible with iOS and Android smart devices, or they can use the Business Intelligence Module (BIM1000) Manager Interface, to monitor store-wide EAS device health, counts, and events in real-time. Features The Business Intelligence Module (BIM1000) has the following features: An embedded web configurator. A wired EAS Network (RS-485). A wireless EAS Network, 802.15.4 A wireless 802.11.B/G/N (Client and Soft AP). It can support 32 devices. It has MicroSD flash storage. It has Micro USB Type B access. It has Bluetooth radio for wireless setup. Commented [ARB1]: Comment from Marc: It has mmd so same format but a chip not a card. Clarify with Marc. Compatibility The Business Intelligence Module (BIM1000) is compatible with the following devices: The Ultra Post® IV AMS-1012 Pedestal. The Ultra Post® VI AMS-1014 Pedestal. The Ultra 1.8 Meter ABS Pedestal. The AMS-9060 Controller. The AMS-9050 Controller. The AMS-9040 Controller. The AMS-1080 Controller. The AMS-1170-2C/4C Controller. The ZBAMB9010 EAS Label Deactivator Controller. The AMB9010-IPS EAS Label Deactivator Controller. The ZBSMPROE ScanMax® Pro Label Deactivator Controller. The AMB-1200C EAS Label Deactivator Controller. The AMK-1000 and the AMK-1010 SuperTag® Detacher. The IDKM-1000 and the IDKM-1010 SuperTag® Detacher. The AMB-2011 Value Pad II Countertop EAS Label Deactivator. The AMB-1101 VersaPass II Countertop EAS Label Deactivator. BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-03 REV 3E 5 of 32 *8200-1088-03* PRELIMINARY Figure 1. Overview of the Business Intelligence Module (BIM1000) solution 802.11 Wi-Fi 802.15.4 WiFi Internet Gateway Network switch Wireless Access Point (802.11 Wi-Fi) LP Manager Business Intelligence Accessory (BIX1000) Business Intelligence Module (BIM1000) Figure 2. Business Intelligence Module (BIM1000), 0304-0170-01 Speaker Micro USB port Radio antenna (802.15.4) BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE RGB visual display Locking tab Wi-Fi antenna 8200-1088-03 REV 3E 6 of 32 *8200-1088-03* PRELIMINARY Section I: Installation sequence overview Figure 3 gives an overview of the complete installation sequence you must follow when you install a BIM1000 and a BIX1000. You must install the BIM1000 before you install the BIX1000. Figure 3. BIM1000 and BIX1000 complete installation sequence Step 2: Step 1: Before you begin: Commission the Install the Planning and BIX1000 BIM1000 prerequisites Confirm all the prerequisites in Section II are complete before beginning installation Install the BIM1000. Turn on the BIM1000, and program the PAN ID and the Channel Step 5: Validate BIM1000 configuration Step 6: Validate BIM1000 remote connectivity Validate the complete BIM1000 and BIX1000 configuration Validate the remote connectivity and data transportation of the BIM1000 Commission the BIX1000 Step 3: Install the BIX1000 cable kits Install the relevant BIX1000 cable kit, and configure the EAS devices Commented [BA[G-C2]: Feedback from Marc, survey and planning should be a pre-step. Store layout, which BIX to which BIM, Network and RS-485 topology. Step 4: Install and locate the BIX1000 Install and locate the BIX1000 Important: This installation guide only describes the following steps in the complete BIM1000 and BIX1000 installation sequence: Before you begin: Planning and prerequisites Step 1: Install the BIM Step 5: Validate the BIM1000 configuration Step 6: Validate BIM1000 remote connectivity BUSINESS INTELLIGENCE ACCESSORY (BIX1000) INSTALLATION GUIDE 8200-1088-03, REV 2C 7 of 32 *8200-1088-15* PRELIMINARY Section II: Before you begin Before you install a Business Intelligence Module (BIM1000), ensure that you adhere to the criteria outlined in the following sections. Installation prerequisites To install a Business Intelligence Module (BIM1000), you must have the following criteria in place before you proceed: Do you have the Network Topology Map requirements, or IP Request Form? Do you have the location of each BIM1000 identified? You can obtain this information from the Network Typology Map. Is there power and data, for example Ethernet, Wi-Fi, or 4G gateways, where you plan on locating the BIM1000? Do you have the applicable network ports open for functionality and device management support? Have you completed the necessary training required to install the Business Intelligence Module (BIM1000)? Training WARNING: Do not attempt to install a Business Intelligence Module (BIM1000) unless you have completed the Wireless Device Manager (BIM/BIX) Training Curriculum. To install a Business Intelligence Module (BIM1000), you must complete the following technical training modules: BIM and BIX Installation Technical Training. BIM Configuration Technical Training. Optional: SMaaS Overview Sales Training. Part numbers Table 1 lists the part numbers you require to install a Business Intelligence Module (BIM1000). Table 1. Business Intelligence Module (BIM1000) part numbers Part number 0352-0766-01 1400-0033-01 1400-0205-01 2838-0015-01 2880-0070-01 2880-0094-01 0304-0170-01 0404-1247-01 3411-0027-01 0352-0473-01 0404-1244-01 3135-1525-01 0352-0897-01 6003-0313-01 Description BIM1000 Installation Kit T-bar clip T-bar clip, 1/4-20, 5/8” L, 15/16” W Flange nut, 1/4-20, 7/16 WAF Toggle bolt, 1/4-20 x 6.00 Anchor, self-drill, with screws, #8 x 1-1/4 BIM1000 module BIM1000 mounting bracket Antenna Ceiling mount, IVS BIX mounting back cover kit BIM Power Supply BIM PWR connector-cable Micro USB B to USB-B cable, 1.8m BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE Quantity Commented [ARB3]: These part numbers are not included in the BOM Marc sent me. Are these going to be included in the BOM or do they need to be ordered separately? Could you please provide the part number for the power connector cable, I cannot locate it on Windchill? 8200-1088-15, REV 3E 8 of 32 *8200-1088-15* PRELIMINARY Survey and planning requirements This section outlines the site survey and planning requirements, and the systems requirements that are critical to the correct installation of a BIM1000. Survey requirements Commented [BA[G-C4]: Question for Marc Blanchenay: You must access the following criteria before you proceed with the installation of a BIM1000: Does the installer need to do this or will it be included in the Network Typology Map? The layout and design of the installation site. The location of each BIM1000 module. You can obtain this information from the Network Typology Map. Identify each BIX1000 you need to program to each BIM1000 module. Network Topology Map requirements You require the following information for each device you place on the network when you install a Business Intelligence Module (BIM1000) to work with a Business Intelligence Accessory (BIX1000). This information is in the Network Topology Map that the project manager or the coordinator for the account supplies, or in the IP Request form document that the customer’s IT department supplies. The location of each BIM1000 module. The switch location, name and port number. Any Wi-Fi restrictions, if setting up the BIM1000 to operate in Access Point (AP) mode. The Wi-Fi channel. Note: The Wi-Fi channel is dependent on the region of installation. The Wi-Fi access point location and the Service Set Identifier (SSID). A static or a dynamic IP address. The Subnet Mask. The Gateway The NTP Server. The Ethernet MAC address. The Wi-Fi Subnet Mask. The Wi-Fi Default Gateway. The SIP Server address. Application and firmware requirements In order to support the installation of a Business Intelligence Module (BIM1000), you must download the latest firmware bundle, 1.00 or later, and the BIM Web Launch Tool from https://sensormaticsecurelogin.com/. To download the BIM Web Launch Tool, complete the following steps: 1. Open a web browser and launch https://sensormaticsecurelogin.com/. 2. Enter your valid logon information and click Login. 3. From the Tech Support menu, click EAS. 4. Click Software Download. 5. Click BIM Web Launch Tool Vx.xx 6. To download the software bundle, click the link, and save the file to a local folder on your laptop. 7. Log out of www.sensormaticsecurelogin.com/. 8. On your laptop, rename the file you saved to an .exe file. Click the executable file, and click Run. BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 9 of 32 *8200-1088-15* PRELIMINARY 9. Follow the setup wizard instructions to save the software on your laptop. Note: Files save to the following location: C:\Program Files\Sensormatic\BIM Software Bundle x.x. (Program Files (x86) for 64 bit machines). TrueVUE requirements To support TrueVUE reports for a Business Intelligence Module (BIM1000) installation, you require the following: TrueVUE ,version 7.5 or later. Commented [ARB5]: Included as per conversion with John Clark. 7.5 is scheduled for release in April. The SIP URL as stated in the Network Topology Map. If authentication is necessary, you need your valid service credentials. The store name, the store number, and the division number. The heartbeat interval. Ensure the appropriate port is open, typically port 8080 or 8081. Commented [ARB6]: Removed the wireless adapter and the Bluetooth adapter from this list. Wi-Fi and Bluetooth are disabled by default so moving these sections to the Setup Guide. Laptop requirements You require the following items for your laptop: Internet Explorer version 11, or Mozilla Firefox version 56, or Google Chrome version 64, browser installed. Note: Ensure JavaScript are blockers on the web browser. A USB port. An Ethernet adapter. Component installation requirements This section outlines components installation requirements to install a Business Intelligence Module (BIM1000). Electrical power requirements Confirm the following electrical power requirements are in place to install a Business Intelligence Module (BIM1000): The AC power cord could be carrying 120Vac or 240Vac. The AC source must be a 2-wire type with ground. It also must be a 24-hour, unswitched outlet with less than 0.5Vac between neutral and ground. Note: The BIM1000 takes its Sync signal from this AC power source. The BIM1000 can operate from generator supplied AC power if it meets the AC power requirements. Important: You must select Generator Mode when configuring the BIM1000 for use in multiple generator environments. Wiring requirements Confirm the following wiring requirements are in place for each piece of hardware before you install a Business Intelligence Module (BIM1000): RS-485 cabling, including the termination of cabling, the pinouts, and a diagram with RS485-High, RS485-Low, and Sync connections outlined. All Ethernet patch cables must be CAT5e, CAT6, or CAT6e. BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 10 of 32 *8200-1088-15* PRELIMINARY Tools required Confirm that you have the following tools before you install a Business Intelligence Module (BIM1000): A #2 Philips head screwdriver. A cable tester. A Digital Volt Meter. A micro USB cable, 6003-0313-01, or an Ethernet patch cable. A drill, and assorted drill-bits. A drywall saw. Safety You must adhere to the following safety instructions when you install a Business Intelligence Module (BIM1000): WARNING: Risk of electric shock Disconnect all power sources before servicing. Do not install the Business Intelligence Module (BIM1000) in a plenum or other environmental air-handling space. You must use plenum-rated cables, unless the cables are in raceways. Installation of the BIM1000 must comply with the latest national electrical codes, national fire code, and all applicable local codes and ordinances. National or local wiring codes may differ between regions. Adherence to these codes supersedes instructions in this document. You must observe and respect all the safety instructions in this installation guide, and or the operation of the Business Intelligence Module (BIM1000). You must mount the Business Intelligence Module (BIM1000) only as instructed in this installation guide. Mounting the Business Intelligence Module (BIM1000) any other way can affect its operation. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications can void the user’s authority to operate the equipment. You must install the antennas for this transmitter with a separation distance of at least 20 centimetres (8 inches) from all persons, and must not be collocated or operating in conjunction with any other antenna or transmitter. BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 11 of 32 *8200-1088-15* Commented [ARB7]: Reply from Bill Owsley: We have not yet received the FCC certificate and expect it by months end. Because the application has the 2 antennas in it, I would guess the certificate might not have that statement. TBD. PRELIMINARY Section III: Installing the Business Intelligence Module (BIM1000) This section outlines how to install a Business Intelligence Module (BIM1000). Important: You must install the Business Intelligence Module (BIM1000) before you install the Business Intelligence Transceiver (BIX1000). Note: You can power on and set-up the Business Intelligence Module (BIM1000) before you install it. To do this, proceed to Step 4: Powering on the Business Intelligence Module on page 28. Overview of steps This section gives an overview of the steps involved in installing a Business Intelligence Module (BIM1000): Step 1: Locating the Business Intelligence Module (BIM1000). Step 2: Mounting the Business Intelligence Module (BIM1000). Step 3: Connecting and securing the Business Intelligence Module (BIM1000). Step 1: Locating the Business Intelligence Module To locate the Business Intelligence Module (BIM1000) correctly, you must adhere to the following guidelines when you locate the Business Intelligence Module (BIM1000). Locate the BIM1000 a minimum of 2 feet or 24 inches from the Business Intelligence Transceiver (BIX1000). For more information, refer to the Business Intelligence Accessory (BIX1000) Installation Guide, 8200-1088-15. Commented [BA[G-C8]: For the moment starting with this value. Manny will get back to me once tests are performed over the coming weeks. (05/02/18) Table 2 lists the expected maximum line of sight range from BIM1000 to BIM1000 modules, and from BIM1000 to BIX1000 modules. The maximum line of sight ranges are based on environments free of obstructions and interference, the range can significantly degrade from the specified maximums. Table 2. Expected maximum line of sight ranges between modules Modules Region Expected maximum line of sight range BIM1000 to BIX1000 BIM1000 to BIX1000 BIM1000 to BIX1000EA BIM1000 to BIM1000 BIM1000 to BIM1000 EU US EU EU US 76.2 meters (250 feet) 106.7 meters (350 feet) 106.7 meters (350 feet) 182.9 meters (600 feet) 370 meters (1,217 feet) You must install the antennas for this transmitter with a separation distance of at least 20 centimetres (8 inches) from all persons, and must not be collocated or operating in conjunction with any other antenna or transmitter. BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 12 of 32 *8200-1088-15* Commented [ARB9]: TBD. PRELIMINARY Step 2: Mounting the Business Intelligence Module You can mount the Business Intelligence Module (BIM1000) in one of the following ways: To a hollow cavity wall. To a ceiling. To a surface-mounted electrical box. Mounting the Business Intelligence Module to a hollow cavity wall To mount the Business Intelligence Module (BIM1000) to wall with a hollow cavity, you require the following equipment: A Ceiling Mount IVS Kit, 0352-0473-01. A BIM Mounting Plate, 0404-1247-01, supplied with the Business Intelligence Module (BIM1000). A #2 Phillips screwdriver. A 2-inch (5 centimeters) bell saw, or hole saw. A drill, with assorted drill bits. A drywall saw. To mount a Business Intelligence Module (BIM1000) to a hollow cavity wall, complete the following steps: 1. Locate the BIM Mounting Bracket, 0404-1247-01, and orientate it with the arrows pointing up to the ceiling, as shown in Figure 4. Important: You must locate the Business Intelligence Module (BIM1000) a minimum of 2 feet (24 inches) from the Business Intelligence Accessory (BIX1000). 2. Use the BIM Mounting Bracket, 0404-1247-01, as a template and with a pencil, mark the mounting holes, and the Power, the Ethernet, and the RS485 cable entry holes. See Figure 4. Figure 4. Front view of the BIM Mounting Bracket, 0404-1247-01 Mounting holes Power cable opening RS485 cable opening BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE Arrow up indicators Ethernet cable opening 8200-1088-15, REV 3E 13 of 32 *8200-1088-15* PRELIMINARY 3. Use a hand drill and a 2-inch (5 centimeters) drill-bit to drill the mounting holes on the wall. 4. Use a bell saw, or a hand saw, to cut out the Power, the Ethernet, and the RS485 cable holes. 5. From the Ceiling Mount IVS Kit, 0352-0473-01, locate two drywall anchors, 2880-0094-01, and insert into the mounting holes in the wall. Commented [WM[G-C10]: Is this the correct drill-bit size for the mounting holes? Commented [WM[G-C11]: Are these the correct anchors from the kit? There’s two types. 6. To prepare the cabling, complete the following steps: a. Locate the RS-485 cable and feed it through the RS485 cable opening on the BIM Mounting Bracket, 0404-1247-01. b. Secure the RS485 cable into the strain relief notch. See Figure 5. Figure 5. BIM Mounting Bracket cable strain relief feature c. Feed the Ethernet cable through the Ethernet cable opening on the BIM Mounting Bracket, 0404-1247-01. d. Secure the Ethernet cable into the strain relief notch. See Figure 5. e. Locate the three-pin connector cable from the XXXXX Kit and feed it through the Power cable opening on the BIM Mounting Bracket, 0404-1247-01. Commented [WM[G-C12]: Where does the installer get the three-pin connector cable? 7. Secure the three-pin connector from the power cable into the strain relief notch. See Figure 5. 8. Correctly orientate the BIM Mounting Bracket in place, with the up arrows pointing to the ceiling. 9. From the Ceiling Mount IVS Kit, 0352-0473-01, locate two drywall anchor screws, 2880-0094-01, and use a #2 Phillips screwdriver to secure the BIM Mounting Bracket, 0404-1247-01, to the wall. Mounting the Business Intelligence Module to the ceiling To mount the Business Intelligence Module (BIM1000) to the ceiling, you require the following equipment: A BIM1000 Install Kit, 0352-0766-01. A BIM1000 Mounting Bracket, 0404-1247-01, supplied with the Business Intelligence Module (BIM1000). A drill with assorted drill bits. Plywood or a strut channel. You can mount the Business Intelligence Module (BIM1000) to a hard ceiling, a T-bar of a ceiling grid support, or a suspended ceiling panel using the BIM Mounting Bracket, 0404-1247-01. BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 14 of 32 *8200-1088-15* Commented [WM[G-C13]: Are these the correct anchors from the kit? There’s two types. PRELIMINARY Mounting the BIM1000 Mounting Bracket to a hard ceiling To mount the Business Intelligence Module (BIM1000) to a hard ceiling complete the following steps: 1. Locate the BIM1000 Mounting Bracket, 0404-1247-01 and the BIM1000 Installation Kit, 0352-0766-01. 2. If possible, mount the BIM Mounting Bracket into a known structural member using appropriate hardware. Alternately, use the supplied toggle bolt, 2880-0070-01, to anchor the BIM1000 Mounting Bracket. 3. Use the BIM Mounting Bracket, 0404-1247-01, as a template and with a pencil, mark the mounting holes, and the Power cable entry hole. Commented [BA[G-C14]: Should this step sit here or do I need to move it? Or is this a note? a. If required, mark the entry locations for the RS485 or the Ethernet patch cables. 4. Use a drill with a 1/2 inch (12.5 millimeter) drill-bit, and drill the mounting hole in the ceiling. 5. Use a drill with a 1/2 inch (12.5 millimeter) drill-bit, and drill a hole for the power cable. If required, also drill a hole or holes for the RS485 or the Ethernet Patch cables. 6. From the BIM1000 Installation Kit, 0352-0766-01, locate the 6-inch toggle bolt, 2880-0070-01. 7. Adjust the toggle bolt to ensure it can expand once you place it through the ceiling, and ensure a minimum of a 1/2 inch (12.5 millimeters) of the toggle bolt remains exposed below the ceiling. 8. Thread the BIM1000 Mounting Bracket, 0404-1247-01, onto the toggle bolt, 2880-0070-01, and insert it through the ceiling. 9. Pulling down slightly on the bracket assembly, spin the BIM1000 Mounting Bracket to tighten it. Note: If you have access to the area above the ceiling, you can tighten the toggle bolt, 2880-0070-01, from this location. 10. Place an additional screw on the BIM1000 Mounting Bracket, 0404-1247-01, to prevent the bracket from spinning or loosening when mounted. Alternately, place the flange nut, 2838-0015-01, from the BIM1000 Installation Kit, 0352-0766-01, above the toggle bolt to secure the bracket in place. 11. Complete the following steps to route the cables through the BIM1000 Mounting Bracket, 0404-1247-01: a. If required, locate the RS-485 cable, feed it through the RS485 cable opening on the BIM Mounting Bracket, 0404-1247-01, and then secure the RS485 cable in the provided strain relief notch. For the location of the strain relief notch on the BIM1000, see Figure 5. b. Locate the Ethernet cable and feed it through the Ethernet cable opening on the BIM Mounting Bracket, 0404-1247-01, and then secure the Ethernet cable in the provided strain relief notch. c. Locate the power cable, feed the three-pin connector end of the cable through the Power cable opening on the BIM Mounting Bracket, 0404-1247-01, and then secure the cable in the provided strain relief notch. Mounting the BIM1000 Mounting Bracket to a T-bar of a suspended ceiling support To attach the BIM Mounting Bracket, 0404-1247-01, to a T-bar of a suspended ceiling support, complete the following steps: Commented [BA[G-C15]: What size drill bit? 1. Use a hand drill with a xx drill-bit, and drill a hole in the center of the plywood. 2. From the BIM1000 Installation Kit, 0352-0766-01, locate the 6-inch toggle bolt, 2880-0070-01. 3. Insert the toggle bolt, 2880-0070-01, through the plywood, and tighten the two flanged nuts, 2838-0015-01, to secure it to the BIM Mounting Bracket, 0404-1247-01. 4. Sit the plywood across the grid support in the ceiling. 5. From the BIM1000 Installation Kit, 0352-0766-01, locate the two T-bar clips, 1400-0033-01, and clip onto the ceiling grid support to secure in place. 6. Complete the following steps to route the cables through the BIM1000 Mounting Bracket, 0404-1247-01: BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 15 of 32 *8200-1088-15* PRELIMINARY a. If required, locate the RS-485 cable, feed it through the RS485 cable opening on the BIM Mounting Bracket, 0404-1247-01, and then secure the RS485 cable in the provided strain relief notch. For the location of the strain relief notch on the BIM1000, see Figure 5. b. Locate the Ethernet cable and feed it through the Ethernet cable opening on the BIM Mounting Bracket, 0404-1247-01, and then secure the Ethernet cable in the provided strain relief notch. c. Locate the power cable, feed the three-pin connector end of the cable through the Power cable opening on the BIM Mounting Bracket, 0404-1247-01, and then secure the cable in the provided strain relief notch. Mounting the BIM1000 Mounting Bracket to a suspended ceiling panel To attach the BIM Mounting Bracket, 0404-1247-01, to a suspended ceiling panel, complete the following steps: Commented [BA[G-C16]: What size drill bit? 1. Use a hand drill with a xx drill-bit, and drill a hole in the center of the plywood. 2. From the BIM1000 Installation Kit, 0352-0766-01, locate the 6-inch toggle bolt, 2880-0070-01. 3. Insert the toggle bolt, 2880-0070-01, through the plywood, and tighten the two flanged nuts, 2838-0015-01, to secure it to the BIM Mounting Bracket, 0404-1247-01. 4. Sit the plywood across the grid support in the ceiling. 5. From the BIM1000 Installation Kit, 0352-0766-01, locate the two T-bar clips, 1400-0033-01, and clip onto the ceiling grid support to secure in place. 6. Complete the following steps to route the cables through the BIM1000 Mounting Bracket, 0404-1247-01: a. If required, locate the RS-485 cable, feed it through the RS485 cable opening on the BIM Mounting Bracket, 0404-1247-01, and then secure the RS485 cable in the provided strain relief notch. For the location of the strain relief notch on the BIM1000, see Figure 5. b. Locate the Ethernet cable and feed it through the Ethernet cable opening on the BIM Mounting Bracket, 0404-1247-01, and then secure the Ethernet cable in the provided strain relief notch. c. Locate the power cable, feed the three-pin connector end of the cable through the Power cable opening on the BIM Mounting Bracket, 0404-1247-01, and then secure the cable in the provided strain relief notch. BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 16 of 32 *8200-1088-15* PRELIMINARY Mounting the Business Intelligence Module to a surface-mounted electrical box To mount the Business Intelligence Module (BIM1000) using a surface-mounted electrical box, you require the following equipment: A BIM1000 Installation Kit, 0352-0766-01. A BIM Mounting Plate, 0404-1247-01, supplied with the Business Intelligence Module (BIM1000). Electrical boxes: For North America, a contractor can supply quad-type electrical boxes or you can source them locally. For all other geographies, refer to the mounting pattern in Figure 6 to determine the supported locally available electrical boxes. Figure 6. Mounting hole dimensions on BIM1000 mounting bracket, back view 8.5 cm 8.4 cm 8.5 cm 4.6 cm 8.3 cm 6 cm To mount the Business Intelligence Module (BIM1000) using an electrical box, complete the following steps: 1. Locate the Mounting Bracket, 0404-1247-01, and orientate it with the arrows pointing up to the ceiling. See Figure 4. 2. If the electrical box is not mounted, mount the electrical box using appropriate hardware. 3. Remove one or more knockouts on the electrical box. 4. Add strain relief to the knockouts where necessary to prevent the cables from chafing, and then secure the cable entry at the electrical box. 5. Complete the following steps to route the cables through the BIM1000 Mounting Bracket, 0404-1247-01: a. If required, locate the RS-485 cable, feed it through the RS485 cable opening on the BIM Mounting Bracket, 0404-1247-01, and then secure the RS485 cable in the provided strain relief notch. For the location of the strain relief notch on the BIM1000, see Figure 5. b. Locate the Ethernet cable and feed it through the Ethernet cable opening on the BIM Mounting Bracket, 0404-1247-01, and then secure the Ethernet cable in the provided strain relief notch. c. Locate the power cable, feed the three-pin connector end of the cable through the Power cable opening on the BIM Mounting Bracket, 0404-1247-01, and then secure the cable in the provided strain relief notch. Note: Installing the Business Intelligence Module (BIM1000) to a 4x4 electrical box provides additional depth for cable connectors. 6. Orientate the Mounting Bracket, 0404-1247-01, with the arrows pointing up, over the electrical box. 5. Use two screws supplied with the electrical box, or two screws compatible with the electrical box, and secure the BIM Mounting Bracket, 0404-1247-01, to the electrical box. BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 17 of 32 *8200-1088-15* PRELIMINARY Step 3: Connecting and securing the Business Intelligence Module To secure the Business Intelligence Module (BIM1000) to the Mounting Bracket, 0404-1247-01, complete the following steps: 1. Locate the Business Intelligence Module (BIM1000). 2. Insert the three-pin connector from the power cable to the Power port on the back of the Business Intelligence Module (BIM1000). See Figure 7. Figure 7. Back view of the BIM Mounting Bracket, 0404-1247-01 Reset button Ethernet port Locking tab Power port RS485 port Tamper switch 3. Insert the Ethernet cable to the Ethernet port on the back of the Business Intelligence Module (BIM1000). See Figure 7. 4. Insert the RS485 cable to the RS485 port on the back of the Business Intelligence Module (BIM1000). See Figure 7. 5. Align the Business Intelligence Module (BIM1000) to the BIM Mounting Bracket, 0404-1247-01. See Figure 8 on page 19. 6. Insert the Business Intelligence Module (BIM1000) to the BIM Mounting Bracket, 0404-1247-01, and rotate counter-clockwise to engage the locking tab. BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 18 of 32 *8200-1088-15* PRELIMINARY Figure 8. Securing the Business Intelligence Module (BIM1000) to the BIM Mounting Bracket, Removing the Business Intelligence Module from the mounting bracket To remove the Business Intelligence Module (BIM1000) from the Mounting Bracket, 0404-1247-01, complete the following steps: 1. Use a small, flat screw driver to push lightly on the tamper switch on the left-hand side of the Business Intelligence Module (BIM) to disengage the locking tab. 2. Rotate the Business Intelligence Module (BIM) counter-clockwise to release it from the Mounting Bracket, 0404-1247-01. BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 19 of 32 *8200-1088-15* PRELIMINARY Section IV: Connecting the Business Intelligence Module (BIM1000) This section outlines how to connect the Business Intelligence Module (BIM1000). Commented [WM[G-C17]: Bill to check hardware Overview of connection steps This section gives an overview of the steps involved in connecting a Business Intelligence Module (BIM1000). Step 1: Connecting the Business Intelligence Module. Step 2: Installing a cellular modem. Step 3: Configuring the Business Intelligence Module. Step 4: Powering on the Business Intelligence Module. Step 5: Verifying the Business Intelligence Module. Equipment required To connect the Business Intelligence Module (BIM1000), you require the following equipment: ? ? BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 20 of 32 *8200-1088-15* PRELIMINARY Step 1: Connecting the Business Intelligence Module You can connect and power the Business Intelligence Module (BIM1000) in the following ways: An Ethernet cable set-up A USB set-up A Wi-Fi set-up A Bluetooth set-up Note: Wi-Fi and Bluetooth are disabled by default. To connect to the BIM1000 module using Wi-Fi or Bluetooth set-up, refer to the Business Intelligence Module (BIM1000) and Business Intelligence Accessory (BIX1000) Setup Guide, 8200-1088-01. Ethernet cable set-up To connect a Business Intelligence Module (BIM1000) using an Ethernet cable set-up, complete the following procedure: 1. Connect the Ethernet cable to your laptop and to the Business Intelligence Module (BIM1000). 2. You can connect to the Business Intelligence Module (BIM1000) in one of the following ways: Use the BIM Web Launch Tool to connect to the Business Intelligence Module (BIM1000) using the BIM Web Launch Tool, by completing the following steps: a. On your laptop, open the BIM Web Launch Tool. b. From the Network Adapter list, select the relevant Ethernet connection type. c. In the IP Address field, enter 192.168.0.100 d. Click Launch. Note: This launches a web browser to connect to the Business Intelligence Module (BIM1000). Figure 9. BIM1000 Web Interface Launcher Use the laptop network settings to connect to the Business Intelligence Module (BIM1000) using the laptop’s network settings, by completing the following steps: a. Complete the following steps to navigate to the laptop’s network settings: i. Click Start. ii. Click Control Panel. iii. Click Network and Internet. iv. Click Network and Sharing Center. BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 21 of 32 *8200-1088-15* PRELIMINARY v. Ensure that the laptop’s network matches the following network settings for the BIM1000: BIM default IP address: 192.168.0.100 BIM default Gateway: 192.168.0.254 BIM default Subnet mask: 255.255.255.0 b. Complete the following steps to verify that the laptop’s IP address is on the same subnet as the Business Intelligence Module (BIM1000): c. i. Click the Network icon on your desktop toolbar. ii. Click Local Area Connection. iii. Click Properties. iv. Click Internet Protocol Version 4 (TCp/IPv4). v. Click Properties. vi. Click Use the following IP address. vii. In the IP address field, enter 192.168.0.100 viii. In the Subnet mask field, enter 255.255.255.0 and click OK. On the laptop, launch an internet browser. d. In the internet address bar, enter the following IP address of the Business Intelligence Module (BIM1000), 192.168.0.100 Note: When it connects, the Wireless Device Configuration webpage displays. 4. To logon to the Business Intelligence Module (BIM1000) for the first time, you require a password. To obtain a password, complete the following steps: a. In the User Login pane, click Generate to generate a challenge string. Note: The generated string is valid for one week only. Do not click the Generate Challenge String button more than once, if you click the button more than once, you need to obtain another string. b. Copy the string that is generated in the Generate Challenge String field. 5. Launch an internet browser and navigate to https://sensormaticsecurelogin.com/. 6. Enter your valid logon details, and click Login. 7. Read the Terms & Conditions, and if you agree, select the check box and click Agree. 8. From the Tech Support menu, click Configurator Registration, and complete the following steps: a. From the Product Code list, click AMS-9060 Web Configuration UI. b. In the Register Number field, enter the generated challenge string you copied in step 4b. c. Click Submit. Note: A challenge string and service password is sent to the email you registered. BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 22 of 32 *8200-1088-15* PRELIMINARY USB set-up To connect a Business Intelligence Module (BIM1000) using a micro USB cable, 6003-0313-01, complete the following steps: 1. Connect the micro USB cable, 6003-0313-01, to your laptop and to the Business Intelligence Module (BIM1000). For the location of the micro USB port on the BIM1000, see item C, in Figure 2. 2. You can connect to the Business Intelligence Module (BIM1000) in one of the following ways: Use the BIM Web Launch Tool to connect to the Business Intelligence Module (BIM1000) using the BIM Web Launch Tool, by completing the following steps: a. On your laptop, open the BIM Web Launch Tool. b. From the Network Adapter list, select the relevant Ethernet connection type. c. In the IP Address field, enter 192.168.2.100 d. Click Launch. Note: This launches a web browser to connect to the Business Intelligence Module (BIM1000). Use the laptop network settings to connect to the Business Intelligence Module (BIM1000) using the laptop’s network settings, by completing the following steps: a. Complete the following steps to navigate to the laptop’s network settings: i. Click Start. ii. Click Control Panel. iii. Click Network and Internet. iv. Click Network and Sharing Center. v. Ensure that the laptop’s network matches the following network settings for the BIM1000: b. BIM default IP address: 192.168.2.10 BIM default Gateway: 192.168.0.254 BIM default Subnet mask: 255.255.255.0 Complete the following steps to verify that the laptop’s IP address is on the same subnet as the Business Intelligence Module (BIM1000): i. Click the Network icon on your desktop toolbar. ii. Click Local Area Connection. iii. Click Properties. iv. Click Internet Protocol Version 4 (TCp/IPv4). v. Click Properties. vi. Click Use the following IP address. vii. In the IP address field, enter 192.168.2.100 viii. In the Subnet mask field, enter 255.255.255.0 and click OK. c. On the laptop, launch an internet browser. d. In the internet address bar, enter the following IP address of the Business Intelligence Module (BIM1000), 192.168.2.100 Note: When it connects, the Wireless Device Configuration webpage displays. BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 23 of 32 *8200-1088-15* PRELIMINARY 4. To logon to the Business Intelligence Module (BIM1000) for the first time, you require a password. To obtain a password, complete the following steps: a. In the User Login pane, click Generate to generate a challenge string. Note: The generated string is valid for one week only. Do not click the Generate Challenge String button more than once, if you click the button twice, you need to obtain another string. b. Copy the string that is generated in the Generate Challenge String field. 5. Launch an internet browser and navigate to https://sensormaticsecurelogin.com/. 6. Enter your valid logon details, and click Login. 7. Read the Terms & Conditions, and if you agree, select the check box and click Agree. 8. From the Tech Support menu, click Configurator Registration, and complete the following steps: a. From the Product Code list, click AMS-9060 Web Configuration UI. b. In the Register Number field, enter the generated challenge string you copied in step 4b. c. Click Submit. Note: A challenge string and service password is sent to the email you registered. BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 24 of 32 *8200-1088-15* PRELIMINARY Commented [WM[G-C18]: Check with Marc Blanchenay Step 2: Optional: Installing a cellular modem This step is optional if you chose to install a cellular modem. To install a cellular modem, follow the instructions that come with the cellular modem. BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 25 of 32 *8200-1088-15* PRELIMINARY Step 3: Commissioning the Business Intelligence Module This section outlines how to commission a Business Intelligence Module (BIM1000): To commission the BIM1000, complete the following steps: 1. Return to the Business Intelligence Module webpage, and use the challenge string to generate the service password, if necessary. See Step 1: Connecting the Business Intelligence Module. 2. From the BIM Configuration menu, click BIM Status. Ensure that the versions and information in the following fields are correct, and click Save. a. Software Version – 00.07.1, or higher b. Bootloader Version – 00.00.5, or higher c. IP Address – 192.168.0.100 3. If you need to update the firmware on the BIM1000, complete the following steps: a. From the BIM Configuration menu, click Firmware Update. b. Click Browse, and select the BIM_BIX_RADIO_CFG_WEB_X_XX tar file. Note: X_XX in the tar file indicates the latest version of the firmware. c. Click Download. d. Wait for a Transfer Completed Successfully dialog box to open, and then click OK. e. Click Update. f. If the update does not complete successfully, repeat steps a, b, c, d, and e. Note: If you the BIM1000 does not update successfully, you may be instructed to perform a factory reset. For further information, contact Technical Support. If you need to perform a factory reset, complete the following steps: i. From the BIM Configuration menu, click Radio Settings. ii. Record the values for the Pan ID, Channel, and Power, and then click Save. iii. From the BIM Configuration menu, click BIM Status. iv. Click Factory Reset. v. Verify that the following firmware version updated successfully: Software Version: 00.07.1 Bootloader version: 00.00.5 Radio version: 00.32.7 Wi-Fi version: 2.9.0.0 vi. From the BIM Configuration menu, click Radio Settings, and restore the radio settings. 4. From the BIM Configuration menu, click Network Settings, and enter static IP information, or check the DHCP option to get an assigned IP address. 5. Optional: If required, select the Enable HTTP SSL check box to enable SSL on the web server. 6. From the BIM Configuration menu, click Radio Settings and complete the following steps: a. In the PAN ID field, enter a value in hex from 0 x 0001 through to 0 x FFFE. Note: The Personal Area Network (PAN) ID must be unique for each BIM1000. b. In the Channel field, enter the Channel. BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 26 of 32 *8200-1088-15* PRELIMINARY Note: The Channel must be unique for each BIM1000. You can set a value from 1 to 26 for IEEE 802.15.4 radio frequencies. c. Optional: Click Generate to generate a PAN ID and Channel. d. In the Tx Power field, enter the Tx power value for the country of use, as shown in Table 3. Table 3. BIM1000 and BIX1000 TX power Device BIM1000 BIX1000 BIX1000EA e. TX power, North America 197 (20dB) 197 (20dB) 220 (20db) TX power, Europe 57 (10dB) 78 (10dB) 89 (10db) Click Save. INSTALLATION GUIDE 8200-1088-15, REV 3E 27 of 32 Commented [ARB20]: Needs to be ironed out, and John A to include a country dropdown menu. To be decided. Commented [ARB21]: Bill Rider to confirm Note: Write down the PAN ID and Channel details to use later on when you configure the BIX1000. BUSINESS INTELLIGENCE MODULE (BIM1000) Commented [BA[G-C19]: Marc mentioned that this differs from Wi-Fi, do I need to note this here and do they need to use a different value. *8200-1088-15* PRELIMINARY Commented [WM[G-C22]: Bill Rider to provide Step 4: Powering on the Business Intelligence Module To power on the Business Intelligence Module (BIM1000), complete the following procedure: 1. Plug it in 2. When LEDs blinking 3. 4. Power Cable Route The power cable route goes from: The AC outlet inside the main electrical box in which the power supply module (1) and female-to-female coupler (2) reside. Down through existing conduit into the UltraLink enclosure below. ® Up through existing conduit and alarm module electrical box (3). To a 4x4 electrical box (4) mounted 3.7m (12ft) from the floor (the Sync AP mounts here using two screws as shown below). A length of conduit (5) will need to be added for power to reach this box. Notes: The 4.6m (15ft) Cat5 cable supplied is used to get power to the Sync AP. DO NOT connect this cable to the Sync AP or the female-to-female coupler inside the main electrical box at this time. These connections will be done at the end of the setup process. If the cable does not fit through the conduit, then cut off one of its connectors close to the end of the cable, route the cable, then reattach the connector (see page 5 for reattachment instructions). BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 28 of 32 *8200-1088-15* PRELIMINARY Step 5: Verifying the Business Intelligence Module To verify that the Business Intelligence Module (BIM1000) is functioning correctly, complete the following procedure: 1. Launch an internet browser. 2. In the address bar, enter 192.168.1.100 and press enter. The Business Intelligence Module (BIM) Web Interface opens. 3. From the User dropdown list, click Service. 4. In the Password field, enter the password. Commented [WM[G-C23]: Is this the password that the customer set earlier? 5. In the BIM Status pane, verify the following: a. Verify the Number of Devices. b. Verify the Number of Devices Online. Note: If the Business Intelligence Module is functioning correctly, the Number of Devices and the Number of Device online match. c. In the SIP Server Status pane, verify the last connection time and success percentage. BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 29 of 32 *8200-1088-15* PRELIMINARY Specifications Electrical Power supply Primary input ......................................................................................................................................................................... ............................................................... 18VDC input, Sync and RS485 through RJ45 8 pin header with LEDs for RS485. Environmental Ambient temperature ....................................................... ........................................................ 0°C to 50°C (14°F to 122°F) Relative humidity ............................................................. ............................................................ 0 to 90% non-condensing Enclosure Rating ............................................................. ..................................................................................... UL94 V-O Evaluated for altitudes less than 2,000 meters (6,561.68 feet) Mechanical Material: ........................................................................... ..............................................................................................ABS Color: .............................................................................. ..................................................................................... Light grey Dimensions: .................................................................... ........................................ 139.52 mm X 114.76 mm X 62.10 mm Weight (approx.): ............................................................ ............................................................................ 419 g (0.92 lbs) Dimensions Figure 10. Business Intelligence Module (BIM) dimensions, front view 138.82 mm (5.5 in) 81.50 mm (3.2 in) 114.76 mm (4.5 in) 139.52 mm (5.5) in 94.50 mm (3.7 in) 62.10 mm (2.4 in) BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 30 of 32 *8200-1088-15* PRELIMINARY Declarations Model: BIM1000 Regulatory information Contains the following radios; FCC ID: A8TBM78ABCDEFGH, Z64-CC3100MODR1 IC ID: 12246A-BM78SPPS5M2, 451I-CC3100MODR1 Radio Frequency of operation Type.......................................................... ............................................................................................................. BIM1000 Frequency band............................. .................................................................................................... . 2402.0 - 2480.0 MHz .............................................................................................................................................................2412.0 – 2462.0 MHz Maximum power ................................... ..................................................................................................... 10 mW in the EU ........................................................................................................................................................................ 100 mW in NA If frequency is selectable for your model, select only the country in which you are using the device. Any other selection will make the operation of this device illegal. Approved antennas Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante. This radio transmitter IC: 3506A-BIM1000 has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Le présent émetteur radio IC: 3506A-BIM1000 a été approuvé par Industrie Canada pour fonctionner avec les types d’antenne énumérés ci-dessous et ayant un gain admissible maximal et l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur. Pulse/Larsen W1027 Polarization ..................................................... .......................................................................................................... Vertical Composite gain ............................................... .......................................................................................................... 3.2 dBi Impedance .................................................... ......................................................................................................... 50 ohms Pulse/Larsen W1038 Polarization ..................................................... .......................................................................................................... Vertical Composite gain ............................................... ..........................................................................................................3.8 dBi Impedance .................................................... ......................................................................................................... 50 ohms L-Com model HG2403RD-RSF Polarization ..................................................... .......................................................................................................... Vertical Composite gain ............................................... ...........................................................................................................3.0 dBi Impedance .................................................... ......................................................................................................... 50 ohms BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 31 of 32 *8200-1088-15* PRELIMINARY FCC ID: BVCBIM1000 This device complies with part 15 of the FCC Rules. This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. México NOM 121: BIM1000 La operación de este equipo está sujeta a las siguientes dos condiciones: 1) es posible que este equipo o dispositivo no cause interferencia perjudicial y 2) este equipo debe aceptar cualquier interferencia, incluyendo la que pueda causar su propia operación no deseada. INTERNATIONAL ID: BIM1000 EMC ....................................................... .................................................................................................... 47 CFR, Part 15 ............................................................................................................................................................................ EN 300 328 ......................................................................................................................................................................... EN 301 489-1 ......................................................................................................................................................................... EN 301 489-3 ....................................................................................................................................................................... EN 301 489-17 ................................................................................................................................................................................ RSS 210 Safety.............................................................................................................................................................. UL/EN 60950-1 ................................................................................................................................................................................... CSA C22.2.60950-1 EQUIPMENT MODIFICATION CAUTION: Equipment changes or modifications not expressly approved by Sensormatic Electronics, LLC, the party responsible for FCC compliance, could void the user’s authority to operate the equipment and could create a hazardous condition. See About this guide on page 4. Other declarations WARRANTY DISCLAIMER: Sensormatic Electronics, LLC makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Further, Sensormatic Electronics, LLC reserves the right to revise this publication and make changes from time to time in the content hereof without obligation of Sensormatic Electronics, LLC to notify any person of such revision or changes. LIMITED RIGHTS NOTICE: For units of the Department of Defense, all documentation and manuals were developed at private expense and no part of it was developed using Government Funds. The restrictions governing the use and disclosure of technical data marked with this legend are set forth in the definition of “limited rights” in paragraph (a) (15) of the clause of DFARS 252.227.7013. Unpublished - rights reserved under the Copyright Laws of the United States. TRADEMARK NOTICE: Sensormatic is a registered trademark of Sensormatic Electronics, LLC. Other product names mentioned herein may be trademarks or registered trademarks of Sensormatic or other companies. No part of this guide may be reproduced in any form without written permission from Sensormatic Electronics, LLC. BUSINESS INTELLIGENCE MODULE (BIM1000) INSTALLATION GUIDE 8200-1088-15, REV 3E 32 of 32 *8200-1088-15*
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 32 Language : en-US Tagged PDF : Yes XMP Toolkit : 3.1-701 Producer : Microsoft® Word 2016 Title : Wireless Device Manager Installation Guide, 8z095803a Creator : Mary White Creator Tool : Microsoft® Word 2016 Create Date : 2018:03:09 09:06:04-05:00 Modify Date : 2018:03:09 09:06:04-05:00 Document ID : uuid:C9A92639-CFCE-4C38-8D4C-4ADB2392475A Instance ID : uuid:C9A92639-CFCE-4C38-8D4C-4ADB2392475A Author : Mary White Keywords : AMS-1180/1175/1170, camera kit, installation guide, synergy, antennaEXIF Metadata provided by EXIF.tools