Tyco Safety Sensormatic BIM1000 Business Intelligence Module User Manual

Tyco Safety Products/Sensormatic Business Intelligence Module

Contents

User manual

Download: Tyco Safety Sensormatic BIM1000 Business Intelligence Module User Manual
Mirror Download [FCC.gov]Tyco Safety Sensormatic BIM1000 Business Intelligence Module User Manual
Document ID3778029
Application IDcbGBz2CIk86XxzeUwdt1vw==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize103.31kB (1291328 bits)
Date Submitted2018-03-13 00:00:00
Date Available2018-03-13 00:00:00
Creation Date2018-03-09 09:06:04
Producing SoftwareMicrosoft® Word 2016
Document Lastmod2018-03-09 09:06:04
Document TitleWireless Device Manager Installation Guide, 8z095803a
Document CreatorMicrosoft® Word 2016
Document Author: Mary White

PRELIMINARY
Business Intelligence Module (BIM1000)
Installation Guide
BIM1000
© 2018 Sensormatic Electronics, LLC
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-03 REV 3E
1 of 32
*8200-1088-03*
PRELIMINARY
Contents
About this guide ..................................................................................................................................... 4
Additional documentation .................................................................................................................... 4
Technical Support ............................................................................................................................... 4
About the product ....................................................................................................................................... 5
Features .............................................................................................................................................. 5
Compatibility ........................................................................................................................................ 5
Section I: Installation sequence overview ................................................................................................ 7
Section II: Before you begin ....................................................................................................................... 8
Installation prerequisites ....................................................................................................................... 8
Training................................................................................................................................................ 8
Part numbers .......................................................................................................................................... 8
Survey and planning requirements ...................................................................................................... 9
Survey requirements ........................................................................................................................... 9
Network Topology Map requirements ................................................................................................. 9
Application and firmware requirements ............................................................................................... 9
TrueVUE requirements ...................................................................................................................... 10
Laptop requirements ......................................................................................................................... 10
Component installation requirements ............................................................................................... 10
Electrical power requirements ........................................................................................................... 10
Wiring requirements .......................................................................................................................... 10
Tools required ................................................................................................................................... 11
Safety ..................................................................................................................................................... 11
Section III: Installing the Business Intelligence Module (BIM1000) ..................................................... 12
Overview of steps ................................................................................................................................. 12
Step 1: Locating the Business Intelligence Module ......................................................................... 12
Step 2: Mounting the Business Intelligence Module ........................................................................ 13
Mounting the Business Intelligence Module to a hollow cavity wall .................................................. 13
Mounting the Business Intelligence Module to the ceiling ................................................................ 14
Mounting the Business Intelligence Module to a surface-mounted electrical box ............................ 17
Step 3: Connecting and securing the Business Intelligence Module ............................................. 18
Section IV: Connecting the Business Intelligence Module (BIM1000) ................................................. 20
Overview of connection steps ............................................................................................................ 20
Equipment required ............................................................................................................................. 20
Step 1: Connecting the Business Intelligence Module .................................................................... 21
Ethernet cable set-up ........................................................................................................................ 21
USB set-up ........................................................................................................................................ 23
Step 2: Optional: Installing a cellular modem ................................................................................... 25
Step 3: Commissioning the Business Intelligence Module ............................................................. 26
Step 4: Powering on the Business Intelligence Module ................................................................... 28
Step 5: Verifying the Business Intelligence Module ......................................................................... 29
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-03 REV 3E
2 of 32
*8200-1088-03*
PRELIMINARY
Specifications ............................................................................................................................................ 30
Declarations ............................................................................................................................................... 31
Other declarations ................................................................................................................................ 32
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-03 REV 3E
3 of 32
*8200-1088-03*
PRELIMINARY
About this guide
This installation guide explains how to install the Business Intelligence Module (BIM1000) with the Business
Intelligence Accessory (BIX1000), to synchronize all Sensormatic-connected devices.
Additional documentation
The following is a list of additional documents related to this installation:
 Business Intelligence Accessory (BIX1000) Installation Guide, 8200-1088-15.
 Business Intelligence Module (BIM1000) and Business Intelligence Accessory (BIX1000) Setup Guide,
8200-1088-01.
 Ultra Post® IV AMS-1012 Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide,
8200-1088-05.
 Ultra Post® VI AMS-1014 Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide,
8200-1088-06.
 Ultra 1.8 Meter ABS Pedestal Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide,
8200-1088-07.
 AMB9010-IPS and AMB-1200 Label Deactivator Controller Business Intelligence Accessory (BIX1000)
Cable Kit Installation Guide, 8200-1088-08.
 AMS-9050 Controller Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide,
8200-1088-09.
 AMS-9040 Controller Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide,
8200-1088-10.
 AMS-9060 Controller and AMS-1170-2C/4C Controller Business Intelligence Accessory (BIX1000) Cable
Kit Installation Guide, 8200-1088-11.
 ZBSMPROE ScanMax® Pro Label Deactivator Controller Business Intelligence Accessory (BIX1000) Cable
Kit Installation Guide, 8200-1088-12.
 IDKM-10XX/AMK-10XX SuperTag® Detacher Business Intelligence Accessory (BIX1000) Cable Kit
Installation Guide, 8200-1088-13.
 AMB-2011/AMB-1101/ZBAMB9010 EAS Label Deactivator Business Intelligence Accessory (BIX1000)
Cable Kit Installation Guide, 8200-1088-16.
 Business Intelligence Accessory (BIX1000) Extension Cable Kit Installation Guide, 8200-1088-14.
Technical Support
For product bulletins, and the most recent updates to this guide, visit https://sensormaticsecurelogin.com
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-03 REV 3E
4 of 32
*8200-1088-03*
PRELIMINARY
About the product
The Business Intelligence Module (BIM1000) is a wireless access point that connects to the Business
Intelligence Accessory (BIX1000).
Using IEEE 802.15.4 wireless protocol, the Business Intelligence Accessory (BIX1000) connects to the
Business Intelligence Module (BIM1000) to synchronize all in-store Sensormatic-connected devices, to collect
data and to provide a health status for all connected devices. For an example, see Figure 1 and Figure 2 on
page 6.
The data collected includes alarms, events, and people-counting statistics. It also collects alarm response
times to help eliminate false deactivation and detection alarms at store exits.
Customers can use a desktop browser to log into a TrueVUE reporting platform, or a Shrink Management as a
Service (SMaaS) platform, to access daily data reports from all the connected devices.
The customer can also use the Device Mobile App (BIZ1000), which is compatible with iOS and Android smart
devices, or they can use the Business Intelligence Module (BIM1000) Manager Interface, to monitor store-wide
EAS device health, counts, and events in real-time.
Features
The Business Intelligence Module (BIM1000) has the following features:








An embedded web configurator.
A wired EAS Network (RS-485).
A wireless EAS Network, 802.15.4
A wireless 802.11.B/G/N (Client and Soft AP).
It can support 32 devices.
It has MicroSD flash storage.
It has Micro USB Type B access.
It has Bluetooth radio for wireless setup.
Commented [ARB1]: Comment from Marc:
It has mmd so same format but a chip not a card. Clarify with
Marc.
Compatibility
The Business Intelligence Module (BIM1000) is compatible with the following devices:
















The Ultra Post® IV AMS-1012 Pedestal.
The Ultra Post® VI AMS-1014 Pedestal.
The Ultra 1.8 Meter ABS Pedestal.
The AMS-9060 Controller.
The AMS-9050 Controller.
The AMS-9040 Controller.
The AMS-1080 Controller.
The AMS-1170-2C/4C Controller.
The ZBAMB9010 EAS Label Deactivator Controller.
The AMB9010-IPS EAS Label Deactivator Controller.
The ZBSMPROE ScanMax® Pro Label Deactivator Controller.
The AMB-1200C EAS Label Deactivator Controller.
The AMK-1000 and the AMK-1010 SuperTag® Detacher.
The IDKM-1000 and the IDKM-1010 SuperTag® Detacher.
The AMB-2011 Value Pad II Countertop EAS Label Deactivator.
The AMB-1101 VersaPass II Countertop EAS Label Deactivator.
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-03 REV 3E
5 of 32
*8200-1088-03*
PRELIMINARY
Figure 1. Overview of the Business Intelligence Module (BIM1000) solution
802.11 Wi-Fi
802.15.4 WiFi
Internet
Gateway
Network switch
Wireless Access Point (802.11 Wi-Fi)
LP Manager
Business Intelligence Accessory (BIX1000)
Business Intelligence Module (BIM1000)
Figure 2. Business Intelligence Module (BIM1000), 0304-0170-01
Speaker
Micro USB port
Radio antenna (802.15.4)
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
RGB visual display
Locking tab
Wi-Fi antenna
8200-1088-03 REV 3E
6 of 32
*8200-1088-03*
PRELIMINARY
Section I: Installation sequence overview
Figure 3 gives an overview of the complete installation sequence you must follow when you install a BIM1000 and a BIX1000. You must install the
BIM1000 before you install the BIX1000.
Figure 3. BIM1000 and BIX1000 complete installation sequence
Step 2:
Step 1:
Before you begin:
Commission the
Install the
Planning and
BIX1000
BIM1000
prerequisites
Confirm all the
prerequisites in
Section II are
complete before
beginning
installation
Install the
BIM1000. Turn
on the BIM1000,
and program the
PAN ID and the
Channel
Step 5:
Validate BIM1000
configuration
Step 6:
Validate BIM1000
remote connectivity
Validate the
complete
BIM1000 and
BIX1000
configuration
Validate the
remote
connectivity
and data
transportation
of the BIM1000
Commission
the BIX1000
Step 3:
Install the BIX1000
cable kits
Install the
relevant
BIX1000 cable
kit, and
configure the
EAS devices
Commented [BA[G-C2]: Feedback from Marc, survey and
planning should be a pre-step. Store layout, which BIX to
which BIM, Network and RS-485 topology.
Step 4:
Install and locate
the BIX1000
Install and
locate the
BIX1000
Important: This installation guide only describes the following steps in the complete BIM1000 and BIX1000 installation sequence:




Before you begin: Planning and prerequisites
Step 1: Install the BIM
Step 5: Validate the BIM1000 configuration
Step 6: Validate BIM1000 remote connectivity
BUSINESS INTELLIGENCE ACCESSORY (BIX1000)
INSTALLATION GUIDE
8200-1088-03, REV 2C
7 of 32
*8200-1088-15*
PRELIMINARY
Section II: Before you begin
Before you install a Business Intelligence Module (BIM1000), ensure that you adhere to the criteria outlined in
the following sections.
Installation prerequisites
To install a Business Intelligence Module (BIM1000), you must have the following criteria in place before you
proceed:
 Do you have the Network Topology Map requirements, or IP Request Form?
 Do you have the location of each BIM1000 identified? You can obtain this information from the Network
Typology Map.
 Is there power and data, for example Ethernet, Wi-Fi, or 4G gateways, where you plan on locating the
BIM1000?
 Do you have the applicable network ports open for functionality and device management support?
 Have you completed the necessary training required to install the Business Intelligence Module (BIM1000)?
Training
WARNING: Do not attempt to install a Business Intelligence Module (BIM1000) unless you have completed the
Wireless Device Manager (BIM/BIX) Training Curriculum.
To install a Business Intelligence Module (BIM1000), you must complete the following technical training
modules:
 BIM and BIX Installation Technical Training.
 BIM Configuration Technical Training.
 Optional: SMaaS Overview Sales Training.
Part numbers
Table 1 lists the part numbers you require to install a Business Intelligence Module (BIM1000).
Table 1. Business Intelligence Module (BIM1000) part numbers
Part number
0352-0766-01
1400-0033-01
1400-0205-01
2838-0015-01
2880-0070-01
2880-0094-01
0304-0170-01
0404-1247-01
3411-0027-01
0352-0473-01
0404-1244-01
3135-1525-01
0352-0897-01
6003-0313-01
Description
BIM1000 Installation Kit
T-bar clip
T-bar clip, 1/4-20, 5/8” L, 15/16” W
Flange nut, 1/4-20, 7/16 WAF
Toggle bolt, 1/4-20 x 6.00
Anchor, self-drill, with screws, #8 x 1-1/4
BIM1000 module
BIM1000 mounting bracket
Antenna
Ceiling mount, IVS
BIX mounting back cover kit
BIM Power Supply
BIM PWR connector-cable
Micro USB B to USB-B cable, 1.8m
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
Quantity
Commented [ARB3]: These part numbers are not included
in the BOM Marc sent me. Are these going to be included in
the BOM or do they need to be ordered separately?
Could you please provide the part number for the power
connector cable, I cannot locate it on Windchill?
8200-1088-15, REV 3E
8 of 32
*8200-1088-15*
PRELIMINARY
Survey and planning requirements
This section outlines the site survey and planning requirements, and the systems requirements that are critical
to the correct installation of a BIM1000.
Survey requirements
Commented [BA[G-C4]: Question for Marc Blanchenay:
You must access the following criteria before you proceed with the installation of a BIM1000:
Does the installer need to do this or will it be included in the
Network Typology Map?
 The layout and design of the installation site.
 The location of each BIM1000 module. You can obtain this information from the Network Typology Map.
 Identify each BIX1000 you need to program to each BIM1000 module.
Network Topology Map requirements
You require the following information for each device you place on the network when you install a Business
Intelligence Module (BIM1000) to work with a Business Intelligence Accessory (BIX1000). This information is in
the Network Topology Map that the project manager or the coordinator for the account supplies, or in the IP
Request form document that the customer’s IT department supplies.













The location of each BIM1000 module.
The switch location, name and port number.
Any Wi-Fi restrictions, if setting up the BIM1000 to operate in Access Point (AP) mode.
The Wi-Fi channel.
Note: The Wi-Fi channel is dependent on the region of installation.
The Wi-Fi access point location and the Service Set Identifier (SSID).
A static or a dynamic IP address.
The Subnet Mask.
The Gateway
The NTP Server.
The Ethernet MAC address.
The Wi-Fi Subnet Mask.
The Wi-Fi Default Gateway.
The SIP Server address.
Application and firmware requirements
In order to support the installation of a Business Intelligence Module (BIM1000), you must download the latest
firmware bundle, 1.00 or later, and the BIM Web Launch Tool from https://sensormaticsecurelogin.com/.
To download the BIM Web Launch Tool, complete the following steps:
1. Open a web browser and launch https://sensormaticsecurelogin.com/.
2. Enter your valid logon information and click Login.
3. From the Tech Support menu, click EAS.
4. Click Software Download.
5. Click BIM Web Launch Tool Vx.xx
6. To download the software bundle, click the link, and save the file to a local folder on your laptop.
7. Log out of www.sensormaticsecurelogin.com/.
8. On your laptop, rename the file you saved to an .exe file. Click the executable file, and click Run.
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
9 of 32
*8200-1088-15*
PRELIMINARY
9. Follow the setup wizard instructions to save the software on your laptop.
Note: Files save to the following location: C:\Program Files\Sensormatic\BIM Software Bundle
x.x. (Program Files (x86) for 64 bit machines).
TrueVUE requirements
To support TrueVUE reports for a Business Intelligence Module (BIM1000) installation, you require the
following:
 TrueVUE ,version 7.5 or later.
Commented [ARB5]: Included as per conversion with John
Clark. 7.5 is scheduled for release in April.
 The SIP URL as stated in the Network Topology Map.
 If authentication is necessary, you need your valid service credentials.
 The store name, the store number, and the division number.
 The heartbeat interval.
 Ensure the appropriate port is open, typically port 8080 or 8081.
Commented [ARB6]: Removed the wireless adapter and
the Bluetooth adapter from this list. Wi-Fi and Bluetooth are
disabled by default so moving these sections to the Setup
Guide.
Laptop requirements
You require the following items for your laptop:
 Internet Explorer version 11, or Mozilla Firefox version 56, or Google Chrome version 64, browser installed.
Note: Ensure JavaScript are blockers on the web browser.
 A USB port.
 An Ethernet adapter.
Component installation requirements
This section outlines components installation requirements to install a Business Intelligence Module
(BIM1000).
Electrical power requirements
Confirm the following electrical power requirements are in place to install a Business Intelligence Module
(BIM1000):
 The AC power cord could be carrying 120Vac or 240Vac. The AC source must be a 2-wire type with
ground. It also must be a 24-hour, unswitched outlet with less than 0.5Vac between neutral and ground.
Note: The BIM1000 takes its Sync signal from this AC power source.
 The BIM1000 can operate from generator supplied AC power if it meets the AC power requirements.
Important: You must select Generator Mode when configuring the BIM1000 for use in multiple generator
environments.
Wiring requirements
Confirm the following wiring requirements are in place for each piece of hardware before you install a Business
Intelligence Module (BIM1000):
 RS-485 cabling, including the termination of cabling, the pinouts, and a diagram with RS485-High,
RS485-Low, and Sync connections outlined.
 All Ethernet patch cables must be CAT5e, CAT6, or CAT6e.
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
10 of 32
*8200-1088-15*
PRELIMINARY
Tools required
Confirm that you have the following tools before you install a Business Intelligence Module (BIM1000):
 A #2 Philips head screwdriver.
 A cable tester.
 A Digital Volt Meter.
 A micro USB cable, 6003-0313-01, or an Ethernet patch cable.
 A drill, and assorted drill-bits.
 A drywall saw.
Safety
You must adhere to the following safety instructions when you install a Business Intelligence Module
(BIM1000):
WARNING: Risk of electric shock
Disconnect all power sources before servicing.
 Do not install the Business Intelligence Module (BIM1000) in a plenum or other environmental air-handling
space.
 You must use plenum-rated cables, unless the cables are in raceways.
 Installation of the BIM1000 must comply with the latest national electrical codes, national fire code, and all
applicable local codes and ordinances. National or local wiring codes may differ between regions.
Adherence to these codes supersedes instructions in this document.
 You must observe and respect all the safety instructions in this installation guide, and or the operation of the
Business Intelligence Module (BIM1000).
 You must mount the Business Intelligence Module (BIM1000) only as instructed in this installation guide.
Mounting the Business Intelligence Module (BIM1000) any other way can affect its operation.
 The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications
to this equipment. Such modifications can void the user’s authority to operate the equipment.
 You must install the antennas for this transmitter with a separation distance of at least 20 centimetres (8
inches) from all persons, and must not be collocated or operating in conjunction with any other antenna or
transmitter.
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
11 of 32
*8200-1088-15*
Commented [ARB7]: Reply from Bill Owsley:
We have not yet received the FCC certificate and expect it by
months end.
Because the application has the 2 antennas in it, I would
guess the certificate might not have that statement.
TBD.
PRELIMINARY
Section III: Installing the Business Intelligence
Module (BIM1000)
This section outlines how to install a Business Intelligence Module (BIM1000).
Important: You must install the Business Intelligence Module (BIM1000) before you install the Business
Intelligence Transceiver (BIX1000).
Note: You can power on and set-up the Business Intelligence Module (BIM1000) before you install it. To do
this, proceed to Step 4: Powering on the Business Intelligence Module on page 28.
Overview of steps
This section gives an overview of the steps involved in installing a Business Intelligence Module (BIM1000):
 Step 1: Locating the Business Intelligence Module (BIM1000).
 Step 2: Mounting the Business Intelligence Module (BIM1000).
 Step 3: Connecting and securing the Business Intelligence Module (BIM1000).
Step 1: Locating the Business Intelligence Module
To locate the Business Intelligence Module (BIM1000) correctly, you must adhere to the following guidelines
when you locate the Business Intelligence Module (BIM1000).
 Locate the BIM1000 a minimum of 2 feet or 24 inches from the Business Intelligence Transceiver
(BIX1000). For more information, refer to the Business Intelligence Accessory (BIX1000) Installation Guide,
8200-1088-15.
Commented [BA[G-C8]: For the moment starting with this
value. Manny will get back to me once tests are performed
over the coming weeks. (05/02/18)
 Table 2 lists the expected maximum line of sight range from BIM1000 to BIM1000 modules, and from
BIM1000 to BIX1000 modules. The maximum line of sight ranges are based on environments free of
obstructions and interference, the range can significantly degrade from the specified maximums.
Table 2. Expected maximum line of sight ranges between modules
Modules
Region
Expected maximum line of sight range
BIM1000 to BIX1000
BIM1000 to BIX1000
BIM1000 to BIX1000EA
BIM1000 to BIM1000
BIM1000 to BIM1000
EU
US
EU
EU
US
76.2 meters (250 feet)
106.7 meters (350 feet)
106.7 meters (350 feet)
182.9 meters (600 feet)
370 meters (1,217 feet)
 You must install the antennas for this transmitter with a separation distance of at least 20 centimetres
(8 inches) from all persons, and must not be collocated or operating in conjunction with any other antenna
or transmitter.
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
12 of 32
*8200-1088-15*
Commented [ARB9]: TBD.
PRELIMINARY
Step 2: Mounting the Business Intelligence Module
You can mount the Business Intelligence Module (BIM1000) in one of the following ways:
 To a hollow cavity wall.
 To a ceiling.
 To a surface-mounted electrical box.
Mounting the Business Intelligence Module to a hollow cavity wall
To mount the Business Intelligence Module (BIM1000) to wall with a hollow cavity, you require the following
equipment:






A Ceiling Mount IVS Kit, 0352-0473-01.
A BIM Mounting Plate, 0404-1247-01, supplied with the Business Intelligence Module (BIM1000).
A #2 Phillips screwdriver.
A 2-inch (5 centimeters) bell saw, or hole saw.
A drill, with assorted drill bits.
A drywall saw.
To mount a Business Intelligence Module (BIM1000) to a hollow cavity wall, complete the following steps:
1. Locate the BIM Mounting Bracket, 0404-1247-01, and orientate it with the arrows pointing up to the ceiling,
as shown in Figure 4.

Important: You must locate the Business Intelligence Module (BIM1000) a minimum of 2 feet (24 inches)
from the Business Intelligence Accessory (BIX1000).
2. Use the BIM Mounting Bracket, 0404-1247-01, as a template and with a pencil, mark the mounting holes,
and the Power, the Ethernet, and the RS485 cable entry holes. See Figure 4.
Figure 4. Front view of the BIM Mounting Bracket, 0404-1247-01
Mounting holes
Power cable opening
RS485 cable opening
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
Arrow up indicators
Ethernet cable opening
8200-1088-15, REV 3E
13 of 32
*8200-1088-15*
PRELIMINARY
3. Use a hand drill and a 2-inch (5 centimeters) drill-bit to drill the mounting holes on the wall.
4. Use a bell saw, or a hand saw, to cut out the Power, the Ethernet, and the RS485 cable holes.
5. From the Ceiling Mount IVS Kit, 0352-0473-01, locate two drywall anchors, 2880-0094-01, and insert into
the mounting holes in the wall.
Commented [WM[G-C10]: Is this the correct drill-bit size
for the mounting holes?
Commented [WM[G-C11]: Are these the correct anchors
from the kit? There’s two types.
6. To prepare the cabling, complete the following steps:
a. Locate the RS-485 cable and feed it through the RS485 cable opening on the BIM Mounting Bracket,
0404-1247-01.
b. Secure the RS485 cable into the strain relief notch. See Figure 5.
Figure 5. BIM Mounting Bracket cable strain relief feature
c. Feed the Ethernet cable through the Ethernet cable opening on the BIM Mounting Bracket,
0404-1247-01.
d. Secure the Ethernet cable into the strain relief notch. See Figure 5.
e. Locate the three-pin connector cable from the XXXXX Kit and feed it through the Power cable opening
on the BIM Mounting Bracket, 0404-1247-01.
Commented [WM[G-C12]: Where does the installer get the
three-pin connector cable?
7. Secure the three-pin connector from the power cable into the strain relief notch. See Figure 5.
8. Correctly orientate the BIM Mounting Bracket in place, with the up arrows pointing to the ceiling.
9. From the Ceiling Mount IVS Kit, 0352-0473-01, locate two drywall anchor screws, 2880-0094-01, and use a
#2 Phillips screwdriver to secure the BIM Mounting Bracket, 0404-1247-01, to the wall.
Mounting the Business Intelligence Module to the ceiling
To mount the Business Intelligence Module (BIM1000) to the ceiling, you require the following equipment:




A BIM1000 Install Kit, 0352-0766-01.
A BIM1000 Mounting Bracket, 0404-1247-01, supplied with the Business Intelligence Module (BIM1000).
A drill with assorted drill bits.
Plywood or a strut channel.
You can mount the Business Intelligence Module (BIM1000) to a hard ceiling, a T-bar of a ceiling grid support,
or a suspended ceiling panel using the BIM Mounting Bracket, 0404-1247-01.
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
14 of 32
*8200-1088-15*
Commented [WM[G-C13]: Are these the correct anchors
from the kit? There’s two types.
PRELIMINARY
Mounting the BIM1000 Mounting Bracket to a hard ceiling
To mount the Business Intelligence Module (BIM1000) to a hard ceiling complete the following steps:
1. Locate the BIM1000 Mounting Bracket, 0404-1247-01 and the BIM1000 Installation Kit, 0352-0766-01.
2. If possible, mount the BIM Mounting Bracket into a known structural member using appropriate hardware.
Alternately, use the supplied toggle bolt, 2880-0070-01, to anchor the BIM1000 Mounting Bracket.
3. Use the BIM Mounting Bracket, 0404-1247-01, as a template and with a pencil, mark the mounting holes,
and the Power cable entry hole.
Commented [BA[G-C14]: Should this step sit here or do I
need to move it? Or is this a note?
a. If required, mark the entry locations for the RS485 or the Ethernet patch cables.
4. Use a drill with a 1/2 inch (12.5 millimeter) drill-bit, and drill the mounting hole in the ceiling.
5. Use a drill with a 1/2 inch (12.5 millimeter) drill-bit, and drill a hole for the power cable. If required, also drill
a hole or holes for the RS485 or the Ethernet Patch cables.
6. From the BIM1000 Installation Kit, 0352-0766-01, locate the 6-inch toggle bolt, 2880-0070-01.
7. Adjust the toggle bolt to ensure it can expand once you place it through the ceiling, and ensure a minimum
of a 1/2 inch (12.5 millimeters) of the toggle bolt remains exposed below the ceiling.
8. Thread the BIM1000 Mounting Bracket, 0404-1247-01, onto the toggle bolt, 2880-0070-01, and insert it
through the ceiling.
9. Pulling down slightly on the bracket assembly, spin the BIM1000 Mounting Bracket to tighten it.
Note: If you have access to the area above the ceiling, you can tighten the toggle bolt, 2880-0070-01, from
this location.
10. Place an additional screw on the BIM1000 Mounting Bracket, 0404-1247-01, to prevent the bracket from
spinning or loosening when mounted. Alternately, place the flange nut, 2838-0015-01, from the BIM1000
Installation Kit, 0352-0766-01, above the toggle bolt to secure the bracket in place.
11. Complete the following steps to route the cables through the BIM1000 Mounting Bracket, 0404-1247-01:
a. If required, locate the RS-485 cable, feed it through the RS485 cable opening on the BIM Mounting
Bracket, 0404-1247-01, and then secure the RS485 cable in the provided strain relief notch. For the
location of the strain relief notch on the BIM1000, see Figure 5.
b. Locate the Ethernet cable and feed it through the Ethernet cable opening on the BIM Mounting Bracket,
0404-1247-01, and then secure the Ethernet cable in the provided strain relief notch.
c. Locate the power cable, feed the three-pin connector end of the cable through the Power cable opening
on the BIM Mounting Bracket, 0404-1247-01, and then secure the cable in the provided strain relief
notch.
Mounting the BIM1000 Mounting Bracket to a T-bar of a suspended ceiling support
To attach the BIM Mounting Bracket, 0404-1247-01, to a T-bar of a suspended ceiling support, complete the
following steps:
Commented [BA[G-C15]: What size drill bit?
1. Use a hand drill with a xx drill-bit, and drill a hole in the center of the plywood.
2. From the BIM1000 Installation Kit, 0352-0766-01, locate the 6-inch toggle bolt, 2880-0070-01.
3. Insert the toggle bolt, 2880-0070-01, through the plywood, and tighten the two flanged nuts,
2838-0015-01, to secure it to the BIM Mounting Bracket, 0404-1247-01.
4. Sit the plywood across the grid support in the ceiling.
5. From the BIM1000 Installation Kit, 0352-0766-01, locate the two T-bar clips, 1400-0033-01, and clip onto
the ceiling grid support to secure in place.
6. Complete the following steps to route the cables through the BIM1000 Mounting Bracket, 0404-1247-01:
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
15 of 32
*8200-1088-15*
PRELIMINARY
a. If required, locate the RS-485 cable, feed it through the RS485 cable opening on the BIM Mounting
Bracket, 0404-1247-01, and then secure the RS485 cable in the provided strain relief notch. For the
location of the strain relief notch on the BIM1000, see Figure 5.
b. Locate the Ethernet cable and feed it through the Ethernet cable opening on the BIM Mounting Bracket,
0404-1247-01, and then secure the Ethernet cable in the provided strain relief notch.
c. Locate the power cable, feed the three-pin connector end of the cable through the Power cable opening
on the BIM Mounting Bracket, 0404-1247-01, and then secure the cable in the provided strain relief
notch.
Mounting the BIM1000 Mounting Bracket to a suspended ceiling panel
To attach the BIM Mounting Bracket, 0404-1247-01, to a suspended ceiling panel, complete the following
steps:
Commented [BA[G-C16]: What size drill bit?
1. Use a hand drill with a xx drill-bit, and drill a hole in the center of the plywood.
2. From the BIM1000 Installation Kit, 0352-0766-01, locate the 6-inch toggle bolt, 2880-0070-01.
3. Insert the toggle bolt, 2880-0070-01, through the plywood, and tighten the two flanged nuts,
2838-0015-01, to secure it to the BIM Mounting Bracket, 0404-1247-01.
4. Sit the plywood across the grid support in the ceiling.
5. From the BIM1000 Installation Kit, 0352-0766-01, locate the two T-bar clips, 1400-0033-01, and clip onto
the ceiling grid support to secure in place.
6. Complete the following steps to route the cables through the BIM1000 Mounting Bracket, 0404-1247-01:
a. If required, locate the RS-485 cable, feed it through the RS485 cable opening on the BIM Mounting
Bracket, 0404-1247-01, and then secure the RS485 cable in the provided strain relief notch. For the
location of the strain relief notch on the BIM1000, see Figure 5.
b. Locate the Ethernet cable and feed it through the Ethernet cable opening on the BIM Mounting Bracket,
0404-1247-01, and then secure the Ethernet cable in the provided strain relief notch.
c. Locate the power cable, feed the three-pin connector end of the cable through the Power cable opening
on the BIM Mounting Bracket, 0404-1247-01, and then secure the cable in the provided strain relief
notch.
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
16 of 32
*8200-1088-15*
PRELIMINARY
Mounting the Business Intelligence Module to a surface-mounted
electrical box
To mount the Business Intelligence Module (BIM1000) using a surface-mounted electrical box, you require the
following equipment:
 A BIM1000 Installation Kit, 0352-0766-01.
 A BIM Mounting Plate, 0404-1247-01, supplied with the Business Intelligence Module (BIM1000).
 Electrical boxes: For North America, a contractor can supply quad-type electrical boxes or you can source
them locally. For all other geographies, refer to the mounting pattern in Figure 6 to determine the supported
locally available electrical boxes.
Figure 6. Mounting hole dimensions on BIM1000 mounting bracket, back view
8.5 cm
8.4 cm
8.5
cm
4.6 cm
8.3
cm
6 cm
To mount the Business Intelligence Module (BIM1000) using an electrical box, complete the following steps:
1. Locate the Mounting Bracket, 0404-1247-01, and orientate it with the arrows pointing up to the ceiling. See
Figure 4.
2. If the electrical box is not mounted, mount the electrical box using appropriate hardware.
3. Remove one or more knockouts on the electrical box.
4. Add strain relief to the knockouts where necessary to prevent the cables from chafing, and then secure the
cable entry at the electrical box.
5. Complete the following steps to route the cables through the BIM1000 Mounting Bracket, 0404-1247-01:
a. If required, locate the RS-485 cable, feed it through the RS485 cable opening on the BIM Mounting
Bracket, 0404-1247-01, and then secure the RS485 cable in the provided strain relief notch. For the
location of the strain relief notch on the BIM1000, see Figure 5.
b. Locate the Ethernet cable and feed it through the Ethernet cable opening on the BIM Mounting Bracket,
0404-1247-01, and then secure the Ethernet cable in the provided strain relief notch.
c. Locate the power cable, feed the three-pin connector end of the cable through the Power cable opening
on the BIM Mounting Bracket, 0404-1247-01, and then secure the cable in the provided strain relief
notch.
Note: Installing the Business Intelligence Module (BIM1000) to a 4x4 electrical box provides additional
depth for cable connectors.
6. Orientate the Mounting Bracket, 0404-1247-01, with the arrows pointing up, over the electrical box.
5. Use two screws supplied with the electrical box, or two screws compatible with the electrical box, and
secure the BIM Mounting Bracket, 0404-1247-01, to the electrical box.
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
17 of 32
*8200-1088-15*
PRELIMINARY
Step 3: Connecting and securing the Business Intelligence
Module
To secure the Business Intelligence Module (BIM1000) to the Mounting Bracket, 0404-1247-01, complete the
following steps:
1. Locate the Business Intelligence Module (BIM1000).
2. Insert the three-pin connector from the power cable to the Power port on the back of the Business
Intelligence Module (BIM1000). See Figure 7.
Figure 7. Back view of the BIM Mounting Bracket, 0404-1247-01
Reset button
Ethernet port
Locking tab
Power port
RS485 port
Tamper switch
3. Insert the Ethernet cable to the Ethernet port on the back of the Business Intelligence Module (BIM1000).
See Figure 7.
4. Insert the RS485 cable to the RS485 port on the back of the Business Intelligence Module (BIM1000). See
Figure 7.
5. Align the Business Intelligence Module (BIM1000) to the BIM Mounting Bracket, 0404-1247-01. See Figure
8 on page 19.
6. Insert the Business Intelligence Module (BIM1000) to the BIM Mounting Bracket, 0404-1247-01, and rotate
counter-clockwise to engage the locking tab.
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
18 of 32
*8200-1088-15*
PRELIMINARY
Figure 8. Securing the Business Intelligence Module (BIM1000) to the BIM Mounting Bracket,
Removing the Business Intelligence Module from the mounting bracket
To remove the Business Intelligence Module (BIM1000) from the Mounting Bracket, 0404-1247-01, complete
the following steps:
1. Use a small, flat screw driver to push lightly on the tamper switch on the left-hand side of the Business
Intelligence Module (BIM) to disengage the locking tab.
2. Rotate the Business Intelligence Module (BIM) counter-clockwise to release it from the Mounting Bracket,
0404-1247-01.
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
19 of 32
*8200-1088-15*
PRELIMINARY
Section IV: Connecting the Business Intelligence
Module (BIM1000)
This section outlines how to connect the Business Intelligence Module (BIM1000).
Commented [WM[G-C17]: Bill to check hardware
Overview of connection steps
This section gives an overview of the steps involved in connecting a Business Intelligence Module (BIM1000).
 Step 1: Connecting the Business Intelligence Module.
 Step 2: Installing a cellular modem.
 Step 3: Configuring the Business Intelligence Module.
 Step 4: Powering on the Business Intelligence Module.
 Step 5: Verifying the Business Intelligence Module.
Equipment required
To connect the Business Intelligence Module (BIM1000), you require the following equipment:
 ?
 ?
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
20 of 32
*8200-1088-15*
PRELIMINARY
Step 1: Connecting the Business Intelligence Module
You can connect and power the Business Intelligence Module (BIM1000) in the following ways:
 An Ethernet cable set-up
 A USB set-up
 A Wi-Fi set-up
 A Bluetooth set-up
Note: Wi-Fi and Bluetooth are disabled by default. To connect to the BIM1000 module using Wi-Fi or
Bluetooth set-up, refer to the Business Intelligence Module (BIM1000) and Business Intelligence Accessory
(BIX1000) Setup Guide, 8200-1088-01.
Ethernet cable set-up
To connect a Business Intelligence Module (BIM1000) using an Ethernet cable set-up, complete the following
procedure:
1. Connect the Ethernet cable to your laptop and to the Business Intelligence Module (BIM1000).
2. You can connect to the Business Intelligence Module (BIM1000) in one of the following ways:

Use the BIM Web Launch Tool to connect to the Business Intelligence Module (BIM1000) using the
BIM Web Launch Tool, by completing the following steps:
a.
On your laptop, open the BIM Web Launch Tool.
b.
From the Network Adapter list, select the relevant Ethernet connection type.
c.
In the IP Address field, enter 192.168.0.100
d.
Click Launch.
Note: This launches a web browser to connect to the Business Intelligence Module
(BIM1000).
Figure 9. BIM1000 Web Interface Launcher

Use the laptop network settings to connect to the Business Intelligence Module (BIM1000) using the
laptop’s network settings, by completing the following steps:
a. Complete the following steps to navigate to the laptop’s network settings:
i.
Click Start.
ii.
Click Control Panel.
iii.
Click Network and Internet.
iv.
Click Network and Sharing Center.
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
21 of 32
*8200-1088-15*
PRELIMINARY
v.
Ensure that the laptop’s network matches the following network settings for the
BIM1000:

BIM default IP address: 192.168.0.100

BIM default Gateway: 192.168.0.254

BIM default Subnet mask: 255.255.255.0
b. Complete the following steps to verify that the laptop’s IP address is on the same subnet as
the Business Intelligence Module (BIM1000):
c.
i.
Click the Network icon on your desktop toolbar.
ii.
Click Local Area Connection.
iii.
Click Properties.
iv.
Click Internet Protocol Version 4 (TCp/IPv4).
v.
Click Properties.
vi.
Click Use the following IP address.
vii.
In the IP address field, enter 192.168.0.100
viii.
In the Subnet mask field, enter 255.255.255.0 and click OK.
On the laptop, launch an internet browser.
d. In the internet address bar, enter the following IP address of the Business Intelligence
Module (BIM1000), 192.168.0.100
Note: When it connects, the Wireless Device Configuration webpage displays.
4. To logon to the Business Intelligence Module (BIM1000) for the first time, you require a password. To
obtain a password, complete the following steps:
a. In the User Login pane, click Generate to generate a challenge string.
Note: The generated string is valid for one week only. Do not click the Generate Challenge String
button more than once, if you click the button more than once, you need to obtain another string.
b. Copy the string that is generated in the Generate Challenge String field.
5. Launch an internet browser and navigate to https://sensormaticsecurelogin.com/.
6. Enter your valid logon details, and click Login.
7. Read the Terms & Conditions, and if you agree, select the check box and click Agree.
8. From the Tech Support menu, click Configurator Registration, and complete the following steps:
a. From the Product Code list, click AMS-9060 Web Configuration UI.
b. In the Register Number field, enter the generated challenge string you copied in step 4b.
c.
Click Submit.
Note: A challenge string and service password is sent to the email you registered.
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
22 of 32
*8200-1088-15*
PRELIMINARY
USB set-up
To connect a Business Intelligence Module (BIM1000) using a micro USB cable, 6003-0313-01, complete the
following steps:
1. Connect the micro USB cable, 6003-0313-01, to your laptop and to the Business Intelligence Module
(BIM1000). For the location of the micro USB port on the BIM1000, see item C, in Figure 2.
2. You can connect to the Business Intelligence Module (BIM1000) in one of the following ways:

Use the BIM Web Launch Tool to connect to the Business Intelligence Module (BIM1000) using the
BIM Web Launch Tool, by completing the following steps:
a. On your laptop, open the BIM Web Launch Tool.
b. From the Network Adapter list, select the relevant Ethernet connection type.
c.
In the IP Address field, enter 192.168.2.100
d. Click Launch.
Note: This launches a web browser to connect to the Business Intelligence Module
(BIM1000).

Use the laptop network settings to connect to the Business Intelligence Module (BIM1000) using the
laptop’s network settings, by completing the following steps:
a.
Complete the following steps to navigate to the laptop’s network settings:
i.
Click Start.
ii.
Click Control Panel.
iii.
Click Network and Internet.
iv.
Click Network and Sharing Center.
v.
Ensure that the laptop’s network matches the following network settings for
the BIM1000:



b.
BIM default IP address: 192.168.2.10
BIM default Gateway: 192.168.0.254
BIM default Subnet mask: 255.255.255.0
Complete the following steps to verify that the laptop’s IP address is on the same subnet as
the Business Intelligence Module (BIM1000):
i.
Click the Network icon on your desktop toolbar.
ii.
Click Local Area Connection.
iii.
Click Properties.
iv.
Click Internet Protocol Version 4 (TCp/IPv4).
v.
Click Properties.
vi.
Click Use the following IP address.
vii.
In the IP address field, enter 192.168.2.100
viii.
In the Subnet mask field, enter 255.255.255.0 and click OK.
c.
On the laptop, launch an internet browser.
d.
In the internet address bar, enter the following IP address of the Business Intelligence
Module (BIM1000), 192.168.2.100
Note: When it connects, the Wireless Device Configuration webpage displays.
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
23 of 32
*8200-1088-15*
PRELIMINARY
4. To logon to the Business Intelligence Module (BIM1000) for the first time, you require a password. To
obtain a password, complete the following steps:
a. In the User Login pane, click Generate to generate a challenge string.
Note: The generated string is valid for one week only. Do not click the Generate Challenge String
button more than once, if you click the button twice, you need to obtain another string.
b. Copy the string that is generated in the Generate Challenge String field.
5. Launch an internet browser and navigate to https://sensormaticsecurelogin.com/.
6. Enter your valid logon details, and click Login.
7. Read the Terms & Conditions, and if you agree, select the check box and click Agree.
8. From the Tech Support menu, click Configurator Registration, and complete the following steps:
a. From the Product Code list, click AMS-9060 Web Configuration UI.
b. In the Register Number field, enter the generated challenge string you copied in step 4b.
c.
Click Submit.
Note: A challenge string and service password is sent to the email you registered.
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
24 of 32
*8200-1088-15*
PRELIMINARY
Commented [WM[G-C18]: Check with Marc Blanchenay
Step 2: Optional: Installing a cellular modem
This step is optional if you chose to install a cellular modem.
To install a cellular modem, follow the instructions that come with the cellular modem.
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
25 of 32
*8200-1088-15*
PRELIMINARY
Step 3: Commissioning the Business Intelligence Module
This section outlines how to commission a Business Intelligence Module (BIM1000):
To commission the BIM1000, complete the following steps:
1. Return to the Business Intelligence Module webpage, and use the challenge string to generate the service
password, if necessary. See Step 1: Connecting the Business Intelligence Module.
2. From the BIM Configuration menu, click BIM Status. Ensure that the versions and information in the
following fields are correct, and click Save.
a.
Software Version – 00.07.1, or higher
b.
Bootloader Version – 00.00.5, or higher
c.
IP Address – 192.168.0.100
3. If you need to update the firmware on the BIM1000, complete the following steps:
a. From the BIM Configuration menu, click Firmware Update.
b. Click Browse, and select the BIM_BIX_RADIO_CFG_WEB_X_XX tar file.
Note: X_XX in the tar file indicates the latest version of the firmware.
c. Click Download.
d. Wait for a Transfer Completed Successfully dialog box to open, and then click OK.
e. Click Update.
f. If the update does not complete successfully, repeat steps a, b, c, d, and e.
Note: If you the BIM1000 does not update successfully, you may be instructed to perform a factory
reset. For further information, contact Technical Support. If you need to perform a factory reset,
complete the following steps:
i.
From the BIM Configuration menu, click Radio Settings.
ii.
Record the values for the Pan ID, Channel, and Power, and then click Save.
iii.
From the BIM Configuration menu, click BIM Status.
iv.
Click Factory Reset.
v.
Verify that the following firmware version updated successfully:
 Software Version: 00.07.1
 Bootloader version: 00.00.5
 Radio version: 00.32.7
 Wi-Fi version: 2.9.0.0
vi.
From the BIM Configuration menu, click Radio Settings, and restore the radio settings.
4. From the BIM Configuration menu, click Network Settings, and enter static IP information, or check the
DHCP option to get an assigned IP address.
5. Optional: If required, select the Enable HTTP SSL check box to enable SSL on the web server.
6. From the BIM Configuration menu, click Radio Settings and complete the following steps:
a.
In the PAN ID field, enter a value in hex from 0 x 0001 through to 0 x FFFE.
Note: The Personal Area Network (PAN) ID must be unique for each BIM1000.
b.
In the Channel field, enter the Channel.
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
26 of 32
*8200-1088-15*
PRELIMINARY
Note: The Channel must be unique for each BIM1000. You can set a value from 1 to 26 for IEEE
802.15.4 radio frequencies.
c.
Optional: Click Generate to generate a PAN ID and Channel.
d.
In the Tx Power field, enter the Tx power value for the country of use, as shown in Table 3.
Table 3. BIM1000 and BIX1000 TX power
Device
BIM1000
BIX1000
BIX1000EA
e.
TX power, North America
197 (20dB)
197 (20dB)
220 (20db)
TX power, Europe
57 (10dB)
78 (10dB)
89 (10db)
Click Save.
INSTALLATION GUIDE
8200-1088-15, REV 3E
27 of 32
Commented [ARB20]: Needs to be ironed out, and John A
to include a country dropdown menu. To be decided.
Commented [ARB21]: Bill Rider to confirm
Note: Write down the PAN ID and Channel details to use later on when you configure the BIX1000.
BUSINESS INTELLIGENCE MODULE (BIM1000)
Commented [BA[G-C19]: Marc mentioned that this differs
from Wi-Fi, do I need to note this here and do they need to
use a different value.
*8200-1088-15*
PRELIMINARY
Commented [WM[G-C22]: Bill Rider to provide
Step 4: Powering on the Business Intelligence Module
To power on the Business Intelligence Module (BIM1000), complete the following procedure:
1. Plug it in
2. When LEDs blinking
3.
4.
Power Cable Route
The power cable route goes from:
 The AC outlet inside the main electrical box in which the power supply module (1) and female-to-female
coupler (2) reside.
 Down through existing conduit into the UltraLink enclosure below.
®
 Up through existing conduit and alarm module electrical box (3).
 To a 4x4 electrical box (4) mounted 3.7m (12ft) from the floor (the Sync AP mounts here using two screws
as shown below). A length of conduit (5) will need to be added for power to reach this box.
Notes:
The 4.6m (15ft) Cat5 cable supplied is used to get power to the Sync AP.
DO NOT connect this cable to the Sync AP or the female-to-female coupler inside the main electrical box at
this time. These connections will be done at the end of the setup process.
If the cable does not fit through the conduit, then cut off one of its connectors close to the end of the cable,
route the cable, then reattach the connector (see page 5 for reattachment instructions).
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
28 of 32
*8200-1088-15*
PRELIMINARY
Step 5: Verifying the Business Intelligence Module
To verify that the Business Intelligence Module (BIM1000) is functioning correctly, complete the following
procedure:
1. Launch an internet browser.
2. In the address bar, enter 192.168.1.100 and press enter. The Business Intelligence Module (BIM) Web
Interface opens.
3. From the User dropdown list, click Service.
4. In the Password field, enter the password.
Commented [WM[G-C23]: Is this the password that the
customer set earlier?
5. In the BIM Status pane, verify the following:
a. Verify the Number of Devices.
b. Verify the Number of Devices Online.
Note: If the Business Intelligence Module is functioning correctly, the Number of Devices and the
Number of Device online match.
c. In the SIP Server Status pane, verify the last connection time and success percentage.
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
29 of 32
*8200-1088-15*
PRELIMINARY
Specifications
Electrical
Power supply
Primary input .........................................................................................................................................................................
............................................................... 18VDC input, Sync and RS485 through RJ45 8 pin header with LEDs for RS485.
Environmental
Ambient temperature ....................................................... ........................................................ 0°C to 50°C (14°F to 122°F)
Relative humidity ............................................................. ............................................................ 0 to 90% non-condensing
Enclosure Rating ............................................................. ..................................................................................... UL94 V-O
Evaluated for altitudes less than 2,000 meters (6,561.68 feet)
Mechanical
Material: ........................................................................... ..............................................................................................ABS
Color: .............................................................................. ..................................................................................... Light grey
Dimensions: .................................................................... ........................................ 139.52 mm X 114.76 mm X 62.10 mm
Weight (approx.): ............................................................ ............................................................................ 419 g (0.92 lbs)
Dimensions
Figure 10. Business Intelligence Module (BIM) dimensions, front view
138.82 mm
(5.5 in)
81.50 mm
(3.2 in)
114.76 mm
(4.5 in)
139.52 mm
(5.5) in
94.50 mm
(3.7 in)
62.10 mm
(2.4 in)
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
30 of 32
*8200-1088-15*
PRELIMINARY
Declarations
Model: BIM1000
Regulatory information
Contains the following radios;
FCC ID: A8TBM78ABCDEFGH, Z64-CC3100MODR1
IC ID: 12246A-BM78SPPS5M2, 451I-CC3100MODR1
Radio
Frequency of operation
Type.......................................................... ............................................................................................................. BIM1000
Frequency band............................. .................................................................................................... . 2402.0 - 2480.0 MHz
.............................................................................................................................................................2412.0 – 2462.0 MHz
Maximum power ................................... ..................................................................................................... 10 mW in the EU
........................................................................................................................................................................ 100 mW in NA
If frequency is selectable for your model, select only the country in which you are using the device. Any other selection will make the
operation of this device illegal.
Approved antennas
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain
approved for the transmitter by Industry Canada.
To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically
radiated power (e.i.r.p.) is not more than that necessary for successful communication.
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain
maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada.
Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain
de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire
à l’établissement d’une
communication satisfaisante.
This radio transmitter IC: 3506A-BIM1000 has been approved by Industry Canada to operate with the antenna types listed below with the
maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having
a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
Le présent émetteur radio IC: 3506A-BIM1000 a été approuvé par Industrie Canada pour fonctionner avec les types d’antenne énumérés
ci-dessous et ayant un gain admissible maximal et l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans
cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur.
Pulse/Larsen W1027
Polarization ..................................................... .......................................................................................................... Vertical
Composite gain ............................................... .......................................................................................................... 3.2 dBi
Impedance .................................................... ......................................................................................................... 50 ohms
Pulse/Larsen W1038
Polarization ..................................................... .......................................................................................................... Vertical
Composite gain ............................................... ..........................................................................................................3.8 dBi
Impedance .................................................... ......................................................................................................... 50 ohms
L-Com model HG2403RD-RSF
Polarization ..................................................... .......................................................................................................... Vertical
Composite gain ............................................... ...........................................................................................................3.0 dBi
Impedance .................................................... ......................................................................................................... 50 ohms
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
31 of 32
*8200-1088-15*
PRELIMINARY
FCC ID: BVCBIM1000
This device complies with part 15 of the FCC Rules. This device complies with Industry Canada’s licence-exempt RSSs.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
México NOM 121: BIM1000
La operación de este equipo está sujeta a las siguientes dos condiciones:
1) es posible que este equipo o dispositivo no cause interferencia perjudicial y
2) este equipo debe aceptar cualquier interferencia, incluyendo la que pueda causar su propia operación no deseada.
INTERNATIONAL ID: BIM1000
EMC ....................................................... .................................................................................................... 47 CFR, Part 15
............................................................................................................................................................................ EN 300 328
......................................................................................................................................................................... EN 301 489-1
......................................................................................................................................................................... EN 301 489-3
....................................................................................................................................................................... EN 301 489-17
................................................................................................................................................................................ RSS 210
Safety.............................................................................................................................................................. UL/EN 60950-1
................................................................................................................................................................................... CSA C22.2.60950-1
EQUIPMENT MODIFICATION CAUTION: Equipment changes or modifications not expressly approved by Sensormatic Electronics,
LLC, the party responsible for FCC compliance, could void the user’s authority to operate the equipment and could create a hazardous
condition.
See About this guide on page 4.
Other declarations
WARRANTY DISCLAIMER: Sensormatic Electronics, LLC makes no representation or warranty with respect to the contents hereof
and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Further, Sensormatic
Electronics, LLC reserves the right to revise this publication and make changes from time to time in the content hereof without
obligation of Sensormatic Electronics, LLC to notify any person of such revision or changes.
LIMITED RIGHTS NOTICE: For units of the Department of Defense, all documentation and manuals were developed at private
expense and no part of it was developed using Government Funds. The restrictions governing the use and disclosure of technical data
marked with this legend are set forth in the definition of “limited rights” in paragraph (a) (15) of the clause of DFARS 252.227.7013.
Unpublished - rights reserved under the Copyright Laws of the United States.
TRADEMARK NOTICE: Sensormatic is a registered trademark of Sensormatic Electronics, LLC. Other product names mentioned
herein may be trademarks or registered trademarks of Sensormatic or other companies.
No part of this guide may be reproduced in any form without written permission from Sensormatic Electronics, LLC.
BUSINESS INTELLIGENCE MODULE (BIM1000)
INSTALLATION GUIDE
8200-1088-15, REV 3E
32 of 32
*8200-1088-15*

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 32
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Microsoft® Word 2016
Title                           : Wireless Device Manager Installation Guide, 8z095803a
Creator                         : Mary White
Creator Tool                    : Microsoft® Word 2016
Create Date                     : 2018:03:09 09:06:04-05:00
Modify Date                     : 2018:03:09 09:06:04-05:00
Document ID                     : uuid:C9A92639-CFCE-4C38-8D4C-4ADB2392475A
Instance ID                     : uuid:C9A92639-CFCE-4C38-8D4C-4ADB2392475A
Author                          : Mary White
Keywords                        : AMS-1180/1175/1170, camera kit, installation guide, synergy, antenna
EXIF Metadata provided by EXIF.tools
FCC ID Filing: BVCBIM1000

Navigation menu