Typical Operational Readings
835A 4 kW, 5 kW or 6 kW UHF Transmitter Typical Operational Readings (A1) Single UHF Exciter Assembly (A1-A6) Metering Control Panel, 835A Transmitter Combined Reflected (0 - 120%) = < 5 % Visual (0 - 120%) = 100 % Aural (0 - 120%) = 100 % Reject (0 - 120%) = < 5 % Amplifier Array Side A Reflected (0 - 120%) = < 5 % Forward (0 - 120%) = as needed to attain 100% Amplifier Array Side B Reflected (0 - 120%) = < 5 % Forward (0 - 120%) = as needed to attain 100% (A1-A1) UHF Exciter Tray Audio (0 - 100 kHz) = ±25 Bal or ±75 kHz Stereo % Exciter (0 - 120%) = ≈30 % Video (0 - 1 V) = 1 Vpk-pk at White ALC (0 - 1 V) = .8 V (A1-A4) Phase/Gain Tray Side A % Power (0 - 120%) = ≈50 % ALC (0 - 1 V) = .6 - 1 V Typical (A1-A5) Phase/Gain Tray Side B % Power (0 - 120%) = ≈50 % ALC (0 - 1 V) = .6 - 1 V Typical (A2 & A3) Amplifier Array Assemblies, 4kW, 5kW or 6kW Two Amplifier Arrays, each with for, five or six UHF Amplifier Trays (A2) Side A (A2-A1) 4kW, 5kW & 6kW (A2-A2) 4kW, 5kW & 6kW AGC Voltage = 1 V - 2 V AGC Voltage = 1 V - 2 V % Reflected = < 5 % with all Trays operating. % Reflected = < 5 % with all Trays operating. % Output Forward = The level is as needed to attain 100% Output Power from the Transmitter. % Output Forward = The Level is as needed to attain 100% Output Power from the Transmitter. Power Supply = 26.5 V Power Supply = 26.5 V - Page 1 of 3 - 835A 4 kW, 5 kW or 6 kW UHF Transmitter Typical Operational Readings (A2 & A3) Amplifier Array Assemblies, 4kW, 5kW or 6kW Two Amplifier Arrays, each with four, five or six UHF Amplifier Trays (A2) Side A - Continued (A2-A3) 4kW, 5kW & 6kW (A2-A4) 4kW, 5kW & 6kW AGC Voltage = 1 V - 2 V AGC Voltage = 1 V - 2 V % Reflected = < 5 % with all Trays operating. % Reflected = < 5 % with all Trays operating. % Output Forward = The level is as needed to attain 100% Output Power from the Transmitter. % Output Forward = The Level is as needed to attain 100% Output Power from the Transmitter. Power Supply = 26.5 V Power Supply = 26.5 V (A2-A5) 5kW & 6kW (A2-A6) 6kW AGC Voltage = 1 V - 2 V AGC Voltage = 1 V - 2 V % Reflected = < 5 % with all Trays operating % Reflected = < 5 % with all Trays operating % Output Forward = The level is as needed to attain 100% Output Power from the Transmitter. % Output Forward = The level is as needed to attain 100% Output Power from the Transmitter. Power Supply = 26.5 V Power Supply = 26.5 V (A3) Side B (A3-A1) 4kW, 5kW & 6kW (A3-A2) 4kW, 5kW & 6kW AGC Voltage = 1 V - 2 V AGC Voltage = 1 V - 2 V % Reflected = < 5 % with all Trays operating % Reflected = < 5 % with all Trays operating. % Output Forward = The level is as needed to attain 100% Output Power from the Transmitter. % Output Forward = The Level is as needed to attain 100% Output Power from the Transmitter. Power Supply = 26.5 V Power Supply = 26.5 V (A3-A3) 4kW, 5kW & 6kW (A3-A4) 4kW, 5kW & 6kW AGC Voltage = 1 V - 2 V AGC Voltage = 1 V - 2 V % Reflected = < 5 % with all Trays operating. % Reflected = < 5 % with all Trays operating. % Output Forward = The level is as needed to attain 100% Output Power from the Transmitter. % Output Forward = The Level is as needed to attain 100% Output Power from the Transmitter. Power Supply = 26.5 V Power Supply = 26.5 V - Page 2 of 3 - 835A 4 kW, 5 kW or 6 kW UHF Transmitter Typical Operational Readings (A2 & A3) Amplifier Array Assemblies, 4kW, 5kW or 6kW Two Amplifier Arrays, each with fou, five or six UHF Amplifier Trays (A3) Side B - Continued (A3-A5) 5kW & 6kW (A3-A6) 6kW AGC Voltage = 1 V - 2 V AGC Voltage = 1 V - 2 V % Reflected = < 5 % with all Trays operating. % Reflected = < 5 % with all Trays operating. % Output Forward = The level is as needed to attain 100% Output Power from the Transmitter % Output Forward = The level is as needed to attain 100% Output Power from the Transmitter. Power Supply = 26.5 V Power Supply = 26.5 V - Page 3 of 3 -
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2002:11:07 13:14:34-08:00 Modify Date : 2002:11:07 13:14:34-08:00 Page Count : 3 Creation Date : 2002:11:07 21:14:34Z Mod Date : 2002:11:07 21:14:34Z Producer : Acrobat Distiller 5.0.5 (Windows) Author : fcc Metadata Date : 2002:11:07 21:14:34Z Creator : fcc Title : Microsoft Word - 281880.DOCEXIF Metadata provided by EXIF.tools