UBS Axcera HU5000BTD 5000-Watt UHF Digital Transmitter User Manual

UBS-Axcera 5000-Watt UHF Digital Transmitter axciter Master 3 22 07

a href="https://usermanual.wiki/UBS-Axcera" itemprop="url"> UBS Axcera >

User manual 2

Digital ATSC Exciter-Modulator System Chapter 2,   Installation and Operating Instructions  Axcera Axciter, Rev. 0    28 DTVision Eye Screen  I-Signal Eye Display Graphic display of the eight data amplitude levels.  This can be used to monitor the demodulated 8VSB signal.  When signal is precise, the seven vertical "eyes" will appear (this display shows two sets). Linear or non-linear distortion in the modulator process will cause incorrect I-signal amplitude at center of "eye" pattern.  Transmitter distortion such as group delay, frequency tilt, or ripple will cause the "eye" to close and result in receiver data errors.  .