PT 5780 DVB-T Modulator
ProTelevision Technologies
Contents
Contents
1 SAFETY.................................................................................................................. 1-1
1.1
1.2
1.3
1.4
INTRODUCTION........................................................................................................ 1-1
SAFETY PRECAUTIONS ............................................................................................. 1-1
CAUTION AND W ARNING STATEMENTS ........................................................................ 1-1
IMPAIRED SAFETY PROTECTION ................................................................................. 1-2
1.4.1 Technical Specifications .............................................................................. 1-2
1.4.2 Equipment Ratings ...................................................................................... 1-3
1.5 ELECTROSTATIC S ENSITIVE D EVICES .......................................................................... 1-3
1.6 SYMBOLS ............................................................................................................... 1-4
2 INTRODUCTION AND APPLICATIONS........................................................... 2-1
2.1 APPLICATIONS ......................................................................................................... 2-1
2.1.1 Block Diagram (PT 5780 features)................................................................ 2-3
2.2 TRANSMISSION MODES S UPPORTED ........................................................................... 2-3
2.3 TRANSPORT S TREAM INPUTS ..................................................................................... 2-4
2.4 ALARM C IRCUITS ..................................................................................................... 2-6
2.5 OPERATION ............................................................................................................ 2-6
2.6 FREQUENCY REFERENCES ........................................................................................ 2-6
2.7 TEST FACILITIES ...................................................................................................... 2-7
3 INSTALLATION..................................................................................................... 3-1
3.1 INITIAL INSPECTION .................................................................................................. 3-1
3.2 SAFETY INSTRUCTION .............................................................................................. 3-1
3.2.1 Earthing...................................................................................................... 3-1
3.3 MAINS VOLTAGE CORD AND F USES ............................................................................ 3-1
3.4 RACK MOUNTING ..................................................................................................... 3-2
3.5 CLEANING .............................................................................................................. 3-2
3.6 CONFIGURATION ...................................................................................................... 3-3
3.6.1 Wiring schemes for RS 232 (handshake not implemented) ............................ 3-3
3.6.2 Alarms........................................................................................................ 3-3
3.6.3 Mute........................................................................................................... 3-4
3.6.4 Reset ......................................................................................................... 3-4
3.7 ACCESS TO AND R EPLACEMENT OF PARTS .................................................................. 3-4
3.7.1 Safety......................................................................................................... 3-4
3.7.2 Access to the Units...................................................................................... 3-4
4 OPERATING INSTRUCTIONS........................................................................... 4-1
4.1 FRONT PANEL ......................................................................................................... 4-1
4.1.1 Front Panel Indicators.................................................................................. 4-1
4.1.2 Front Panel Controls (The menu system)...................................................... 4-1
4.1.3 Front Panel Display ..................................................................................... 4-3
4.2 R EAR PANEL ........................................................................................................... 4-3
4.2.1 Rear Panel Connections .............................................................................. 4-3
4.3 MENU SYSTEM – D ESCRIPTION AND O PERATION .......................................................... 4-5
4.3.1 Power Up ................................................................................................... 4-5
4.3.2 Operating Menu System Chart ..................................................................... 4-6
4.3.3 Status Menu System ................................................................................... 4-6
4.3.3.1 Description of Status Display Windows ........................................... 4-7
Instruction Manual
Revision 3.11
PT 5780 DVB-T Modulator
4.4
4.5
4.6
4.7
ProTelevision Technologies
Contents
4.3.4 Configuration Menu System ....................................................................... 4-11
4.3.4.1 Top-level configuration menu access............................................ 4-12
4.3.4.2 Context sensitive menu access.................................................... 4-13
4.3.4.3 TRANSMISSION Menu System (Menu ID 1000) ........................... 4-14
4.3.4.4 SIGNAL Menu System (Menu ID 2000) ........................................ 4-15
4.3.4.5 ALARM Menu System (Menu ID 3000)......................................... 4-18
4.3.4.6 PRESET Menu System (Menu ID 4000) ....................................... 4-22
4.3.4.7 CONFIGURE Menu System (Menu ID 5000) ................................ 4-22
4.3.4.8 TEST SIGNAL Menu System (Menu ID 6000) ............................... 4-24
4.3.4.9 RECEPTION Menu System (Menu ID 7000) ................................. 4-25
4.3.4.10 EVENT LOG Menu System (Menu ID 8000) ................................. 4-27
4.3.5 Configuring Parameters ............................................................................. 4-27
4.3.5.1 Selection from Enumerated Values .............................................. 4-27
4.3.5.2 Editing of Numerical Values ......................................................... 4-28
4.3.5.3 Editing of Text............................................................................. 4-29
4.3.5.4 Editing of Percentage Values ....................................................... 4-30
FACTORY RESET ................................................................................................... 4-30
SFN MODE OF O PERATION ..................................................................................... 4-31
FATAL ALARMS...................................................................................................... 4-32
4.6.1 Modulator Board Controller Not Responding ............................................... 4-32
4.6.2 Instrument Too Hot .................................................................................... 4-32
ERROR HANDLING AND C ODES ................................................................................ 4-32
5 REMOTE INTERFACE......................................................................................... 5-1
5.1 GENERAL D ESCRIPTION............................................................................................ 5-1
5.2 GENERAL D ESCRIPTION OF THE INTERFACE SYNTAX ..................................................... 5-1
5.2.1 General Information..................................................................................... 5-1
5.2.2 Syntax of Program Messages ...................................................................... 5-2
5.2.3 Syntax of Response Messages .................................................................... 5-2
5.2.4 Long and Short Form................................................................................... 5-3
5.2.5 Syntax Elements ......................................................................................... 5-3
6 RS232 COMMUNICATION.................................................................................. 6-1
6.1 R EFERENCES .......................................................................................................... 6-1
6.2 COMMANDS EXPLANATION ........................................................................................ 6-1
6.2.1 Mandated Commands ................................................................................. 6-1
6.2.2 Required Commands ................................................................................... 6-2
6.2.2.1 SYSTem commands ..................................................................... 6-2
6.2.2.2 STATus commands ....................................................................... 6-2
6.2.3 Instrument Commands ................................................................................ 6-3
6.2.3.1 DIAGnostic commands .................................................................. 6-3
6.2.3.2 SYSTem commands ..................................................................... 6-3
6.2.3.3 USER commands ......................................................................... 6-5
6.2.3.4 DISPlay commands ....................................................................... 6-6
6.2.3.5 INPut commands .......................................................................... 6-6
6.2.3.6 OUTPut commands ....................................................................... 6-8
6.2.3.7 MONitor command ...................................................................... 6-13
6.2.3.8 PRECorrect (Nonlinear Pre-corrector) commands ......................... 6-13
6.2.3.9 LPRecorrect (Linear Pre-corrector) commands ............................. 6-17
6.2.3.10 SFN commands .......................................................................... 6-18
6.2.3.11 ALARM commands ..................................................................... 6-20
6.2.3.12 EVENT commands...................................................................... 6-23
Instruction Manual
Revision 3.11
ii
PT 5780 DVB-T Modulator
ProTelevision Technologies
Contents
6.2.3.13 TEST commands ........................................................................ 6-23
6.2.3.14 FACTORY commands ................................................................. 6-24
6.3 COMMANDS S UMMARY ........................................................................................... 6-25
6.3.1 Mandated Commands ............................................................................... 6-25
6.3.2 Required commands ................................................................................. 6-25
6.3.2.1 SYSTem subsystem.................................................................... 6-25
6.3.2.2 STATus subsystem..................................................................... 6-25
6.3.3 Instrument commands ............................................................................... 6-26
6.3.3.1 DIAGnostic subsystem ................................................................ 6-26
6.3.3.2 SYSTem subsystem.................................................................... 6-26
6.3.3.3 USER subsystem........................................................................ 6-26
6.3.3.4 DISPlay subsystem..................................................................... 6-26
6.3.3.5 INPut subsystem......................................................................... 6-27
6.3.3.6 OUTPut subsystem ..................................................................... 6-27
6.3.3.7 MONitor subsystem..................................................................... 6-29
6.3.3.8 PRECorrect (Nonlinear Pre-corrector) subsystem ......................... 6-29
6.3.3.9 LPRecorrect (Linear Pre-corrector) subsystem.............................. 6-29
6.3.3.10 SFN subsystem .......................................................................... 6-30
6.3.3.11 ALARm subsystem...................................................................... 6-30
6.3.3.12 EVENt subsystem....................................................................... 6-31
6.3.3.13 TEST subsystem ........................................................................ 6-31
6.3.3.14 FACTory subsystem.................................................................... 6-31
6.4 ERROR CODES ...................................................................................................... 6-32
6.4.1 Command errors [-199, -100] ..................................................................... 6-32
6.4.2 Execution errors [-299, -200] ...................................................................... 6-33
6.4.3 Device specific errors [-399, -300] .............................................................. 6-34
6.4.4 Query errors [-499, -400] ........................................................................... 6-34
6.4.5 Device specific errors [1, 32468] ................................................................ 6-34
APPENDIX A…...........................................................................................….A-1
APPENDIX B………………………………………………………………………..A-2
Instruction Manual
Revision 3.11
iii
PT 5780 DVB-T Modulator
ProTelevision Technologies
Contents
This page is intentionally left blank
Instruction Manual
Revision 3.11
iv
PT 5780 DVB-T Modulator
ProTelevision Technologies
Safety
Safety
Read this chapter carefully before installation and use of the instrument.
1.1
Introduction
The instrument described in this manual has been designed for use by properly trained
personnel only.
Adjustment, maintenance and repair of the exposed equipment should only be carried out by
qualified personnel who are aware of hazards involved.
1.2
Safety Precautions
For the correct and safe use of the instrument, it is essential that both operating and servicing
personnel follow generally accepted safety procedures in addition to the safety precautions
specified in this manual. Specific warning and caution statements, where applicable, are found
throughout this manual. Note that warning and caution statements and/or symbols are marked
on the instrument as well.
This manual provides technical information important for safe operation of the equipment.
Please refer to the relevant sections of the manual for technical specifications, installation and
operating instructions.
Special attention must be paid to the following issues:
♦ Protective earthing of the instrument is required for the accessible terminals to be safe.
(IEC 1010-1 Safety class I instrument)
♦ The actual environmental conditions must be checked against the specification
♦ Mains voltage must be inside the specified range
The opening of covers or removal of parts, except those to which access can be gained by
hand, is liable to expose live parts and terminals.
If adjustment, maintenance, or repair of the opened instrument is unavoidable, it must only be
carried out by a skilled person who is aware of the hazards involved.
1.3
Caution and Warning Statements
Caution
Used to indicate correct operation or maintenance in order to prevent damage to, or destruction
of equipment or other property.
Warning
Used to indicate a potential hazard that requires correct procedures or practices in order to
prevent personal injury.
Instruction Manual
Revision 3.11
1-1
Safety
ProTelevision Technologies
1.4
Impaired Safety Protection
1.4.1
Technical Specifications
PT 5780 DVB-T Modulator
This manual provides technical information important for safe operation of the equipment.
Please refer to the Chapter Product Data for information regarding technical specifications and
the Chapter Installation and Operating Instructions regarding instructions for use.
Technical assistance may be obtained from your local ProTelevision Technologies customer
support organization or from:
ProTelevision Technologies
Marielundvej 16
DK-2730 Skovlunde
Denmark
Phone
: +45 4470 0000
Fax
: +45 4470 0001
E-Mail
: helpdesk@protelevision.com
Website
: http://www.protelevision.com
Instruction Manual
Revision 3.11
1-2
PT 5780 DVB-T Modulator
1.4.2
ProTelevision Technologies
Safety
Equipment Ratings
The instrument can be used with a mains voltage supply of:
Voltage range:
90 – 132VAC / 180 - 250 V AC
Frequency:
47 - 63 Hz
The power consumption:
Does not exceed 50 VA
The instrument is designed for the following environmental conditions:
♦ Indoor use
♦ Altitudes up to 2000 m
♦ Temperatures between 5 C and 40 C
Maximum relative humidity of 80% for temperatures up to 31 C, decreasing linearly to 50%
relative humidity at 40 C.
The instrument is equipped with a number of input and output terminals as described in the
Chapter Product Data.
The terminals are protected from becoming hazardous live by means of basic insulation and
protective screening.
Whenever it is likely that safe operation is impaired, the instrument must be made inoperative
and secured against unintended operation. The appropriate servicing authority must be
informed.
For example, safety is likely to be impaired if the instrument fails to perform the intended
measurements or shows visible damage.
WARNING: Protection provided by the equipment may be impaired, if the equipment is used in
a manner not specified by this manual.
ATTENTION
1.5
Electrostatic Sensitive Devices
All ICs and many other semi-conductors are susceptible to electrostatic discharges ESD).
Careless handling during repair can reduce lifetime drastically.
When repairing, make sure that you are connected to the same potential as the mass of the set
via a wrist wrap with resistance. Keep components and tools also at this potential.
Instruction Manual
Revision 3.11
1-3
Safety
1.6
ProTelevision Technologies
PT 5780 DVB-T Modulator
Symbols
Symbol
Colour:
Explanation:
Red
High voltage terminal: a terminal at which a voltage, with
respect to another terminal or parts exists or may be
adjusted to 1000 V or more. (High voltage > 1000 V).
Black/Yellow
Live part shock risk of electric shock.
Black/Yellow
To preserve the instrument from damage the operator
must refer to an explanation in the instruction manual.
White/Black
Protective earth (grounding) terminal.
Black
Alternating current (placed on the identification plate).
Off (supply - mains switch).
White/Black
On (supply - mains switch).
Instruction Manual
Revision 3.11
1-4
PT 5780 DVB-T Modulator
ProTelevision Technologies
Introduction and Applications
Introduction and Applications
Designed to meet the most demanding requirements of today’s Digital Terrestrial Television
Broadcast Market, the DVB-T Modulator PT 5780 from ProTelevision Technologies is ranked
number one in its class. A key factor in the products success is the quality of the coding and
modulation process. The unit is furthermore highly flexible and therefore easily tailored to
provide the exact features required in a specific application. This means that you will only have
to pay for the functional features that you need. Retrofitting of features is easy. Normally, the
retrofitting only involves uploading new firmware and software by means of a standard PC.
2.1
Applications
The performance and flexibility of the PT 5780 allows it to excel in any application related to
DVB-T modulation. Being a DVB-T modulator the core function of the PT 5780 is to modulate
an MPEG-2 transport stream (input) onto a DVB-T compliant COFDM spectrum (output) in
accordance with the rules for channels coding and modulation specified in the DVB-T standard
ETSI EN 300 744.
Basic version
The basic version of the PT 5780 delivers the COFDM spectrum on a user-defined frequency
between 35 and 37 MHz. The default polarity of the spectrum is ‘Inverted’ as normal for a DVBT IF signal. However, the user can freely switch the polarity to ‘non-inverted’ if required. The
spectrum bandwidth may be user configured to 8 or 7MHz as required. This flexibility will allow
the user to interface the IF signal to a wide range of transmitters and frequency converters.
The basic unit has two MPEG-2 inputs (ASI format). Switching between the two inputs can be
done manually and automatically. The latter option provides near seamless switching to a
secondary transport stream in case the primary transport stream source fails (a truly valuable
feature for broadcast applications.)
The user can configure the basic version to any transmission mode listed in ETSI EN 300 744
(excluding hierarchical mode and SFN mode.)
Optional features
A broad range of optional features allows tailoring the modulator for the specific application.
If the output COFDM spectrum is required on a frequency not covered by the basic version (3537MHz) the RF Converter option PT 8715 is the answer. This high performance converter
covers the entire frequency range from 30MHz to 1GHz in steps of just 1Hz. The user can freely
set the polarity of the spectrum to inverted or Non-inverted as required. With this converter the
PT 5780 will cover any spectrum application and frequency requirement that you will come
across in the field of DVB-T.
To upgrade the PT 5780 for SFN transmission you will only need to add the SFN option PT
8732. This option provides the PT 5780 with market leading SFN performance with respect to
basic timing accuracy and extent of the local delay offset range. Also, even when the SFN
option is installed you can still select MFN mode via the front panel controls. A convenient
feature when conducting pre-testing and alignment of RF parameters on transmitter installations
before the timing references and transport stream with MIP are in place (as a general rule SFN
modulators must mute the output if either of these signals is absent).
Instruction Manual
Revision 3.11
2-1
Introduction and Applications
ProTelevision Technologies
PT 5780 DVB-T Modulator
To extend the standard range of transmission modes to include support of hierarchical
modulation the Hierarchical Modulation option PT 8733 must be added. Hierarchical
modulation allows simultaneous transmission of two MPEG-2 transport streams. The
compromise between data rate and ruggedness can be set differently between the two virtual
channels. For example:
• a highly protected channel for transmission to mobile and/or portable receivers and
• a high capacity channel, at the expense of ruggedness, for transmission to rooftop
antennas.
Another typical application is simulcasting of the same program in high definition resolution and
standard definition resolution. A significant benefit of hierarchical modulation is that the total
data-rate available in a system with two hierarchically modulated RF channels is higher than
what is available for a two-channel non-hierarchical system where one RF channel is strictly
dedicated to mobile/portable receivers and the other RF channel is strictly dedicated for
transmission to rooftop antennas.
The hierarchical option itself is often supplemented by adding also an extra set of ASI inputs
(dual input option PT 8716) thereby upping the total to four ASI inputs. Access to four ASI
inputs will preserve the possibility also in hierarchical mode to switch almost seamlessly to a
secondary transport stream source in case the primary transport stream source fails (HP
primary input, HP secondary input, LP primary input, LP secondary input).
By adding the 6MHz BW option PT 8735 the PT 5780 will, in addition to the standard 8 and 7
MHz BW, also support transmission in the 6MHz bandwidth mode that is intended for
applications in North and South America, Korea, Japan and elsewhere where 6MHz channel
raster is standard. Including this option for T&M and R&D applications is also highly attractive
as the user simply executes the switching between the three bandwidths via the instrument front
panel (one instrument covers all bandwidths defined by the ETS for DVB-T transmission).
To maximise the performance of the transmitter in which the modulator is installed the Digital
Linear and Non-linear Pre-corrector PT 8731 option is recommended. The Non-linear precorrector balances out gain and phase non-linearity in the transmitter RF power amplifier
thereby reducing significantly the in-band as well as out of band intermodulation generated by
the amplifier. This optimisation of the performance will extend the transmitters coverage area
and ease the performance requirement from the transmitter output filter used for suppressing
the radiation in adjacent channels below the maximum allowed level. The linear pre-corrector
balances out level and group delay variations over the channel bandwidth caused by the
transmitter antenna filter and/or channel combiner filers. The linear optimisation of the signal
radiated from the transmitter means that the channel equalizer of the DVB-T receiver may focus
all its correction capacity on level and group delay errors originating from the actual
transmission path. The characteristics of the linear and non-linear pre-correction curves are set
by means of an easy to use and highly intuitive graphical user interface, the IMD Buster
software package (Windows compatible).
Two options for remote control of the PT 5780 exist. The WebLink option PT 8717 allows
remote control of the PT 5780 via Ethernet (TCP/IP). The system is based on a Web server
mounted inside the PT 5780. The Web pages stored on the Web server are designed as a
complete graphical user interface (GUI) for testing the status and setting the parameters of the
modulator. The WebLink concept is popular because remote control with this system only
requires a standard PC with a network interface card (NIC) and a Web browser (Microsoft
Explorer 5.0). The SNMP client option PT 8727 allows remote control of the PT 5780 in
Instruction Manual
Revision 3.11
2-2
PT 5780 DVB-T Modulator
ProTelevision Technologies
Introduction and Applications
accordance with the SNMP protocol (Get, Set and SNMP traps). This remote control option is
intended for systems solutions where it is desired to integrate the control of a range of (SNMP
compliant) equipment in a common management system, the SNMP manager. The
management system must be adapted/designed to the specific systems requirements and it is
therefore not included with the supplied SNMP client option.
2.1.1
Block Diagram (PT 5780 features)
DVB-T Modulator
PT 5780
IFmonitoring
ASI input-B
ASI input-A
36 MHz
OPTION PT 8723
SPI LVDS input
TS source selector
Rev 3.0 23.01.2003
u/5780/work/hso/manual V3/drawings/5788 block diagram (features).vsd
MPEG-2 TS
COFDM
modulator
(8+7MHz BW,
MFN)
OPTION PT 8715
RF converter
(RF
301000
MHz)
LP
System controller
(Local and remote)
OPTION PT 8720
Precision TCXO
0.01ppm
RS232 for SCPI
control
OPTION PT 8717
WebLink for Web
browser control
2.2
IF
3537
MHz
HP
RS232 for SCPI
control
or
Optionally RJ45
for Ethernet
OPTION PT 8727
SNMP Client
OPTION PT 8731
Digital Linear
and
Non-linear
Pre-correction
OPTION
PT 8732
SFN Support
OPTION
PT 8735
8-7-6 MHz BW
OPTION
PT 8733
Hierarchical
modulation
Transmission Modes Supported
♦ MFN mode and SFN mode (SFN requires option PT 8732)
♦ 6, 7, 8 MHz (6MHz requires option PT 8735)
♦ FFT size: 2k or 8k
♦ Guard Interval: 1/4, 1/8, 1/16, and 1/32
♦ Code Rates: 1/2, 2/3, 3/4, 5/6, and 7/8
♦ Modulation Constellations: QPSK (4 QAM), 16 QAM, and 64 QAM
♦ Hierarchical α 1, 2, 4 (hierarchical mode requires option PT 8733)
Instruction Manual
Revision 3.11
2-3
Introduction and Applications
2.3
ProTelevision Technologies
PT 5780 DVB-T Modulator
Transport Stream Inputs
The standard version of the PT 5780 DVB-T modulator is provided with two serial (ASI) inputs.
By non-hierarchical mode the active input is selected either via the front panel or the remote
control. By hierarchical mode one input is assigned to the high priority stream and the other
input is assigned to the low priority stream. The inputs accept an MPEG transport stream
according to the DVB recommendation. Both 188 and 204 byte transport packets are supported
(in the 204 byte mode the last 16 bytes are always overwritten by the Reed-Solomon
redundancy data generated by the modulator). The available data rate for transmission is stated
in the tables below in accordance with the selected constellation, code rate and guard interval.
Please notice that separate tables applies to 8MHz , 7MHz, and 6MHz bandwidth respectively.
By hierarchical mode 64 QAM constellation and 16QAM constellation can be selected. The
available data rate is divided between the high priority channel and the low priority channel. The
bit rate for the high priority channel is equal to the capacity stated in the QPSK section of the
applicable table irrespective of the constellation chosen. For the low priority channel the
capacity depends on the chosen constellation (64Qam or 16QAM). By 64QAM constellation the
capacity of the hierarchical low priority channel is equal to the capacity stated in the 16QAM
section of the applicable table. By 16QAM constellation the capacity of the hierarchical low
priority channel is equal to the capacity stated in the QPSK section of the applicable table.
In Table 2-1 the maximum useful bit rates are indicated for all valid transmission modes in an
8 MHz system.
Modulation
QPSK
16-QAM
64-QAM
Code rate
½
2/3
¾
5/6
7/8
½
2/3
¾
5/6
7/8
½
2/3
¾
5/6
7/8
1/4
4,98
6,64
7,46
8,29
8,71
9,95
13,27
14,93
16,59
17,42
14,93
19,91
22,39
24,88
26,13
Guard interval
1/8
1/16
5,53
5,85
7,37
7,81
8,29
8,78
9,22
9,76
9,68
10,25
11,06
11,71
14,75
15,61
16,59
17,56
18,43
19,52
19,35
20,49
16,59
17,56
22,12
23,42
24,88
26,35
27,65
29,27
29,03
30,74
1/32
6,03
8,04
9,05
10,05
10,56
12,06
16,09
18,10
20,11
21,11
18,10
24,13
27,14
30,16
31,67
Table 2-1 Available data rate for 8MHz DVB-T
Instruction Manual
Revision 3.11
2-4
PT 5780 DVB-T Modulator
ProTelevision Technologies
Introduction and Applications
In Table 2-2 the maximum useful bit rates are indicated for all valid transmission modes in a
7 MHz system.
Modulation
QPSK
16-QAM
64-QAM
Code rate
½
2/3
¾
5/6
7/8
½
2/3
¾
5/6
7/8
½
2/3
¾
5/6
7/8
1/4
4,354
5,806
6,532
7,257
7,620
8,709
11,612
13,063
14,515
15,240
13,063
17,418
19,595
21,772
22,861
Guard interval
1/8
1/16
4,838
5,123
6,451
6,830
7,257
7,684
8,064
8,538
8,467
8,965
9,676
10,246
12,902
13,661
14,515
15,369
16,127
17,076
16,934
17,930
14,515
15,369
19,353
20,491
21,772
23,053
24,191
25,614
25,401
26,895
1/32
5,278
7,037
7,917
8,797
9,237
10,556
14,075
15,834
17,594
18,473
15,834
21,112
23,751
26,390
27,710
Table 2-2 Available data rate for 7MHz DVB-T
In Table 2-3 the maximum useful bit rates are indicated for all valid transmission modes in a
6 MHz system.
Modulation
QPSK
16-QAM
64-QAM
Code rate
½
2/3
¾
5/6
7/8
½
2/3
¾
5/6
7/8
½
2/3
¾
5/6
7/8
1/4
3,732
4,976
5,599
6,221
6,532
7,465
9,953
11,197
12,441
13,063
11,197
14,929
16,796
18,662
19,595
Guard interval
1/8
1/16
4,147
4,391
5,529
5,855
6,221
6,587
6,912
7,318
7,257
7,684
8,294
8,782
11,059
11,709
12,441
13,173
13,824
14,637
14,515
15,369
12,441
13,173
16,588
17,564
18,662
19,760
20,735
21,955
21,772
23,053
1/32
4,524
6,032
6,786
7,540
7,917
9,048
12,064
13,572
15,080
15,834
13,572
18,096
20,358
22,620
23,751
Table 2-3 Available data rate for 6MHz DVB-T
With 204 byte packet input the maximum bit rates are increased accordingly.
Instruction Manual
Revision 3.11
2-5
Introduction and Applications
ProTelevision Technologies
PT 5780 DVB-T Modulator
With Multi Frequency Network operation (MFN) the built-in Transport Stream Adapter (TSA)
performs the function of discarding any stuffing present on the input stream, inserting new
stuffing (0-packets) to adjust the bit rate and finally recalculating the PCR values of the MPEG2
transport stream. Thus the modulator will accept any transport stream with a useful bit rate
lower than the maximum indicated in the table.
When operating in the single frequency network mode, the bit rate must be exact. The applied
transport stream must furthermore include valid MIP information.
2.4
Alarm Circuits
Two independent alarm circuits are provided. Each circuit may be “armed” for a number of
conditions important for correct operation. Alarm output is via floating contacts on the rear panel
as well as via the remote control. A red LED on the front panel indicates an existing alarm
condition while the display will show the nature of the alarm.
2.5
Operation
The DVB-T Modulator may be configured and operated from either the front panel or via the
remote control port. The front panel control is implemented as a menu system. The status or
configuration menu of interest is displayed on a 2-line LCD display. Navigation between the
menus is done by means of a set of cursor keys (UP, DOWN, LEFT, RIGHT and an EXECUTE
key). To facilitate the remote control of several transmitters each modulator may be individually
named (16 characters). This “name” appears on the front panel display and is available on the
remote port.
Also the modulator may be controlled by data embedded in the incoming MPEG transport
stream itself. If this mode is enabled, it will have highest priority and other controls will be
inhibited. Note this will be the normal mode of operation in a Single Frequency Network (SFN).
When not assisting in configuration or mode selection, the front panel display will show the
status and operational modes of the modulator. In case of an alarm the nature of the cause of
the alarm will be shown.
All settings are always saved in an internal non-volatile storage. This means that the last saved
configuration will automatically be recalled at power on.
2.6
Frequency References
The modulator is equipped with an internal frequency reference with stability of ±
1ppm,adequate for many applications including multi frequency applications. Where higher
accuracies are required, an external 10 MHz frequency reference input is provided.
In Single Frequency Networks (SFN) this input must be connected to an external 10 MHz
reference typically obtained via GPS. In SFN mode the separate 1 pulse per second reference
input must also be connected to the special 1 PPS output of the GPS reference.
Instruction Manual
Revision 3.11
2-6
PT 5780 DVB-T Modulator
2.7
ProTelevision Technologies
Introduction and Applications
Test Facilities
The DVB-T Modulator PT 5780 features a range of useful test signal for both off-line and on-line
testing.
Single carrier:
The single carrier test signal is an off-line test signal (i.e. it interrupts the modulators data
transmission). When the single carrier test signal is activated the normal DVB-T spectrum is
substitutes for a single continuous sine wave located at the centre frequency of the normal inservice DVB-T spectrum. The RMS level of the sine equals the average RMS level in the full
bandwidth of the normal DVB-T spectrum. The signal is therefore excellent for adjusting
transmitter level and/or verifying frequency accuracy or phase noise performance for the
modulator output.
-1 Carrier test signal
For special tests any single one of the carriers in the DVB-T spectrum can be switched off. This
test signal is in principle an off-line test signal. However, as the FEC of the COFDM coding will
normally cope with the loss of a single carrier without difficulty the signal can be activated during
normal transmission with marginal influence to the performance (slight increase in BER may be
noticed).
-50 Carrier test signal
To allow analysis of in-band intermodulation in a transmitter system 50 consecutive carriers in
the DVB-T spectrum can be switched off. The location of the 50-carrier hole can freely be
selected but typically the hole is placed at the centre of the spectrum. It is recommended to use
this test signal only for off-line tests. However, in most cases the transmission service is
maintained despite the loss of 50 carriers thanks to the FEC of the COFDM coding.
TS Stuffing
This test signal facilitates testing of a transmission systems IF and/or RF parameters even when
no MPEG-2 input is available (MFN mode only). When the TS Stuffing signal is activated a
pseudo random bit sequence as described in section 9.16.1 of the DVB-T Measurement
Guidelines ETR 290 is transmitted.
Instruction Manual
Revision 3.11
2-7
Introduction and Applications
ProTelevision Technologies
PT 5780 DVB-T Modulator
This page is intentionally left blank
Instruction Manual
Revision 3.11
2-8
PT 5780 DVB-T Modulator
Installation
3.1
Initial Inspection
ProTelevision Technologies
Installation
Check the contents of the shipment for completeness and possible transport damage. If the
contents are incomplete or damaged, a claim should be filed with the carrier immediately, and
the ProTelevision Help Desk should be notified in order to facilitate the repair or replacement of
the instrument.
3.2
Safety Instruction
3.2.1
Earthing
Before any other connection is made, the instrument must be connected to a protective earth
conductor in one of the following ways: via the three-core mains cable via the protective earth
terminal marked.
Before connecting the equipment to the mains of the building installation, the proper functioning
of the protective earth lead of the building installation needs to be verified.
Warning: Any interruption of the protective conductor inside or outside the instrument, or
disconnection of the protective earth terminal, is likely to make the instrument dangerous.
Intentional interruption is prohibited.
3.3
Mains Voltage Cord and Fuses
Different power cords are available for the various voltage outlets.
Note:
If the mains plug has to be adapted for local use, only a qualified person should carry out this
task.
This instrument is equipped with a tap-less switch mode power supply that covers most nominal
voltage ranges in use: 90-132 VAC RMS / 180-250 VAC RMS. This obviates the need to adapt
to the local mains voltage.
The mains frequency is 48-65 Hz.
Warning: This instrument shall be disconnected from all voltage sources when renewing a fuse.
Mains fuse rating: 2 pcs. 1.25A slow blow, 250 V.
The mains fuse-holder is located on the rear panel of the instrument.
If the mains fuse has to be replaced please proceed as follows:
1. Remove the mains cable.
2. Lift the plastic cover (fuse-holder) by means of a small screwdriver.
3. Insert the new fuse into the top of the fuse-holder.
4. Re-insert the cover (fuse-holder).
Instruction Manual
Revision 3.11
3-1
Installation
ProTelevision Technologies
PT 5780 DVB-T Modulator
Warning: Make sure that only fuses of the required rating, voltage, and of the specified type are
used for replacement. The use of repaired (jumpered) fuses and/or the short-circuiting of the
fuse holder are prohibited. Fuses must only be replaced by a qualified person who is aware of
the hazards involved.
3.4
Rack Mounting
This instrument is delivered in a 19" cabinet. Four self-adhesive rubber feet are supplied
together with this instrument.
If several cabinets are mounted in a 19" rack, special attention must be paid to the temperature
inside the rack.
The DVB-T modulator is equipped with cooling fans and air inlets on the side of the cabinet.
Note: The operation of the fan is temperature controlled.
If the DVB-T Modulator is mounted between other instruments with high surface temperature,
this cooling may not be sufficient. Under these circumstances, it is recommended to make
space between the instruments, and to establish forced circulation (cooling) in the rack.
3.5
Cleaning
- Disconnect the instrument from the mains voltage supply before cleaning
- Use only a damp cloth
- Make sure that no liquid is spilled inside the instrument
Instruction Manual
Revision 3.11
3-2
PT 5780 DVB-T Modulator
ProTelevision Technologies
Installation
3.6
Configuration
3.6.1
Wiring schemes for RS 232 (handshake not implemented)
PT 5780
PC controller
RxD / TxD
TxD / RxD
DTR / DSR *
GND / GND
DSR / DTR*
RTS / CTS*
CTS / RTS*
9 pins
*:Not implemented
PT 5780
9 pins
PC controller
RxD / TxD
TxD / RxD
DTR / DSR*
GND / GND
DSR / DTR*
RTS / CTS*
CTS / RTS*
9 pins
3.6.2
*: Not implemented
20
25 pins
Alarms
Wiring of ALARM CONNECTIONS
Alarm 1
Alarm 2
Mute GND MR
Note: Contact ratings 60V, 0.2A max. 5W load.
Instruction Manual
Revision 3.11
3-3
Installation
3.6.3
ProTelevision Technologies
PT 5780 DVB-T Modulator
Mute
The modulator output can be forced to the muted state by establishing a connection between pin 7 and 8 of
the Alarm connector (see paragraph 3.6.2 above).
3.6.4
Reset
The modulator can be reset by briefly establishing a connection between pin 7 and 9 of the Alarm connector
(see paragraph 3.6.2 above).
3.7
Access to and Replacement of Parts
3.7.1
Safety
Warranty will be void if any person without specific authorisation from ProTelevision
Technologies opens the modulator chassis.
The opening of covers or removal of parts, except those to which access can be gained by
hand, is liable to expose live parts.
The instrument must be disconnected from all voltage sources before performing any
adjustment, replacement, maintenance, or repair, which requires the instrument to be opened. If
repair of the opened instrument is unavoidable, it must only be carried out by a skilled person,
who is aware of the hazards involved. To guarantee safety only original spare parts must be
used.
3.7.2
Access to the Units
Warranty will be void if any person without specific authorisation from ProTelevision
Technologies opens the modulator chassis.
To gain access to the units, remove the screws that secure the top cover of the instrument and
lift the cover up.
Instruction Manual
Revision 3.11
3-4
PT 5780 DVB-T Modulator
ProTelevision Technologies
Operating Instructions
4.1
Front Panel
Operating Instructions
All operational control and configuration are conveniently carried out from the front panel.
The two line by forty characters LCD display, in conjunction with four cursor keys and an
EXECUTE button, allows easy operation of the PT 5780 DVB-T Modulator.
The display is used to indicate the status of various system parameters and also allows
changes to be made to these system parameters.
The cursor keys and EXECUTE button are used to navigate through the menu system and to
configure system parameters.
Front of the Instrument
4.1.1
Front Panel Indicators
Green POWER ON LED
When lit up, the green LED indicates that power is available from the supply.
Red ALARMS LED
This LED indicates the presence of an irregularity when any of the alarm conditions (e.g. “Sync
Loss”, “Reference Loss”, etc) are “active” AND they have been configured to output to one of
the relays. See Chapter 4.3.4.5 Alarm menu system for more details.
In addition this LED may flash. This occurs when there is a test signal active.
Red UNLOCKED LED
When lit up, the red LED indicates failure of the modulator in synchronizing to the incoming
transport stream or external frequency reference signal.
Note that the Alarm & Unlocked LEDs flash when the DVB-T modulator output is muted. Note
that the output in SFN mode will mute irrespective of the general programming of mute
conditions until the modulator have established synchronising to the timing references (1PPS,
10MHz and MIP).
4.1.2
Front Panel Controls (The menu system)
For cursor buttons and an execute button plus an LCD display are available for front panel
control of the DVB-T Modulator. The front panel functions are divided between read-out of
status information (transmission mode, output frequency, alarm status, etc.) and actual
setting/change of parameters that will affect the modulator output. To navigate between the two
functionalities (status and configuration) please refer to the drawing in figure 4-1
Instruction Manual
Revision 3.11
4-1
Operating Instructions
ProTelevision Technologies
PT 5780 DVB-T Modulator
Status Menu System
Push [EXECUTE] button
Push [UP ARROW] button
and [RIGHT ARROW] button
to return to the Status Menu
in sequence to enter the
System.
Configuration Menu System
Rev 3.0 23.01.2003
Configuration Menu System
u/5780/work/manual v3/drawings/status and config system
(note 1).
Note 1: Activates the Configuration Menu System at the top-level default entry point (Menu ID 1000 - ). Alternatively, by pushing
the [EXECUTE] key twice the Configuration Menu System will be activated at a sub menu relevant to the currently selected status display. For
example, pushing [EXECUTE] twice when the Input Status display is active will open the configuration sub menu for control of input configuration
Figure 4-1 Front panel menu system
Dependent on the specific function being operated via the front panel the cursor keys may have
the following functions:
The 5 button is used to either
•
Scroll through the different sub displays provided within the status menu system (refer to
the enclosed Status Menu System diagram)
• Exit the current menu and enter a higher-level menu
• Increase alpha-numerical parameters
• Abort confirmation of a change
The 6 button is used to either
•
Scroll through the different sub displays provided within in the status menu system (refer
to the enclosed Status Menu System diagram).
• Exit the current menu and enter a sub-menu
• Decrease alpha-numerical parameters
• Abort confirmation of a change
The 3 and 4 buttons are used to scroll between the main displays provided in the status menu
system (refer to the enclosed Status Menu System diagram) and to scroll between the functions
available in the configuration menu system.
Instruction Manual
Revision 3.11
4-2
PT 5780 DVB-T Modulator
ProTelevision Technologies
Operating Instructions
The EXECUTE button is used to
• Enter the configuration menu system (GENERAL or SPECIFIC) when in the status menu
system.
• Confirm changes made to configurable parameters.
4.1.3
Front Panel Display
To guide the user through operations, symbols of the push buttons, which are active at that
particular time appear in the top right hand side of the display.
3and 4indicate that the left and right arrow buttons can be used; a 5indicates that the up
button can be used; a 6 indicates that the down button can be used; a v indicates that both
the up and down buttons can be used; and an E indicates that the EXECUTE button can be
used.
5634
Indicates which arrow buttons are active.
Indicates that the EXECUTE button must be pressed to activate the required
selection.
<>
These flashing brackets indicate the position of the cursor when in a menu
option listing, also described as the “current” menu option in this manual.
[]
These flashing brackets indicate the position of the cursor when in a
enumerated parameter listing or when in a parameter set listing. Also
described as the “current” parameter in this manual.
…
Indicates that more items are available in the menu option or parameter listing
than can be fitted in the display. Scrolling right with the 4 button will display
these items.
Guide to Menu Display
In addition, the top line of the display also usually shows the current menu option and status.
The bottom line of the display indicates possible menu options or parameter settings.
4.2
Rear Panel
4.2.1
Rear Panel Connections
Safety Ground (chassis)
Instruction Manual
Revision 3.11
4-3
Operating Instructions
ProTelevision Technologies
PT 5780 DVB-T Modulator
Mains Connector
Mains voltage receptacle with ON/OFF switch.
ON:
When “I” is pressed.
OFF:
When “O” is pressed.
Input Connectors A and B
Two BNC inputs (A and B) are provided for asynchronous serial transport streams (ASI).
Remote Connectors 1 and 2
Two 9 pole male Sub-D connectors are utilised for the remote connectors. They are configured
as RS 232 connections. For configuration of these connectors refer to the CONFIGURE menu
system in Chapter 4.3.4.7.
Monitor Output Connector
A BNC connector (ASI format ) is provided for output monitoring purposes.
Alarms Connector
A 9 pole male sub-D connector of floating-contact type is provided to connect the two alarm
switches to external alarm indicators. The connector also includes contact points for groundclosure activated output muting and instrument reset. For connections, refer to the Installation
chapter of this manual. For configuration of alarms, refer to Chapter 4.3.4.5 Alarm menu
system.
Reference Inputs
1 PPS - A BNC connector is provided for a 1 pulse per second input signal for SFN
synchronization.
10 MHz - A BNC connector is provided for an external frequency reference input of 10 MHz.
IF Output
A BNC connector (with a 50
impedance) is provided for the IF output signal.
IF/RF Output A
An N-type connector (with a 50
impedance) is provided for the main IFR/RF OFDM output.
IF/RF Output B
An N-type connector is also provided for an optional IF/RF output signal.
MAINS
FUSE 2x 1.25A SLOW BLOW
REMOTE 2
IF/RF OUTPUTS
IF/RF
INPUT
IF
OUTPUT
1PPS
10MHZ
REF. INPUTS
ALARMS
REMOTE 1
MONITOR
OUTPUT
ASI
IEEE 1394
INPUT B
ASI
IEEE 1394
INPUT A
CE
ETHERNET
Rear of the Instrument
When monitoring the internally processed MPEG-2 streams (Demodulator output or the TSA
adapted input) the clocking out of the useful data takes place during the actual COFDM symbol
– no data is clocked out during the COFDM signals guard interval (the data stream is therefore
of a bursty nature)
Instruction Manual
Revision 3.11
4-4
PT 5780 DVB-T Modulator
4.3
ProTelevision Technologies
Operating Instructions
Menu System – Description and Operation
The PT 5780 DVB-T Modulator is equipped with different functions dependent on the purchased
options.
An operating menu chart, which reflects the structure of the menu system when all possible
functions are installed and enabled, is provided in appendix A..
The menu system is designed as a “tree” structure, with a number of different “branches”. Each
“branch” is made up of a “menu options”. The lowest “branch” contains a configurable menu
option with a list of parameters to choose from.
Note that additional configurable options are available via remote access/control. See Chapter
6.2.3.
The menu system has two main functions:1. system status display - the display of various modulator configuration settings through
“status windows”
2. system configuration - the ability to modify the modulator’s configuration settings through
“configuration windows”.
On start up the modulator always enters the system status menu.
There are two ways to enter the configuration menu system; by pressing [EXECUTE] followed
by the [RIGHT] arrow button the configuration system will be opened at the top level entry point
and the user will be able to navigate freely between all the menus. Alternatively, the user can
press [EXECUTE] twice to open the menu system at a sub menu relevant to the status menu
parameters being displayed when the key-press sequence is initiated. When using this
navigation method pressing the [UP] arrow key will recall the last status display.
4.3.1
Power Up
The start-up process includes the following status
windows:
----------------------------------------
This text is a site specific
identification and can be modified by
the customer via the Remote
Interface only.
PT5780 DVB-T Modulator
PTV
- Power-up 2001-07-08, 3:07:33
----------------------------------------
The current date and time is
displayed until the back-end controller
is powered up.
And later:
---------------------------------------PT5780 DVB-T Modulator
PTV
Release X.X ............................
----------------------------------------
Instruction Manual
Revision 3.11
The software release is momentarily
displayed before the modulator enters
the first status window.
4-5
Operating Instructions
ProTelevision Technologies
In case new micro-code has to be installed, the
following is displayed:
---------------------------------------****
R E C O N F I G U R I N G
****
=micro-code being installed
-=
----------------------------------------
PT 5780 DVB-T Modulator
The first line will flash. After new
micro-code has been
downloaded, the system
automatically reboots.
Following successful start-up, the first status display window appears – see Chapter 4.3.3.1.
Switching the instrument off and then back on again retains all system configuration settings.
4.3.2
Operating Menu System Chart
A set of charts describing the menu system is provided (see appendix A) in order to
diagrammatically show the structure of the menu system, with the various menu options and
parameters. The charts enclosed are:
• Status Menu System
• Configuration Menu System (page 1 of 2)
• Configuration Menu System (page 2 of 2)
All menu windows in the menu system contain a four-digit number in the top right hand position.
This number is known as the menu identification number and is useful for referencing and
navigating purposes and is shown in “red” in the Menu System Charts. The menu-structure has
a maximum of four levels; hence the four-digit identification.
4.3.3
Status Menu System
If all hardware/software options are installed, enabled and turned on, the system status menu
consists of a maximum of eight main “status windows”. Each main “status window” can be
divided into a number of sub windows. The “status windows” display the settings of various
configurable options and system variables.
A description of each status window is provided below. Each status window is identified with a
flashing character (’a-n’ through to ’h-n’) in the lower right hand corner of the display (n is an
integer decimal value 1, 2, 3,… that identifies the specific sub window). These status window
identification characters flash at approximately 1 Hz to indicate that the device is running. If
preferred, the status display identifiers can be removed from the display altogether or left as a
constant display by using the CONFIGURE – STATUS MENU ID menu option. Chapter 4.3.4.7
describes how to configure this Menu ID.
As mentioned previously, certain status windows are only accessible if the appropriate
hardware/software options are installed.
The operator may navigate through the main status windows by using the left or right cursor
keys. Navigation between sub status windows is where applicable done by means of the up or
down arrow keys. On reaching the last or first status window the system loops round to the first
and last respectively.
The information in the status display windows are updated approximately every ½sec.
Instruction Manual
Revision 3.11
4-6
PT 5780 DVB-T Modulator
4.3.3.1
ProTelevision Technologies
Operating Instructions
Description of Status Display Windows
Status Window ‘a1’ – The Input (or High Priority Input in the case of a hierarchical
system) Status Window
The example given here is for a hierarchical system:
---------------------------------------INPUT HP: A ASI / 204 OK
wv8E
Ref:Ext
a1
---------------------------------------Status Window ‘a2’ – The Low Priority Input Status Window
This window is only available when the hierarchical version of the modulator is in use. However
if the hierarchical mode is set to “NONE” through the menu TRANSMISSION – MODE –
HIERARCHICAL MODE, the following window is displayed, as there has been no hierarchical
alpha parameter configured:
---------------------------------------INPUT LP: Non Hierarchical Mode wv8E
Ref: Int
a2
---------------------------------------However if the hierarchical alpha parameter is set to one of the hierarchical modes (alpha 1,
alpha 2 or alpha 4), the following window is displayed (assuming that input B has been selected
as LP source):
---------------------------------------INPUT LP: B ASI / 204 OK
wv8E
Ref:Int
a2
---------------------------------------The Input status windows show the data packet size, the input signal type and the source of the
10MHz system reference clock (Internal or External)
Status Window ‘a1’ – Signal loss vs. Auto Substitute function
When the modulator cannot detect an input signal and the auto substitute function is disabled,
the following input status window appears (assuming that input A signal source is lost in nonhierarchical mode):
---------------------------------------INPUT :
A ASI No Sync
wv8E
Ref:Int
a1
---------------------------------------Note: “No Sync” flashes.
If the input specified as primary source in non-hierarchical mode is lost when the auto substitute
function is enabled, the following input status window appears (assuming that the input
specified as secondary source (B) is available):
---------------------------------------INPUT
Prim: A ASI No Sync
wv8E
Ref:Int Sec: B ASI /204 OK
à
Source Exif Data:
File Type : PDF
File Type Extension : pdf
MIME Type : application/pdf
PDF Version : 1.3
Linearized : No
Encryption : Standard V1.2 (40-bit)
User Access : Print, Fill forms, Extract, Assemble, Print high-res
Creator : Microsoft Word
Create Date : 2003:08:25 10:06:15
Title : rev.3.11.doc
Author : hso
Producer : Acrobat PDFWriter 4.0 for Windows
Modify Date : 2003:08:25 10:13:28+02:00
Page Count : 95