UTC Fire and Security Americas 786A-DTIM Telephone Interface Module User Manual

UTC Fire & Security Americas Corporation, Inc. Telephone Interface Module

Contents

User manual

Download: UTC Fire and Security Americas 786A-DTIM Telephone Interface Module User Manual
Mirror Download [FCC.gov]UTC Fire and Security Americas 786A-DTIM Telephone Interface Module User Manual
Document ID225698
Application IDHzSD4sGorxJPjsxiJUt/aA==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize8.02kB (100255 bits)
Date Submitted2002-02-11 00:00:00
Date Available2002-05-07 00:00:00
Creation Date2002-02-11 08:02:10
Producing SoftwareAcrobat Distiller 4.05 for Windows
Document Lastmod2002-02-11 08:02:11
Document TitleUser manual

Preliminary 2/11/02
ITI Part No. 60-879-95R
'LDORJŒ7HOHSKRQH
,QWHUIDFH0RGXOH
Document Number: 466-1849 Rev. A
February 2002
Installation Instructions
Product Summary
The Dialog Telephone Interface Module (DTIM) is a battery operated communication link between the security system control panel and the central monitoring station. The
DTIM provides added security by separating the telephone
interface from the panel. If the panel is damaged during a
break-in or fire, the DTIM can still report to the central
monitoring station.
The DTIM receives radio signals from the panel, then uses
the phone line to report security system events to the central
monitoring station.
The DTIM is a supervised device that transmits supervisory
signals every hour for the panel to receive. When the battery
is low, the module transmits a low battery signal.
Note
The DTIM does not have a backup power supply. Therefore, the battery must be replaced immediately when a
low battery condition occurs to ensure that system events
can be reported. If the battery is allowed to completely
drain, the panel identifies the DTIM as being in a supervisory (non-working) state, which prevents system events
from being reported.
Installation Guidelines
❑
provides customers with a quick disconnect in case the
DTIM malfunctions, allowing them to use their phone.
For UL Listed installations, mount the RJ-31X jack
within 5 feet of the DTIM.
Tools Needed
❑
❑
❑
❑
Phillips screwdriver
Two #6 phillips-head screws (included)
Two wall anchors (included)
Pencil
Installation
This section describes programming, testing, mounting, and
phone line connections.
Programming—Adding the DTIM to Panel
Memory
This section describes the steps for adding (learning) the
DTIM into panel memory, which requires a series of module tamper switch activations and module LED responses
(see Figure 1).
Use the following guidelines when installing the DTIM.
❑
❑
❑
❑
Before permanently mounting to a wall, test the DTIM
from the desired location to ensure communication
with the panel. This means you must first add (learn)
the DTIM into panel memory, then perform a sensor
test.
Mount the module within 100 feet of the panel, but not
closer than 10 feet to another DTIM or the panel.
Always mount the DTIM in the upright vertical position.
The DTIM can be connected to a standard analog
(loop-start) phone line, with or without digital subscriber line (DSL) service.
Note
The DTIM cannot be used on digital or PBX phone lines,
which are designed only for digital type devices that operate anywhere from 5 volts DC and up. The DTIM uses an
analog modem and does not have a digital converter,
adapter, or interface to operate with such systems.
❑
Tamper
Switch
LED
T IP
L O C A L
T IP
L O C A L
R IN G
R IN G
Figure 1. Tamper Switch and LED Locations
The DTIM uses a 3-2-1 tamper switch activation sequence
for learning, which causes the LED to blink in a corresponding 3-2-1 sequence. You must wait for the LED to
turn off after each flash sequence before releasing the
tamper switch.
Note
The DTIM should be learned into panel memory as zone
1.
When connecting the DTIM to a standard analog phone
line, it is recommended that you install an RJ-31X jack
(CA-38A in Canada) ahead of all phones and other
devices on the line for full line seizure. This allows the
DTIM to take control of the phone line when an alarm
occurs, even if the phone is in use or off-hook. It also
Preliminary 2/11/02
To learn the DTIM into the panel:
5.
If you hear fewer than 7 beeps, test the DTIM in different locations. Mounting locations should be limited to
areas where the panel responds with 7 - 8 beeps.
6.
To retest transmitting range after relocating the DTIM,
press ‚ then ƒ and listen for 7 - 8 beeps.
7.
Exit from test mode after determining acceptable locations.
Important !
Timing is the key to success with this procedure. Do not
wait more than 1-2 seconds between steps 4 and 5 or
steps 5 and 6 after releasing the tamper switch. If you
wait too long between these steps, the LED will not flash
and you will have to start over. Also, do not release the
tamper switch before the LED is done flashing or you will
have to start over.
1.
Remove the DTIM cover and set it aside (see Figure 2).
Mounting/Receiving Antenna Positioning
After finding an acceptable mounting location (based on
testing), mount the DTIM and position the antenna as
described. The antenna can be inserted into a wall or positioned upright inside the antenna housing.
Note
For best range, it is recommended to insert the antenna
into the wall.
Mounting with Receiving Antenna in Wall
&$87,21
You must be free of static electricity before handling
circuit boards. Touch a bare metal surface or wear a
grounding strap to discharge yourself.
Push Tab Up
Lift Cover Up
1.
Figure 2. Removing the Cover
2.
3.
With the system disarmed, enter program mode by
pressing 8 + CODE.
Press
ZONE
twice and ƒ twice. The display shows
01 - TRIP.
4.
Press the DTIM tamper switch three times, holding the
tamper switch down on the third press and wait for the
the LED to flash 3 times, then release the tamper
switch after the third flash.
5.
Press the DTIM tamper switch twice, holding the
tamper switch down on the second press and wait for
the LED to flash two times, then release the tamper
switch after the second flash.
6.
Press and hold the tamper switch down until the LED
flashes once, then release the tamper switch after the
flash. The panel beeps twice and the display shows the
next available sensor number.
7.
Exit from program mode.
Testing
This section describes the basic steps for testing transmitting range from the DTIM to the panel. For complete testing
instructions, see the panel installation instructions.
Note
Be sure to attach the cover onto the DTIM before testing
wireless communications.
1.
Straighten the antenna to a vertical position.
2.
Place the DTIM in the desired location.
3.
Put the panel into sensor test mode.
4.
Listen for the panel piezo to sound 7 - 8 beeps. This
indicates good reception from the DTIM to the panel.
Remove the circuit board from the plastic housing by
pushing up on the tab and pulling the board outward
(see A in Figure 3). Place the board in the cover.
Receiving
Antenna
Mounting
Hole
Tab
T IP
L O C A L
T IP
L O C A L
R IN G
R IN G
Antenna
Insertion
Hole
Mounting
Hole
Figure 3. Removing the Circuit Board to Mark Mounting and Antenna Holes
2.
Mark the mounting holes and the antenna insertion hole
(see B in Figure 3).
3.
Make holes in the wall for anchors at the marked locations.
4.
Insert wall anchors where necessary, then use two #6
screws to secure the plastic housing to the wall.
5.
Insert the antenna into the antenna insertion hole and
re-install the board onto the plastic base, bottom first
then push in at the top until it snaps in under the tab.
6.
Install the protective dust cap (included in accessory
packet) in the hole located on the top-right of the DTIM
plastic housing.
Preliminary 2/11/02
Mounting with Antenna Housing
1.
3.
Disconnect the Green and Red premises phone jack
wires from the TELCO block and splice them to the 4conductor cable Black and White (or Yellow) wires (C
in Figure 5). Use weatherproof wire connectors for
these splices.
4.
Connect the 4-conductor cable Green and Red wires to
the TELCO block TIP (+) and Red to RING (-) posts
(D in Figure 5).
5.
Connect the DB-8 cord (not included) to the RJ-31X
and the DTIM terminals (E in Figure 5).
Hold the DTIM against the wall and mark the mounting
holes (see A in Figure 4). Be sure to leave at least 4
inches above the DTIM for the antenna housing.
Antenna
Housing
Mounting
Hole
Receiving
Antenna
R IN G
T IP
L O C A L
T IP
L O C A L
R IN G
R IN G
Mounting
Hole
L O C A L
R IN G
R IN G
Red
L O C A L
R IN G
L O C A L
T IP
Gray
L O C A L
T IP
T IP
Green
T IP
Brown
Figure 4. Mounting Hole Locations and Antenna Housing Installation
2.
Slide the antenna housing over the antenna and snap
the housing into the upper-right hole (see B in Figure
4).
3.
Make holes in the wall for anchors at the marked locations, then insert wall anchors where necessary and
secure the module to the wall using two #6 screws.
GRY
BRN
Wiring a Phone Line to the Module
Basically, there are two methods for connecting the DTIM
to a phone line; full line seizure and no line seizure.
An RJ-31X (CA-38A) jack should be installed when wiring
for full line seizure. This lets the user quickly and easily disconnect the DTIM from the phone line in case the DTIM
disables the phone line due to a malfunction.
Full Line Seizure Wiring with an RJ-31X
Note
For UL Listed systems, the RJ-31X jack must be
mounted within 5 feet of the DTIM.
1.
Run a 4-conductor cable from the TELCO block to the
RJ-31X (A in Figure 5).
2.
Connect the 4-conductor cable wires to the RJ-31X (B
in Figure 5).
Red
Green
Black
This method requires that the DTIM be wired ahead (or in
front) of all other phones, answering machines, computers,
or any other devices on the phone line. This allows the
DTIM to take over (seize) the phone line, even if another
device on the line is in use.
White
(or Yellow)
RED
GRN
Full Line Seizure
TIP
(+)
RING
(-)
Green
Red
Black
White (or Yellow)
Green
Red
Premises
Phone Jack
Wires
Figure 5. Full Line Seizure Wiring with an RJ-31X
Preliminary 2/11/02
No Line Seizure
Constant Dial Tone
This method is typically used where DSL (digital subscriber
line) service exists. DSL allows multiple devices on a single
phone line to be used simultaneously. Simply connecting a
standard phone cord to an available phone jack on the premises is all that is required. An in-line filter may be required
to ensure panel reporting is successful (see Figure 6).
❑
No System Response
Note
Connecting the DTIM to a standard phone (voice) line
without DSL service in this manner should be avoided.
Other devices in use at the same time the DTIM is using
the line can prevent reports from going through.
If the system does not respond in sensor test (as described in
the panel installation instructions), try the following:
❑
❑
❑
❑
❑
❑
R IN G
Red
L O C A L
R IN G
Green
L O C A L
T IP
Change the antenna position. Best range is achieved by
inserting the antenna into the wall.
Check that the DTIM battery is installed.
Check the DTIM battery for low voltage. Replace the
battery if necessary.
Use an RF Sniffer (60-401) to verify that the DTIM is
transmitting.
Verify that the DTIM was added (learned) into panel
memory correctly.
Trouble Condition
T IP
If a constant dial tone prevents you from using the
phone, there may be one or more polarity-sensitive
phones on the premises. Reverse the phone wires connected to the brown and gray wire terminals on the RJ31X jack.
❑
The tamper switch may have been tripped. Check that
the cover is securely in place.
The DTIM battery may be low. Check the battery and
replace if necessary.
Module Supervisory
❑
DSL In-Line
Filter
Premises
Phone Jack
Figure 6. No Line Seizure with DSL Service
Troubleshooting
No Dial Tone
If there is no dial tone at on-site phones after wiring the RJ31X jack, use the following to find the cause.
❑
❑
❑
❑
Wait 2 minutes and try again. The DTIM may be busy
trying to report to the central station.
Check the DB-8 cord connections at the module and
RJ-31X jack. Replace the cord if necessary.
Disconnect the DB-8 cord from the RJ-31X jack. If the
phone still doesn’t work, the problem is in the RJ-31X
jack wiring. Check the RJ-31X jack wiring and
TELCO block wiring. Replace the RJ-31X jack if necessary.
Perform a phone test after troubleshooting the phone line
(see your panel installation instructions for phone test
procedures).
❑
If the panel indicates a DTIM supervisory condition,
use an RF Sniffer (60-401) to verify that the DTIM
transmits when the tamper switch is pressed. If it does
not transmit, check the battery and replace it if necessary.
If the sniffer indicates that the DTIM is transmitting, it
may be out of panel receiving range. Use the sensor test
to verify that the DTIM is within panel range. If necessary, test the DTIM from other locations until an
acceptable location is found.
Specifications
Compatibility: .............. Allegro™
Wireless Range ............. 500 feet open-air (nominal)
Power Source: .............. 3.6 V AA Lithium Battery
Storage Temperature:.... -30° F to 140° F (-34° C to 60° C)
Operating Temperature: 32° F to 120° F(0° C to 49° C)
Maximum Humidity: ... 90% relative humidity, noncondensing
Dimensions: ................. W = 4.6 inches (11.7 cm) x D = 1.2
inches (3.0 cm) x H = 6.6 inches
(16.8 cm) plus 3.5 inches (8.9 cm)
for antenna housing
Preliminary 2/11/02
Notices
FCC Part 15 Information to the User
Changes or modifications not expressly approved by Interlogix, Inc. can
void the user’s authority to operate the equipment.
FCC Part 15 Class B
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of
the following measures:
❑ Reorient or relocate the receiving antenna.
❑ Increase the separation between the equipment and receiver.
❑ Connect the affected equipment and the panel receiver to separate
outlets, on different branch circuits.
❑ Consult the dealer or an experienced radio/TV technician for help.
FCC ID No. B4Z-786A-DTIM
FCC Part 68
This equipment complies with Part 68 of the FCC Rules. Located on this
equipment is a label that contains, among other information, the FCC registration number and the ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the telephone
company.
The REN is used to determine the maximum number of devices that may
be connected to your telephone line. In most areas, the sum of all device
RENs should not exceed five (5.0).
If this equipment causes harm to the telephone network, the telephone
company may temporarily disconnect your service. If possible, you will be
notified in advance. When advance notice is not practical, you will be notified as soon as possible. You will also be advised of your right to file a
complaint with the FCC.
Your telephone company may make changes in its facilities, equipment,
operations, or procedures that could affect the proper operation of your
equipment. You will be given advanced notice in order to maintain uninterrupted service.
If you experience trouble with this equipment, please contact:
ITI
2266 Second Street North
North Saint Paul, MN 55109
1-800-777-2624
This equipment may not be used on coin service provided by the telephone
company. Connection to party lines is subject to state tariffs.
Before installing this equipment, users should ensure that it is permissible
to be connected to the facilities of the local telecommunications company.
The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single-line individual service may be extended by means of a certified
connector assembly (telephone extension cord). The customer should be
aware that compliance with the above conditions may not prevent degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian
maintenance facility designated by the supplier. Any repairs or alterations
made by the user to this equipment, or equipment malfunctions, may give
the telecommunications company cause to request the user to disconnect
the equipment.
For your protection, make sure that the electrical ground connections of the
power utility, telephone lines, and internal metallic water pipe system, if
present, are connected together.
&$87,21
Do not attempt to make connections yourself. Contact
the appropriate electrician or electric inspections
authority.
The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop that is used by
the device to prevent overloading. The termination on a loop may consist
of any combination of devices subject only to the requirement that the total
of the LNs of all the devices does not exceed 100. Load Number: 0.2B AC
“AVIS: - L ´étiquette du ministère des Communications du Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est conforme a certaines normes de protection, d ´ exploitation et de sécurité des
réseaux de télécommunications. Le ministère n ´ assure toutefois pas que le
matériel fonctionnera a la satisfaction de l ´ utilisateur.
Avant d ´ installer ce matériel, l ´ utilisateur doit s ´ assurer qu´ il est permis
de le raccorder aux installations de l ´ enterprise locale de télécommunication. Le matériel doit également etre installé en suivant une méthod
acceptée de raccordement. Dans certains cas, les fils intérieurs de l´ enterprise utilisés pour un service individuel a ligne unique peuvent etre prolongés au moyen d´ un dispositif homologué de raccordement (cordon
prolongateur téléphonique interne). L ´ abonné ne doit pas oublier qu ´ il
est possible que la conformité aux conditions énoncées ci-dessus n ´
empechent pas le dégradation du service dans certaines situations. Actuellement, les enterprises de télécommunication ne permettent pas que l ´ on
raccorde leur matériel a des jacks d ´ abonné, sauf dans les cas précis prévus pas les tarrifs particuliers de ces enterprises.
Les réparations de matériel homologué doivent etre effectuées pas un centre d ´ entretien canadien autorisé désigné par le fournisseur. La compagne
de télécommunications peut demander a l ´ utilisateur de débrancher un
appareil a la suite de réparations ou de modifications effectuées par l ´ utilisateur ou a cause de mauvais fonctionnement.
Pour sa propre protection, l ´ utilisateur doit s ´ assurer que tous les fils de
mise a la terre de la source d ´ énergie électrique, des lignes téléphoniques
et des canalisations d ´´ eau métalliques, s ´ il y en a, sont raccordés ensemble. Cette précaution est particulièrement importante dans les régions
rurales.
Declaration of Conformity (DoC)
Avertissment. - L ´ utilisateur ne doit pas tenter de faire ces raccordements
lui-meme; il doit avoir recours a un service d ´ inspection des installations
électriques, ou a electricien, selon le cas”.
Interactive Technologies, Inc. declares that the ITI model no. 60-879-95R
is in conformity with Part 15 of the FCC Rules. Operation of this product is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Une note explicative sur les indices de charge (voir 1.6) et leur emploi, a l ´
intention des utilisateurs du matériel terminal, doit etre incluse dans l ´
information qui accompagne le materiel homologué. La note pourrait etre
rédigée selon le modèle suivant:
Canada Notice
The Canadian Department of Communications label identifies certified
equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements.
The department does not guarantee the equipment will operate to the user’s
satisfaction.
“L ´ indice de charge (IC) assigné a chaque dispositif terminal indique,
pour éviter toute surcharge, le pourcentage de la charge totale qui peut etre
raccordée a un circuit téléphonique bouclé utilisé par ce dispositif. La terminaison du circuit bouclé peut etre constituée de n ´ import somme des
indices de charge de l ´ ensemble des dispositifs ne dépasse pas 100.”
L ´ Indice de charge de cet produit est ____________.
Preliminary 2/11/02
22 6 6 Se co n d S t r e et N o r t h
No r t h S a in t Pa u l M n
55109
80 0 - 7 7 7- 26 2 4
w ww. it i i . co m
w w w. i n t er l o g i xs ec u r i t y. co m
©2002 Int er logi x,™ I nc. Int er lo gix and Alle gr o ar e tr ade mar ks of Int er logi x, Inc. IT I is a r egi ste re d t ra dema rk s of In te rl ogix , In c.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Create Date                     : 2002:02:11 08:02:10
Producer                        : Acrobat Distiller 4.05 for Windows
Modify Date                     : 2002:02:11 08:02:11-06:00
Page Count                      : 6
EXIF Metadata provided by EXIF.tools
FCC ID Filing: B4Z-786A-DTIM

Navigation menu