UTC Fire and Security Americas 788C-PIR Passive infrared Motion Detector User Manual

UTC Fire & Security Americas Corporation, Inc. Passive infrared Motion Detector

User Manual

Download: UTC Fire and Security Americas 788C-PIR Passive infrared Motion Detector User Manual
Mirror Download [FCC.gov]UTC Fire and Security Americas 788C-PIR Passive infrared Motion Detector User Manual
Document ID131459
Application IDWGFsZn+yMIJkSHcAv7TnlQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize23.7kB (296201 bits)
Date Submitted2001-01-05 00:00:00
Date Available2001-04-19 00:00:00
Creation Date2000-10-16 10:32:10
Producing SoftwareAcrobat Distiller 4.0 for Windows
Document Lastmod2000-10-16 10:32:14
Document TitleUser Manual

AP950W
Wireless PIR Detector
Installation Instructions
Base indent
Corner mounting holes
Mounting bracket
Flat wall
mounting
hole
Tamper
Actuator
Flat wall
mounting
hole
10 ft. max.
8.0 ft. nom.
7.0 ft. min.
8 ft.
25 ft.
50 ft.
Battery
holder
50 ft.
Main circuit
board
Figure 1
4.8 ft.
Figure 2
Description
The AP950W is a wireless low-current, passive infrared motion
detector that is highly sensitive to moving infrared sources. It
features superior immunity to RFI, vibration, static electricity,
temperature changes and other false alarm sources.
Selecting a Location
• Mount the sensor within 200 feet of the receiver unit.
• Mount the sensor on a rigid vibration-free surface.
• Mount the sensor 7 to 10 feet high.
• Mount the sensor so the expected movement of an intruder is
The detector provides switch selectable sensitivity and range and
allows optional masking to modify the coverage pattern for a wide
variety of applications.
across the fields of the detection pattern. See Figure 2.
• Do not locate the sensor in any area with an excessive
metallic surface.
• Do not locate the sensor on a surface exposed to moisture.
• Do not locate the sensor where it may be exposed to false alarm
sources such as: direct sunlight, heat sources (heater, radiators,
etc.) in the field of view, strong air drafts (fans, air conditioner, etc.)
on sensor.
• Do not locate the sensor where the ambient temperature is below
32° F or above 131°F.
Parts
The following parts are included with the detector:
·
·
·
·
·
•
•
PIR detector
Three 3V lithium batteries
Two plastic masks
One screw to secure the PIR unit to the wall mounting bracket
Wall mounting bracket
Sheet of adhesive masking labels
Removable undercrawl mask
Mounting the Detector
Verify the detector communicates with the control panel before you
permanently mount the detector. See Walk Testing the Detector.
Refer to Figure 1 as you perform the following steps:
1. Separate the PIR unit from the mounting bracket by pushing
apart the tabs at the bottom of the unit.
2. Select the appropriate knockout mounting holes on the
mounting bracket for either corner or flat wall mounting.
3. Use screws and wall anchors, if necessary, to attach the
mounting bracket to the wall.
1 2 3
5 6 7
8 9
Selecting the Coverage Pattern
The coverage pattern for the detector can be modified to fit specific
applications by masking off mirror curtains. Curtains should be
masked to avoid sources of false alarms, such as heaters, air
conditioners, and windows.
Open the unit by pressing the opening tab up. See Figure 6.
If necessary, use one or more of the following methods to modify
the coverage pattern:
Figure 5
Setting the Sensitivity and Range
Switches
The detector provides switches on the back of the detector for
setting sensitivityand range, as shown in Figure 6.
Use the following to determine the appropriate switch settings for
an application mode:
• BI= BI-curtain mode. Increases false alarm immunity in smaller
areas. Requires the intruder to pass through two curtains to trigger
an alarm. Do not use for single curtain applications or ranges under
5 feet. Factory default.
• STD= Standard mode. Use for wide angle or single-curtain
applications. Requires the intruder to only pass through one curtain
to trigger alarm.
• Range=Program switch for range under 33 ft. (factory default) or
to 50 ft. It's important to program the sensor correctly for optimum
sensitivity. Walk test the sensor regularly by walking across the
fields of view and checking that the LED lights and that the opening
relay is indicated back at the control panel.
· Use one or both of the plastic masks provided to mask off large
areas of coverage as shown in Figure 4.
· Mask the appropriate mirror curtains with the adhesive labels
provided. See the example shown in Figure 5. Do not use sharp
objects to remove unwanted labels. If necessary, carefully peel
the label off.
· An undercrawl mask is molded into the window allowing objects
to be placed within 5 feet of , or directly below the detector. This
mask can be removed cutting the three plastic tabs holding it in
place as shown in Figure 3.
Cut here to remove
Opening tab
Figure 3
Battery compartment
Tamper
Switches
Switch settings:
Figure 4
Figure 6
33'
STD
50'
B1
Pet Alley Application
Walk Testing the Detector
To create a detection free area close to the floor, mount the
detector about 3.5 feet above the floor, upside down (detector
window towards the ceiling). To reduce the exposure to the
ceiling, leave the plastic undercrawl mask in place.
The detector provides a Walktest mode for testing the detector
operation and coverage pattern. Use the following instructions to
walk test the detector:
As shown in Figure 7, pets are free to roam below the mounting
height of the detector without causing alarms.
1.
Remove the sensor from the bracket to enable the
Walktest mode.
2.
When the sensor is remounted on the bracket, the detector
remains in the Walktest mode for 3-4 minutes. Depending on
jumper settings, the Walktest mode allows the detector to alarm
whenever one or two curtain areas are entered. The LED visible
on the front cover lights to indicate an alarm.
3.
Walk test the detection pattern, remove the sensor, and make
any necessary adjustments.
4.
Replace the sensor, walk test the unit and verify the detector is
communicating with the control panel. Replace the securing
screw. See the control panel manufacturer’s instructions.
Important: After Walktest mode times out (3 to 4 minutes), the
detector returns to normal operating mode. In normal operating
mode, the detector will alarm no more often than once every 3
minutes, and the LED is disabled to reduce battery consumption.
Maintaining the Detector
Figure 7
When installed and used properly, the AP950W provides up to 10
years of service with minimal maintenance. To ensure proper
operation, you should walk test the detector annually as described
in Walk Testing the Detector.
Installing Batteries and Setting up the
Transmitter
Clean the inside of the detector with a soft bristled brush or
compressed air. Clean the cover with a damp (water) cloth as
needed to keep it free of dust and dirt. Always test the detector
after cleaning.
The detector contains a built-in transmitter that is used in
conjunction with a compatible receiver. Use the following
instructions to set up the transmitter for wireless operation:
1.
Make sure the tamper switch on PIR is released (not pressed
down), by removing the PIR from the wall mounting bracket.
2.
Observing the proper polarity, insert lithium batteries
provided into the battery holder.
Replacing the Batteries
Important: Once the batteries are installed, allow 3 minutes
Important: You must remove all batteries to reset the low
3.
4.
battery signal before installing new batteries.
for the detector to become fully operational before performing
walk testing.
Detach one of the device address labels from the transmitter
board and use it to enroll the detector at the control panel. See
the control panel manufacturer's instructions.
Walk test the detector to ensure proper operation and
coverage. See Walk Testing the Detector.
To ensure proper operation, if any battery is less than 3VDC,
replace all batteries.
Use only 3 V lithium CR-123A batteries as listed on the inside of
the detector.
Use of any other batteries may present a risk of fire or explosion.
Dispose of used batteries promptly. Keep away from children.
Caution: Risk of fire, explosion, and burns. Do not recharge,
disassemble, heat above 212°F (100°C), or incinerate. Dispose of
used batteries properly.
Specifications
FCC
This device complies with Part 15 of the FCC rules. Operation is
Input voltage.......................................................................2.35 to 3.3VDC
subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
supplied by three 3V lithium batteries provided
Battery type....................................................................DL123A, CR123A
Typical current.....................................................................................11uA
Typical battery life..........................................................................10 years
Transmitter frequency...................................................................345 Mhz
Transmit condition..........................................alarm, tamper, low battery
Detection range.........................................................................................35'
Mounting height..............................................................................7' to 10'
Number of curtains......................................................................................9
Operating temperature....................................32° to 131° F (0° to 55° C)
Relative humidity..........................................10 to 90% non-condensing
RFI immunity..........................................>10V/meter from 28 to 1000Mhz
Dimensions:
Width...................................................................................2.9" (7.4 cm)
Depth...................................................................................2.2" (5.6 cm)
Height................................................................................5.1" (12.9 cm)
Weight...................................................................................................7.7 oz
Color.......................................................................................................white
Recommended receiver...........................ADEMCO 5881, 5882, 6128RF
Ordering Information
Model number
Description
AP950W-ADT
AP950W wireless detector with three 3V lithium batteries.
This unit should be used with a UL listed control unit capable of providing a minimum of 4 hours standby power.
The equipment should be installed in accordance with NFPA 70. The unit shall be tested at least once a year.
ADT Security Services, Inc. • 1750 Clint Moore Rd. • Boca Raton, FL
1033439 09/00
©ADT Security Services, Inc. 2000
33431
Printed in USA

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Create Date                     : 2000:10:16 10:32:10
Producer                        : Acrobat Distiller 4.0 for Windows
Modify Date                     : 2000:10:16 10:32:14-07:00
Page Count                      : 4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: B4Z-788C-PIR

Navigation menu