UTC Fire and Security AA2 Field Disturbance Sensor for Security Systems User Manual 8

UTC Fire & Security B.V. Field Disturbance Sensor for Security Systems 8

8

Download: UTC Fire and Security AA2 Field Disturbance Sensor for Security Systems User Manual 8
Mirror Download [FCC.gov]UTC Fire and Security AA2 Field Disturbance Sensor for Security Systems User Manual 8
Document ID40419
Application IDNsfaYw42CrQ4psaQJc0GCA==
Document Description8
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize7.08kB (88546 bits)
Date Submitted1999-06-04 00:00:00
Date Available2000-09-15 00:00:00
Creation Date2001-06-18 21:37:24
Producing SoftwareAcrobat Distiller 4.0 for Windows
Document Lastmod2001-06-18 21:37:26
Document Title8

_ H SENTROL, INC —
Sentrol Ranger Field Disturbance Sensor- Commercial Application
Installation Instructions (Preliminary)
Application
The Sentrol Ranger Presence Sensor is designed for commercial applications where moving
objects or people need to be sensed, The unit is operated from a 12V power supply and includes
an on—board PIR detector for greater pet immunity and a decrease in false alarms.
Mounting Location
The sensor must be mounted on a stationary and vibration free object The top of the case
should face the direction that is to be monitored for movement. The sensor can "see“ in
approximately a 90” field of view, it cannot "see" towards the back of the sensor.
Mount the sensor with the 2 screws provided or with double-sided tape. Avoid touching the
electronics during the mounting procedure
Things to Avoid when Mounting the Ranger
Do not place metallic objects within the 1st two feet in front of the sensor or the sensor might be
blinded or may see objects in back of the sensor.
Do not mount the sensor close to moving or vibrating objects: washing machines. fans, pulleys.
etc. Moving or vibrating objects may cause false alarms.
Do not mount the sensor close to electrical disturbances: electrical motors. high voltage
equipment, etc.
Do not mount sensor where it is exposed to water spray or corrosive enVironment.
Adjusting the Sensitivity and Testing the Range
The Sentrol Ranger Presence Sensor is preset at the factory for optimum sensitivity for each
range. Each range can be tested separately with an on-board jumper at JG.
For normal operation the jumper at JB is factory set to a 35 ft range. Move jumper location to the
pins of the desired range.
Revmount the unit and this selected range can now be tested. Simply walk in front of the sensor
and note the distance where either an orange or red LED is lit
Installation Instructions 1
Wiring
Cut a hole through the indicated knockout at the back of the housing to run the panel wiring into
the unit. Attach +12Vdc, COM. NO‘ NC and Tamper wires from the panel to the marked terminal
blocks.
LED Indicators
LED Color Indication
Red Alarm (Relay changes state)
Green PIR Only Detection (no change in
relay slate)
Orange RangeGated RADAR Only Detection
(no change in relay state)
SPECIFICATIONS
Electrical
Supply Voltage EV to 15V
Current Draw ZOmA typical
Relay Rating 30V, 20mA maxt
Sensing Performance
Maximum Range 32 - 35 feet
Target Velocity 0.3 ftlsec to 5.0 itlsec
Min. Target Object Size 0.5 square foot profile of a diffuse metallic reflector at 10 feet
Environmental
Operating Temp 0° C to 50° C
Humidity 10% to 95% non-condensing
Installation Instructions 2
— SENTROL. iNc _
p I
Sentrol Dolphin Presence Sensor - For Industrial Automation Applications
Installation Instructions (Preliminary)
Application
The Sentrol Dolphin Presence Sensor is designed for industrial application: where moving
objects or people need to be sensed. The unit Is operated from a 12V power supply.
Applications might include electric door openers, video camera control. or any other application
whena a non-critical machine needs to be activated or deactivated when motion occur! within I
prescribed range of less than 20 feet.
Mounting Location
The sensor must be mounted on a stationary and vibration tree object. The top of the case
should race the direction that is to be monitored for movement The sensor can “see“ in
approximately a 180' field or view, it cannot “see" inwards the back oi the sensor. The Sensor will
have less sensitivity to the sides than the top and bottom. The sensor may be mounted sideways
it it is desired to optimize seniing in a sideways direction.
Mount the sensor with the 2 screws provided or with double-aided tape. Avoid touching the
‘ electronics during the mounting procedure.
Thing. to Avoid when Mounting the Dolphin
Do not place metallic objects within the tel 2 reet in front of the sensor of the sensor might be
blinded or may see objects in back of the sensor.
Do not mount the sensor close to moving or vibrating objects: washing machines. tans. pulleys,
etc.
Do not mount the sensor close to electrical disturbances: electrical motors, high voltage
equipment, etc.
Do not mount sensor where it ie exposed to water spray or corrosive environment
Adjusting the Range and Sensitivity
With it email slotted screw driver,
1. Adjust the RANGE and SENS potentiometers to the middle or their scale. The sensor should
now be able to sense movements or your hand within the range at approximately 10 reel.
2. Now adjust the RANGE potentiometer until it operates to your desired range.
3. Adjust the SENS potentiometer so It easily senses the object you are trying to sense at the
maximum range. but not an object which Is 1/2 the size oi the object you are trying to sense.
Installation Instructions 1
man;
Attach a 12V power supply to the marked terminal blocks.
SPECIFICATIONS
Electrical
Supply Voltage 6V lo 15V
Current Draw 10mA typical
Alarm Pin Rating 30V peak. ZOmA max.
Sonllnn Performance
Maximum Range 20 feet mlnlrnum
Target Velocity 1 Riser. to 30 film:
Target Object Size 0.5 square fool profile of a nietalllc object at 10 feel
Environmental
Operating Temperelure 0' F to 120‘ F
Humidity my. to 9598 non-condenslng
FEDERAL COlvflVIUNICATIONS COMMISSION (F.C.C.) STATEMENT
This equipment has been tested and found to comply with the limits ofa Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a resideno‘al
installation. This equipment generates, uses and can radiate radio frequency energy and , if not installed and used in
accordance with the instructions. may cause harmful interference to radio communications However, there is no
guarantee that interference will not occur in a particular installation, if this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more ofthe following measures:
1. Reorient / Relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit difi‘erent from that to which the receiver is connected.
4. Consult the dealer or an experienced radio/ TV technician for help.
CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for
compliance could void the user‘s authority to operate the equipment.
installation Instructions 2

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Create Date                     : 2001:06:18 21:37:24
Producer                        : Acrobat Distiller 4.0 for Windows
Modify Date                     : 2001:06:18 21:37:26-04:00
Page Count                      : 4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CGGAA2

Navigation menu