Ubiquiti AF24 24 GHz Point-to-Point Radio User Manual manual
Ubiquiti Networks, Inc. 24 GHz Point-to-Point Radio manual
Ubiquiti >
manual
24 GHz Point to Point 1.4+ Gbps Radio Model: AF24 Introduction Introduction Thank you for purchasing the airFiber™ 24 GHz Point-to-Point Radio, model AF24. This Quick Start Guide is designed to guide you through the installation of the airFiber AF24 and show you how to access the airFiber Configuration Interface. Package Contents airFiber AF24 M10x150 Carriage Bolts (Qty. 4) Pole Mount Bracket M10 Flat Washers (Qty. 4) Pole Clamps (Qty. 2) M10 Split Lock Washers (Qty. 4) M10 Hex Nuts (Qty. 4) Cable Ties (Qty. 3) M8x16 Serrated Flange Screws (Qty. 4) 24 GHz Point to Point 1.4+ Gbps Radio Model: AF24 airFiber AF24 Quick Start Guide PoE Adapter (50V, 1.2A GigE) Power Cord airFiber™ Quick Start Guide Hardware Overview Side Lock Bolts Alignment Bracket Elevation Adjustment Azimuth Adjustment Lock Bolts Ground Bonding Point Hardware Overview Back Lock Bolts Lock Bolts Elevation Adjustment Azimuth Adjustment Lock Bolts Lock Bolts Port Cover airFiber™ Quick Start Guide Interfaces RESET DATA Interface AUX LED Display CONFIG Description RESET To reset to factory defaults, press and hold the RESET button for more than five seconds while the unit is already powered on. DATA 10/100/1000 Mbps port handles all user traffic. AUX Port for audio tone aiming. LED Display Digital display used for power, status, and mode information. CONFIG 10/100 Mbps, secured port for configuration. By default, this is the only port that can monitor, configure, and/or update firmware. LEDs Speed RX Power GPS Link/Act Master/Slave Speed Modulation Link/Act RF Link Status Hardware Overview LED DATA Speed Link/Act AUX GPS Modulation State Status Off 10/100 Mbps On 1000 Mbps Off No Ethernet Link On Ethernet Link Established Random Flashing Ethernet Activity Off No GPS Synchronization On Operational (Strong Signal) Normal Flash* Operational (Weak Signal) Off 1x (QPSK SISO) Short Flash* 2x (QPSK MIMO) Normal Flash* 4x (16QAM MIMO) Long Flash* 6x (64QAM MIMO) Number RX Power Flashing Number (-dBm) Decodable RX Signal Undecodable RX Signal LED Display Overload Condition Master/ Off Slave On Slave Mode Master Mode Off RF Off Short Flash* Syncing RF Link Normal Flash* Status Long Flash* CONFIG Speed Link/Act Beaconing Registering On Operational Off 10 Mbps On 100 Mbps Off No Ethernet Link On Ethernet Link Established Random Flashing Ethernet Activity Short Flash (1:3 on/off cycle) Normal Flash (1:1 on/off cycle) Long Flash (3:1 on/off cycle) airFiber™ Quick Start Guide Installation Requirements • 17 mm wrench • 13 mm socket wrench or driver • Clear line of sight between airFiber radios • Clear view of the sky for proper GPS operation • Mounting location with < 0.5° displacement due to twist and sway under wind loading • Mounting point: • At least 1 meter below the highest point on the structure • For tower installations, at least 3 meters below the top of the tower • Ground wire – min. 8 AWG (10 mm2), max. length: 1 meter • (Recommended) 2 Outdoor GigE PoE surge protectors Note: For guidelines about grounding and lightning protection, follow your local electrical regulatory codes. • Outdoor, shielded Category 5e (or above) cabling should be used for all wired Ethernet connections. Category 6 is required for installations with long cable runs (up to 100 m). We recommend that you protect your networks from the most brutal environments and devastating ESD attacks with industrial‑grade shielded Ethernet cable from Ubiquiti Networks. For more details, visit www.ubnt.com/toughcable Installation Overview We recommend that you configure your paired airFiber radios before mounting. To configure device settings in the airFiber Configuration Interface, you will need to connect Power over Ethernet to the DATA port and connect an Ethernet cable between your computer and the CONFIG port. Once you have completed configuration, disconnect the cables to move the airFiber radios, and then reconnect at the site. After you have mounted the airFiber radios, then you can establish and optimize the RF link. Connecting Power over Ethernet Connecting Power over Ethernet 1. Press down on the indicator arrows and slide the Port Cover off. 2. Connect an Ethernet cable to the DATA port. airFiber™ Quick Start Guide 3. Connect the other end of the Ethernet cable from the DATA port to the Ethernet port labeled POE on the PoE Adapter. 4. Connect the Power Cord to the power port on the PoE Adapter. Connect the other end of the Power Cord to a power source. airFiber Configuration airFiber Configuration The instructions in this section explain how to access the airFiber Configuration Interface and configure the following settings: • Wireless Mode Configure one airFiber AF24 as the Master and the other as the Slave. • Duplex The airFiber AF24 supports both half-duplex and full‑duplex operation. Half-duplex operation provides more frequency planning options at the cost of higher latency and throughput. Full-duplex operation provides the highest throughput and lowest latency; however, you have fewer frequency management options. -- Half Duplex (default) The TX and RX Frequencies are the same. RX RX Freque cy A Freque cy A TX TX Master Slave Half-Duplex Diagram -- Full Duplex The TX and RX Frequencies should be different. RX RX Freque cy A Freque cy B TX TX Master Slave Full-Duplex Diagram • TX and RX Frequencies The TX Frequency on the Master must match the RX Frequency on the Slave, and vice versa. airFiber™ Quick Start Guide 1. Connect an Ethernet cable from your computer to the CONFIG port on the airFiber AF24. 2. Configure the Ethernet adapter on your computer with a static IP address on the 192.168.1.x subnet (for example, 192.168.1.100). 3. Launch your Web browser. Type http://192.168.1.20 in the address field and press enter (PC) or return (Mac). 4. The login screen will appear. Enter ubnt in the Username and Password fields. Select your Country and Language. You must agree to the Terms of Use to use the product. Click Login. Note: U.S. product versions are locked to the U.S. Country Code to ensure compliance with FCC regulations. 10 airFiber Configuration 5. Click the Wireless tab. 6. Enter the Basic Wireless Settings: a. For one airFiber AF24, select Master from the WIreless Mode drop-down. For the other airFiber AF24, keep the default, Slave. b. Enter a name in the Link Name field. This should be the same on both the Master and the Slave. c. For the Duplex drop-down: -- Half Duplex The default mode. The TX and RX Frequencies are the same. -- Full Duplex The TX and RX Frequencies should be different. d. Select a TX Frequency. This must match the RX Frequency on your other airFiber AF24. e. Select a RX Frequency. This must match the TX Frequency of your other airFiber AF24. f. If needed, change the Output Power, Maximum Modulation Rate, and/or RX Gain settings. 11 airFiber™ Quick Start Guide 7. Configure the Wireless Security: a. Select the AES Key Type, HEX or ASCII. b. For the Key field: -- HEX Enter 16 bytes (eight, 16-bit HEX values: 0-9, A-F, or a-f ). You can omit zeroes and use colons, similar to the IPv6 format. Note: The airFiber Configuration Interface supports IPv6 formats excluding dotted quad and "::" (doublecolon) notation. -- ASCII Enter a combination of alphanumeric characters (0-9, A-Z, or a-z). 8. Click Change and then click Apply. 9. By default, in-band management is disabled. To enable in-band management: a. Click the Network tab. b. Check the box next to In-Band Management. c. Change the IP Address, Netmask, and other settings to make them compatible with your network. Note: If In-Band Management is enabled, each airFiber radio must have a unique IP Address. If the airFiber radios use the same IP Address, then you may lose access to the airFiber radios via the CONFIG and DATA ports. d. Click Change and then click Apply. Repeat the instructions in the airFiber Configuration section on your other airFiber radio. After you have configured the airFiber radios, disconnect them and move them to your installation site. 12 Hardware Installation Hardware Installation To install the airFiber AF24: 1. Insert the four M10x150 Carriage Bolts into the Pole Mount Bracket. 2. Attach the Pole Mount Bracket to a pole. Orient the Pole Mount Bracket so it is aimed in the direction of the other airFiber AF24. Slip the Pole Clamps onto the M10x150 Carriage Bolts. Secure the clamps with the M10 Flat Washers, Split Lock Washers, and Hex Nuts. Aim towards link. 13 airFiber™ Quick Start Guide 3. Secure the four M8x16 Serrated Flange Screws to the back of the Alignment Bracket. Do not completely tighten the screws; leave a 6 mm gap between the screw head and the bracket. 6 mm 14 Hardware Installation 4. Lift the airFiber AF24 and align the four M8x16 Serrated Flange Screws with the slots on the Pole Mount Bracket. Seat the screws in the slots. Securely tighten the screws. WARNING: To prevent injury, ensure that all four screws are seated and fully tightened. 15 airFiber™ Quick Start Guide 5. Attach a ground wire by performing the following steps: a. Remove the nut from the Ground Bonding Point. b. Attach a ground wire (min. 8 AWG or 10 mm2) to the lug and replace the nut to secure the wire. c. Secure the other end of the ground wire to the pole, tower, or grounding bar. Note: The ground wire should be as short as possible and no longer than one meter in length. 16 Connecting Ethernet Connecting Ethernet 1. Press down on the indicator arrows and slide the Port Cover off. 2. Connect a TOUGHCable or other outdoor, shielded CAT5e/6 cable to the DATA port. 3. Create a strain relief for the Ethernet cable by feeding a cable tie through the tie slot under the cable. Then wrap the cable tie around the cable and tighten. 17 airFiber™ Quick Start Guide 4. Connect the other end of the Ethernet cable from the DATA port to the Ethernet port labeled POE on the PoE Adapter. 5. Connect an Ethernet cable from your network to the Ethernet port labeled LAN on the PoE Adapter. 6. Connect the Power Cord to the power port on the PoE Adapter. Connect the other end of the Power Cord to a power source. 18 Note: For added protection, we recommend installing two GigE PoE surge protectors. Install the first surge protector within one meter of the airFiber DATA port, and install the second surge protector at the ingress point of the location housing the wired network equipment. Connecting Ethernet Below is a diagram of a finished installation with recommended surge protectors installed. Max. 1 m Ground to Pole, Tower, or Grounding Block (Max. 1 m from Ground Bonding Point) Outdoor GigE PoE Surge Protector GigE Router or Switch Outdoor GigE PoE Surge Protector GigE PoE Adapter Power Source 19 airFiber™ Quick Start Guide Alignment To align the airFiber radios for best performance, you MUST align only one end of the link at a time. Begin the alignment process with the Slave first. 1. Loosen, but do NOT remove the eight Lock Bolts located on the Alignment Bracket. 2. While adjusting the azimuth, observe the numeric LED Display located next to the CONFIG port. The values are displayed in negative (-) dBm. Adjust the azimuth for the strongest received signal level. For example, a displayed value of 42 represents a received signal level of -42 dBm, which is a stronger received signal than 47, which represents -47 dBm. Azimuth (AZ) Adjustment Bolt RF Power (-dBm) Note: If the LED Displays indicates an overload condition , refer to the airFiber AF24 User Guide at: www.ubnt.com/documentation for more information. 20 Alignment 3. Observe the LED display and adjust the elevation until the strongest received signal level is displayed. Elevation (EL) Adjustment Bolt RF Power (-dBm) 4. Repeat steps 1-3 for the Master. 5. On the Slave, repeat steps 2-3 to finalize the alignment. 6. On the Master, repeat steps 2-3 to finalize the alignment. 7. Lock the alignment on both airFiber radios by tightening all eight Lock Bolts on the Alignment Bracket. Observe the LED Display on each airFiber AF24 to ensure that the value remains constant while tightening the Lock Bolts. If the LED value changes during the locking process, loosen the Lock Bolts, finalize the alignment of each airFiber AF24 again, and retighten the Lock Bolts. Note: There are three methods for fine-tuning the alignment: • LED display (described above) • airFiber Configuration Interface • audio tone (optional equipment required) Refer to the airFiber AF24 User Guide for instructions on the airFiber Configuration Interface and audio tone methods. The User Guide is available at: www.ubnt.com/documentation 21 airFiber™ Quick Start Guide Specifications airFiber AF24 Operating Frequency Dimensions Weight Max Power Consumption 24.05 – 24.25 GHz 649 x 426 x 303 mm 10.5 kg (Mount Included) < 50 Watts Power Supply 50V, 1.2A PoE GigE Adapter (Included) Power Method Passive Power over Ethernet (42-58V) Certifications CE, FCC, IC Mounting Pole Mount Kit (Included) Operating Temperature -40 to 55° C (-40 to 131° F) Networking Interface Data Port Configuration Port 22 (1) 10/100/1000 Ethernet Port (1) 10/100 Ethernet Port Installer Compliance Responsibility Installer Compliance Responsibility Devices must be professionally installed and it is the professional installer's responsibility to make sure the device is operated within local country regulatory requirements. The Frequencies and Output Power fields are provided to the professional installer to assist in meeting regulatory requirements. Safety Notices 1. Read, follow, and keep these instructions. 2. Heed all warnings. 3. Only use attachments/accessories specified by the manufacturer. WARNING: Do not use this product in location that can be submerged by water. WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning. Electrical Safety Information 1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed. 2. There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician. 23 airFiber™ Quick Start Guide 3. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet. a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire. b. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death. c. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment. d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection. e. Protective bonding must be installed in accordance with local national wiring rules and regulations. General Warranty UBIQUITI NETWORKS, Inc (“UBIQUITI NETWORKS”) represents and warrants that the Products furnished hereunder shall be free from defects in material and workmanship for a period of one (1) year from the date of shipment by UBIQUITI NETWORKS under normal use and operation. UBIQUITI NETWORKS sole and exclusive obligation under the foregoing warranty shall be to repair or replace, at its option, any defective Product that fails during the warranty period. The expense of removal and reinstallation of any item is not included in this warranty. The foregoing warranty is exclusive and in lieu of all other warranties, express or implied, including the implied warranties of merchantability and fitness for a particular purpose and any warranties arising from a course of dealing, usage or trade practice with respect to the products. Repair or replacement in the manner provided herein shall be the sole and exclusive remedy of Buyer for breach of warranty and shall constitute fulfillment of all liabilities of UBIQUITI NETWORKS with respect to the quality and performance of the Products. UBIQUITI NETWORKS reserves the right to inspect all defective Products (which must be returned by Buyer to UBIQUITI NETWORKS factory freight prepaid). No Products will be accepted for replacement or repair without obtaining a Return Materials Authorization (RMA) number from UBIQUITI NETWORKS. Products returned without an RMA number will not be processed and will be returned to Buyer freight collect. UBIQUITI NETWORKS shall have no obligation to make repairs or replacement necessitated by catastrophe, fault, negligence, misuse, abuse, or accident by Buyer, Buyer’s customers or any other parties. The warranty period of any repaired or replaced. Product shall not extend beyond its original term. 24 Compliance Warranty Conditions The foregoing warranty shall apply only if: (I) The Product has not been subjected to misuse, neglect or unusual physical, electrical or electromagnetic stress, or some other type of accident. (II) No modification, alteration or addition has been made to the Product by persons other than UBIQUITI NETWORKS or UBIQUITI NETWORK’S authorized representatives or otherwise approved by UBIQUITI NETWORKS. (III) The Product has been properly installed and used at all times in accordance, and in all material respects, with the applicable Product documentation. (IV) All Ethernet cabling runs use CAT5 (or above) shielded cabling. Disclaimer: UBIQUITI NETWORKS does not warrant that the operation of the products is error-free or that operation will be uninterrupted. In no event shall UBIQUITI NETWORKS be responsible for damages or claims of any nature or description relating to system performance, including coverage, buyer’s selection of products for buyer’s application and/or failure of products to meet government or regulatory requirements. Returns In the unlikely event a defect occurs, please work through the dealer or distributor from which this product was purchased. Compliance FCC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 25 airFiber™ Quick Start Guide For MPE and antenna usage details, please visit our website at www.ubnt.com/products Industry Canada This Class A digital apparatus complies with Canadian ICES-003. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and 2. This device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil numérique de la classe A est confrome à la norme NMB-003 Canada. Pour réduire le risque d’interférence aux autres utilisateurs, le type d’antenne et son gain doivent être choisies de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire pour une communication réussie. Cet appareil est conforme à la norme RSS Industrie Canada exempts de licence norme(s). Son fonctionnement est soumis aux deux conditions suivantes: 1. Cet appareil ne peut pas provoquer d’interférences et 2. Cet appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif. RF Exposure Warning The antennas used for this transmitter must be installed to provide a separation distance of at least 110 cm from all persons and must not be located or operating in conjunction with any other antenna or transmitter, except as listed for this product's certification. Les antennes utilisées pour ce transmetteur doivent être installé en considérant une distance de séparation de toute personnes d'au moins 110 cm et ne doivent pas être localisé ou utilisé en conflit avec tout autre antenne ou transmetteur, excluant la liste de certification de ce produit. CE Marking CE marking on this product represents the product is in compliance with all directives that are applicable to it. 26 Declaration of Conformity Alert Sign (!) Follows CE Marking Alert sign must be indicated if a restriction on use applied to the product and it must follow the CE marking. Declaration of Conformity Česky [Czech] UBIQUITI NETWORKS tímto prohla uje, e tento UBIQUITI NETWORKS device, je ve shod se základními po adavky a dal ími p íslu n mi ustanoveními sm rnice 1999/5/ES. Dansk [Danish] Undertegnede UBIQUITI NETWORKS erklærer herved, at følgende udstyr UBIQUITI NETWORKS device, overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF. Nederlands [Dutch] Hierbij verklaart UBIQUITI NETWORKS dat het toestel UBIQUITI NETWORKS device, in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG. Bij deze verklaart UBIQUITI NETWORKS dat deze UBIQUITI NETWORKS device, voldoet aan de essentiële eisen en aan de overige relevante bepalingen van Richtlijn 1999/5/EC. English Hereby, UBIQUITI NETWORKS, declares that this UBIQUITI NETWORKS device, is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Eesti [Estonian] Käesolevaga kinnitab UBIQUITI NETWORKS seadme UBIQUITI NETWORKS device, vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele. Suomi [Finnish] UBIQUITI NETWORKS vakuuttaa täten että UBIQUITI NETWORKS device, tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen. Français [French] Par la présente UBIQUITI NETWORKS déclare que l’appareil UBIQUITI NETWORKS, device est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. Deutsch [German] Hiermit erklärt UBIQUITI NETWORKS, dass sich diese UBIQUITI NETWORKS device, in Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet”. (BMWi) Ελληνική [Greek] ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ UBIQUITI NETWORKS ΔΗΛΩΝΕΙ ΟΤΙ UBIQUITI NETWORKS device, ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1995/5/ΕΚ. Magyar [Hungarian] Alulírott, UBIQUITI NETWORKS nyilatkozom, hogy a UBIQUITI NETWORKS device, megfelel a vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak. 27 airFiber™ Quick Start Guide Íslenska [Icelandic] Hér me l sir UBIQUITI NETWORKS yfir ví a UBIQUITI NETWORKS device, er í samræmi vi grunnkröfur og a rar kröfur, sem ger ar eru í tilskipun 1999/5/EC. Italiano [Italian] Con la presente UBIQUITI NETWORKS dichiara che questo UBIQUITI NETWORKS device, è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. Latviski [Latvian] Ar o UBIQUITI NETWORKS deklar , ka UBIQUITI NETWORKS device, atbilst Direkt vas 1999/5/EK b tiskaj m pras b m un citiem ar to saist tajiem noteikumiem. Lietuviškai [Lithuanian] UBIQUITI NETWORKS deklaruoja, kad šis UBIQUITI NETWORKS įrenginys atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas. Malti [Maltese] Hawnhekk, UBIQUITI NETWORKS, jiddikjara li dan UBIQUITI NETWORKS device, jikkonforma mal- ti ijiet essenzjali u ma provvedimenti o rajn relevanti li hemm fid-Dirrettiva 1999/5/EC. Norsk [Norwegian] UBIQUITI NETWORKS erklærer herved at utstyret UBIQUITI NETWORKS device, er i samsvar med de grunnleggende krav og øvrige relevante krav i direktiv 1999/5/EF. Slovensky [Slovak] UBIQUITI NETWORKS t mto vyhlasuje, e UBIQUITI NETWORKS device, sp a základné po iadavky a v etky príslu né ustanovenia Smernice 1999/5/ES. Svenska [Swedish] Härmed intygar UBIQUITI NETWORKS att denna UBIQUITI NETWORKS device, står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG. Español [Spanish] Por medio de la presente UBIQUITI NETWORKS declara que el UBIQUITI NETWORKS device, cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. Polski [Polish] Niniejszym, firma UBIQUITI NETWORKS o wiadcza, e produkt serii UBIQUITI NETWORKS device, spełnia zasadnicze wymagania i inne istotne postanowienia Dyrektywy 1999/5/EC. Português [Portuguese] UBIQUITI NETWORKS declara que este UBIQUITI NETWORKS device, está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE. Română [Romanian] Prin prezenta, declarăm că acest produs este în conformitate cu cerinţele esenţiale şi cu alte prevederi relevante din Directiva 1999/5/CE. PHRRJL040512 28 Ubiquiti Networks Support Email: support@ubnt.com Phone (9 a.m. - 5 p.m. PST): 408-942-1153 Online Resources Wiki Page: wiki.ubnt.com Support Forum: forum.ubnt.com Downloads: downloads.ubnt.com www.ubnt.com © 2012 Ubiquiti Networks, Inc. All rights reserved.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Tagged PDF : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Modify Date : 2012:05:25 13:01:37-04:00 Create Date : 2012:04:05 12:49:49-07:00 Metadata Date : 2012:05:25 13:01:37-04:00 Format : application/pdf Document ID : uuid:339c7396-b225-a348-8f19-fd58c43550eb Instance ID : uuid:d2abfba1-52fc-4be7-b754-02e5a2fb5b80 Page Count : 32 Page Layout : TwoPageRightEXIF Metadata provided by EXIF.tools