Uninterrupted
Power Supply (UPS)
The Ultimate Power Protection!
If you're looking for the most complete, technologically advanced power
protection unit for the money, the Ultra UPS line is exactly what you need. An
Ultra UPS is an absolute must for anyone running a small server, workstation or a
powerful PC. You simply cannot afford to cut corners when it comes to
safeguarding your valuable equipment, and these UPS's deliver the
comprehensive protection for computer, peripherals and data files at a
remarkably low price.

Features
- Line Interactive Design
- AVR (Automatic Voltage Regulation)
- Fully Digitized Microprocessor Controlled
- Protects up to 4 Devices at Once
- Energy Saving Function (UPS Green Mode)
- 50/60Hz Frequency Auto Sensing and Selection
- USB Communication Port
- Advanced Battery Management (ABM Technology)

Gneral

Output

Input
Protection

Battery

1000VA
ULT31502
About 50 Minutes

1025VA
ULT33044
About 50 Minutes

1500VA
ULT33045
About 60 Minutes

2000VA
ULT33046
About 65 Minutes

Net Weight Kg (lbs)
Digital Display
Watts
UPS Capacity
No. of Sockets
Voltage (Battery)
Frequency (Battery)
Transfer Time
Voltage (Single Phase)
Frequency
Unit Input
Overload Protection

28.6(63.0)
Yes
615
1025VA
Style A UPSx4, Bypassx2
Simulated square wave output at nominal +/-5%
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
UPS automatic power off if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds

28.6(63.0)
Yes
615
1025VA
Style A UPSx4, Bypassx2
Simulated square wave output at nominal +/-5%
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
UPS automatic power off if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds

Yes
900
1500VA
Style A UPSx4, Bypassx2
Simulated square wave output at nominal +/-5%
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
UPS automatic power off if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds

Yes
1200
2000VA
Style A UPSx4, Bypassx2
Simulated square wave output at nominal +/-5%
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
UPS automatic power off if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds

Short Circuit
Surge Protection
Type

UPS output shuts off immediately
2100 Joules
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Slow beeping sound every 4 seconds
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
Continue beeping sound
3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30 ͠

UPS output shuts off immediately
2100 Joules
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Slow beeping sound every 4 seconds
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
Continue beeping sound
3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30 ͠

UPS output shuts off immediately
2100 Joules
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Slow beeping sound every 4 seconds
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
Continue beeping sound
3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30 ͠

UPS output shuts off immediately
2100 Joules
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Slow beeping sound every 4 seconds
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
Continue beeping sound
3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30 ͠

Sku
Backup Time

Typical Recharge Time
Protection
Interface
Alarm

Includes
UPS Monitoring
Software

USB

Battery Backup
Battery Low
Abnormal Charge
Overload
Environment Ambient Operation

Automatic Voltage Regulation (AVR)
Protect your computer from electrical damage caused
by dangerous "spikes and sags".
$125,000 Limited Warranty

Includes
UPS Monitoring
Software

1-800-830-0051
www.ultraproducts.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Count                      : 1
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:25950130-e88f-4728-bd79-078915a70ca4
Producer                        : Acrobat Distiller 6.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2006:11:21 08:53:11-05:00
Create Date                     : 2006:11:21 08:53:11-05:00
Document ID                     : uuid:8db38d50-57ce-447a-a744-a5e979561a69
Format                          : application/pdf
Title                           : UPS_2.ai
Creator                         : TCMM2335
Author                          : TCMM2335
EXIF Metadata provided by EXIF.tools

Navigation menu