                 Product  Safety  and  RF  Energy  Exposure  Booklet        for Unication Two-Way Portable Radios The information provided in this document supersedes the general safety information contained in user guides published prior to August 2010.
~2~                                     U3 Radio Safety Booklet English Version  BEFORE USING THIS RADIO, PLEASE READ THIS BOOKLET WHICH CONTAINS IMPORTANT OPERATING INSTRUCTIONS FOR SAFE USAGES AND RF ENERGY AWARENESS AND CONTROL INFORMATION AND OPERATIONAL INSTRUCTIONS FOR COMPLIANCE WITH RF ENERGY EXPOSURE LIMITS IN APPLICABLE NATIONAL AND INTERNATIONAL STANDARDS.  ALSO PLEASE READ THE OPERATIONAL INSTRUCTIONS FOR SAFE USAGE. FOR RADIOS THAT HAVE BEEN APPROVED AS INTRINSICALLY SAFE, READ THE INSTRUCTIONS AND INFORMATION ON INTRINSIC SAFETY ON PAGE 11 OF THIS BOOKLET.
~3~                                     U3 Radio Safety Booklet English Version RF Energy Exposure Awareness and Control Information and Operational Instructions for Occupational Use  NOTICE:    This radio is intended for use in occupational/controlled conditions where users have full knowledge of their exposure and can exercise control over their exposure to meet the occupational limits in FCC and International standards. This radio device is NOT authorized for general population consumer use. This two-way radio uses electromagnetic energy in the radio frequency (RF) spectrum to provide communications between two or more users over a distance.  It applies radio waves or radio frequency (RF) energy to transmit and receive voice calls or data. RF energy is one form of electromagnetic energy. Other forms include, but are not limited to, sunlight and x-rays. RF energy, however, should not be confused with these other forms of electromagnetic energy, which when used improperly, can cause biological damage. Very high levels of x-rays, for example, can damage tissues and genetic material.  Experts in science, engineering, medicine, health, and industry work with organizations to develop standards for safe exposure to RF energy. These standards provide recommended levels of RF exposure for both workers and the general public. These recommended RF exposure levels include substantial margins of protection.  All Unication two-way radios are designed, manufactured, and tested to ensure they meet government-established RF exposure levels. Additionally, manufacturers also recommend specific operating instructions to users of two-way radios. These instructions are essential as they inform users about RF energy exposure and provide simple procedures on how to control it.
~4~                                     U3 Radio Safety Booklet English Version Please refer to the following websites for more information on what RF energy exposure is and how to control your exposure to assure compliance with established RF exposure limits: http://www.fcc.gov/oet/rfsafety/rf-faqs.html http://www.osha.gov/SLTC/radiofrequencyradiation/index.html  Federal Communication Commission (FCC) Regulations The FCC rules require manufacturers to comply with the FCC RF energy exposure limits for portable two-way radios before they can be marketed in the U.S. When two-way radios are used as a consequence of employment, the FCC requires users to be fully aware of and able to control their exposure to meet occupational requirements. Exposure awareness can be facilitated by the use of a product label directing users to specific user awareness information. Your Unication two-way radio has a RF Exposure Product Label. Also, your Unication user manual or separate safety booklet includes information and operating instructions required to control your RF exposure and to satisfy compliance requirements.    Compliance with RF Exposure Standards Your Unication two-way radio is designed and tested to comply with a number of national and International standards and guidelines (listed below) for human exposure to radio frequency electromagnetic energy. This radio complies with the IEEE (FCC) and ICNIRP exposure limits for occupational/controlled RF exposure environments at operating duty factors of up to 50% talk-50% listen and is authorized by the FCC for occupational use only. In terms of measuring RF energy for compliance with these exposure guidelines, your radio generates measurable RF energy only while it is transmitting (during talking), not when it is receiving (listening) or in standby mode.   NOTE:   The approved batteries, supplied with this radio, are rated for a 5-5-90 duty factor (5% talk - 5% listen - 90% standby) even though this radio complies with FCC occupational exposure limits and may operate at duty factors of up to 50% talk.
~5~                                     U3 Radio Safety Booklet English Version Your Unication two-way radio complies with the following RF energy exposure standards and guidelines: •  United States Federal Communications Commission, Code of Federal Regulations; 47CFR part 2 sub-part J •  American National Standards Institute (ANSI) / Institute of Electrical and Electronic Engineers (IEEE) C95. 1-1992 •  Institute of Electrical and Electronic Engineers (IEEE) C95.1-1999 Edition •  International Commission on Non-Ionizing Radiation Protection (ICNIRP) 1998 •  Ministry of Health (Canada) Safety Code 6. Limits of Human Exposure to Radiofrequency Electromagnetic Fields in the Frequency Range from 3 kHz to 300 GHz, 1999 •  Australian Communications Authority Radio communications (Electromagnetic Radiation – Human Exposure) Standard, 2003 •  ANATEL ANNEX to Resolution No. 303 of July 2, 2002 "Regulation of limitation of exposure to electrical, magnetic and electromagnetic fields in the radio frequency range between 9 KHz and 300 GHz" and "Attachment to resolution # 303 from July 2, 2002"
~6~                                     U3 Radio Safety Booklet English Version RF Exposure Compliance and Control Guidelines and Operating Instructions To control your exposure and ensure compliance with the occupational/controlled environment exposure limits, always adhere to the following procedures. Guidelines: •  Do not remove the RF Exposure Label from the device. •  User awareness instructions should accompany device when transferred to other users. •  Do not use this device if the operational requirements described herein are not met.Operating Instructions •  Transmit no more than the rated duty factor of 50% of the time. To transmit (talk), push the Push-To-Talk (PTT) button. To receive calls, release the PTT button. Transmitting 50% of the time, or less, is important because this radio generates measurable RF energy exposure only when transmitting (in terms of measuring for standards compliance).  •  Hold the radio in a vertical position in front of the face with the microphone (and other parts of the radio including the antenna) at least one inch (2.54 centimeters) away from the nose or lips. Antenna should be kept away from the eye. Keeping the radio at a proper distance is important since RF exposures decrease with increasing distance from the antenna.   •  When worn on the body, always place the radio in the Unication-approved belt clip for this product. Using approved bodyworn accessories is important because the use of non-Unication-approved accessories may cause exposure levels, which exceed the FCC occupational/controlled environment RF exposure limits.
~7~                                     U3 Radio Safety Booklet English Version •  If you are not using a body-worn accessory and are not using the radio in the intended-use position in front of the face (one inch away), ensure the antenna and the radio are kept at least 0.75 inches (1.9 centimeters) from the body when transmitting. Keeping the radio at a proper distance is important because RF exposures decrease with increasing distance from the antenna.  Approved Accessories •  Use only Unication-approved supplied or replacement antennas, batteries, and accessories. Use of Non-Unication approved antennas, batteries, and accessories may exceed the FCC (IEEE) and ICNIRP RF exposure guidelines.  •  For a list of Unication-approved accessories, visit the following website, which lists approved accessories for your radio model or contact our local agents and distributors for more information: http://www.uni.com.tw/U32wayradio.html 
~8~                                     U3 Radio Safety Booklet English Version Electromagnetic Interference/Compatibility NOTE:  Nearly every electronic device is susceptible to electromagnetic interference (EMI) if inadequately shielded, designed, or otherwise configured for electromagnetic compatibility. Facilities To avoid electromagnetic interference and/or compatibility conflicts, turn off your radio in any facility where posted notices instruct you to do so. Hospitals or health care facilities may be using equipment that is sensitive to external RF energy.  Aircraft When instructed to do so, turn off your radio when on board an aircraft. Any use of a radio must be in accordance with applicable regulations per airline crew instructions.  Medical Devices Pacemakers The Advanced Medical Technology Association (AdvaMed) recommends that a minimum separation of 6 inches (15 centimeters) be maintained between a handheld wireless radio and a pacemaker. These recommendations are consistent with those of the U.S. Food and Drug Administration.  Persons with pacemakers should: •  ALWAYS keep the radio more than 6 inches (15 centimeters) from their pacemaker when the radio is turned ON. •  Not carry the radio in the breast pocket. •  Use the ear opposite the pacemaker to minimize the potential for interference. •  Turn the radio OFF immediately if there is any reason to suspect that interference
~9~                                     U3 Radio Safety Booklet English Version is taking place. Hearing Aids Some digital wireless radios may interfere with some hearing aids. In the event of such interference, you may want to consult your hearing aid manufacturer to discuss alternatives.  Other Medical Devices If any other personal medical devices are used, please consult the manufacturer of your device to determine if it is adequately shielded from RF energy. Your physician may be able to assist you in obtaining this information.  Use of Communication Devices While Driving Always check the laws and regulations on the use of radios in the areas where you drive. •        Give full attention to driving and to the road. •        Use hands-free operation, if available. •     Pull off the road and park before making or answering a call, if driving conditions or regulations so require.  
~10~                                     U3 Radio Safety Booklet English Version Operational Warnings For Vehicle with Air Bags: Refer to vehicle manufacturer's manual prior to installation of electronic equipment to avoid interference with air bag wiring. Do not place a portable radio in the area over an air bag or in the air bag deployment area. Air bags inflate with great force. If a portable radio is placed in the air bag deployment area and the air bag inflates, the radio may be propelled with great force and cause serious injury to occupants of the vehicle.  Potentially Explosive Atmospheres (Explosive atmospheres refer to hazard classified locations that may contain hazardous gas, vapors, or dusts.) Turn off your radio prior to entering any area with a potentially explosive atmosphere unless it is a portable radio type especially qualified for use in such areas as Intrinsically Safe (for example, Factory Mutual, CSA, UL, or CENELEC). Do not remove, install, or charge batteries in such areas. Sparks in a potentially explosive atmosphere can cause an explosion or fire resulting in bodily injury or even death. The areas with potentially explosive atmospheres referred to above include fueling areas such as below decks on boats, fuel or chemical transfer or storage facilities, and areas where the air contains chemicals or particles such as grain, dust or metal powders. Areas with potentially explosive atmospheres are often, but not always, posted. Blasting Caps and Blasting Areas To avoid possible interference with blasting operations, turn off your radio when you are near electrical blasting caps, in a blasting area, or in areas posted: "Turn off two-way radio." Obey all signs and instructions.
~11~                                     U3 Radio Safety Booklet English Version Operational Cautions Intrinsically Safe Radio Information The Intrinsically safe approval unit refers to a product that has been approved as intrinsically safe by an approval agency (for example FM Approvals, CSA, UL, or Cenelec) and certifies that a particular product meets the Agency's applicable intrinsic safety standards for specific types of hazardous classified locations. A portable radio that has been approved for intrinsic safety will have Approval label attached to the radio to identify the unit as being approved for specified hazardous atmospheres. This label specifies the hazardous Class/Division/Group along with the part number of the battery that must be used. The Intrinsically Safe Approval Antennas •  Do not use any portable radio that has a damaged antenna. If a damaged antenna comes into contact with your skin, a minor burn can result. •  Do not hold onto the antenna when the radio is powered on. Always keep the antenna at least 0.5 inches (1.9 cm) away from the body and 1 inch (2.54 cm) from the face when transmitting to ensure FCC RF exposure compliance requirements are not exceeded.   Batteries All batteries can cause property damage and/or bodily injury, such as burns, if a conductive material such as jewelry, keys, or beaded chains touches exposed terminals. The conductive material may complete an electrical circuit (short circuit) and become quite hot. Exercise care in handling any charged battery, particularly when placing it inside a pocket, purse, or other container with metal objects.
~12~                                     U3 Radio Safety Booklet English Version Label will be located on the portable radio unit. Operational Cautions for Intrinsic Safe Equipment Warnings for Radios Approved as Intrinsically Safe Radios must ship from the Unication manufacturing facility with the hazardous atmosphere capability and the intrinsic safety approval labeling (FM, UL, CSA, CENELEC). Radios will not be upgraded to this capability and labeled once they have been shipped to the field. A modification changes the unit’s hardware from its original design configuration. Modifications can only be made by the original product manufacturer. •  Do not operate radio communications equipment in a hazardous atmosphere unless it is a type especially qualified (for example, FM, UL, CSA, or CENELEC approved). An explosion or fire may result.  •  Do not operate a radio unit that has been approved as intrinsically safe product in a hazardous atmosphere if it has been physically damaged (for example, cracked housing). An explosion or fire may result.  •  Do not replace or charge batteries in a hazardous atmosphere. Contact sparking may occur while installing or removing batteries and cause an explosion or fire.
~13~                                     U3 Radio Safety Booklet English Version                          •  Do not replace or change accessories in a hazardous atmosphere. Contact sparking may occur while installing or removing accessories and cause an explosion or fire. •  Turn the radio off before removing or installing a battery or accessory. •  Do not disassemble an intrinsically safe product in any way that exposes the internal circuits of the unit. •  Failure to use an intrinsically safe approved battery or Approved accessories specifically approved for the radio unit may result in the dangerously unsafe condition of an unapproved radio combination being used in a hazardous location. •  Unauthorized or incorrect modification of the intrinsically safe approved Product will negate the approval rating of the product. •  Incorrect repair or relabeling of any intrinsically safe Agency approved radio could adversely affect the Approval rating of the unit. •  Use of a radio that is not intrinsically safe in a hazardous atmosphere could result in serious injury or death.
~14~                                     U3 Radio Safety Booklet English Version  Repair  A repair constitutes something done internally to the unit that would bring it back to its original condition. Items not considered as repairs are those in which an action is performed on a unit which does not require the outer casing of the unit to be opened in a manner that exposes the internal electrical circuits of the unit.  Do Not Substitute Options or Accessories The Unication communications equipment certified as intrinsically safe by the approving agency, (FM, UL, CSA, CENELEC) is tested as a complete system which consists of the listed agency Approved portable, Approved battery, and Approved accessories or options, or both. This Approved portable and battery combination must be strictly observed. There must be no substitution of items, even if the substitute has been previously Approved with a different Unication communications equipment unit. Approved configurations are listed by the Approving Agency (FM, UL, CSA, CENELEC).     REPAIRS FOR UNICATION PRODUCTS WITH INTRINSICALLY SAFE APPROVAL ARE THE RESPONSIBILITY OF THE USER. Repairs to a Unication FM approved radio product should only be done at a location that has been FM audited under the FM 3605 repairs and service standard. Contact Unication for assistance regarding repairs and service of Unication intrinsically safe equipment.
~15~                                     U3 Radio Safety Booklet English Version The Intrinsically Safe Approval Label affixed to radio refers to the intrinsically safe classification of that radio product, and the approved batteries that can be used with that system.   The manual PN referenced on the Intrinsically Safe Approval Label identifies the approved Accessories and or options that can be used with that portable radio unit. Using a non Unication intrinsically safe battery and or accessory with the Unication approved radio unit will void the intrinsically safe approval of that radio unit. 
~16~                                     U3 Radio Safety Booklet English Version •  CorporateHeadquarters•  DallasOffice©2010UnicationCo.,Ltd.Email:salesenquiry@uni.com.twUnicationCo.,Ltd.Tel.:+886‐2‐2299‐9678Address:5F.,No.6,Wu‐Kung5Rd.,HsinchuangCity,Taipei,TaiwanUnicationUSAInc.Tel.:+1‐817‐303‐9320Address:1901E.LamarBlvd.,Arlington,TX76006,U.S.A.Email:sales@unication.comUnicationLogo,Unication,U3LogoandtheU3aretrademarksorregisteredtrademarksofUnication.

Navigation menu