Uniden Bc72Xlt Owners Manual BC72 Paper OM
Uniden-Bc72Xlt-Users-Manual-360176 uniden-bc72xlt-users-manual-360176
PDF Uniden_BC72XLT VHF-UHF Scanner_Manual T E X T F I L E S
Uniden_BC72XLT VHF-UHF Scanner_Manual Uniden_BC72XLT VHF-UHF Scanner_Manual
BC72XLT to the manual dc43862b-fde8-4682-845e-d58a0464645d
2015-05-27
: Uniden Uniden-Bc72Xlt-Owners-Manual-725517 uniden-bc72xlt-owners-manual-725517 uniden pdf
Open the PDF directly: View PDF .
Page Count: 64
Download | |
Open PDF In Browser | View PDF |
BC72 Paper OM.fm Page 1 Monday, October 25, 2004 3:11 PM BC72XLT OWNER’S MANUAL OWNER’S MANUAL BC72 Paper OM.fm Page 2 Monday, October 25, 2004 3:11 PM Precautions Before you use this scanner, please read and Precautions observe the following. IMPORTANT! This scanning radio has been manufactured so that it will not tune to the radio frequencies assigned by the FCC for cellular telephone usage. The Electronic Communications Privacy Act of 1986, as amended, makes it a federal crime to intentionally intercept cellular or cordless telephone transmissions or to market this radio when altered to receive them. The installation, possession, or use of this scanning radio in a motor vehicle may be prohibited, regulated, or require a permit in certain states, cities, and/or local jurisdictions. Your local law enforcement officials should be able to provide you with information regarding the laws in your community. Changes or modifications to this product not expressly approved by Uniden, or operation of this product in any way other than as detailed by this Operating Guide, could void your authority to operate this product. EARPHONE WARNING! Be sure to use only a monaural earphone with this scanner. You can also use an optional mono headset. Use of an incorrect earphone or mono headset might be potentially hazardous to your hearing. The output of the phone jack is monaural, but you will hear it in both headphones of a stereo headset. Set the volume to a comfortable audio level coming from the speaker before plugging in the monaural earphone or headset. Otherwise, you might experience some discomfort or possible hearing Precautions 2 BC72 Paper OM.fm Page 3 Monday, October 25, 2004 3:11 PM damage if the volume suddenly becomes too loud because of the volume control or squelch control setting. This might be particularly true of the type of earphone that is placed in the ear canal. WARNING! Uniden does not represent this unit to be waterproof. To reduce the risk of fire or electrical shock, do not expose this unit to rain or moisture. Uniden® and Bearcat® are registered trademarks of Uniden America Corporation. Close CallTM is a trademark of Uniden America Corporation. Other trademarks used throughout this manual are the property of their respective holders. Precautions 3 BC72 Paper OM.fm Page 4 Monday, October 25, 2004 3:11 PM BC72XLT Controls and Display BC72XLT Controls and Display Headphone Jack Squelch Volume Display Keypad DC 6V Jack Power BC72XLT Controls and Display 4 BC72 Paper OM.fm Page 5 Monday, October 25, 2004 3:11 PM Contents Contents The FCC Wants You To Know ............................. 7 Scanning Legally .............................................. 7 Introduction ........................................................... 9 Feature Highlights ............................................... 11 About This Manual ......................................... 12 Understanding Scanning .................................... 14 What is Scanning? ......................................... 14 What is Searching? ........................................ 14 Conventional Scanning ................................... 14 Where To Obtain More Information ............... 16 Included With Your Scanner ............................... 18 Setting Up Your Scanner .................................... 19 Using Internal Batteries .................................. 19 Using AC Power ............................................. 23 Connecting the Antenna ................................ 23 Connecting an Earphone/Headphone ............ 24 Connecting an Extension Speaker ................. 24 Attaching the Belt Clip .................................... 25 About Your Scanner ........................................... 26 A Look At The Keypad ................................... 27 A Look At The Display ................................... 30 Understanding Banks ..................................... 32 Operation ............................................................ 33 Turning On The Scanner and Setting Squelch .............................................. 33 Storing Known Frequencies Into Channels .... 33 Searching For and Temporarily Storing Active Frequencies ............................ 34 Scanning the Stored Channels ...................... 35 Manually Selecting a Channel ....................... 36 Special Features ................................................. 37 Close CallTM RF Capture Technology ............ 37 Chain Search ................................................. 41 Direct Entry Search ........................................ 43 Search Skip Memory ...................................... 45 Delay .............................................................. 46 Turning Channel-Storage Banks On and Off ..................................................... 47 Contents 5 BC72 Paper OM.fm Page 6 Monday, October 25, 2004 3:11 PM Locking Out Channels .................................... Priority ............................................................ Using Keylock ................................................ Using the Display Backlight ........................... Troubleshooting .................................................. Resetting the Scanner ................................... Care and Maintenance ....................................... General Use ................................................... Location ......................................................... Cleaning ......................................................... Repairs........................................................... Birdies ............................................................ Specifications...................................................... Optional Accessories .......................................... One-Year Limited Warranty ................................. 48 48 49 50 51 53 54 54 54 54 55 55 56 59 60 Contents 6 BC72 Paper OM.fm Page 7 Monday, October 25, 2004 3:11 PM The FCC Wants You To Know The FCC Wants You To Know This scanner has been tested and found to comply with the limits for a scanning receiver, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This scanner generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this scanner does cause harmful interference to radio or television reception, which can be determined by turning the scanner on and off, you are encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the scanner and the receiver This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Scanning Legally Your scanner covers frequencies used by many different groups, including police and fire departments, ambulance services, government agencies, private companies, amateur radio services, military operations, pager services, and wireline (telephone and telegraph) service providers. It is legal to listen to almost every transmission your scanner can receive. The FCC Wants You To Know 7 BC72 Paper OM.fm Page 8 Monday, October 25, 2004 3:11 PM However, there are some transmissions that you should never intentionally listen to. These include: • Telephone conversations (cellular, cordless, or other private means of telephone signal transmission) • Pager transmissions • Any scrambled or encrypted transmissions According to the Electronic Communications Privacy Act (ECPA), you are subject to fines and possible imprisonment for intentionally listening to, using, or divulging the contents of such a conversation unless you have the consent of a party to the conversation (unless such activity is otherwise illegal). This scanner has been designed to prevent the reception of cellular telephone transmissions and the decoding of scrambled transmissions. This is done to comply with the legal requirement that scanners be manufactured so they are not easy to modify to pick up these transmissions. Do not open your scanner’s case to make any modifications that could allow it to pick up transmissions that are illegal to monitor. Modifying or tampering with your scanner’s internal components or using it in a way other than as described in this manual could invalidate your warranty and void your FCC authorization to operate it. In some areas, mobile use of this scanner is unlawful or requires a permit. Check the laws in your area. It is also illegal in many areas (and a bad idea everywhere) to interfere with the duties of public safety officials by traveling to the scene of an incident without authorization. The FCC Wants You To Know 8 BC72 Paper OM.fm Page 9 Monday, October 25, 2004 3:11 PM Introduction Introduction Thank you for purchasing a Uniden BC72XLT Handheld Scanner. The scanner is versatile, compact, and easy to use. In addition to its standard scanning features, your scanner also includes Close CallTM RF capture technology designed to help you detect and identify strong local radio signals in your area. You can program up to 100 frequencies into the scanner's memory. The scanner lets you scan transmissions and is preprogrammed with service banks for your convenience. You can quickly search those frequencies most commonly used by police and other agencies, without tedious and complicated programming. The scanner gives you direct access to over 32,000 exciting frequencies. Use your scanner to monitor: • Police and fire departments (including rescue and paramedics) • NOAA weather transmissions • Business/Industrial radio • Utilities • Marine and amateur (ham radio) bands • Air band Introduction 9 BC72 Paper OM.fm Page 10 Monday, October 25, 2004 3:11 PM This table lists the frequency ranges, default frequency step, default mode (AM or FM), and type of transmissions you can hear for each range. Frequency Range Step Mode Transmission (MHz) (kHz) 25.0-27.995 5 AM Citizens Band/ Business Band 28.0-29.695 5 FM 10 Meter Amateur Band 29.7-49.995 5 FM VHF Low Band 50.0-54.0 5 FM 6 Meter Amateur Band 108.0-136.9875 12.5 AM Aircraft Band 137.0-143.995 5 FM Military Band 144.0-147.995 5 FM 2 Meter Amateur Band 148.0-174.0 5 FM VHF High Band, Federal Government 406.0-419.99375 6.25 FM Federal Land Mobile 420.0-449.99375 6.25 FM 70cm Amateur Band 450.0-469.99375 6.25 FM UHF Standard Band 470.0-512.0 6.25 FM UHF TV Band Introduction 10 BC72 Paper OM.fm Page 11 Monday, October 25, 2004 3:11 PM Feature Highlights Feature Highlights Close CallTM RF Capture Technology - you can set the scanner so it detects and provides information about nearby radio transmissions. See “Close CallTM RF Capture Technology” on Page 37 for more information. Pager Screen - lets you set the scanner so it does not detect pager frequencies during Close Call search. Chain Search - lets you enter personal search bands in 10 locations and search all locations in a chain of frequency bands. Triple-Conversion Circuitry - virtually eliminates any interference from IF (intermediate frequency) images, so you hear only the selected frequency. Channel-Storage Banks - the scanner has 10 banks. You can store up to 10 frequencies into each bank (for a total of 100 frequencies), so you can more easily identify calls. Two-Second Scan Delay - delays scanning for about 2 seconds before moving to another channel, so you can hear more replies that are made on the same channel. Lock-Out Function - lets you set your scanner to skip over specified channels or frequencies when scanning or searching. Priority Channels - lets you program one channel in each bank (10 in all) and then have the scanner check that channel every 2 seconds while it scans the bank, so you do not miss transmissions on those channels. Six Service Banks - frequencies are preset in separate police, Fire/emergency, aircraft, ham, marine, and weather banks, to make it easy to locate specific types of calls. Feature Highlights 11 BC72 Paper OM.fm Page 12 Monday, October 25, 2004 3:11 PM Key Lock - lets you lock the scanner's keys to help prevent accidental changes to the scanner's programming. Direct Access - lets you directly access any channel. Display Backlight - makes the scanner easy to read in low-light situations. Flexible Antenna with BNC Connector - provides adequate reception in strong signal areas and is designed to help prevent antenna breakage. Or, you can connect an external antenna for better reception. Memory Backup - keeps the frequencies stored in memory for an extended time if the scanner loses power. Two Power Options - let you power the scanner using internal batteries or external AC power using the included AC adapter. Key Confirmation Tones - the scanner sounds a tone when you perform an operation correctly, and an error tone if you make an error. Battery Low Alert - warns you when battery power gets low. About This Manual The screen displays used in this manual are representations of what might appear when you use your scanner. Since what you see depends on the frequencies for your area and the settings you select, you might notice some differences between what is in this manual and what appears on your scanner. Feature Highlights 12 BC72 Paper OM.fm Page 13 Monday, October 25, 2004 3:11 PM To get the most from this manual, review the contents to become familiar with the basic functions available. If you are new to scanning, be sure to read “Understanding Scanning” on Page 14 for a quick background on the technology behind the hobby. The first thing you’ll need to do is install batteries in the scanner. Then you need to connect the included antenna to the scanner. See “Using Internal Batteries” on Page 19 and “Connecting the Antenna” on Page 23 if you need any help doing this. Feature Highlights 13 BC72 Paper OM.fm Page 14 Monday, October 25, 2004 3:11 PM Understanding Scanning This section providesScanning you with background on how Understanding scanning works. You don’t really need to know all of this to use your scanner, but some background knowledge will help you get the most from your BC72XLT. What is Scanning? Unlike standard AM or FM radio stations, most twoway communications do not transmit continuously. Your BC72XLT scans programmed channels until it finds an active frequency, then stops on that frequency and remains on that channel as long as the transmission continues. When the transmission ends, the scanning cycle resumes until the scanner receives another transmission. What is Searching? The BC72XLT can search for active frequencies. This is different from scanning because you are searching for frequencies that have not been programmed into the scanner. When you select frequency bands to search, the scanner searches for any active frequency within the lower and upper limits you specify. When the scanner finds an active frequency, it stops on that frequency as long as the transmission lasts. If you think the frequency is interesting, you can program it into one of the banks. If not, you can continue to search. Conventional Scanning Conventional scanning is a relatively simple concept. Each group of users in a conventional system is assigned a single frequency (for simplex systems) or two frequencies (for repeater systems). Any time one of them transmits, their transmission always goes out on the same frequency. Up until the late 1980’s Understanding Scanning 14 BC72 Paper OM.fm Page 15 Monday, October 25, 2004 3:11 PM this was the primary way that radio systems operated. Even today, there are many 2-way radio users who operate using a conventional system: • • • • • Aircraft Amateur radio FRS/GMRS users Broadcast AM/FM/TV stations Many business radio users When you want to store a conventional system, all you need to know is the frequencies they operate on. When you are scanning a conventional system, the scanner stops very briefly on each channel to see if there is activity. If there isn’t, the scanner quickly moves to the next channel. If there is, then the scanner pauses on the transmission until it is over. Simplex Operation Simplex systems use a single frequency for both transmit and receive. Most radios using this type of operation are limited to line-of-sight operation. This type of radio is frequently used at construction job sites, and with inexpensive consumer radios such as GMRS/FRS radios. The range is typically 1-8 miles, depending upon the terrain and many other factors. Repeater Operation Repeater systems use two frequencies: one transmits from the radio to a central repeater; the other transmits from the repeater to other radios in the system. With a repeater-based system, the repeater is located on top of a tall building or on a radio tower that provides great visibility to the area of operation. When a user transmits (on an input frequency), the signal is picked up by the repeater and retransmitted (on an output frequency). The user’s radios always Understanding Scanning 15 BC72 Paper OM.fm Page 16 Monday, October 25, 2004 3:11 PM listen for activity on the output frequency and transmit on the input frequency. Since the repeater is located very high, there is a very large line of sight. Typical repeater systems provide coverage out to about a 25-mile radius from the repeater location. Where To Obtain More Information By itself, this manual really only provides part of what you need to know to have fun scanning – how to program and use the scanner. The included conventional frequency guide will give you a good head start on the other part of what you need to know – what frequencies have interesting content. Information On The Internet The Internet is a great source for current frequencies and information about scanning. Many web sites have lists of frequencies for your area. You can use a search engine to find and use them. Make a list of the agencies you want to listen to, then look up the frequencies and systems used by those agencies. Here are a few useful sites: • http://www.scannermaster.com * - frequency resources and home of Police Call. You can also call them at 1 800 SCANNER (hours are from 9:00 a.m. to 5:30 p.m. Eastern Time Monday through Friday). • http://www.radioreference.com * - the Internet's premier source for user-supported radio system information. • http://www.bearcat1.com - frequency information from National Communications. Understanding Scanning 16 BC72 Paper OM.fm Page 17 Monday, October 25, 2004 3:11 PM • svartifoss2.fcc.gov/reports/index.cfm * conventional frequency information on file with the US Government * - This web site is not affiliated with Uniden Corporation. To purchase another copy of the conventional frequency guide, contact your local dealer or: Uniden Parts Department (800) 554-3988 (Hours are from 8:00 a.m. to 5:00 p.m.Central Time Monday through Friday.) For more information about Uniden and our other products, visit http://www.uniden.com. Understanding Scanning 17 BC72 Paper OM.fm Page 18 Monday, October 25, 2004 3:11 PM Included With Your Scanner Included With Your Scanner Antenna AC Adapter Belt Clip Scanner BC72 OWNER’S MANUAL OWNER’S MANUAL Frequency Guide Owners Manual If any of these items are missing or damaged, immediately contact your place of purchase or Uniden Customer Service at: (800) 297-1023, 7:00 a.m. to 7:00 p.m., Central, Monday through Friday. Setting Up Your Scanner Included With Your Scanner 18 BC72 Paper OM.fm Page 19 Monday, October 25, 2004 3:11 PM Setting Up Your Scanner These guidelines will help you install and use your new scanner: • If your scanner receives interference or electrical noise, move the scanner or its antenna away from the source. You might also try changing the height or angle of the telescoping antenna. • To improve the scanner’s reception, use an optional external antenna designed for multiband coverage. (You can purchase this type of antenna at a local electronics store). If the optional antenna has no cable, use 50-70 ohm coaxial cable for lead-in. A mating plug might be necessary for the optional antennas. • Use an optional mono earphone or mono headset with proper impedance for private listening. Read the precautions on the inside front cover of this Owners Manual. • Do not use the scanner in high-moisture environments such as the kitchen or bathroom. • Avoid placing the scanner in direct sunlight or near heating elements or vents. Using Internal Batteries You can power your scanner using two alkaline or rechargeable AA batteries (not supplied). Using Non-Rechargeable Batteries 1. Make sure the power is turned off. 2. Slide the battery compartment cover. 3. Before you install alkaline or any other nonrechargeable batteries, use a pointed object such as a ballpoint pen to set REG. ALK. BATT./ NI-MH BATT. inside the compartment to REG. ALK. BATT.. Setting Up Your Scanner 19 BC72 Paper OM.fm Page 20 Monday, October 25, 2004 3:11 PM WARNING! Set REG. ALK. BATT./NI-MH BATT. to NI-MH BATT. only if you are using rechargeable batteries. Never attempt to recharge non-rechargeable batteries. Non-rechargeable batteries can get hot or burst if you try to recharge them. 4. Install two batteries in the compartment as indicated by the polarity symbols (+ and -) marked inside. Setting Up Your Scanner 20 BC72 Paper OM.fm Page 21 Monday, October 25, 2004 3:11 PM Cautions: • Use only fresh batteries of the required size and recommended type. • Always remove old or weak batteries. Batteries can leak chemicals that destroy electronic circuits. • Do not mix old and new batteries, different types of batteries (standard, alkaline, or rechargeable), or rechargeable batteries of different capacities. 5. Replace the cover. 6. When flashes and the scanner beeps every 15 seconds, replace both batteries. Using Rechargeable Batteries You can also use two rechargeable batteries to power your scanner. Before you use Ni-MH or Ni-Cd batteries, you must charge them. The scanner has a built-in circuit that lets you recharge Ni-MH or Ni-Cd batteries while they are in the scanner. To charge the batteries, set REG. ALK. BATT./NI-MH BATT. inside the battery compartment to NI-MH BATT., install the batteries in the scanner, and connect an external AC adapter to the scanner's DC 6V jack (see “Using AC Power” on Page 23). Setting Up Your Scanner 21 BC72 Paper OM.fm Page 22 Monday, October 25, 2004 3:11 PM WARNING! Do not connect either adapter to the scanner if nonrechargeable batteries (such as alkaline batteries) are installed in the scanner and REG. ALK. BATT./NI-MH BATT. is set to NI-MH BATT., or if you are unsure of the switch’s position. Non-rechargeable batteries will get hot and can even burst if you try to recharge them. Before you use Ni-MH or Ni-Cd batteries for the first time, charge them for 14 hours to bring them to a full charge. Discharged batteries take about 14 hours to fully recharge. Notes: • The scanner might test rechargeable batteries when you install them. TSt CHArg and appear. If the batteries are good, TSt disappears and the scanner charges the batteries. Otherwise, no bAtt appears and the scanner does not charge the batteries. • Ni-MH batteries last longer and deliver more power if you occasionally let them fully discharge. To do this, simply use the scanner until it beeps every 15 seconds and flashes. • To prevent damage to Ni-MH batteries, never charge them in an area where the temperature is above 113°F (45°C) or below 40°F (4°C). • If you connect an external power source to the scanner with REG. ALK. BATT./NI-MH BATT. set to REG. ALK. BATT., CHArg and appear but the scanner does NOT charge the batteries. Make sure that you use the correct batteries and set REG. ALK. BATT./ NI-MH BATT. to the correct position when you connect an external power source. Setting Up Your Scanner 22 BC72 Paper OM.fm Page 23 Monday, October 25, 2004 3:11 PM • For longer operation, you can also use highcapacity Ni-MH batteries to power the scanner. This type of battery takes longer to recharge. You can get high-capacity Ni-MH batteries at your local electronics store. Using AC Power You can power the scanner using the supplied 6V, 500 mA AC adapter. To use the scanner on AC power, plug the AC adapter into DC 6V on the side of the scanner then plug the other end into a standard AC outlet. If rechargeable batteries are installed and REG. ALK. BATT./NI-MH BATT. is set to NI-MH BATT., the adapter powers the scanner and recharges the installed batteries at the same time. Connecting the Antenna To attach the supplied flexible antenna to the connector on the top of your scanner, align the slots around the antenna's connector with the tabs on the scanner's BNC connector. Then slide the antenna's connector down over the scanner's connector and rotate the antenna connector's outer ring clockwise until it locks into place. Setting Up Your Scanner 23 BC72 Paper OM.fm Page 24 Monday, October 25, 2004 3:11 PM Connecting an Optional Antenna The scanner's BNC connector makes it easy to connect a variety of optional antennas, including an external mobile antenna or outdoor base station antenna. Note: Always use 50-ohm, RG-58, or RG-8, coaxial cable to connect an outdoor antenna. If the antenna is over 50 feet from the scanner, use RG-8 low-loss dielectric coaxial cable. You can get a BNC adapter at your local electronics store. Connecting an Earphone/Headphone BC72XLT For private listening, you can plug a 1/8-inch (3.5 mm) mini-plug earphone or mono headphones (not supplied) into the headphone jack on top of your scanner. This automatically disconnects the internal speaker. Connecting an Extension Speaker In a noisy area, an optional extension speaker, positioned in the right place, might provide more comfortable listening. Plug the speaker cable's 1/8inch (3.5-mm) mini-plug into your scanner's jack. WARNING! If you connect an external speaker to the scanner's headphone jack, never connect the audio output line to a power supply and ground. This might damage the scanner. Setting Up Your Scanner 24 BC72 Paper OM.fm Page 25 Monday, October 25, 2004 3:11 PM Attaching the Belt Clip To make your scanner easier to carry when you are on the go, use the supplied belt clip. Use a Phillips screwdriver and the supplied screws to attach the clip to the scanner. Setting Up Your Scanner 25 BC72 Paper OM.fm Page 26 Monday, October 25, 2004 3:11 PM About Your Scanner We use aYour few simple terms in this manual to explain About Scanner the features of the scanner. Familiarize yourself with these terms and the scanner's features, and you can put the scanner to work for you right away. Simply determine the type of communications you want to receive, then set the scanner to scan those communications. A frequency, expressed in kHz or MHz, is the tuning location of a station. To find active frequencies, you use the search function or refer to a frequency reference. Besides searching within a selected frequency range, you can also search your scanner's service banks. Service banks are preset groups of frequencies categorized by the type of services that use those frequencies. For example, many amateur radio frequencies are located in the HAM service bank. When you search and find a desired frequency, you can store it into a programmable memory location called a channel. Channels are grouped into channel-storage banks. The scanner has 10 channel-storage banks and each bank has 10 channels. You can scan the channel-storage banks to see if there is activity on the frequencies stored there. About Your Scanner 26 BC72 Paper OM.fm Page 27 Monday, October 25, 2004 3:11 PM A Look At The Keypad Your scanner's keys have various functions labeled on the key tops and below the keys. To select the function labeled on a key, simply press the key. To select the function labeled below a key, first press Func then release it. F appears on the display. Then press the next key in the function key sequence while F appears. F appears or disappears as you press Func. If your scanner's keys seem confusing at first, the following information should help you understand each key's function. Key Name Description Hold/ Hold – Holds the scan or the frequency search. Press and hold Hold to increment channels continuously. Func + – Switches between the three Close Call modes. About Your Scanner 27 BC72 Paper OM.fm Page 28 Monday, October 25, 2004 3:11 PM Key Name Description Scan/Src Scan – Scans the stored channels. Func + Src – Starts chain search or resumes searching. / – Turns the display backlight on or off. Func + – Locks and unlocks the keypad. Func Lets you use various functions by pressing this key in combination with other keys. Press and hold for more than 2 seconds to turn the scanner on or off. 1/Pri 1 – Enters a 1. Func + Pri – Sets and turns the priority function on or off. 2/ 2 – Enters a 2. Func + – Selects the scan or search direction. 3/Svc 3 – Enters a 3. Func + Svc – Sets and turns the service search function on. 4 4 – Enters a 4. About Your Scanner 28 BC72 Paper OM.fm Page 29 Monday, October 25, 2004 3:11 PM Key Name Description 5/Dly 5 – Enters a 5. Func + Dly – Sets and turns the delay function on or off. 6/PSrc 6 – Enters a 6. Func + PSrc – Sets and turns program band select mode on or off. 7 7 – Enters a 7. 8/ 8 – Enters an 8. Func + – Selects the scan or search direction. 9 Enters a 9. /Clr 0/L/O Enters a decimal point. 0 – Enters a 0. Func + L/O – Lets you lock out a selected channel or skip a specified frequency. E/Pgm E – Enters frequencies into channels. Func + Pgm – lets you program the frequency. About Your Scanner 29 BC72 Paper OM.fm Page 30 Monday, October 25, 2004 3:11 PM A Look At The Display The display has indicators that show the scanner's current operating status. The display information helps you understand how your scanner operates. BANK - appears with numbers (1-10). - appears when you lock the keypad. F - appears only when the function mode is on. PGM - appears while you store a frequency into a channel. SRCH - appears during search mode. or - appears during search mode. - appears while rechargeable batteries are charging and alerts you when the battery power gets low. - appears when the scanner is set to a Close Call mode. P - appears when you select a priority channel. About Your Scanner 30 BC72 Paper OM.fm Page 31 Monday, October 25, 2004 3:11 PM SCN - appears when you scan channels. HOLD - appears during scan hold mode and search hold mode. L/O - appears when you manually select a channel you locked out or a skip frequency. DLY - appears when you select a delay. PRI - appears when the priority feature is turned on. HAM, WX, POL, FIRE, AIR, or MRN - appears along with an indicator that shows the current service bank during a service search. ALT - appears when you receive a Close Call alert while the Close Call function is on. About Your Scanner 31 BC72 Paper OM.fm Page 32 Monday, October 25, 2004 3:11 PM Understanding Banks Service Banks The scanner is preprogrammed with all the frequencies allocated to the weather, ham, marine, aircraft, police, and fire services. Channel-Storage Banks To make it easier to identify and select the channels you want to listen to, the 100 channels are divided into 10 channel-storage banks. Each bank has 10 channels. Use each channel-storage bank to group frequencies, such as those for the police department, fire department, ambulance services, or aircraft. For example, the police department might use four frequencies in your town while the fire department uses an additional four. You could program the four police frequencies starting with Channel 1 (the first channel in bank 1), and program the fire department frequencies starting with Channel 11 (the first channel in bank 2). About Your Scanner 32 BC72 Paper OM.fm Page 33 Monday, October 25, 2004 3:11 PM Operation Operation Turning On The Scanner and Setting Squelch Note: Make sure the scanner's antenna is connected before you turn it on. 1. Turn Squelch fully counterclockwise. 2. Press and hold for about 2 seconds to turn the scanner on, then turn Volume clockwise until you hear a hissing sound. 3. If the scanner is scanning, press Hold to stop scanning, then turn Squelch clockwise until the hissing stops. Storing Known Frequencies Into Channels 1. Press Hold. Then enter the channel number where you want to store a frequency, then press Func and Pgm. The channel number appears. 2. Use the number keys and to enter the frequency (including the decimal point) you want to store. 3. Press E to store the frequency into the channel. Notes: • If you entered an invalid frequency in Step 2, Error appears and the scanner beeps three times. Enter a valid frequency. • The scanner automatically rounds the entered number to the nearest valid frequency. For example, if you enter 151.473 (MHz), your scanner accepts it as 151.475. • When you enter a frequency into a channel, the scanner automatically turns on the delay function and DLY appears. When delay is turned on, the scanner automatically pauses scanning Operation 33 BC72 Paper OM.fm Page 34 Monday, October 25, 2004 3:11 PM 2 seconds after the end of a transmission before scanning proceeds to the next channel. To turn the function off or on, press Func + Dly. • If you enter a frequency that has already been entered elsewhere, the scanner sounds an error tone and displays the channel that was duplicated. If you entered the frequency by mistake, press then enter the correct frequency. To enter the frequency anyway, press E to accept. 4. To program the next channel in sequence, press E then repeat Steps 2 and 3. Searching For and Temporarily Storing Active Frequencies If you do not have a reference to frequencies in your area, use a search (except weather service search) to find a transmission. Note: When the scanner starts searching, it automatically turns on the delay function. To turn delay on or off, press Func + Dly. Service Search You can search for weather, ham, marine, aircraft, police, or fire transmissions without knowing the specific frequencies used in your area. The scanner is preprogrammed with all the frequencies allocated to these services. To use this feature, press Func and Svc. SRCH appears and the scanner searches starting with the weather service bank. To select a different service bank, repeatedly press Func and Svc. Service mode appears on the display. When the scanner stops on a transmission, press Hold to stop searching and listen to the transmission. Hold appears. In this mode, you can Operation 34 BC72 Paper OM.fm Page 35 Monday, October 25, 2004 3:11 PM press Func + frequencies. or Func + to step through the To release the hold and continue searching, press Hold. Or, if you did not press Hold, simply press Func + or Func + to continue searching. Note: Because there are many different frequencies allocated to fire and police departments, it can take several minutes to search all the service frequencies. Storing Frequencies into Channels During Service Search You can store frequencies you found during service search or service search hold mode into channels. 1. Press Func and Pgm during service search or service search hold mode. The frequency and the lowest blank channel alternately appear. 2. Press E to store the frequency into the blank channel. If you want to select another channel, press Func + or Func + before you press E. You can also use the 0-9 key to select the bank. If you entered a frequency that has already been entered elsewhere, the scanner sounds an error tone and displays the channel that was duplicated. If you entered the frequency by mistake, press then enter the correct frequency. To enter the frequency anyway, press E to accept. Scanning the Stored Channels To begin scanning channels, press Scan. The scanner scans through all non-locked channels in the activated banks. (See “Locking Out Channels” on Page 48 and “Turning Channel-Storage Banks On and Off” on Page 47). When the scanner finds a Operation 35 BC72 Paper OM.fm Page 36 Monday, October 25, 2004 3:11 PM transmission, it stops on it. When the transmission ends, the scanner resumes scanning. Notes: • If you have not stored frequencies into any channels, the scanner does not scan. • If the scanner picks up unwanted partial, or very weak transmissions, turn Squelch clockwise to decrease the scanner's sensitivity to these signals. To listen to a weak or distant station, turn Squelch counterclockwise. • To ensure proper scanning, adjust Squelch until the audio mutes. Manually Selecting a Channel You can continuously monitor a single channel without scanning. This is useful if you hear an emergency broadcast on a channel and do not want to miss any details - even though there might be periods of silence - or if you want to monitor a specific channel. To manually select a channel, press Hold, enter the channel number then press Hold again. Or, during scanning, if the radio stops at a channel you want to listen to, press Hold once. (Repeatedly pressing Hold at this time causes the scanner to step through the channels.) Press Scan to resume automatic scanning. Operation 36 BC72 Paper OM.fm Page 37 Monday, October 25, 2004 3:11 PM Special Features TM RF Capture Technology SpecialCall Features Close Your scanner's Close Call feature lets you set the scanner so it detects then displays the frequency of a nearby strong radio transmission. Close Call RF capture works great for finding frequencies at venues such as malls and sporting events. You can set the scanner so Close Call detection works "in the background" while you are scanning other frequencies, turn off normal scanning while Close Call is working, or turn off the Close Call feature and use the scanner normally. You can set the scanner so it alerts you when the Close Call feature detects a frequency. You can also set the frequency band where you want the scanner to look for transmissions. Unlike searching, which requires the scanner to tune to a frequency to check for a transmission, Close Call RF capture directly detects the presence of a strong, nearby signal and instantly tunes to the source’s frequency. Notes: • Close Call RF capture works well for locating the source of strong local transmissions such as mobile and handheld two-way radios in areas with no other strong transmission sources. However, if you are in an area with many transmission sources (such as pager radio transmitters, multi-use radio towers, traffic control devices, etc.), Close Call RF capture might not find the transmission you are searching for, or it might find a transmission other than the one you are searching for. • Close Call RF capture cannot detect satellite dishes or any transmitter with a frequency above or below the frequency ranges listed under “Setting the Close Call Options” on Page 38. Special Features 37 BC72 Paper OM.fm Page 38 Monday, October 25, 2004 3:11 PM • Close Call works better with some types of transmissions than others. It might not correctly display frequency information for transmitters using a highly directive antenna (such as an amateur radio beam antenna), if there are many transmitters operating at the same time in the same area, or if the transmitter is a broadcast television station. Setting the Close Call Options 1. Press Func then press and hold for 2 seconds. One of the following Close Call options appears. C-C.bnd: Lets you select the Close Call band. C-C.ALt: Lets you select the Close Call alert settings. C-C.PS: Lets you turn Pager Screen on or off. Pager Screen lets you set the scanner so it does not detect pager frequencies. 2. Repeatedly press or you want, then press E. to select the option If you selected C-C.bnd, one of the following band names appears. bnd Lo: VHF Low Band (25.0000 - 54.0000 MHz) bnd Air: AIR Low Band (108.0000 - 136.9875 MHz) bnd Hi: VHF High Band (137.0000 - 174.0000 MHz) bnd UHF: UHF Band (406.0000 - 512.0000 MHz) Special Features 38 BC72 Paper OM.fm Page 39 Monday, October 25, 2004 3:11 PM If you selected C-C.Alt, skip to Step 5. If you selected C-C.PS, skip to Step 7. 3. Repeatedly press or until the band you want to search appears, then press E to select it. Otherwise, press if you do not want to select it. The scanner displays the following options. Lo On or Lo OFF: Lets you select the VHF Lo frequency band. Air On or Air OFF: Lets you select the Air frequency band. Hi On or Hi OFF: Lets you select the VHF Hi frequency band. UHF On or UHF OFF: Lets you select the UHF frequency band. 4. Repeatedly press or until the option you want appears, then press E to select it. Otherwise, press if you do not want to select it. Then skip to Step 9. 5. Press E while C-C.Alt appears. One of the following alert options appears. ALt bEEP: The scanner beeps when a Close Call signal is detected. ALt Light: The scanner flashes the display backlight when a Close Call signal is detected. ALt bP-Lt: The scanner flashes the display backlight and beeps when a Close Call signal is detected. ALt OFF: The scanner does not provide any alert when a Close Call signal is detected. Special Features 39 BC72 Paper OM.fm Page 40 Monday, October 25, 2004 3:11 PM 6. Repeatedly press or until the option you want appears, then press E to select it. Otherwise, press if you do not want to select it. Then skip to Step 9. 7. Press E while C-C.PS appears. One of the following Pager Screen options appears. PS On: The scanner ignores hits on common pager frequencies. PS OFF: The scanner alerts you when it receives hits on common pager frequencies. 8. Repeatedly press or until the option you want appears, then press E to select it. 9. When you select the option, press Scan to start Close Call search. Otherwise, to continue normal scanning, repeatedly press Func until F disappears then press Scan. Using Close Call RF Capture To turn on the Close Call feature, press Func + once except in WX search, band select, or program mode. appears. Every 2 seconds, the scanner checks for frequencies in the range you specified in “Setting the Close Call Options” on Page 38. Notes: • Set the squelch tight (where only strong signals are received) while using Close Call. • To continue scanning normally while the Close Call feature is working, simply press Scan twice. When the scanner finds a frequency, it sounds the alert you specified in “Setting the Close Call Options” on Page 38, and Found flashes. Press any key to confirm the displayed frequency. Press Scan to resume scanning. Or press or while the frequency and F appear to select the band where you are searching. Special Features 40 BC72 Paper OM.fm Page 41 Monday, October 25, 2004 3:11 PM To turn on the Close Call feature and turn off normal scanning, press Func + twice. flashes. To turn off Close Call and turn on normal scanning, press Func + three times. disappears. Chain Search This feature lets you search through preset frequency ranges. You can also change each range to a range you set. There are three modes within this feature: chain search mode, chain search hold mode, and program band select mode. The preset frequency ranges are: Bank No. Frequency (MHz) Step (kHz) 1 25.0000-27.9950 5 2 28.0000-29.6950 5 3 29.7000-49.9950 5 4 50.0000-54.0000 5 5 137.0000-143.9950 5 6 144.0000-147.9950 5 7 406.0000-419.99375 6.25 8 420.0000-449.99375 6.25 9 450.0000-469.99375 6.25 10 470.0000-512.0000 6.25 Chain Search Mode Press Func + Src to start chain search mode. SRCH, the enabled search bank number, and or (indicating the search direction) appear. The search bank number being searched flashes. Special Features 41 BC72 Paper OM.fm Page 42 Monday, October 25, 2004 3:11 PM Press 0-9 to enable or disable the search bank number being searched in this mode. Enabled bank numbers appear. (Disabled bank numbers disappear). At least one search bank must be enabled. (The scanner sounds an error tone if you try to disable all the search banks). The search bank and the frequency where chain search starts depends on how the scanner was set before you selected chain search mode. Chain Search Hold Mode To start chain search hold mode, press Hold in chain search mode. The scanner stops searching and Hold appears. In this mode, pressing Func + changes the search direction downward and pressing Func + changes the search direction upward. or appears according to the current search direction. Storing Frequencies Found During Chain Search into Channel Memory You can store frequencies you find in chain search mode or chain search hold mode. 1. Press Func + Pgm in chain search mode or chain search hold mode. The lowest blank channel and bank appear. 2. Press E to store the frequency into the blank channel. To select another channel, press Func + or Func + before you press E. You can also press 0-9 to select the bank. If you try to save a frequency that is already stored, the scanner sounds an error tone and displays the channel that was duplicated. If you entered the frequency by mistake, press . To enter the frequency anyway, press E to accept. Special Features 42 BC72 Paper OM.fm Page 43 Monday, October 25, 2004 3:11 PM The scanner sets itself to program mode after you store a frequency. Setting the Search Range You can use this mode to define the search range used during a search in each search bank. To change a search range, press Func and PSrc. SRCH appears. Then select a search bank. When you select the search bank, the lower limit and upper limit frequency assigned in the search bank alternate on the display. To select another search bank, press Func + PSrc or Func + to increase the search bank number or Func + to decrease it. Hold down Func + or Func + for about 1 second to quickly move through the search bank numbers. After choosing the search bank, follow these steps to set the lower limit and upper limit frequency. 1. Enter the lower limit frequency by using the 0-9 and keys. 2. Press E to select the lower limit frequency. 3. Enter the upper limit frequency by using the 0-9 and keys. 4. Press E to select the upper limit frequency. Direct Entry Search You can use direct entry search to search up or down from the currently displayed frequency. 1. If the scanner is scanning or searching, press Hold. 2. Enter the frequency you want to start from by using the number keys. (Press to enter a decimal point). Special Features 43 BC72 Paper OM.fm Page 44 Monday, October 25, 2004 3:11 PM 3. Press Func + or Func + . The scanner searches, starting from the frequency you entered in Step 2. If you enter a frequency that is out of range, the scanner sounds an error tone and Error appears. Press Func + to change the search direction downward or Func + to change the search direction upward. Frequencies appear during the search. Notes: • You can set the delay function on or off during the search or while the search stops. • You can skip a frequency when the search stops. After the search skip frequency is set, the scanner starts direct search again. Direct Entry Search Hold Mode To stop searching during direct entry search, press Hold. Hold appears. In this mode, pressing Func + changes the search direction downward and pressing Func + changes the search direction upward. or appears depending on the search direction. Press Func + to decrease the frequency by one step or Func + to increase it by one step. Hold down or for about 1 second to quickly increase or decrease the frequency. To resume direct search, press Func + Src or Hold. or appears on the display, showing the search direction. Special Features 44 BC72 Paper OM.fm Page 45 Monday, October 25, 2004 3:11 PM Storing Frequencies Found During Direct Entry Search into Channel Memory Follow these steps to store frequencies received during direct entry search mode or direct entry search hold mode. 1. Press Func + Pgm in direct entry search mode or direct entry search hold mode. The frequency and lowest blank channel alternate on the display. 2. Press E to store the frequency into the blank channel. To select another channel, repeatedly press Func + or Func + to select the blank channel you want, then press E. You can also use the 0-9 keys to select the bank. If you enter a frequency that has already been entered elsewhere, the scanner sounds an error tone and displays the channel that was duplicated. If you entered the frequency by mistake, press . To enter the frequency anyway, press E to accept. The scanner moves to program mode after you stored the frequency. Search Skip Memory You can skip up to 50 specified frequencies during a search. This lets you avoid unwanted frequencies or those already stored in a channel. Notes: • You cannot skip frequencies during WX service search. • Search skip frequencies are shared by service search, direct entry search, chain search, and Close Call modes. If skip frequencies are sent in certain mode, the frequencies are also skipped in other search modes and Close Call mode. Special Features 45 BC72 Paper OM.fm Page 46 Monday, October 25, 2004 3:11 PM To skip a frequency, press Func and L/O when the scanner stops on the frequency during a search or a search hold. The scanner stores the frequency in memory and automatically resumes the search if it is not in hold. Follow these steps to clear a single frequency from skip memory so the scanner stops on it during a search. 1. Press Hold to stop the search. 2. Press Func + or Func + frequency. L/O appears. to select the 3. Press Func + L/O. L/O disappears. To clear all the skip frequencies at once while searching or search hold, press Func then press and hold L/O until the scanner beeps. Notes: • If you selected all frequencies to be skipped within the search range, the scanner beeps 3 times and does not search. • If you select more than 50 frequencies to skip, each new frequency replaces a frequency previously stored, beginning with the first stored frequency. • Press Func + or Func + to select a skipped frequency while Hold appears. L/O appears when you select a skipped frequency. Delay Sometimes a user might pause before replying to a transmission. To avoid missing a reply on a specific channel, you can program a 2-second delay into any channel or frequency. The scanner continues to monitor the channel frequency for an additional Special Features 46 BC72 Paper OM.fm Page 47 Monday, October 25, 2004 3:11 PM 2 seconds after the transmission stops before resuming scanning or searching. The scanner automatically sets a delay when you store frequencies into channels or when you search frequencies. When the delay feature is on, DLY appears. If it is off, follow one of these steps to program a delay depending on how the scanner is operating,. • If the scanner is scanning and stops on an active channel where you want to store a delay, quickly press Func + Dly before it continues scanning again. DLY appears. • If the desired channel is not selected, manually select the channel, then press Func + Dly. DLY appears. • If the scanner is searching, press Func + Dly while the scanner is searching. DLY appears and the scanner automatically adds a 2-second delay to every frequency it stops on in that band. To turn off the 2-second delay, press Func + Dly while the scanner is monitoring a channel, scanning, or searching. DLY disappears. Turning Channel-Storage Banks On and Off You can turn each channel-storage bank on and off. When you turn off a bank, the scanner does not scan any of the 10 channels in that bank. While scanning, press the number key that corresponds to the bank you want to turn on or off. Numbers appear at the top of the display, showing the currently selected banks. The scanner scans all the channels within the displayed banks that are not locked out (see “Lock- Special Features 47 BC72 Paper OM.fm Page 48 Monday, October 25, 2004 3:11 PM ing Out Channels” on Page 48). The bank number flashes when the scanner scans a channel that belongs to the bank. Notes: • You can manually select any channel within a bank, even if that bank is turned off. • You cannot turn off all banks. One bank must always be active. Locking Out Channels You can increase the scanning speed by locking out channels that have a continuous transmission, such as a weather channel. To lock out a channel, manually select the channel, then press Func + L/O. L/O appears. Note: You can still manually select locked-out channels. To remove the lockout from a channel, manually select the channel, then press Func + L/O. L/O disappears. To unlock all channels in the banks that are turned on, press Hold to stop scanning, then press Func and press and hold L/O until the scanner beeps twice. Priority The priority feature lets you scan through the channels and still not miss important or interesting calls on specific channels. You can program one stored channel in each bank as a priority channel (10 for the banks). Special Features 48 BC72 Paper OM.fm Page 49 Monday, October 25, 2004 3:11 PM If the priority feature is turned on, as the scanner scans the bank, it checks that bank's priority channel for activity every 2 seconds. The scanner automatically designates each bank's first channel as its priority channel. Follow these steps to select a different channel in a bank as the priority channel. 1. Manually select the channel you want to select as the priority channel. 2. Press Func + Pgm, then press Func + Pri. P appears to the left of the selected channel number. 3. Repeat Steps 1 and 2 for the channel in each bank you want to program as a priority channel. To turn on the priority feature, press Func + Pri during scanning. PRI appears. Then the scanner checks the designated priority channel every 2 seconds in each bank. To turn off the priority feature, press Func + Pri. PRI disappears. Using Keylock Use the scanner's keylock to protect it from accidental program changes. When the scanner's keys are locked, the only controls that operate are Scan, Func, Hold, , , and . To turn on keylock, press Func + . appears. To turn off keylock, press Func + disappears. . Note: Using keylock does not prevent the scanner from scanning channels. Special Features 49 BC72 Paper OM.fm Page 50 Monday, October 25, 2004 3:11 PM Using the Display Backlight To turn on the display light for easy viewing at night, press . The display lights for 15 seconds. To turn off the light sooner, press again. Special Features 50 BC72 Paper OM.fm Page 51 Monday, October 25, 2004 3:11 PM Troubleshooting If your BC72XLT is not performing properly, try the Troubleshooting following steps. Problem Possible Cause The scanner doesn’t work. The scanner might not be receiving any power. Improper reception. The scanner’s antenna might need to be adjusted. Scan won’t stop. The squelch might need to be adjusted. Suggestion Check the batteries or make sure the AC adapter is connected to an AC outlet and the scanner. If there is a wall switch that controls power to the AC outlet where you connected the AC adapter, make sure it is on. Check the antenna connection or move or reposition the antenna. Move the scanner. You might be in a remote area that could require an optional multi-band antenna. Check with your dealer or local electronics store. Adjust the squelch threshold. See “Turning On The Scanner and Setting Squelch” on Page 33. Troubleshooting 51 BC72 Paper OM.fm Page 52 Monday, October 25, 2004 3:11 PM Scan won’t stop (continued) Scan won’t start. The antenna might need to be adjusted. One or more channels might be locked out. The channel’s frequency might not be stored in memory. The channel might not be active. You must press Scan to scan. The squelch might need to be adjusted. One or more channels might be locked out. The antenna might need to be adjusted. Check the antenna connection. Make sure the channels you want to scan are not locked out. Make sure the channel’s frequency is stored in the scanner’s memory. Wait for a transmission on the channel. Press Scan. Adjust the squelch threshold. See “Turning On The Scanner and Setting Squelch” on Page 33. Make sure the channels you want to scan are not locked out. Check the antenna connection. Troubleshooting 52 BC72 Paper OM.fm Page 53 Monday, October 25, 2004 3:11 PM Weather scan doesn’t work. The squelch might need to be adjusted. The antenna might need to be adjusted. Adjust the squelch threshold. See “Turning On The Scanner and Setting Squelch” on Page 33. Check the antenna connection. Resetting the Scanner If the scanner's display locks up or stops operating properly, you might need to reset the scanner. Caution: This procedure clears all the information you have stored in the scanner. Before you reset the scanner, try turning it off and on to see if it begins working properly. Reset the scanner only when you are sure it is not working properly. 1. Turn off the scanner. 2. While holding down 2, 9, and Hold, turn on the scanner. It takes about 3 seconds to initialize and CLEAr appears. Troubleshooting 53 BC72 Paper OM.fm Page 54 Monday, October 25, 2004 3:11 PM Care and Maintenance Keep the scanner dry. If it gets wet, wipe it dry Care and Maintenance immediately. Use and store the scanner only in normal temperature environments. Handle the scanner carefully: do not drop it. Keep the scanner away from dust and dirt, and wipe it with a damp cloth occasionally to keep it looking new. General Use • Turn the scanner off before disconnecting the power. • Always write down the programmed frequencies in the event of memory loss. • If memory is lost, simply reprogram each channel. The display shows 000.0000 in all channels when there has been a memory loss. • Always press each button firmly until you hear the entry tone for that key entry. Location • Do not use the scanner in high-moisture environments such as the kitchen or bathroom. • Avoid placing the unit in direct sunlight or near heating elements or vents. • If the scanner receives strong interference or electrical noise, move it or its antenna away from the source of the noise. If possible, a higher elevation might provide better reception. • Also try changing the height or angle of the antenna. Cleaning • Disconnect the power to the unit before cleaning. Care and Maintenance 54 BC72 Paper OM.fm Page 55 Monday, October 25, 2004 3:11 PM • Clean the outside of the scanner with a mild detergent. • To prevent scratches, do not use abrasive cleaners or solvents. Be careful not to rub the LCD window. • Do not use excessive amounts of water. Repairs Do not attempt any repair. The scanner contains no user serviceable parts. Contact the Uniden Customer Service Center or take it to a qualified repair technician. Birdies All radios can receive “birdies” (undesired signals). If your scanner stops during Scan mode and no sound is heard, it might be receiving a birdie. Birdies are internally generated signals inherent in the electronics of the receiver. Press L/O to lock out the channel, then press Scan to resume scanning. If you still cannot get satisfactory results while using your scanner or if you want additional information, please call or write the Uniden Parts and Service Division. The address and phone number are listed in the Warranty at the end of this manual. If you would like immediate assistance, please call Customer Service at (800) 297-1023. If you have Internet access, you can visit http://www.uniden.com for additional information. Care and Maintenance 55 BC72 Paper OM.fm Page 56 Monday, October 25, 2004 3:11 PM Specifications Specifications Specifications Certified in accordance with FCC Rules and Regulations Part 15, Subpart C, as of date of manufacture. Channels: ........................................................... 100 Banks: .................................. 10 (10 channels each) Frequency Range (in MHz): 25.0-27.995 .............. Citizens Band/Business Band 28.0–29.995 ...................... 10 Meter Amateur Band 30.0–49.995 .................................... VHF Low Band 50.0–54.0 ...........................6 Meter Amateur Band 137.0–143.995 MHz ..............Military Land Mobile 144.0–147.995 .................... 2 Meter Amateur Band 148.0–174.0 ...................................VHF High Band Above bands in 5 kHz steps 108.0–136.9875 ..................................Aircraft Band Above bands in 12.5 kHz steps 406.0–419.99375 ..................Federal Land Mobile 420.0–449.99375 .................. 70 cm Amateur Band 450.0–469.99375 ................... UHF Standard Band 470.0–512.0 ......................................UHF TV Band Above bands in 6.25 kHz steps Specifications 56 BC72 Paper OM.fm Page 57 Monday, October 25, 2004 3:11 PM Sensitivity (SINAD 12 dB) 25.005 MHz (AM) ........................................ 0.5 µV 40.840 MHz (FM) ........................................ 0.3 µV 49.900 MHz (FM) ........................................ 0.3 µV 118.800 MHz (AM)........................................ 0.5 µV 127.175 MHz (AM)........................................ 0.5 µV 135.500 MHz (AM) ....................................... 0.5 µV 138.150 MHz (FM)........................................ 0.3 µV 162.400 MHz (FM) ....................................... 0.3 µV 173.225 MHz (FM) ....................................... 0.3 µV 406.875 MHz (FM)........................................ 0.4 µV 453.250 MHz (FM) ....................................... 0.4 µV 511.9125 MHz (FM) ..................................... 0.4 µV Operating Temperature: Normal ........................................... –20°C to +60°C Close Call ...................................... –10°C to +50°C Scan Rate: ............... 50 channels per second (max) Search Rate Normal .......................... 60 steps per second (max) Hyper .......................... 180 steps per second (max) Priority Sampling ..................................... 2 seconds Scan Delay: ............................................ 2 seconds IF Rejection (at 162.4 MHz) ........................... 90 dB Specifications 57 BC72 Paper OM.fm Page 58 Monday, October 25, 2004 3:11 PM IF Frequencies 1st IF (25-174 MHz)..........380.6050-380.7000 MHz 1st IF (406-512 MHz) .......380.6125-380.7000 MHz 2nd IF ...................................................... 21.3 MHz 3rd IF ........................................................ 450 kHz Audio Output .............................. 490 mW maximum Built-in Speaker ........................... 32 mm dia, 8 ohm Dynamic Type Current Drain Squelched ..................................................110 mA Full Output ................................................. 310 mA Power Requirements: 2 AA Alkaline Batteries (3V DC), or 2 AA Rechargeable Ni-MH Batteries (2.4V DC), or AC Adapter (6 VDC 500mA) Antenna: ................................50 ohms (Impedance) External Jacks: ................ Antenna Jack BNC Type Ext. Speaker Jack 3.5mm DC Power Jack ...........................................4.4 mm Size: .................23/4 in. (W) x 11/4 in. (D) x 41/2 in. (H) Weight: ...........................................................5.8 oz Features, specifications, and availability of optional accessories are all subject to change without notice. Specifications 58 BC72 Paper OM.fm Page 59 Monday, October 25, 2004 3:11 PM Optional Accessories Optional Accessories Contact your local Uniden Dealer or call the Uniden Parts Center at: (800)554-3988, 8:00AM to 5:00PM EST, Monday through Friday, for information about ordering these optional accessories. Earphone fi Remote Speaker Betty Bearcat Frequency Directory/ Local Directories Optional Accessories 59 BC72 Paper OM.fm Page 60 Monday, October 25, 2004 3:11 PM One-Year Limited Warranty ranty One-Year Limited WarImportant: Evidence of original purchase is required for warranty service. WARRANTOR: UNIDEN AMERICA CORPORATION (“Uniden”) ELEMENTS OF WARRANTY: Uniden warrants, for one year, to the original retail owner, this Uniden Product to be free from defects in materials and craftsmanship with only the limitations or exclusions set out below. WARRANTY DURATION: This warranty to the original user shall terminate and be of no further effect 12 months after the date of original retail sale. The warranty is invalid if the Product is (A) damaged or not maintained as reasonable or necessary, (B) modified, altered, or used as part of any conversion kits, subassemblies, or any configurations not sold by Uniden, (C) improperly installed, (D) serviced or repaired by someone other than an authorized Uniden service center for a defect or malfunction covered by this warranty, (E) used in any conjunction with equipment or parts or as part of any system not manufactured by Uniden, or (F) installed or programmed by anyone other than as detailed by the Operating Guide for this product. STATEMENT OF REMEDY: In the event that the product does not conform to this warranty at any time while this warranty is in effect, warrantor will repair the defect and return it to you without charge for parts, service, or any other cost (except shipping and handling) incurred by warrantor or its representatives in connection with the performance of this warranty. THE LIMITED WARRANTY SET FORTH ABOVE IS THE SOLE AND ENTIRE WARRANTY PERTAINING TO THE PRODUCT One-Year Limited Warranty 60 BC72 Paper OM.fm Page 61 Monday, October 25, 2004 3:11 PM AND IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES OF ANY NATURE WHATSOEVER, WHETHER EXPRESS, IMPLIED OR ARISING BY OPERATION OF LAW, INCLUDING, BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THIS WARRANTY DOES NOT COVER OR PROVIDE FOR THE REIMBURSEMENT OR PAYMENT OF INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow this exclusion or limitation of incidental or consequential damages so the above limitation or exclusion might not apply to you. LEGAL REMEDIES: This warranty gives you specific legal rights, and you might also have other rights which vary from state to state. This warranty is void outside the United States of America. PROCEDURE FOR OBTAINING PERFORMANCE OF WARRANTY: If, after following the instructions in this Operating Guide you are certain that the Product is defective, pack the Product carefully (preferably in its original packaging). Include evidence of original purchase and a note describing the defect that has caused you to return it. The Product should be shipped freight prepaid, by traceable means, or delivered, to warrantor at: Uniden America Corporation Parts and Service Division 4700 Amon Carter Boulevard Fort Worth, TX 76155 (800) 297-1023, 7:00 a.m. to 7:00 p.m., Central, Monday through Friday One-Year Limited Warranty 61 BC72 Paper OM.fm Page 62 Monday, October 25, 2004 3:11 PM 62 BC72 Paper OM.fm Page 63 Monday, October 25, 2004 3:11 PM 63 BC72 Paper OM.fm Page 64 Monday, October 25, 2004 3:11 PM , S E R RI & OM O F SO NE .C S LI N E E C ON ID C A O .UN G W W W REGISTER ONLINE TODAY! THANK YOU FOR BUYING A UNIDEN PRODUCT. THANK YOU FOR BUYING A UNIDEN PRODUCT. May be covered under one or more of the following U.S. patents. 4,398,304 4,627,100 5,199,109 5,471,660 5,577,076 5,896,422 6,064,270 4,409,688 4,841,302 5,408,692 5,483,684 5,598,430 5,991,346 6,266,521 4,455,679 4,888,815 5,428,826 5,530,296 5,600,223 5,991,603 4,461,036 4,932,074 5,438,688 5,548,832 5,642,424 6,012,158 4,521,915 4,947,456 5,448,256 5,571,071 5,710,992 6,025,758 4,597,104 5,014,348 5,465,402 5,574,995 5,859,875 6,034,573 ©2004. Uniden America Corporation, Fort Worth, Texas Contains additional foreign articles. Custom manufactured in China. UBZZ01323ZZ
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2004:10:25 15:12:01-05:00 Modify Date : 2004:10:25 15:12:01-05:00 Page Count : 64 Creation Date : 2004:10:25 20:12:01Z Mod Date : 2004:10:25 20:12:01Z Producer : Acrobat Distiller 5.0.5 (Windows) Author : RPrice Metadata Date : 2004:10:25 20:12:01Z Creator : RPrice Title : BC72 Paper OM.fmEXIF Metadata provided by EXIF.tools