Uniform EPORTG6 Contactless Card Reader User Manual ePort G6 Programming Manual

Uniform Industrial Corp. Contactless Card Reader ePort G6 Programming Manual

Users Manual

    ePort G6 Contactless Smart Card Reader Module    Programmer’s Manual         Document #: PM059-U Revision A Jan 18, 2006
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  INOTICE The issuer of this manual has made every effort to provide accurate information contained in this manual. The issuer shall not be held liable for any technical and editorial omissions or errors made herein; nor for incidental consequential damages resulting from the furnishing, performance or use of this material. This document contains proprietary information protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated without the prior written permission of the issuer. The information provided in this manual is subject to change without notice.  AGENCY APPROVED - Specification for FCC Class B  NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/ TV technician for help.  You are cautioned that any change or modifications to the equipment not expressly approve by the party responsible for compliance could void your authority to operate such equipment.    WARNING You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  II WARRANTY This product is served under one-year warranty of defects in material and functionality to the original purchasers. Within the warranty period, if the product found to be defective will be repaired or replaced. This warranty applies to the products only under the normal use of the original purchasers, and in no circumstances covers incidental or consequential damages through consumers’ misuse or modification of the product.  PREFACE This manual provides detailed information relating to the overall operational, electrical, mechanical, environmental and functional aspects of the ePort G6. This document should be read and understood prior to initial operation of the product.   For ease of installation and programming use, we have addressed everything from its attractive features to its various configurations. When designing the ePort G6, we selected what we feel are the most useful features and functions. If in some cases you find that your specific needs differ from our existing products, we welcome your comments and suggestions. Custom-designed models are also available.  If further questions do arise, please call for technical support, our FAE will assist you in any way we can.
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  IIITable of Contents Section1 : General Description................................................................. 1-1 Features................................................................................................................... 1-1 Application.............................................................................................................. 1-1 Section2 : Configurations ......................................................................... 2-2 Dimensions of ePort G6 PCBA.............................................................................. 2-2 Dimensions of Antenna PCBA............................................................................... 2-2 Accessories of ePort G6 ........................................................................................ 2-3 Section3 : Technical Specifications ......................................................... 3-4 Functional Specifications ...................................................................................... 3-4 Electrical Specifications ........................................................................................ 3-4   Power Required ........................................................................................................... 3-4   Power Consumption..................................................................................................... 3-4   Communication............................................................................................................ 3-4   Communication Signal (RS232) .................................................................................. 3-4 Environmental Specifications................................................................................ 3-5   Temperature................................................................................................................. 3-5   Humidity ....................................................................................................................... 3-5 Pin Assignment....................................................................................................... 3-6 Communication....................................................................................................... 3-7   RS232 Interface Data Output ...................................................................................... 3-7   RS232 Interface Pass Through ................................................................................... 3-7   F2F TTL Interface (Optional) ....................................................................................... 3-7   Transmission Protocol (RS232)................................................................................... 3-7 Section4 : Commands and Responses.................................................. 4-10 4.1 Reader default setting.....................................................................................4-10 4.2 Reader Command Description .......................................................................4-10   % (25H) – Retransmit ................................................................................................ 4-10   70 (3730H) or 90 (3930H) – Serial Number Report................................................... 4-10   71 (3731H) or 91 (3931H) – Copyright Report .......................................................... 4-10   72 (3732H) or 92 (3932H) – Reader Model Number Report ..................................... 4-11   73 (3733H) or 93 (3933H) – Reader PCB Number Report........................................ 4-11   74 (3734H) or 94 (3934H) – Contactless Smart Card Library Version Report .......... 4-11   75 (3735H) or 95 (3935H) – F/D Parameters List Report.......................................... 4-11   76 (3736H) or 96 (3936H) – Boot loader Version Number Report ............................ 4-11
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  IV  77 (3737H) or 97 (3937H) – Reader Configuration Data Report............................... 4-11   78 (3738H) or 98 (3938H) – Reader Customer Configuration Data Report.............. 4-12   79 (3739H) or 99 (3939H) – Reader Manufacturing Configuration Data Report....... 4-12   9 (39H) – Version Report ........................................................................................... 4-13   ? (3FH) – Select Verbose Responses Command...................................................... 4-13   $ (24H) – Reader Status Request.............................................................................. 4-13   L (4CH) – LED ON .....................................................................................................4-14   l (6CH) – LED OFF .................................................................................................... 4-14   ( (28H) – LED flash .................................................................................................... 4-14   # (23H) – Configuration Request............................................................................... 4-14   <CAN> (18H) – Pass through toggle......................................................................... 4-15   <7FH> – Warm Reset ................................................................................................ 4-15   <09H> – Configuration Setting .................................................................................. 4-15 4.3 Contactless Mag Stripe Command Description ............................................4-17   P (50H) – Arm to Read............................................................................................... 4-17   p (70H) – Arm to Read (Used for Manufacturing Test Only )..................................... 4-17   <ESC> (1BH) – Abort Arm to Read ........................................................................... 4-17   Q (51H) – Transmit Track 1 data ............................................................................... 4-17   R (52H) – Transmit Track 2 data................................................................................ 4-17 4.4 Contactless Smart Card Command Descriptions.........................................4-18   G (47H) – ISO14443 type protocol select.................................................................. 4-18   H(48H) – PayPass/Express card auto read function disable/enable......................... 4-18   O (4FH) – Antenna power on..................................................................................... 4-18   o (6FH) – Antenna power OFF .................................................................................. 4-19   b (62H) – Request...................................................................................................... 4-19   c (63H) – Anticollision(type A)/Slot-Marker ................................................................ 4-19   f (65H) – Select(type A)/Attrib(type B) ....................................................................... 4-20   g (66H) – Mifare classical card authentication........................................................... 4-21   h (67H) – Mifare classical card read block................................................................. 4-21   i (68H) – Mifare classical card write block ................................................................. 4-22   t (74H) – Mifare Value Operation ............................................................................... 4-22   X (58H) – Mifare classical card activation.................................................................. 4-23   x (78H) – Card halt..................................................................................................... 4-23   J (6BH) – Activate PICC cpu card.............................................................................. 4-23   j (6BH) – Load Mifare key (Mifare classical card only) .............................................. 4-23   k(6CH) – Mifare Reader Chip Direct Control ............................................................. 4-24   y (79H) – Send DESELECT command...................................................................... 4-24   Z (41H) – I/O to contactless CPU card with APDU format......................................... 4-24   z (7AH) – I/O to contactless card for block data exchange ....................................... 4-25 3.6 Responses to the Host....................................................................................4-26
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  1-1Section1: General Description This section presents general information about the basic characters of the ePort G6. Features The ePort G6 provides the following features: 1  Small footprint PCB size: 1.4L*1.7W (inch) without antenna board 2  Support ISO 14443 type A & B standard 3  Support Amex ExpressPay, MasterCard PayPass, Visa MSD applications.   4  Read/write Philips Mifare classical contactless smart card 5  Provide the options for the direct coupling antenna and the remote antenna 6  RS232, and serial TTL (optional) Interface 7  RS232 data pass through function 8  TTL F2F magnetic stripe decode data pass through (optional) 9  F2F decoder data emulation (optional) 10 Firmware upgradeable  Application The contactless smart card reader module ePort G6 is mainly to support the contactless payment systems. The small footprint size of the module makes it easily to integrate to the current transaction system such as Point-of-Sale terminal, kiosk, and vending machine station as the part of the system.  The module communicates with a host computer or terminal using a standard RS-232 or TTL interface.    At the meantime, ePort G6 offers both RS232 and TTL magnetic stripe decoder pass-thru function to allow the terminal to share the same input port with other peripheral devices. The TTL interface output is in the F2F decoder data emulation. This benefits the existing system without change its hardware configuration to catch up the future payment trend.
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  2-2 Section2: Configurations This section shows the dimensions, accessories and setup for the ePort G6. Dimensions of ePort G6 PCBA Figure 2-1 Dimensions of ePort G6 PCBA         Dimensions of Antenna PCBA Figure 2-2 Dimensions of Antenna PCBA
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  2-3 Accessories of ePort G6 The following accessories should be supplied along with ePort G6. Make sure all the following accessories are contained in your package.  1. Interface cable - DB9 male connector 1.5M   2. Programmer’s manual or Simple manual 3. Power adapter 12Vdc 500mA (RS232 interface only)
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  3-4 Section3: Technical Specifications Functional Specifications  •  Contactless communication at 13.56MHz •  Proximity operation distance of up to 100mm •  4 output lines for external LED indication (support Paypass application) • Audio buzzer •  Support RS232 data output baud rate up to 115.2K BPS •  Support RS232 pass through baud rate up to 38400 BPS •  Support TTL level for serial data output (optional) •  Support TTL level for F2F decoder data output emulation (optional) •  Support direct matching antenna •  Support Remote 50 ohm matching antenna (optional) •  Support all layers of 14443 including the type A and B communication scheme •  Support contactless communication using MIFARE higher baud rate up to 424KHz •  Support the fast MIFARE Classic security algorithm to authenticate MIFARE classic products •  Support American Express ExpressPay transaction application •  Support MasterCard PayPass transaction application •  Support Visa MSD transaction application Electrical Specifications • Power Required 12VDC  • Power Consumption 100mA in idle mode; 200mA in operating mode  • Communication Standard RS232 signal level   TTL 5V signal level (optional)  • Communication Signal (RS232) Logic 1 = -3 volts to –15 volts or TTL level 5 volts
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  3-5Logic 0 = +3 volts to +15 volts or TTL level 0 volt Environmental Specifications • Temperature Operating: -10-50℃ Storage:   -30-70℃  • Humidity Operating: 10-85% (non condensing) Storage:     10-90% (non condensing)
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  3-6Pin Assignment Table 3-1. Interface J3 Pin Assignment (RS232 level) DB9  Signal  Direction  PCB-J1 Signal 5 GND   1 GND 2 RxD Å Serial data to host 2  TXD1 3 TxD Æ Serial data from host3  RXD1     4 VCC   (Pass-thru function) 5 TXD2   (Pass-thru function) 6 RxD2  Shield   7 Shield  Table 3-2. Extension Port J1 Pin Assignment (TTL Level) Pin  Signal  Comment 1 GND   2 VCC  5Vdc 3 Extended IO   4 Extended IO   5 Extended IO   6 Extended IO   7 Buzzer + output  8 Extended IO   9 Extended IO   10 Extended IO   11 Extended IO   12 Extended IO   13 Extended IO   14  Extended IO   15  Extended IO   16  Extended IO   17  Extended IO   18  Extended IO   19  Extended IO   20  Extended IO    Table 3-3. 50 RF Antenna Port J2B Pin Assignment
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  3-7Contact number  Signal 1 RF output 2 GND  Table 3-4. Direct Match Antenna Port J2A Pin Assignment Contact number  Signal 1 RX 2 TX 3 GND 4 GND     Communication • RS232 Interface Data Output Synchronization The interface receives and transmits serial asynchronous data at voltage levels compatible with the RS232 specification.  Baud Rate 9600 BPS default (optional: 1200/2400/4800/9600/19200/38400/56000/115.2K BPS)  • RS232 Interface Pass Through  Baud Rate 9600 BPS default (optional: 1200/2400/4800/9600/19200/38400 BPS)  • F2F TTL Interface (Optional) Each track has the clock and data. Please refer to command set for the detail setting.  • Transmission Protocol (RS232) The user may select from three different protocols: Protocol 0, 1, and 2. Upon reset, the reader sends the power-on response “:”, depending upon the configuration setting. The reader then configures itself to the protocol of the first command from the host. From this point on, the protocol is unchangeable until a reset occurs.
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  3-8Protocol 0 In Protocol 0, all characters are transmitted and received using exactly the characters listed in section 4. There are no headers and Block Check Characters (BCC). Protocol 0 presumes no transmission errors. If the host detects an error, it may request a retransmission.  Table 3-3. Example for Protocol 0     Protocol 1 In Protocol 1, all messages are preceded by the ASCII character <STX> and terminated with the ASCII character <ETX>, followed by a one byte <BCC>. <BCC> is an XOR of the 7 data bits, excluding parity, of each character in the entire message, including <STX>.  Format: <STX><MESSAGE><ETX><BCC> where STX=02Hex and ETX=03Hex.  Table 3-4. Example for Protocol 1     Protocol 2 In Protocol 2, all messages are preceded by the ASCII character <SOH>, followed by a one byte reader address, one byte character count and terminated with a one byte <BCC>. The <BCC> is an XOR of the characters (8 bits) in the entire message, including <SOH>. Format: <SOH><ADDRESS><00Hex><COUNT><MESSAGE><BCC>                                  or <SOH><ADDRESS><00Hex><00Hex><MESSAGE><EOT><BCC> where STX=02Hex and ETX=03Hex.  Table 3-5. Example for Protocol 2 Host Command  Reader Response  Comment 01h 00h 00h 01h 50h 50h    Ready to read   01h 00h 00h 01h 5Eh 5Eh Reader ACK  The <ADDRESS> field is for a multi-reader system. This function is not currently supported. The recommended value for this field is NULL (00Hex), however, any value will work. Host Command  Reader Response Comment P    Ready to read ^ Reader ACK Host Command  Reader Response Comment 02h 50h 03h 51h    Ready to read  02h 5Eh 03h 5Fh Reader ACK
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  3-9If the value of <COUNT> fields are zero, an <EOT>, followed by the <BCC>, completes the message. The reader may, at its option, use NULL for COUNT when transmitting.  For Protocols 1 and 2, if the reader detects an error in an incoming transmission, it will respond with a “Communications Error” message. If the host detects a transmission error, it may request a retransmission. Both protocols enforce a 100mSec timeout between characters. For all Protocols, the host may, at any time, stop/start the reader transmission by using software “handshake” (DC3/DC1).
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  4-10Section4: Commands and Responses 4.1 Reader default setting  Output type: RS232   Data format: 9600-8-N-1 Pass through function: Disable Pass through data format: 9600-8-N-1 Buzzer function: Enable Protocol format: USI0 PnP function: Disable Contactless smart card manual type: type A Contactless self-arm mode: Disable Contactless payment card reading: PayPass, ExpressPay, Visa MSD  Note 1: when “Contactless self-arm mode” turns on, ePort G6 will automatic read the card in the reading zone for both type A and B cards.   Note 2: the manual contactless card operation commands are invalid when “Contactless self-arm mode” is on. To switch manual operation mode, user needs to disable the “Contactless self-arm mode” first.   4.2 Reader Command Description  • % (25H) – Retransmit   COMMENT    Retransmits the last message sent by the reader.   NOTE      Command is turned off in self-arm mode.    • 70 (3730H) or 90 (3930H) – Serial Number Report COMMENT    Transmit version and copyright information.   The Serial number will be stored in the EEPROM and stored as an eight-digit ASCII character array. Example:  “00000000”   • 71 (3731H) or 91 (3931H) – Copyright Report   COMMENT    Transmit version and copyright information.
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  4-11Send this when you want to know the version and copyright of the Model ePort G6 firmware currently loaded. The response is an ASCII string giving the firmware date (yymmdd), reader type and the firmware version number followed by the firmware copyright statement. The firmware copyright statement is absent in OEM version. Example: “031226,ePort0001A:V1.A”  • 72 (3732H) or 92 (3932H) – Reader Model Number Report COMMENT    Transmit reader configuration information.   The model number will be stored in the reader code area and stored as a three to eight-digit ASCII string.   Example:  “ePort G6”  • 73 (3733H) or 93 (3933H) – Reader PCB Number Report COMMENT    Transmit reader PCB number. The PCB number will be stored in the EEPROM and stored as an eight-digit ASCII character array. Example: “680-REV1”  • 74 (3734H) or 94 (3934H) – Contactless Smart Card Library Version Report COMMENT    Transmit smart card library version.   The smart card library version may help determine if the current library has a particular feature for contactless smart card. It will present as 3 bytes hex number. Example:  00 01 01   • 75 (3735H) or 95 (3935H) – F/D Parameters List Report COMMENT    Transmit the parameters list of supported F/D This command returns all the values of TA1 parameter (baud rate values) that are supported by UIC360. About the values means please refer the ISO 14443-3 type A specification. Example:     01 02 03 04 08 11 12 13 14 18 21 22 23 28 31 32     33 34 35 38 41 42 43 44 48 51 52 53 54 55 56 58     61 62 63 64 68 69 91 92 93 94 95 96 A1 A2 A3 A4     A5 A8 B1 B2 B3 B4 B5 B6 C1 C2 C3 C4 C5 C6 C8 D1     D2 D3 D4 D5 D6  • 76 (3736H) or 96 (3936H) – Boot loader Version Number Report COMMENT    Transmit bootloader version number.   Example: “1.0”   • 77 (3737H) or 97 (3937H) – Reader Configuration Data Report
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  4-12COMMENT    Transmit the reader configuration data.   The data from the reader configuration area will be transmitted to the host as hex values with the command “77” [offset] [num]. The reader will return any or all the bytes from the reader configuration. The offset is an optional byte and the available value is from 0x00 to 0x3F. The num is an optional byte specifying the number of configuration bytes to be returned. If the offset and length bytes are omitted then the current configuration starting at offset 0 is transmitted.   Example:      BE 0C 05 00 00 00 00 61 30 33 31 31 32 38 00 7D     28 54 4B 31 3A 3A 45 6E 64 29 28 54 4B 32 3A 3A     45 6E 64 29 28 54 4B 33 3A 3A 45 6E 64 29 00 00     00 00 00 00 00 00 00 00 3A 48 43 52 33 36 30 00  • 78 (3738H) or 98 (3938H) – Reader Customer Configuration Data Report   COMMENT  Transmit the reader customer configuration data.   The data from the reader customer configuration area of the EEPROM will be transmitted to the host as hex values with the command “78¨ [offset] [num]. The reader will return any or all the bytes from the reader configuration. The offset is an optional byte and the available value is from 0x00 to 0x3F. The num is an optional byte specifying the number of configuration bytes to be returned. If the offset and length bytes are omitted then the current configuration starting at offset 0 is transmitted.   Example:      31 30 30 30 30 30 30 30 33 36 30 2D 52 45 56 33     FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF     FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF     FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF  • 79 (3739H) or 99 (3939H) – Reader Manufacturing Configuration Data Report   COMMENT    Transmit the reader manufacturing configuration data.   The data from the reader manufacturing configuration area of the flash will be transmitted to the host as hex values with the command “79” [offset] [num]. The reader will return any or all the bytes from the reader configuration. The offset is an optional byte and the available value is from 0x00 to 0x7F. The num is an optional byte specifying the number of configuration bytes to be returned to the host. If the offset and length bytes are omitted then the current configuration starting at offset 0 is transmitted.   Example:      BE 0C 05 00 00 00 00 61 30 33 31 31 32 38 00 79     00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00     00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00     00 00 00 00 00 00 00 00 3A 48 43 52 33 36 30 00
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  4-13Note: Commands 70 to 79 were same as 90 to 99 and supported for previous version reader compatible.   • 9 (39H) – Version Report   COMMENT    Transmit version information.   Send this when you want to know the version of UIC360 firmware currently loaded. The response is an ASCII string giving the firmware date (yymmdd), reader type and firmware version number.   Example: “031226, ePort G6:V1.A¨.    • ? (3FH) – Select Verbose Responses Command COMMENT    Most error responses until the reader receives a reset command will include a short descriptive message.   EXAMPLE    After sending a “?” to the reader then attempt to close the latch by sending the “{“ command. Examples of responses that may be returned: If success returns a ‘^’ as well.   If a card is partially inserted returns “!may only latch when card seated”.    • $ (24H) – Reader Status Request   COMMENT    Interrogate the reader about its operational status. Two bytes of status information will be returned.   First Status Byte Bit  Value: 0  Value: 1 0:0  Reserve for future use  Reserve for future use 0:1  Reserve for future use  Reserve for future use 0:2  Reserve for future use  Reserve for future use 0:3  Reserve for future use  Reserve for future use 0:4  Reserve for future use  Reserve for future use 0:5  No Magnetic Stripe Card data Magnetic Stripe Card data 0:6  Not armed to read  Armed to read 0:7  Reserve for future use  Reserve for future use  Second Status Byte Bit  Value: 00  Value: 01  Value: 10  Value: 11 1:0 - 1:1  Reserved for future use, always 0.    1:2 - 1:3  Reserved for future use, always 0.
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  4-141:4 – 1:7  Reserved for future use, always zero  • L (4CH) – LED ON   • l (6CH) – LED OFF   • ( (28H) – LED flash   COMMENT    1.Turn first/second LED ON/OFF/Flash, as specified.   2.Transmits an acknowledgement "^" (5EH).   NOTE    These commands are disabled in the self-arm mode.     • # (23H) – Configuration Request   COMMENT    Return standard one byte or extended 16-byte string with configuration.   NOTE    Using the configuration setting command to select standard or extended format.    Standard One Configuration Byte Bit  Value: 0  Value: 1 0  Track 1 not present  Track 1 present 1  Track 2 not present  Track 2 present 2  Track 3 not present  Track 3 present 3  Reserved for future use, always 0.  4  Reserved for future use, always 0.  5  Reserved for future use, always 0.  6  Reserved for future use, always 0.  7  Reserved for future use, always 0.   Extended Configuration Bytes (16 bytes) Byte 0 1 2  3 4  5  6  7-15 Remark Equip. 0  Equip. 1 Protocol Speed Address Reserved, set to 00H Reserved, set to 00H Reserved, set to 00H Protocol:  0=USI0; 1=USI1; 2=USI2. Speed: 0=1200, 1=2400, 2=4800, 3=9600, 4=19.2k, 5=38.4k, 6=56k, and 7=115.2k bps. Address: Always is 00H. Actual Memory Card Type: See Memory Card Types table. Default Memory Card Type: The memory card type after reader has been powered-up or reset.  Equip. 0  -  Extended Configuration Byte 0 Bit  Value: 0  Value: 1 0  User card connector not  User card connector present
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  4-15present 1  Reserved for future use, always 0  2  SAM Board not present  SAM Board present 3  CTS not present    CTS present 4  Track 1 not present  Track 1 present 5  Track 2 not present  Track 2 present 6  Track 3 not present  Track 3 present 7  Latch not present  Latch present  Equip. 1  -  Extended Configuration Byte 1 Bit  Value: 0  Value: 1 0  Power fail not present  Power fail present 1 - 7  Reserved for future use, always 0.   • <CAN> (18H) – Pass through toggle COMMENT  Enable/Disable pass through function  FORMAT  The command characters are followed by an ASCII ‘P’ to enable/disable the pass through function.     • <7FH> – Warm Reset   COMMENT    Abort all current actions and cause the device to execute all initialization functions. The device will respond as it would for a "power up" cycle, but always returning a “:” (3AH).   • <09H> – Configuration Setting COMMENT    This command is used to set configuration in EEPROM. FORMAT  The command (09H) is followed by an at least 3 byte configuration setting command to set the configuration in EEPROM. The ePort G6 configuration can be set by this command or by the Configuration Setting Protocol. Please see “ePort G6 Configuration Guide” for details.   Following are brief introduction of configuration commands, please refer to “ePort G6 Configuration Guide” for the detail information.
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  4-16BRx (42h 52h x)  -  Set Baud Rate. x = '0' ~ '7'. DF0 (44h 46h 00h)  -  Set configuration to the Manufacture Default Setting. ECx (45h 43h x)  - Extended Configuration Report Enable/Disable. x is 'E' or 'D'. ESx (45h 53h x)  -  ES & SS Enable/Disable. x is 'E' or 'D'. (Only for Contactless MAG mode) EV0 (45h 56h 00h)  - EEPROM verify. FAx (46h 41h x)  -  Set Track 1 Prefix Code, x can be up to 5 bytes. (Only for Contactless MAG mode) Fax (46h 61h x)  -  Set Track 1 Suffix Code, x can be up to 5 bytes. (Only for Contactless MAG mode) FBx (46h 42h x)  -  Set Track 2 Prefix Code, x can be up to 5 bytes. (Only for Contactless MAG mode) Fbx (46h 62h x)  -  Set Track 2 Suffix Code, x can be up to 5 bytes. (Only for Contactless MAG mode) LCx (4Ch 43h x) - LRC Enable/Disable, x = 'E' or 'D'. Note: The LRC will be always disabled while the SS/ES was disabled. (Only for Contactless MAG mode) PCx (50h 43h x)  -  Set RS232 Protocol. x = '0' - '2'(30h - 32h). PHx (50h 48h x)  -  Set Power On character, x default is ':'. RE0 (52h 45h 00h)  -  Read all of EEPROM Data. RP0 (52h 50h 00h)  -  Respond current used baud rate and Protocol. SAx (53h 41h x)  -  Self-Arm Mode Enable/Disable, x is 'E' or 'D'. (Only for Contactless MAG mode) SPx (53h 50h x)  -  Set Track Separator. x = any one character. (Only for Contactless MAG mode) SNx (53h 4Eh x)  -  Set Serial Number, x is an 8-digits ASCII string. TAx (54h 41h x)  -  Set Track 1 ID, x = any one character. TBx (54h 42h x)  -  Set Track 2 ID, x = any one character. TCx (54h 43h x)  -  Set Track 3 ID, x = any one character. TKx (54h 4Bh x)  -  Set Transmitting Data Tracks PEx (50h 54h x) – Set pass through function  ITx (49h 54h x) – Set output interface type  TDx (54h 44h x) – Set MSR TTL data output polarity  TCx (54h 43h x) – Set MSR TTL clock output polarity  BCx (42h 43h x) – Set COM2 baudrate  RNxxxx (52h 4Eh xxxx) – Set Random seed
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  4-174.3 Contactless Mag Stripe Command Description    • P (50H) – Arm to Read   COMMENT    1. Clear read data buffers.   2. Transmit command acknowledgement (“^” 7EH).   3. Wait for card insert/withdrawal.   4. Transmit read acknowledgement ("^" Magnetic Stripe Card or ">" other media type) after card read.    After an "Arm to Read" command is received and acknowledged the only commands that will be accepted for execution are: <ESC> (Abort), ”$” (Status), LED control commands and Reset command. In self-arm mode, it is not necessary to send this command, if sent it will temporarily override self-arm mode.    • p (70H) – Arm to Read (Used for Manufacturing Test Only ) COMMENT    1. Clear read data buffers.   2. Transmit command acknowledgement (“^” 7EH). 3. Wait for card read. 4. If the card media is detected a "(" (28H) byte is sent, when media detect goes inactive a “)” (29H) byte is sent.   5. If another media detected transmit read acknowledge ">" after card read.   This is similar to the 'P' command but send ‘(‘ at start of magnetic stripe card data and ‘)’ at end.   • <ESC> (1BH) – Abort Arm to Read   COMMENT    1. Clear read data buffers.   2. Abort Arm to Read Command. 3. Transmit command acknowledge (“^” 5EH).  • Q (51H) – Transmit Track 1 data • R (52H) – Transmit Track 2 data COMMENT     1. Detect the card type (ISO/AAMVA/DMV) automatically and process data in the read buffer using detected card type format. 2. If error is detected, transmit proper error response ('*' or '+'), refer to “ The esponses to the Host”.  3. Else, transmit data in ASCII.
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  4-184.4 Contactless Smart Card Command Descriptions   • G (47H) – ISO14443 type protocol select COMMENT    Select ISO 14443 type A or B which manual command operated.  G[Type, 1 byte]  [Type] 0 (30h, ASCII Hex) - ISO14443 A 1 (30h, ASCII Hex) - ISO14443 B  Response:    ‘^’ – acknowledgement     ‘  *’ – No card response or No power on the antenna  • H(48H) – PayPass/Express card auto read function disable/enable COMMENT  Disable auto read function temporary if Self-Arm is enabling     H [Enable/Disable, 1 byte]  [Enable/Disable] 0 (30h, ASCII Hex) - Self-Arm disable 1 (31h, ASCII Hex) - Self-Arm enable  Response:    ‘^’ – acknowledgement       ‘*’ – No card response or No power on the antenna  • O (4FH) – Antenna power on COMMENT    Apply power on the antenna. This command is for manual command operation.  O[Baud rate, 1 byte]  [Baud rate] (optional)   0 (30h, ASCII Hex) – 106K (default, Mifare type A only) 1 (31h, ASCII Hex) – 212K (Mifare type A only) 2 (32h, ASCII Hex) – 424K (Mifare type A only) 3 (33h, ASCII Hex) – 848K (Mifare type A only)
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  4-19 Response:  ‘^’ – acknowledgement ‘*’ – Failed, the reader is in Self-Arm mode. The antenna power can not be turned off.  • o (6FH) – Antenna power OFF   COMMENT  Turn the antenna power off.  Response:  ‘^’ – acknowledgement ‘*’ – Failed, the reader is in Self-Arm mode. The antenna power can not be turned off.  • b (62H) – Request COMMENT  Request command.    b[Method, 1 byte]    -    If reader is set to ISO14443 type A  [Method] (optional)   0 (30h, ASCII Hex) – Request All 1 (31h, ASCII Hex) – Request Idle  Note: if the [Method] field does not appear in the request command, reader will set the request mode to “Request All” automatically.  b[AFI, 1 byte][Parameter, 1 byte] - If reader is set to ISO14443 type B  [AFI](optional) - Binary hex (00h to FFh), please refer to ISO 14443-3 for the detailed information [Parameter](optional) - Binary hex (00h to FFh), please refer to 14443 for the detailed information. Note: if the [AFI] and [Parameter] do not appear in the request command, reader will set the request mode to “Request All” automatically.  Response:    ATQA (2 bytes, type A, Binary Hex) or ATQB (16 bytes, type B, Binary Hex) if command executed successfully         ‘*’ – No card response or No power on the antenna  • c (63H) – Anticollision(type A)/Slot-Marker   COMMENT  In type A mode, the reader sends the Anticollision command to the card.
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  4-20In type B mode, the reader sends the Slot-Marker command to the card.  c[Cascade level, 1 byte] – if reader is set to type A  [Cascade level](optional) 0(30h, ASCII Hex) – Level 1 1(31h, ASCII Hex) – Level 2 2(32h, ASCII Hex) – Level 3   Note: if [Cascade level] does not appear in the Anticollision command, the reader will set to Level 1 automatically.  c[APn, 1 byte] – if reader is set to type B [APn] – Binary hex (01h to 16h), please refer to 14443-3 for the detailed information. Note: Slot-Marker is not a mandatory command for type B card.  Response:    If the command executed successfully, the reader returns PICC serial number for type A (4 bytes, Binary Hex)     Or           PICC send ATQB (12 bytes, Binary Hex) for type B   (PICC may not response ATQB, in this situation, reader respone ‘*’)       ‘*’ – No card response       ‘~’ – No power on the antenna  • f (65H) – Select(type A)/Attrib(type B) COMMENT  In type A mode, the reader sends the SELECT command to the card. In type B mode, the reader sends the ATTRIB command to the card.   f[Cascade level, 1 byte] – if reader is set to type A  [Cascade level](optional) 0(30h, ASCII Hex) – Level 1 1(31h, ASCII Hex) – Level 2 2(32h, ASCII Hex) – Level 3   Note: if [Cascade level] does not appear in the Select command, the reader will set to Level 1 automatically.  f[Parameter 1, 1 byte] [Parameter 2, 1 byte] [Parameter 3, 1 byte] [Parameter 4, 1 byte]         – if reader is set to type B
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  4-21  [Parameter 1](optional) – Binary Hex (00h to FFh) [Parameter 2](optional) – Binary Hex (00h to FFh) [Parameter 3](optional) – Binary Hex (00h to FFh) [Parameter 4](optional) – Binary Hex (00h to FFh) The setting of Parameter 1 to 4 should refer to ISO14443-3. If the [Parameter 1 – 4] do not appear in Attrib command, the reader set to default value.    Response:    If the command executed successfully, the reader returns       ‘^’ + SAK( 1 byte)    Or      ‘^’ + MBLI/CID(1 byte)       ‘*’ – No card response or No power on the antenna  • g (66H) – Mifare classical card authentication   (Support Mifare classical card only) COMMENT    Mifare classical card authentication.  f [Block number, 3 bytes][Key number, 1 byte] Authenticate the card with the key stored in EEPROM.  Or  f[Block number, 3 bytes][Key, 12 bytes] Authenticate the card with the key in [key field].  [Block number]   000 to 255 (30h30h30h to 32h35h35h, ASCII Hex)      [Key number]  0 to 9 (30h to 39h, ASCII Hex)  [Key]  0 to 9 or A to F (30h - 39h or 41h - 46h, ASCII Hex)  Response:    ‘^’ – acknowledgement       ‘*’ – No card response or No power on the antenna  • h (67H) – Mifare classical card read block (Support Mifare classical card only) COMMENT    Mifare classical card read command.
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  4-22g [Block number, 3 bytes]  [Block number]   000 to 255 (30h30h30h to 32h35h35h, ASCII Hex)  Response:  block data (16 bytes, Binary Hex) if command executed successfully       ‘*’ – No card response or No power on the antenna   • i (68H) – Mifare classical card write block (Support Mifare classical card only) COMMENT    Mifare classical card write command.  h[Block number, 3 bytes][Block data, 4 bytes or 16 bytes]  [Block number]   000 to 255 (30h30h30h to 32h35h35h, ASCII Hex) [Block data] Binary Hex from 0h to FFh Note: 4 bytes block data are for Mifare Ultralight. Others should use 16 bytes block data.  Response:    ‘^’ – acknowledgement       ‘*’ – No card response or No power on the antenna  • t (74H) – Mifare Value Operation (Support Mifare classical card only) COMMENT    Mifare classical card value operation command.  t[Block number, 3 bytes][Operation mode, 1 byte][Value, 4 bytes]  [Block number]   000 to 255 (30h30h30h to 32h35h35h, ASCII Hex) [Operation mode]   0 (30h, ASCII Hex) –Decrement 1 (31h, ASCII Hex) – Increment 2 (32h, ASCII Hex) – Restore [Value] Binary Hex from 0h to FFh
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  4-23 Response:    ‘^’ – acknowledgement       ‘*’ – No card response or No power on the antenna  • X (58H) – Mifare classical card activation (Support Mifare classical card only) COMMENT  Perform request/anticollision/select command to activate the card.    Response:    ATQA/serial number (6 bytes, Binary Hex) if command executed successfully       ‘*’ – No card response or No power on the antenna   • x (78H) – Card halt COMMENT  Card halt command.      Response:    ‘^’ – acknowledgement       ‘*’ – No card response or No power on the antenna   • J (6BH) – Activate PICC cpu card COMMENT    Activate PICC cpu card command. The Antenna POWER ON command has to be sent first.  Response:    ATS (type A) or PUPI (type B) if command executed successfully       ‘*’ – No card response or No power on the antenna  • j (6BH) – Load Mifare key (Mifare classical card only) COMMENT    Save up to 10 key sets for Mifare classical card application   Note. For security reason, there is no way to retrieve the key back.  i[Key number, 1 byte][Key data, 12 bytes]  [Key number]   0 to 9 (30h to 39h, ASCII Hex) [Key data]   0 to 9 or A to F (30h - 39h or 41h - 46h, ASCII Hex)
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  4-24Response:    ‘^’ – acknowledgement       ‘*’ – No card response or No power on the antenna  • k(6CH) – Mifare Reader Chip Direct Control COMMENT    Direct control the internal setting of Mifare reader chip  k[Command, 1 bytes] [Command] 0 (30h, ASCII Hex) - chip’s serial number. Return 4 bytes hex binary string 1 (31h, ASCII Hex) - chip’s product information field. Return 16 bytes hex binary string. 2 (32h, ASCII Hex) - chip’s register initial setting parameter. Return 32 bytes hex binary string.  Response:    ‘^’ – acknowledgement       ‘*’ – No card response or No power on the antenna  • y (79H) – Send DESELECT command COMMENT    Send ISO14443 layer 4 DESELECT command to card  Response:    ‘^’ – acknowledgement       ‘*’ – No card response or No power on the antenna  • Z (41H) – I/O to contactless CPU card with APDU format COMMENT  The command is used to pass an APDU to the card where both data and an ISO status are expected in the response.    Z[APDU, variant, 262 bytes max] [APDU]  Binary hex (00h to FFh)  If an APDU is included with command it is transmitted to the ICC, otherwise an acknowledgement (“^” 5EH) is returned and the reader will wait until the APDU is sent in the following message. If successful, the data from the ICC and the two byte SW1/SW2 ISO 7816-4 response are returned.  If unsuccessful, reader transmits '*'.    APDU Command Structure CLA INS P1 P2  P3 Data
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  4-25Lc or Le  (If Lc present)    APDU Response Structure Data (optional)  SW1 SW2 • z (7AH) – I/O to contactless card for block data exchange COMMENT  The command is used to pass a block data to a card.    z[CRC mode, 1 bytes][Wait time, 4 bytes][Block data, 384 bytes max.] [CRC mode] 0 (30h, ASCII Hex) – Block data contain 2 bytes CRC and enable CRC transmission.   1 (31h, ASCII Hex) – No CRC in block data and disable CRC transmission. [Wait time]   0000 to 9999 (30h30h30h30h to 39h39h39h39h, ASCII Hex) Waiting time in ms. [Block data]   Binary hex (00h to FFh), Maximum accept 384 bytes.  If successful, the data from the ICC are returned. If unsuccessful, reader transmits '*'.
ePort Programmer’s Manual                                  UDN PM059-U Rev. A  4-263.6 Responses to the Host   ^ (5EH)  Acknowledge. Acknowledges correct completion of most recent command   * (2AH)  Command was received correctly. But could not be completed.   + (2BH)  No Magnetic Stripe Card Data. Command was received correctly. ? (3FH)  Communication Error. Command was not received correctly.   ! (21H)  Invalid Command.   : (3AH)  Power On report. ~ (7Eh)  Unavailable Hardware not available to complete this request