Unikey Technologies 1SRV0C8 Smart Reader 2 User Manual TITLE Subtitle Copy

Unikey Technologies, INC Smart Reader 2 TITLE Subtitle Copy

Users Manual

Download: Unikey Technologies 1SRV0C8 Smart Reader 2 User Manual TITLE Subtitle Copy
Mirror Download [FCC.gov]Unikey Technologies 1SRV0C8 Smart Reader 2 User Manual TITLE Subtitle Copy
Document ID3814732
Application IDbtJvq/6waDrDGvT/ZH4aew==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize39.04kB (487987 bits)
Date Submitted2018-04-12 00:00:00
Date Available2018-04-12 00:00:00
Creation Date2017-09-07 16:42:06
Producing SoftwareMicrosoft® Word 2016
Document Lastmod2017-09-07 16:42:06
Document TitleDOCUMENT TITLE Subtitle Copy
Document CreatorMicrosoft® Word 2016
Document Author: Bert Hart

SR2 Installation
UG1004
This page is intended for installer use in the installation of the UniKey Smart
Reader 2.
Introduction
This guide will walk a professional installer through the steps needed to attach a UniKey
Smart Reader 2 (or SR2) to an access control panel. The SR2 supports 125 KHz proximity
cards as well as UniKey mobile credentials. Please review the information below to ensure
the reader is installed quickly and properly.
Grounding
•
•
Shield must run continuously from the reader to the panel. At the panel, the reader
ground, shield line, and earth ground must be connected together at a single point.
Do not ground the shield line at the reader end as this will create a potential ground
loop.
Power
•
A non-switching power supply at the panel is recommended to power the reader for
the highest noise immunity and best performance.
Voltage
•
•
•
The minimum reader voltage required is +6 VDC to a maximum of +16.0 VDC, and
12.0 VDC is recommended.
The reader will require 100 mA (typical @ 12 VDC) in standard mode, 220 mA (typical
@ 12 VDC) in advanced mode.
The reader is in standard mode by default, advanced mode can be configured via
in-app settings using the administrator app.
Connection
•
Connections must be in accordance with NFPA 70. DO NOT connect to a
receptacle controlled by a switch.
Mounting the Reader
•
•
•
If the unit is used to control a door or pedestrian gate, locate the unit as near as
practical to the entry point. If the unit is mounted on or in a wall adjacent to the
entry point, be sure the wall is sturdy. The repeated shock and vibration from a
slamming access door or spring- loaded pedestrian gate must be isolated from the
unit.
Never mount the reader directly on a moving door or gate.
Choose a well-lit location near the controlled opening. Wiring access for power,
network, and earth ground must be available to the mounting location.
Copyright ©2017 UniKey Technologies. All rights reserved.
SR2 Installation
UG1004
Mounting
•
Both the Mullion and Single-gang readers can be mounted on a wall or any suitable
flat surface.
Reader Wiring
WIEGAND
CONDUCTOR
Purpose
RED
DC +6-16 VDC
BLACK
Ground
GREEN
Data 0
WHITE
Data 1
BROWN
Red LED
ORANGE
Green LED
YELLOW
Card Present
BLUE
Beeper
DRAIN
Shield Ground
Current Draw: 100mA (typical @ 12VDC)
Certifications
•
•
FCC Compliance Statement: This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference
that may cause undesired operation.
Product can be used without license conditions or restrictions in all European Union
countries, including Austria, Belgium, Denmark, Finland, France, Germany, Greece,
Ireland, Luxembourg, The Netherlands, Portugal, Spain, Sweden, and the United
Kingdom, as well as other non-EU countries, including Iceland, Norway, and
Switzerland.
Copyright ©2017 UniKey Technologies. All rights reserved.
SR2 Installation
UG1004
Revision History
Revised By
RLJ & EKC
Date
9/7/2017
Version
1.0
Change Summary
Initial Release
Copyright ©2017 UniKey Technologies. All rights reserved.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Page Count                      : 3
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Microsoft® Word 2016
Title                           : DOCUMENT TITLE.Subtitle Copy
Creator                         : Bert Hart
Creator Tool                    : Microsoft® Word 2016
Create Date                     : 2017:09:07 16:42:06-04:00
Modify Date                     : 2017:09:07 16:42:06-04:00
Document ID                     : uuid:33E94290-55BF-4EFD-8081-9D870FBA351B
Instance ID                     : uuid:33E94290-55BF-4EFD-8081-9D870FBA351B
Author                          : Bert Hart
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ANJI-1SRV0C8

Navigation menu