Unimo Technology PZ-400NW FM HANDHELD TRANSCEIVER User Manual PZ Service Manual R1A
Unimo Technology Co., Ltd. FM HANDHELD TRANSCEIVER PZ Service Manual R1A
Users Manual
Maintenance Manual PZ-series Portable Radio PZ-400, PZ-100 Maintenance Manual TABLE OF CONTENTS SPECIFICATIONS ................................................................................................................................................. 4 MODEL: PZ-100NW ...................................................................................................................................... 4 MODEL: PZ-400NW ...................................................................................................................................... 5 FEATURES ............................................................................................................................................................. 7 CONTROLS & INDICATORS ............................................................................................................................... 8 Controls ........................................................................................................................................................... 8 Indicators ....................................................................................................................................................... 10 BATTERY PACKS................................................................................................................................................ 11 Installing the Battery Pack............................................................................................................................. 11 Removing the Bttery Pack ............................................................................................................................. 12 Charging the Battery Pack ............................................................................................................................. 12 RADIO OPERATIONS......................................................................................................................................... 13 Installation and Removal of Antenna............................................................................................................. 13 Power On/Off ................................................................................................................................................ 13 Transmission.................................................................................................................................................. 13 Receiving ....................................................................................................................................................... 14 Changing Channels........................................................................................................................................ 14 Adjusting Transmitting Power....................................................................................................................... 14 SCAN Operating mode.................................................................................................................................. 14 Emergency Call ............................................................................................................................................. 15 VOX .............................................................................................................................................................. 16 Maintenance Manual Monitor .......................................................................................................................................................... 16 Dual PTT (Home Channel) mode .................................................................................................................. 16 Subtone .......................................................................................................................................................... 16 2 Tone Function ............................................................................................................................................. 18 Call Function ................................................................................................................................................. 18 Compander..................................................................................................................................................... 20 Scramble ........................................................................................................................................................ 20 Stun / Revive Function .................................................................................................................................. 20 BCL/BCLO.................................................................................................................................................... 20 TOT ............................................................................................................................................................... 20 Key Lock ....................................................................................................................................................... 21 Cloning Function ........................................................................................................................................... 21 Maintenance Manual SPECIFICATIONS MODEL: PZ-100 GENERAL Dimensions(Less Antenna) H x W x D Weight Radio (less battery) with battery (2600mAH) Programmable Channels Channel Spacing Power Source Current Drain (maximum) Receive Standby mode Receive Full Audio Transmit at 5 Watts 112.2 × 56mm × 31.9 mm 16 Channels 12.5 / 25 kHz 7.5V DC Rechargeable Li-ion 2600 mAH battery pack 60 mA 350 mA 1.6 A TRANSMITTER Frequency Range Frequency Stability RF Power Output Spurious and Harmonic FM Hum and Noise Audio Distortion Audio Frequency Response 136 ~ 174 MHz ± 2.5 ppm (-30 to +60 ) 5 Watts / 2 Watts -65dB 40dB (12.5 kHz), 45dB (25 kHz) 5% maximum +1, -3dB from 6dB per octave pre-emphasis Characteristic from 300 ~ 3000Hz ℃ RECEIVER Frequency Range Sensitivity Squelch Sensitivity Selectivity Spurious and Harmonic Rejection Inter-modulation FM Hum and Noise Audio Output Power Audio Distortion Audio Response 136 ~ 174 MHz .282uV 12 dB SINAD .25uV 10dB SINAD 60dB (12.5KHz), 65dB(25KHz) 70dB 60dB 40dB 1 Watt across an 16-ohm load Less than 5% at rated output +1, -3 dB from 6dB per octave de-emphasis Characteristic from 300 ~ 3000Hz Maintenance Manual MODEL: PZ-400 GENERAL Dimensions(Less Antenna) H x W x D Weight Radio (less battery) with battery (2600mAH) Programmable Channels Channel Spacing Power Source Current Drain (maximum) Receive Standby mode Receive Full Audio Transmit at 5 Watts 112.2 × 56mm × 31.9 mm 512 Channels 12.5 / 25 kHz 7.5V DC Rechargeable Li-ion 2600 mAH battery pack 60 mA 350 mA 1.6 A TRANSMITTER Frequency Range Frequency Stability RF Power Output Spurious and Harmonic FM Hum and Noise Audio Distortion Audio Frequency Response 400 ~ 470 MHz ± 2.5 ppm (-30 to +60 ) 4 Watts / 2 Watts -65dB 40dB (12.5 kHz), 45dB (25 kHz) 5% maximum +1, -3dB from 6dB per octave pre-emphasis Characteristic from 300 ~ 3000Hz ℃ RECEIVER Frequency Range Sensitivity Squelch Sensitivity Selectivity Spurious and Harmonic Rejection Inter-modulation FM Hum and Noise Audio Output Power Audio Distortion Audio Response 400 ~ 470 MHz .282uV 12 dB SINAD .25uV 10dB SINAD 60dB (12.5KHz), 65dB(25KHz) 70dB 60dB 40dB 1 Watt across an 16-ohm load Less than 5% at rated output +1, -3 dB from 6dB per octave de-emphasis Characteristic from 300 ~ 3000Hz Maintenance Manual MODEL NUMBER To identify the model number of PZ-series Radio is as followings PZ – 400 Identification number of radio Frequency Band manufactured by UNIMO Model Number Description PZ - 100 PZ - 400 Frequency band: 136 – 174 Mhz, Frequency band: 400 – 470 Mhz, PZ-SERIES RADIO PACKAGE NUMBERS Package Number Description PZ10XXXE PZ10GXXE PZ10XBXE PZ10GBXE 136 – 174Mhz PZ series radio 136 – 174Mhz PZ series radio with GPS 136 – 174Mhz PZ series radio with Bluetooth 136 – 174Mhz PZ series radio with GPS and Bluetooth PZ10XXWE PZ10GXWE PZ10XBWE PZ10GBWE 136 – 174Mhz PZ series radio (Waterproof model) 136 – 174Mhz PZ series radio with GPS (Waterproof model) 136 – 174Mhz PZ series radio with Bluetooth (Waterproof model) 136 – 174Mhz PZ series radio with GPS and Bluetooth (Waterproof model) PZ40XXXE PZ40GXXE PZ40XBXE PZ40GBXE 400 – 470Mhz PZ series radio 400 – 470Mhz PZ series radio with GPS 400 – 470Mhz PZ series radio with Bluetooth 400 – 470Mhz PZ series radio with GPS and Bluetooth PZ40XXWE PZ40GXWE PZ40XBWE PZ40GBWE 400 – 470Mhz PZ series radio (Waterproof model) 400 – 470Mhz PZ series radio with GPS (Waterproof model) 400 – 470Mhz PZ series radio with Bluetooth (Waterproof model) 400 – 470Mhz PZ series radio with GPS and Bluetooth (Waterproof model) Maintenance Manual FEATURES PZ-series radio is designed for a rugged, lightweight and it can be provided for powerful sound and for better performance of conversation distance & sound quality. The new PZ-series radio provides reliable service in the industrial fields and public places for the safety & convenience of users. The PZ-series radio is offered with several packages available with respect to the options (GPS function, Bluetooth fuction). The radio is programmed using a Personal computer and program cable connected to the phone jack on the side of the radio. 512 channels are selectable. Call Guard Squelch of standardized 53 CTCSS / 104 DCS Tones. Scramble function of frequency Inverter Type Compander function Dual Tone Modulation Frequency (DTMF) Selectable Channel Spacing (12.5kHz / 25KHz) Normal Scanning and Priority Scanning Time-Out Timer (TOT) 2-Tone Paging BCL (Busy Channel Lock) / BCLO (Busy Channel Lock Out) High/Low Power Switching 10 Step Squelch Control Using RSSI (0~9) Remote Radio Stun/Revive (Use 5 Tone) Monitor VOX Easy Cloning USB PC Programming PC Tuning GPS function (Option) Bluettoth function (Option) Maintenance Manual CONTROLS & INDICATORS The following section provides a description of the controls and Indicators for the PZ-series radio. Detailed operating instructions can be found the later chapter. Controls On/Off Volume Switch Turn the knob of Volume Switch clockwise to turn the Radio on and if turning the Switch to the opposite direction, the Radio is turned off. The audio volume level can be adjusted by turning the Volume Switch and when adjusting the volume, please refer to the index mark indicated nearby the Volume knob. The knob of volume doesn’t exist for the GPS model of PZ-series radio. In this case, press and hold the “F4” button then the radio is turn ON. And during the operation press and hold “F4” button then the radio is turn OFF. Maintenance Manual Channel Select Switch Turn the knob of Channel Select Switch clockwise to increase the channel number and if turning the switch to the opposite direction then decrease the channel number. The channel numbers are preprogrammed using by PC program. The channel selections also can be changed by up and down buttons on front side of the radio. PTT Button The radio is converted to transmission mode and transmitting the RF power by pressing and holding the PTT button on the side of the radio. The status indication LED lights in red color. And the radio is converted to receive standby mode by release the PTT button. It is recommended to talk about 5~7cm away from the microphone for using in better sound quality and for better voice communication. Monitor Button The receiving status of the selected channel can be checked using by “Monitor” button. Normal Mode: During the press and holding the “Monitor” button for about 2 seconds, it is possible to check the receiving status of the channel. Continuous Mode: Press and holding the “Monitor” button for more than 2 seconds, a beep tone is heard along with a noise and the monitor function is continuously maintained. If pressing the Monitor button again, the monitor function will be released. Emergency Button Press the “Emergency” button in an emergency situation, an emergency siren sound will be heard through the speaker in the Radio. And the Radio will transmit an emergency signal to the party through the emergency channel. Menu Button (Scan Button) If pressing Menu button for about 2 seconds, the Scan operation is proceeded and by pressing the Menu button again, the Scan operation is released. Speaker Microphone Jack The speaker microphone Jack on the side of the radio will be used for interface with external speaker microphone accessories and making PC programming/Cloning/Tuning, Maintenance Manual Indicators Status Indication LED The users can be recognized the current status of PZ-series radio by the color of LED. The status indication will be as followings. When the transmitting status is normal, the red LED will be ON. When the receiving status is normal, the green LED will be on. When the CTCSS tone or DCS code is not being received due to mismatch, the green LED will be blinked. When the low battery condition, the red LED will be blinked and an alert tone will be generated. Graphic LCD The one line of 14 characters (7 characters for Korean language) graphic type of LCD uses for indication of several kinds of status of the radio. The Group/Channel number or the frequency or the preprogrammed name of the channel will be displayed on the LCD. And provides the menu operation. In addition there are 9 status ICON indicators, also can be displayed the several kinds of status of the radio. ③ ② ① ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ① ② ③ ④ ⑤ Signal strength indicator is ON when the radio receives RF signal. It can be divided for 4 kinds of signal levels. In case of good signal, all 4 the signal strength indicator bar is ON. Transmitting power indicator is ON when the Low power mode is selected. 2Tone, 5Tone mode indicator is ON when the channel is programmed for 2Tone, 5Tone operation. VOX indicator is ON when the VOX mode is activated. Scrambler mode indicator is ON when the scrambler function is activated. 10 Maintenance Manual ⑥ ⑦ ⑧ ⑨ Compander mode indicator is ON when the compander function is activated. Radio generates a several kinds of alert tones when the alert tone function is activated. This indicator is OFF when this function is deactivated. Lock indicator is ON when the radio is locked. Battery capacity indicator. All the indicators are ON when the battery is full charged. After in use the battery capacity indicator inner the box is OFF one by one. Outer box is blinked when the battery power is low and need to charging ⑩ The one line of 14 characters (7 characters for Korean language) graphic LCD area. The LCD backlighting can be programmed to turn on anytime a button is pressed. It will remain on for a programmable length of time after the button is released. And it may be programmed to remain off all times. BATTERY PACKS The following battery pack is available for use with the PZ-series radio. PBX-2260LA: Rechargeable Battery Packs (2600mAH Li-ion). The PX-Series Radio receives power from high-performance Li-ion battery. The battery is safe, of highperformance and highly reliable. Using the enclosed standard charger makes it possible to get sufficient efficiency and lifetime of the battery. ☞ Battery Packs used with the PZ-series radio must be supplied by UNIMO Technology Co., Ltd. CAUTION Installing the Battery Pack Ensure the ON/OFF volume switch is set to OFF position 11 Maintenance Manual of the radio. Hold the radio and battery pack with the back of them facing you. See Figure Align the hook back of the radio with the hook front side of the battery pack Press and slide the battery pack fully upper side of the radio until the battery release latch click into place. Removing the Bttery Pack Ensure the ON/OFF volume switch is set to OFF position of the radio. Press down the release latch and slide the battery pack down side of the radio. See Figure Charging the Battery Pack New batteries or batteries that have been stored for a long time period of time, should be fully charged before placing into service. Low battery voltage will shorten the talk range and will make the performance of radio worse. When the battery pack requires charging the battery indicator in the LCD will blink and the radio will sound a high pitch tone every seconds. How to Charging Plug the charger (CHZ-260FB) into the electricity power outlet for AC220V. The charger (CHZ-260FB) has two slots. When charging the radio with the battery installed, insert the radio into front slot of the charger after power off. When charging the battery only, insert battery into rear slot of the charger. Although the green LED is on after full charge, please continue the charging for 30 more minutes for the complete full charge. During the charging red LED is turn ON 12 Maintenance Manual After complete charging Error condition During maintaining charge ☞ CAUTION green LED is turn ON red LED is blinks green LED is turn ON Charger used with battery packs must be supplied by UNIMO Technology Co., Ltd. Charging the battery on the other manufacturer’s can cause unexpected damage of the battery and the radio RADIO OPERATIONS Installation and Removal of Antenna The Figure shows the installation and removal method of antenna. Turn the antenna clockwise for installation of antenna and in order to remove the antenna from Radio, turn the antenna counterclockwise. ☞ CAUTION` When installation of the antenna, giving a strong pressure to the Radio or pulling the antenna from Radio with a strong power can make damage on the antenna connector, which may cause the Radio to have critical problem. Power On/Off Turn Power switch clockwise and as soon as power is supplied, a “beep” sound is heard and the model name of the radio is displayed and the Radio enters into the previous latest state. If the user ID is preprogrammed than this is displayed on the LCD. ☞ CAUTION` If turning power on by pressing a button on Radio, the Radio may enter into a special mode, in this case, the transmitting and receiving of radio may not be possible. Don’t use the Radio for the other purpose apart from the above. Transmission Pressing the PTT button on the left side of Radio for transmission. The DTMF or 5 Tone is transmitted according to the setting of the radio. During this time voice communication will not be made and after that the red LED is turned on and voice is transmitted. For voice communication in the best sound quality, it is recommended to talk 5~10cm away from the radio. 13 Maintenance Manual ☞ CAUTION` If transmitting consecutively for more than a certain time when setting of BCLO function and TOT function, the transmission can be forcibly interrupted for other users. Receiving The radio operates as a receiving standby mode except for the transmitting period. User can adjust the volume by using the volume switch. The green LED is turn ON when the radio receives the RF signal and can heard the transmitting voice. According to the setting of transmitting radio, can be heard the DTMF tone or 5 Tone and displayed caller ID on the LCD. If frequency is same as current channel but sub-tone is not same as current setting than the green LED blinks. In order to check if the current channel is in use, press the Monitor button (M) on the left side of Radio. If pressing the Monitor button (M) for about 2 seconds, the monitor function is activated with a “beep” sound. To release from the monitor function, press the monitor button shortly. Changing Channels Channel Switch and “F1”/”F2” buttons are used for changing channels. Turn the Channel switch clockwise or press “F1” button to increase the channel number with beep sound. And Turn the Channel switch counter-clockwise or press “F2” button to decrease the channel number with beep sound. Press and hold “F1”/”F2” button then changing channel continuously. When the channel is changed, channel number or channel names are displayed on the LCD. The channel frequencies include sub-tone information are pre-programmed by PC program. Adjusting Transmitting Power The transmitting power can be selected to High-Power mode or Low-Power mode. The user can change the transmitting power on the Menu mode. When Low-Power mode is selected, the indicator icon “L” is displayed on the LCD. By changing the power to Low-power mode under a good communication condition, the user can extend the battery life. SCAN Operating mode SCAN function is executed with a “beep” sound when pressing the “F3” and “F2” button consecutively within 0.5 seconds during the standby state. The radio will change the scan channel and check the RF signal at regular interval. Pressing “F4” button then SCAN function can be deactivated. 14 Maintenance Manual A scan channel list must be created before SCAN can be used. The radio will not go into SCAN mode where no scan channels are programmed. The scan channel list can be established in PC program of Menu mode. Normal Scan Once SCAN is activated, the radio will perform a normal scan mode. When the scan channel list is NS1, NS2 and NS3 on the normal scan mode, the radio proceeds to scan in the sequence of NS1, NS2, NS3, NS1, NS2, NS3.... During the receiving mode user can move to the next channel by pressing the “F1” or “F2” buttons. And delete current receiving channel temporarily from the scan channel list. If getting out of SCAN Mode or turning on power again, the list deleted temporarily is returned back to the original. Priority Scan As soon as priority scan channel is detected, the radio will change priority scan mode. When the scan channel list is NS1, NS2, NS3 and priority scan channel is PS, the radio proceeds to scan in the sequence of PS, NS1, PS, NS2, PS, NS3, PS, NS1.... During receiving signal through common channel, the radio scans the priority channel periodically. And if the radio detects the signal on the priority channel, it starts to receive the signal from the priority channel. During the receiving mode user can move to the next channel by pressing the “F1” or “F2” buttons. The user can delete current receiving channel temporarily from the scan list and at that time, user can move to the next channel. But the radio receives the signal from priority channel then it will not be deleted. Transmitting Pressing the PTT button cause the radio to transmit on selected channel frequency and to stop the SCAN mode. And the selected channel frequency can be established in PC programmer. Home channel. Last receiving channel Current scan channel. Emergency Call If pressing the EMR key, radio transmitting the emergency alert tone or 5-Tone message in Sell-call mode. Also user can hear the emergency alert tone. If the radio is set up in repeated mode, the radio 15 Maintenance Manual transmitting the emergency alert tone periodically. This function can be performed when SCAN is activated. VOX The VOX function is set up by Pc-Programmer and without pressing the PTT key, the voice signal is transmitted through microphone. Monitor In order to open the squelch compulsorily, press the MON key. If pressing the MON key for more than 2 seconds, the squelch is opened continuously with a “beep” sound. If you want to get out of this mode, press the MON key shortly once again, or turn off and on the power. Dual PTT (Home Channel) mode If pressing the EMR + PTT key successively, the radio generates a “beep” sound and makes the conversion to the HOME channel designated by PC Programmer. “[HM]” message is displayed on the left side of the LCD. In order to release from the Dual PTT function, press the EMR + PTT key once again, or turn off and on the power. This function can be performed when SCAN is activated. Subtone The radio can be programmed for CTCSS encode/decode tone frequencies and DCS code. CTCSS tone frequency A list of standard tone frequencies for CTCSS tone are as shown below. No. Frequency No. 67.0 15 Frequency 110.9 No. 29 Frequency 179.9 No. 43 Frequency 196.6 16 Maintenance Manual 10 11 12 13 14 71.9 74.4 77.0 79.7 82.5 85.4 88.5 91.5 94.8 97.4 100.0 103.5 107.2 16 17 18 19 20 21 22 23 24 25 26 27 28 114.8 118.8 123.0 127.3 131.8 136.5 141.3 146.2 151.4 156.7 162.2 167.9 173.8 30 31 32 33 34 35 36 37 38 39 40 41 42 186.2 192.8 203.5 210.7 218.1 225.7 233.6 241.8 250.3 69.3 159.8 183.5 189.9 44 45 46 47 48 49 50 51 52 53 199.5 206.5 229.1 254.1 165.5 171.3 177.3 60.7 62.5 64.7 DCS code A list of standard tone frequencies for CTCSS tone are as shown below. No. DCS Code No. 023 025 026 031 032 27 28 29 30 31 DCS Code 165 172 174 205 223 No. 53 54 55 56 57 DCS Code 413 423 431 432 445 No. 79 80 81 82 83 DCS Code 731 732 734 743 754 17 Maintenance Manual 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 043 047 051 054 065 071 072 073 074 114 115 116 125 131 132 134 143 152 155 156 162 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 226 243 244 245 251 261 263 265 271 306 311 315 331 343 346 351 364 365 371 411 412 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 464 465 466 503 506 516 532 546 565 606 612 624 627 631 632 654 662 664 703 712 723 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 036 053 122 122 212 225 246 252 255 266 274 325 332 356 446 452 454 455 462 523 526 2 Tone Function The radio encodes the received 2 Tone before receiving the transmission voice when current channel is activated 2 Tone. If the 2 Tone corresponds with that of current channel then radio receives the corresponding 2 Tone normally. (In case of No Tone or the corresponding Sub-tone) Call Function The radio can be called the individual radio or Group of radio using by Call Function. The radio can be 18 Maintenance Manual programmed for 30 different IDs and names using by PC programmer. The radio enters Call mode when pressing the “F3” and “F1” button simultaneously during the standby mode. The radio returns the standby mode when pressing the “F4” button. When the Call mode is activated then call IDs are displayed on the LCD and change next IDs using by channel select switch. Individual Call Enters the Call mode using by press the “F3” and “F1” buttons simultaneously. Select the Call ID that the user wants to communicate. To initiate a call, the user press the “F1” button then the radio transmits the calling signal. And the caller’s ID was displayed on receiving radio. The receiving radio enters the Call mode when receives the calling signal. Individual Communication Enters the Call mode using by press the “F3” and “F1” buttons simultaneously. Select the Call ID that the user wants to communicate. To initiate a communication, the user press the PTT key then the radio transmits the calling signal after that transmitting the voice. Group Call Enters the Call mode using by press the “F3” and “F1” buttons simultaneously. Select the Group Call ID that the user wants to communicate. The Group IDs can be programmed using by PC programmer. To initiate a call, the user press the “F1” button then the radio transmits the calling signal. And the caller’s Group ID was displayed on receiving radios. 표시) Group Communication Enters the Call mode using by press the “F3” and “F1” buttons simultaneously. Select the Group Call ID that the user wants to communicate. To initiate a communication, the user press the PTT key then the radio transmits the calling signal after that transmitting the voice. 19 Maintenance Manual Compander The compander function is used for improving the voice quality. When transmitting, it transmits compressed voice and when receiving, it expands the compressed voice, which is for improvement of communication quality. Scramble The scramble function is used to protect the radio from overhearing of the other radio that is used same frequency. The scramble can be activated by Menu mode. Although the power is turned off and on, this function is maintained. Indicator Icon “SCR” is ON when the scramble is activated. Stun / Revive Function It is possible to stun and revive the radio with Stun ID from the control center. If the radio receives Stun ID then all of the key and buttons of the radio doesn’t perform. In this state, pressing the PTT buttons then can be heard alert sound. And although the power is turned off and on, this state is maintained. If the radio receives Revive ID from the other radio, the Radio returns back to the original with a ”beep” sound. BCL/BCLO BCL/BCLO function is used not to interrupt the other users who are using the same frequency. If BCL/BCLO is activated then transmitting is prohibited from the same channel that was used for others. In this case, alert sound is heard and message is displayed on the LCD. BCL(Busy Channel Lock) : Prohibit transmission from the same frequency. BCLO(Busy Channel Lock Override) : Prohibit transmission in case of different sub-tone. TOT TOT function is used to prevent from using one channel continuously for a long time. If the radio transmits over the TOT time continuously, the transmitting is automatically stopped and an alert sound is generated. If a Penalty time is set up then the radio makes transmitting normally after the penalty time. The TOT and penalty time can be setup by PC programmer. 20 Maintenance Manual Key Lock Pressing and holding the “F4” buttons over 2 seconds then Key Lock is activated when the radio is standby mode. And the indicator Icon is ON. Up/Down and Menu buttons doesn’t operate during this function is activated. Key Lock function can be deactivated, pressing the “F4” buttons once more when the Key Lock is activated. Cloning Function The personality data of radio such as frequency/Tone/Scan can be copied to other radio directly using by cloning function. The following section provides a description of 2 different kind of cloning function. Wire Cloning Prepare the cloning cable (PECLONA) for PZ-series radio. The original radio should be turned on with pressing the PTT button and “C-Clone Mode” message will be displayed on the LCD. The radio to be copied should be in the standby mode for receiving. Ear/Microphone jack of original radio connect to the target radio through cloning cable. If pressing the “F1” button of the original radio, the copy is executed. After completing the copy, “Clone complete” message will be displayed on the LCD. Removing the cloning cable, turn off and on the power of 2 Radios. Please use the radio after checking if the copy is succeeded without problem. Wireless Cloning The original radio and target radio should be turned ON with pressing the PTT button. Press “F2” button of original radio and select a “M-Clone Mode”, and press “F2” button and select a “M-Rx Mode”. If pressing the “F1” button of the original radio, the copy is executed. After completing the copy, “MClone complete” message will be displayed on the LCD. ☞ If the Cloning is made into other maker’s Radio, a critical malfunction can happen. CAUTION` 21 Acknowledging Special Precautions and the FCC Notice Cautions. Modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC compliance Information This device complies with part 15 of FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received. Including interference that may cause undesired operation. Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, Pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio Frequency energy and, if not installed and used in accordance with th einstruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, whic h can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: > Reorient or relocate the receiving antenna. > Increase the separation between the equipment and receiver > Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. RADIO FREQUENCY ENERGY SAFETY INFORMATION This UNIMO transceiver has been tested and complies with the standards listed below, in regards to radio Frequency(RF) energy electromagnetic energy(EME) generated by the transceiver FCC RF exposure limits for Occupational use only. RF exposure limits adopted by the FCC are generally based on recommendations from the national council on radiation protection and measurement, & the American National National Standards Institute. > FCC OET Bulletin 65 Edition 97-01 Supplement C > American National Standards Institute(C95.1-1992) > American National Standards Institute(C95.3-1992) WARNING This UNIMO transceiver generates RF EME while transmitting. RF EME(Radio Frequency Electric & Magnetic Energy)has the potential to cause slight thermal, or heating effects to any part of your body less than the recommended distance from this radio transmitter's antenna. RF energy exposure is determined primarily by the distance to and the power of the transmitting device. In general, RF exposure is minimized when the lowest possible power is used or transmission time is kept to the minimum required for consistent communications, and the greatest distance possible from the antenna to the body is maintain. The transceiver has been designed for and is classified for Occupational use only. Occupational/controlled exposure limits are applicable to situations in which persons are exposed to RF energy as a consequence of their employment, and such persons have been made aware of the potential for exposure and can exercise control over their exposure. This means you can use the transceiver only if you are aware of the hazards of operating a transceiver and are familiar in ways to minimize these hazards. This transceiver is not intended for use by the general public in uncontrolled environments. Uncontrolled environment exposure limits are applicable to situations in which the general public may be exposed to RF energy ,or in which the persons who are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot exercise control over their exposure The following list provides you with the information required to ensure that you are aware of RF exposure and of how to operate this transceiver so that the FCC RF exposure limitations are not exceeded. > While transmitting(holding the PTT switch), always keep the antenna at least 2.5cm (1 inches) from your body or face ,as well as from any bystanders > Do not transmit for more than 50% of the total transceiver use time; transmitting over 50% of the total use time may exceed the limits in accordance to the FCC RF exposure requirements. Nominal transceiver operation is 5% transmission time,5% reception time, and 90% stand-by time > Use only the specified antenna for this transceiver; this may be either the antenna provided with the transceiver or another antenna authorized by UNIMO. Use only UNIMO authorized accessories (antennas, battery packs, belt clips, Speaker/Mics or headsets etc.): When worn on the body, always place the radio in a UNIMO recommended clip or carrying case meant for this product. The use of other than recommended or approved body-worn accessories may result in RF exposure levels which exceed the FCC's occupational /controlled environment RF exposure limits. CAUTION To ensure that your exposure to RF EME is within the FCC limits for occupational use, you must observe and adhere to the above points. Electromagnetic Interference Compatibility Electronic devices are susceptible to electromagnetic interference(EMI)if they are not adequately shielded or designed for electromagnetic compatibility. Because this transceiver generates RF energy, it can cause interference to such equipment. >Turn OFF your transceiver where signs are posted to do so. Hospitals and health care facilities use equipment that is sensitive to electromagnetic radiation. > Turn OFF your transceiver while on board an aircraft when so instructed, Use of the transceiver must be in accordance with airline regulations and/or crew instructions. IMPORTANT Safety Instruction: 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this equipment near water. 6) Do not using near any heat sources such as radiators, heat resisters, stove, or other equipment that produce heat. European Union Regulatory Notice Compliance with these directives implies conformity to harmonized European standards (European Norms) that are listed in the EU Declaration of Conformity issued by HP for this product or product family. This compliance is indicated by the following conformity marking placed on the product. CE RF Radiation Exposure Statement: Caution This equipment complies with European RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.This transmitter must not be colocated or operating in conjunction with any other antenna or transmitter.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-701 Create Date : 2009:09:11 10:20:29Z Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2010:01:16 11:44:31+09:00 Metadata Date : 2010:01:16 11:44:31+09:00 Format : application/pdf Creator : Owner Title : Microsoft Word - PZ - Service Manual R1A.doc Producer : GPL Ghostscript 8.15 Document ID : uuid:91a7cd7b-483f-4031-a67b-0ff116ce67a8 Instance ID : uuid:dbbee218-b7bd-4fb4-94ab-ca6412e44231 Has XFA : No Page Count : 26 Author : OwnerEXIF Metadata provided by EXIF.tools