United Integrated Services WAC-110 WIRELESS ALARM CONTROLLER User Manual

United Integrated Services CO., LTD. WIRELESS ALARM CONTROLLER Users Manual

Users Manual

Download: United Integrated Services WAC-110 WIRELESS ALARM CONTROLLER User Manual
Mirror Download [FCC.gov]United Integrated Services WAC-110 WIRELESS ALARM CONTROLLER User Manual
Document ID1132493
Application IDRSXXqf4XrRTsNKtvCmqliA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize7.52kB (93991 bits)
Date Submitted2009-07-01 00:00:00
Date Available2009-07-02 00:00:00
Creation Date2009-06-16 14:33:34
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2009-06-16 14:33:34
Document TitleMicrosoft Word - 091164R_英文_使用說明書_WAC-110_無線警報器_2009_06_02.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: anitachou

Wireless Alarm Controller User's Manual
Product Name:
Model No:
Input Power:
Wireless Alarm Controller
WAC-110
AC 120V, 50/60Hz
Features Description :
1.
Base on wireless way to receive from repeater alarm status. Be able to use many
WAC-110 (Wireless alarm controller) to provide wider range of alarm that increases
protection of everyday.
2. WG-110 (Wireless Gateway) receives alarm information from WCS-110 (Wireless contact
sensor) or WMS-110 (Wireless motion sensor) …etc. WG-110 (Wireless Gateway)
transmission alarm state to WR-110 (Wireless Repeater).When WR-110 (Wireless Repeater)
pass alarm state toWAC-110(Wireless alarm controller) then alarm sound out.
3. Easy install, only Insert the WCS-110 (Wireless contact sensor) to power plug. If power
lose the WCS-110 (Wireless contact sensor)well send RF signal and alarm sound
4. If alarm the panel limpid button red LED well flesh. Push the button then alarm is ceased.
5. 100dB sound of alarm.
6. Easy link, when install at the first time to press the set button on the side of product
binding with repeater.
Outline Dimensions :
Feature Locator ::
1. State of LED window
2. Button and red LED
3. Alarm voice hole
4. (SET) Setting button
5. America power plug
Installation Hints ::
1.
First time when WAC-110 into the power plug., please wait 3~5 minute let the battery of
WAC-110 charge in advance.
2. Linking way with WR-110 needs to press set button of side of WAC-110. Continuing press set
button of bottom of WR-110. Wait for 30sec. to 1 minute. If linking success indicator light
of LED will flash three times. If linking fail, indicator light of LED will flash two times.
3. WCC-110 can control WAC-110 that send out the sound of alarm or stop. Please reference the
user manual of WCC-110 when setting.
4. If pull out power adapter from the plug of WAC-110 (Wireless alarm controller),
WAC-110 will dispatch wireless alarm which send out the sound of alarm six times and
red LED will flash.
5. WAC-110 (Wireless alarm controller) sends out the sound of alarm. High luminance LED
red light will flash. IF stops the sound please press transparent button of front panel.
Troubleshooting:
1. Problem :
When link with WR-110 (Wireless repeater), there is no display of LED
Indicator light for WAC-110 (Wireless alarm controller) to flash two or
three times.
Solution : a. Be able to use small night light to confirm the plug power valid.
b. Internal golden electric capacity electric power of WAC-110 may be not
full. Insert to power plug then wait about 10 minutes, and then pull out
from the power plug for test. If capacity is full WAC-110 (Wireless alarm
controller) will send out the sound six times.
c. May be not press set button, need to link with repeater again.
d. If the above handles are invalid, please contact with agency.
2. Problem : Unable to link with WR-110 (wireless repeater).
Solution : a. It needs to confirm the distance between WAC-110 (Wireless alarm controller)
and WR-110 (Wireless repeater). Wireless connects in non-camouflage straight
line effective range 10 meters. May pull closer between booth's distance test to
have a look first, whether to have the improvement segment condition
Specification:
Wireless Alram Contrller
Model No.
WAC-110
Electrical Specification
Transmit Frequency
2.4GHz
Modulation
GFSK
Transmit Power
0 dBm
Channel spacing
1 MHz
Channel NO.
81 Channel(2401~2481Mhz)
Range of operation
10 meters
Input Voltage (AC)
120VAC +/- 5%
Input Current (AC)
90mA Max.
Display Type
(220VAC +/- 5%)OPTION
Red LED indicator
Super light RED LED Flasher(During Alarm )
Operation Interface
Push button Switch for setting
Alarm Sound (dB)
100dB loud buzzer
Environmental Requirement
Operating temperature
-20°C to 60°C
Storage temperature
-20°C to 70°C
Humidity
90% RH Max. Non-Condensing
Mechanical Specification
Dimension (WxHxD, mm)
90x50x36
Weight
94g
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
–
–
–
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
–
Consult the dealer or an experienced radio/TV technician for help.
CAUTION:
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference and
(2) This device must accept any interference received, including interference that
may cause undesired operation.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : anitachou
Create Date                     : 2009:06:16 14:33:34+08:00
Modify Date                     : 2009:06:16 14:33:34+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Creator                         : anitachou
Title                           : Microsoft Word - 091164R_英文_使用說明書_WAC-110_無線警報器_2009_06_02.doc
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Document ID                     : uuid:f75a0395-764e-4edd-8662-ca58f6943102
Instance ID                     : uuid:666227c0-115b-41dc-8f8f-e97e1aa3bbfe
Page Count                      : 4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XBTWAC-110

Navigation menu