United Integrated Services WDT-110 WIRELESS DI TRANSDUCER User Manual

United Integrated Services CO., LTD. WIRELESS DI TRANSDUCER Users Manual

USERS MANUAL

Download: United Integrated Services WDT-110 WIRELESS DI TRANSDUCER User Manual
Mirror Download [FCC.gov]United Integrated Services WDT-110 WIRELESS DI TRANSDUCER User Manual
Document ID1133752
Application IDo75rvWuIN6T2TgFbeyrvOw==
Document DescriptionUSERS MANUAL
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize19.2kB (239951 bits)
Date Submitted2009-07-03 00:00:00
Date Available2009-07-06 00:00:00
Creation Date2009-06-16 14:19:09
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2009-06-16 14:19:09
Document TitleUsers Manual
Document CreatorPScript5.dll Version 5.2.2
Document Author: geniechang

Wireless DI Transducer User's Manual
Product Name:
Wireless DI Transducer
Model No: WDT-110
Input Power: 3V DC
Features Description:
1. To wireless transmission (opens / closes) the Dry contact signal to the repeater can be provided
with a wide range of Alarm Dry contact connected to the Sensor Products.
2. Use CR2032 type Li-ion batteries, battery power is insufficient to inform the host will
automatically operate a very low power, the battery can be used for more than one year and a
half.
3. Due to spill-resistant design for the case, so to replace batteries, the need to remove screws and
opened case.
4. Easy link, Linked with the post-instrumentation wiring ready, when install at the first time to
press the set button on the side of product binding with repeater.
5. WDT-110(Wireless DI Transducer) has a magnet base, can be adsorbed on the iron outside the
box. Foundation stop plate can be fixed on the pillar approach.
Outline Dimensions:
Feature Locator:
1.
2.
3.
4.
Foundation stop plate
State of LED window
Outlet wires
(SET) Setting button
Installation Hints:
1. Need to first WDT-110(Wireless DI Transducer) of Dry contact input signal wire, with the
industrial or household use of the various warnings dry contact sensor connected before use.
2. WDT-110(Wireless DI Transducer) leads two features excellent line and described as follows:
a. Black wire
Signal input (negative)
b. Red wire
Signal input
(positive)
3. With a CX-96R (Carbon monoxide detectors) devices as an example, the wiring diagram that
is as follows:
4. The WDT-110(Wireless DI Transducer) input signal properly then after the loop, and then
press the SET button of WDT-110, Then press the setting button of WR-110(Wireless repeater)
bottom. Wait for 30 seconds to 1 minute. If LED indicator light flash three times that means
linking success. If LED indicator light flash two times that means fail.
5. Join to link with Gateway, please reference user manual of WCC-110 (Wireless console
controller).
6. Foundation stop plate can be fixed on the pillar approach, the fixed as follows plans:
Troubleshooting:
1. Problem: When link with WR-110 (Wireless repeater), there is no display of LED
indicator light for WDT-110 (Wireless DI Transducer) to flash two or three times.
Solution : a. Need to confirm the detection of the external dry contact output of the circuit
wiring is correct.
b. May be not press set button, need to link with repeater again.
c. If the above handles are invalid, please contact with agency.
2. Problem: Unable to link with WR-110 (wireless repeater).
Solution: a. It needs to confirm the distance between WDT-110 (Wireless DI Transducer)
and WR-110 (Wireless repeater). Wireless connects in non-camouflage straight
line effective range 10 meters. May pull closer between both distance tests to
have a look first, whether to have the improvement segment condition.
Specification:
Wireless DI Transducer
Model No.
WDT-110
Electrical Specification
Transmit Frequency
2.4GHz
Modulation
GFSK
Transmit Power
0 dBm
Channel spacing
1 MHz
Channel NO.
81 Channel(2401~2481Mhz)
Range of operation
10 meters
Operating voltage
3.0V DC
Current (typical)
Working:14mA Peak
Standby:1 uA Max
Battery Type
CR2032
Battery Quantity (PCS)
Input Signal
Dry contact*1
Display Type
Red LED indicator
Operation Interface
Push Switch
Environmental Requirement
Operating temperature
-20°C to 60°C
Storage temperature
-20°C to 70°C
Humidity
90% RH Max. Non-Condensing
Mechanical Specification
Dimension (WxHxD, mm)
40x80x22
Weight (No Battery)
35g
Weight (Include Battery)
38g
Pin Assignment
Pin 1- (Red)
Dry contact Input
(Positive)
Pin 2- (White)
Dry contact Input
(Negative)
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
–
–
–
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
–
Consult the dealer or an experienced radio/TV technician for help.
CAUTION:
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference and
(2) This device must accept any interference received, including interference that may
cause undesired operation.
Canada Warning
"Industry Canada regulatory information Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must accept any interference,
including
interference that may cause undesired operation of the device.""The user is cautioned that this
device should be used only as specified within this manual to meet RF exposure
requirements. Use of this device in a manner inconsistent with this manual could lead to
excessive RF exposure conditions."

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : geniechang
Create Date                     : 2009:06:16 14:19:09+08:00
Modify Date                     : 2009:06:16 14:19:09+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Format                          : application/pdf
Title                           : <4D6963726F736F667420576F7264202D20303931313631525FAD5EA4E55FA8CFA5CEBBA1A9FAAED15F5744542D3131305FB54CBD75BCC6A6ECB054B8B9C2E0B4ABBEB95F323030395F30A14B>
Creator                         : geniechang
Document ID                     : uuid:8434b87d-de34-4ea9-98dd-94d4d8f24a7c
Instance ID                     : uuid:81f59e63-efba-4fd7-8571-9fc525a0fe6c
Page Count                      : 4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XBTWDT-110

Navigation menu