United Integrated Services WG-110 WIRELESS GATEWAY User Manual

United Integrated Services CO., LTD. WIRELESS GATEWAY Users Manual

Users Manual

Download: United Integrated Services WG-110 WIRELESS GATEWAY User Manual
Mirror Download [FCC.gov]United Integrated Services WG-110 WIRELESS GATEWAY User Manual
Document ID1153702
Application IDCLO5ZA+wrzqw5vnCExpg9g==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize254.92kB (3186475 bits)
Date Submitted2009-08-14 00:00:00
Date Available2009-08-17 00:00:00
Creation Date2009-07-31 16:42:59
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2009-07-31 16:42:59
Document TitleMicrosoft PowerPoint - UIS - User Manual-add caution-980731
Document CreatorPScript5.dll Version 5.2.2
Document Author: levenhuang

Wireless Home Security System
User Manual
Rev. 1
Confidential
Content
1. System Installation Guide
2. User Operation Guide
3. Troubleshooting Guide
4. Application Guide
Confidential
WG-110
PC/HTTP Console Configuration Guide
Confidential
System Architecture
3G
WCC-110
3G Mobile
3G
IP Camera
WiFi
Cellular Station
WiFi
Internet
PC Console
WG-110
CPE(CM or ATU-R)
Ethernet
WiFi
Zigbee
Zigbee-like
WR-110
Zigbee-like
WLC-110
WSS-110
Zigbee-like
WAT-110
3’rd-party
Electronic Door
Locker
WDT-110
WCS-110
WiFi
Zigbee
3G
WTS-110
WAC-110
WMS-110
Confidential
3’rd-party
CO detector
WPC-110
3’rd-party
Smoke Sensor
System Setup
Step 1:Power on the Gateway(WG-110) - plug adapter into the wall
power socket
WG-110
DC 12V IN
USB
WAN
3G express card
LAN
Step 2:It takes around 40 sec for Gateway to boot up and get ready, you
may check out the LEDs of Power(blue) / Normal(green) to identify
Antenna
Power
LED
Alarm
3G
WAN
Confidential
Normal
System Setup
Step 3:Set up WiFi connection between the PC and Gateway
- Power on your PC and enable WiFi(only 802.11b/g supported) network
access
- Set PC’s WiFi interface IP by using DHCP(dynamic IP)
- Search Gateway’s SSID (you may see the default SSID value on the
bottom side of Gateway while doing the first time setup) and get
connected with Gateway (PC’s WLAN IP address will be assigned by
Gateway)
WiFi signal
SSID
Confidential
System Setup
Step 4:Set up PC console
- Open the IE browser(6.0 or above) and enter the Gateway IP (you may see
the default IP address on the bottom side of Gateway while doing the first
time setup)
- Key in the login password “123” (factory default) to enter the main page
Confidential
System Setup
Step 5:Enter the main console of Gateway
Confidential
System Setup
Step 6:Click “System” to change the console login password
click here to take effect
Confidential
click here to abort
System Setup
Step 7:Click “WAN” to configure Gateway’s WAN interface
choose either one to connect to Internet
(must be following up with your local ISP
OR 3G mobile operator )
Confidential
10
System Setup
Step 8:Click “Dynamic IP” to configure Gateway’s WAN interface
choose either one as required
Confidential
11
System Setup
Step 9:Click “Static IP” to configure Gateway’s WAN interface
Confidential
12
System Setup
Step 10:Click “3GPP” to configure Gateway’s WAN(3G express card)
interface
user-definable
key in the value per your 3G provider
Confidential
13
System Setup
Step 11:Click “LAN” to configure Gateway’s LAN interface
Confidential
14
System Setup
Step 12:Click “WLAN” to configure Gateway’s WLAN interface
you may change the value as
required
you may define the key to enable
WEP data encryption as required
Confidential
15
System Setup
Step 13:Click “DDNS” to configure Gateway’s DDNS (Dynamic
DNS) information
click here to enable DDNS service
key in DDNS provider’s domain name
key in the value while applying
DDNS service (you may attain the
account information once done
the DDNS service registration)
key in the registered domain name
Confidential
16
System Setup
Step 14:Click “Reboot” to power reboot the Gateway
Confidential
17
System Setup
Step 15:Click “Reset” to reset all settings to the factory default and
power reboot the Gateway
Confidential
18
Repeater Setup
Step 16:Power on the Wireless Repeater (WR-110) and get connected
with Gateway
- Plug adapter into the wall socket to power on the Repeater
- Push the back side “set” button of Repeater for 5 sec, the indicator will
blink blue light twice and turn red light again
- Click “Join Repeater” button via the WG-110 console (see next page) to join the repeater
- Repeater’s indicator will turn blue light to sync up the access ID with WG-110
- Wait couple seconds or click the “Refresh” button to check out the result
- Repeat above steps to join the other repeaters
- The max. distance between Gateway and Repeater is 30M as suggested
WG-110
WR-110
Confidential
19
Repeater Setup
Step 17:Click “Repeater” to configure repeaters
you can join multiple Repeaters
thru here
Click here to refresh the status
click here to clean all
binding sensor information
the ID has to be matched (Repeater vs. Gateway)
to complete the binding
Confidential
the unique channel #
between Repeater and
Gateway
20
Repeater Setup
Step 18:Click the specific Repeater to configure
user-definable alias
click here to delete this Repeater connection
Confidential
21
Device Binding
LED
1. Push Repeater’s button (rear side) once
2. Push Device’s button (rear side or left side nearby logo) once
3. Verify if Device’s LED flashes three
times (red color) in sec and meanwhile,
verify if Repeater’s LED flashes once (blue color)
4. Repeat the above actions for all rest devices
WR-110
Device means for:
- Sensor
- Siren
- Controller
- Transducer
LED
Remarks:
- while binding Smoke Sensor, after pushing
the button, it will alarm three times in sec
- while binding Siren, after pushing
the button, the LED will flash three
WCS-110
times in around 15 sec
- the max. distance between Sensor
and Repeater is 10M as suggested
- Sensor will send status update to
Repeater automatically in every 10 minutes
- Gateway will put Sensor as “disconnected” status if
Confidential
Gateway didn’t get Sensor’s keep-alive signal (via Repeater)
in 30 minutes (10 min/time x 3)
rear side button
rear side button
22
Siren Setup
Step 19:Click “Siren” to configure sirens
alarm mode
silent mode
Confidential
23
Siren Setup
Step 20:Click the specific Siren to configure
Confidential
24
Automation Setup
Step 21:Click “Automation” to configure controllers
Orange means “turned-off”
Green means “turned-on”
Confidential
25
Automation Setup
Step 22:Click the specific Power Controller to configure
Confidential
26
Automation Setup
Step 23:Click the specific Lock Controller to configure
Confidential
27
Sensor Setup
Step 24:Click “Sensor” to display all binding sensor information
click here to quick
refresh all sensor
status manually
Note:
• the console will be auto
refreshed in every 20 sec
sensor name & id
sensor status or current value
sensor symbol
Confidential
28
Sensor Setup
Step 25:Click “PIR Motion Sensor” to configure
user-definable alias
click here to enable the
Partial Arm mode
click here to bind the multiple links with the
automation-related controllers
Confidential
29
Sensor Setup
Step 26:Click “Temperature Sensor” to configure
current value
click here to swap the unit
key in the max. threshold value
key in the min. threshold value
click here to enable
Siren alarm once above
threshold be reached
Confidential
30
Sensor Setup
Step 27:Click “DI Transducer” to configure
Confidential
31
Sensor Setup
Step 28:Click “Contact Sensor” to configure
Confidential
32
Sensor Setup
Step 29:Click “Smoke Sensor” to configure
Confidential
33
Sensor Setup
Step 30:Click “AI Transducer” to configure
current value
max value of attached sensor coverage
min value of attached sensor coverage
threshold value
click to enable Siren alarm
Confidential
34
Arm/Disarm System
Confidential
35
Surveillance Setup
Step 31:Set up 3rd-party wired IP camera
WG-110/DHCP server
PC
WiFi
LAN
UTP
1.
IP Camera
2.
3.
4.
5.
Confidential
Connect WG-110 and IP camera by UTP
cable OR thru external Ethernet switch
Gateway(WG-110) will release IP
address to IP camera by DHCP protocol
Open PC browser and type in IP camera’s
IP address to enter IP camera’s configuration
console
Configure IP camera’s IP address (fixed),
WiFi SSID, HTTP port# and RTSP port#
Reboot both Gateway and IP camera
36
Surveillance Setup
Step 31:Set up 3rd-party wireless IP camera
WG-110/DHCP server
PC
WiFi
LAN
UTP
1.
IP Camera
2.
3.
4.
5.
Confidential
Connect WG-110 and IP camera by UTP
cable
Gateway(WG-110) will release IP
address to IP camera by DHCP protocol
Open PC browser and type in IP camera’s
IP address to enter IP camera’s configuration
console
Configure IP camera’s IP address (fixed),
WiFi SSID, HTTP port# and RTSP port#
Disconnect the UTP connection and reboot
both Gateway and IP camera
37
Surveillance Setup
Step 32:Key in IP Camera’s Alias, IP address, and Port mapping to
add into
IP camera’s RTSP port#
IP camera’s HTTP port#
click here to add IP camera
Gateway’s RTSP port#
(must be above 1024)
Gateway’s HTTP port#
(must be above 1024)
Confidential
38
Surveillance Setup
Step 33:Reboot Gateway to take effect
click here to delete IP camera
Confidential
39
Surveillance Setup
Step 34:Choose IP camera to monitor
using HTTP to display
using RTSP to display (to be available soon)
Confidential
40
Surveillance Setup
Confidential
41
Notification Setup
Step 35:Click “Notification” to configure SMS notifications
click here to enable SMS notification
886987654321
(country code + mobile num)
886987654322
886987654323
886987654324
up to 4 mobile numbers could be entered
Confidential
42
Notification Setup
Step 36:Click “Notification” to configure Email notifications
click here to enable email notification
key in SMTP server’s IP or Domain Name
click here to enable
SMTP authentication
as required
key in username/password
sales@wss.uisco.com.tw
up to 4 email addresses could be entered
Confidential
43
System Logout
Step 37:Click “Logout” to logout the system
click
Confidential
44
WG-110
Touch Console Configuration Guide
Confidential
45
WCC-110 / Front View
Arm/Disarm status indicators/
Boot status
Touch screen
Battery status
indicators
Item
Description
Touch screen
7” 800x480 16:9 WVGA TFT color LCD displays with Touch panel
Battery status
indicators
Dual Color LED(Green, Red) to show the battery status of
1. In charging ( AC power on) - Red LED blinking ,
2.Battery discharge- Yellow continue ,
3.low battery – Red LED continue on
4. Normal(AC power on, battery high) – Green LED continue on
Arm/Disarm status
indicators/
Boot status
Dual Color(Blue,Red)LED to show the status of the Arm/Disarm Status
1.Full(Partial) Arm: Red LED blinking ;
2.Disarm: Blue continue on
3.Booting --Blue LED blinking
Confidential
46
WCC-110 / Back View
Item
Description
Connects to an Ethernet 10/100 based network.
Ethernet
(RJ-45)
port
External
display
(VGA) port
DC-in jack
Connects to an AC adapter.
Connects to a display device (e.g. external monitor,
LCD projector.
Confidential
47
WCC-110 / Side View
Item
Description
Power
button
Turn on/off Console Controller
USB
2.0/1.1 port
Connects to USB devices (e.g. USB camera, USB
keyboard).
Speaker
jack
Connects to audio devices (e.g. external speakers).
Confidential
48
WCC-110 Setup
Power ON :
1.
2.
Plug in the power adapter
Push the power button to power on the device
Confidential
49
WCC-110 Setup
1. Key in password
The default value is
“123”
2. Click here
to login
Confidential
50
WCC-110 Setup
Click here to logout
Touch here to enter
into the setup main
console
Touch here to enter into the
Gateway setup screen
To be available
Confidential
51
WCC-110 Setup
Same as PC console
Confidential
52
WCC-110 Setup
Touch here to enter into the
setup main console
Touch here to enter into the
WCC-110 setup screen
Confidential
53
WCC-110 Setup
Touch here to enter into
the password setup screen
Confidential
54
WCC-110 Setup
Confidential
55
WCC-110 Setup
Touch here to enter into
the network setup screen
Confidential
56
WCC-110 Setup
1. Key in Gateway’s LAN IP,
SSID(if know) & WiFi network
key(if have)
3. Click here to activate
all settings
Confidential
2. Click here to
searching for WiFi
SSID(if don’t know),
move to the next
page to continue
57
WCC-110 Setup
1. Choose the right SSID
that you’re going to get
connected with Gateway
2. Key-in the WiFi key if have
3. Click here to get connected
Confidential
58
WCC-110 Setup
Touch here to enter into the
setup main console
Touch here to enter into the
IP Camera setup screen
Confidential
59
WCC-110 Setup
Key-in IP Camera’s IP
address(if know)
DHCP IP address
release table
Click here to
renew the table
Confidential
60
Content
1. System Installation Guide
2. User Operation Guide
3. Troubleshooting Guide
4. Application Guide
Confidential
61
PC/HTTP Console
Confidential
62
PC/HTTP Console
Show up the real-time
mode once changed
Confidential
63
WCC-110 Console
Touch here to enter
into the Arm/Disarm
main console
Choose either mode you prefer
Confidential
64
WCC-110 Console
Touch here to enter into the
automation-related main
console
Confidential
65
WCC-110 Console
2. Choose the IP
Cam you want to
watch
1. Touch here to enter
into the Monitoring
main console
Confidential
66
Content
1. System Installation Guide
2. User Operation Guide
3. Troubleshooting Guide
4. Application Guide
Confidential
67
Troubleshooting Tips
Partial Arm mode be disabled
Confidential
68
Troubleshooting Tips
sensor(vs. magnet) in open mode
Confidential
69
Troubleshooting Tips
you can’t enable Partial
or Full Arm mode while
WCS is in open mode
Confidential
70
Troubleshooting Tips
disconnected, has to
re-do the binding with
Repeater (or, you may
have to delete it first)
Confidential
71
Content
1. System Installation Guide
2. User Operation Guide
3. Troubleshooting Guide
4. Application Guide
Confidential
72
AI/DI Transducer Applications
4-20mA CO Detector
AI Transducer
NC/NO CO Detector
NC Fire Alarm
Temperature Sensor
DI Transducer
DI Transducer
4-20mA GAS Detector
NC/NO SMOKE
Detector
AI Transducer
NC/NO GAS Detector
AI Transducer
DI Transducer
Confidential
DI Transducer
73
AI/DI Transducer Applications
NC/NO_relay-type
disaster sensor
DI Input
4-20mA AI Input
AI/DI Transducer
Linear-type (data retrievable)
disaster sensor
Confidential
74
AI/DI Transducer Applications
CO sensor
DC12v
Adapter
DC+
DC-
,
Confidential
DI Transducer
75
AI/DI Transducer Applications
Smoke Detector
DC12V
Adapter
- DI Transducer
Installing location
Bed Bed Bed
kitchen room room room
Bath
room
Living room
Ceiling mount
Top of the
ladder
from Wall
Confidential
Gallery
76
AI/DI Transducer Applications
4-20mA
AI Transducer
Symbol description:
DC POWER SUPPLY:24VDC ~30VDC。
AI Transducer:To transfer 4 ~ 20 mA current to wireless digital datat。
B:Black wire R:Red wire G:Green wire
F:Fuse GTF200-FL recommend adopt 0.2A or 0.1A Fuse
Confidential
77
AI/DI Transducer Applications
4-20mA current
AI Transducer
To transform the Temperature Sensor signal into wireless control signal by
using AI Transducer(4-20mA).
Confidential
78
AI/DI Transducer Applications
manual button switch
Electric Lock
WLC-110
To transform a conventional Electric Lock signal into wireless
control signal by Lock Controller
Confidential
79
Product Declaration
CAUTION !!
Risk of explosion if battery is replaced by an incorrect type
Dispose of used batteries according to the instructions
Confidential
80
3G WWAN Cards Purchase Inf.
•
•
•
•
•
3G express card is an option for customer to purchase from the third-party (non-UIS
product), it’s highly recommended to choose from UIS’s AVL suppliers.
3G WWAN cards support list of WG-110
Brand
Model Number
FCCID Number
Option NV
GE0441
NCMOGE0441
Sierra Wireless Inc.
AirCard 880E
N7NAC880E
The customer should purchase the 3G WWAN cards which shall be FCC approved.
3G WWAN cards must not exceed a maximum ERP of 1.5W for part 22H.
3G WWAN cards must not exceed a maximum EIRP of 2W for part 24E.
The End
Confidential
82

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : levenhuang
Create Date                     : 2009:07:31 16:42:59+08:00
Modify Date                     : 2009:07:31 16:42:59+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Format                          : application/pdf
Title                           : Microsoft PowerPoint - UIS - User Manual-add caution-980731
Creator                         : levenhuang
Document ID                     : uuid:398a64ee-ea93-4f96-ab93-06a67f97b085
Instance ID                     : uuid:f42576e6-3a9c-4ce3-beb9-4ebc4d35de15
Page Count                      : 82
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XBTWG-110

Navigation menu