Utica Boilers Bc Series Ii Brochure
2015-05-15
: Utica-Boilers Utica-Boilers-Bc-Series-Ii-Brochure-719571 utica-boilers-bc-series-ii-brochure-719571 utica-boilers pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
BC Series II There Are Some Things You Can Always Depend On... BC Series II Up to 85% AFUE Oil Fired Hot Water Boiler - Available in 3 sizes from 133 MBH to 161 MBH. - Dependable Cast Iron Exchanger with Cast Iron Push Nipples. The Sections and Push Nipples expand at the same rate when heated. By using similar materials instead of less expensive gaskets the boiler maintains a water tight seal over time. - Honeywell High Limit/Electronic Ignition Control. • Digital temperature display and diagnostics. • Less Coil: Control monitors water temperature and delays the burner starting until any residual heat has been transferred. Thermal purge logic measures rate of temperature change inside the boiler and delays burner firing accordingly. This maximizes efficiency by turning on the burner only when needed. • With Coil: Low Limit Control satisfies Domestic Hot Water call. When low limit calls the control seeks maximum temperature to satisfy domestic hot water call bypassing thermal purge logic. - Atmospheric Chimney Vent Boiler. - Optional Tankless Heater Coil. - Textured paint Jacket. - Limited Lifetime Warranty (Residential Applications). - Made in the U.S.A. UTB507 BC-SeriesII_SellSheet213.indd 1 2/18/13 12:47 PM Utica BC Series II Residential Oil Fired Water Boiler Dimensional Diagram AHRI Oil Burner Input (1) Model (1) G.P.H. BC3095 Mbh (4) 0.95 Net AHRI Min. Natural Draft Heating (2) (4) Chimney Size Capacity Ratings Mbh (4) Water Mbh Round Square 133 114 99 6” AFUE % 84.0% 8”x8”x15’ BC4100 1.00 140 121 105 6” 8”x8”x15’ 85.0% BC4115 1.15 161 137 119 6” 8”x8”x15’ 84.0% (1) AHRI burner capacity is based on an oil heating value of 140,000 Btu/gal and with 13% CO2. (2) Net AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15. BC Series II Front View (3) Consult manufacturer before selecting boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping. (4) For forced hot water heating systems where boiler and all piping are within the area to be heated, select boiler on basis of its Heating Capacity. General Information (See Installation, Operation and Maintenance Manual for complete instructions) Combustible Materials (Required) Clearances Required distances measured from boiler. Top 24” (610 mm) Left Side (Control Side) 6” (152 mm) Right Side 24” (610 mm) Front 24” (610 mm) Back 6” (152 mm) Flue Connector 9” (229 mm) Connections (All Models) Return/Supply Tappings 1-1/4” NPT, Oil Line 3/8” O.D. copper tubing for runs of 50 feet or less, and ½” O.D. for longer runs. Electrical 120 Volts AC, 60 hertz, 1 phase, Less than 12 amps (15 amp circuit recommended) Tankless Heater Capacities BC Series II Side View Dimensions/ Weights Model Input Rate G.P.H. BC3095 0.95 BC4100 1.00 BC4115 1.15 Tankless Heater Number Tankless Heater Capacity Intermittent Draw G.P.M. Boiler Water Content (Gallons) 3.25 6.7 3.25 8.2 4.00 8.2 L-24 Model A (Length of Flush Jacket) B (Front of Jacket to Center Line of Flue Outlet) C (Flue Outlet Diameter) D (Tankless Coil to Back of Jacket) Weight BC3095 19” 9-3/4” 6” 8-7/8” 345 lbs. BC4100 23” 11-3/4” 6” 12-3/4” 404 lbs. BC4115 23” 11-3/4” 6” 12-3/4” 404 lbs. Standard Equipment Boiler Controls: High Limit, Circulator Control and Primary Control. Heat Exchanger: Cast Iron Heat Exchanger with Cast Iron Push Nipples. Combustion: Beckett Oil Burner, Combustion Chamber with Target Wall/Liner. Electrical: Wiring Harness, Burner Electrical Disconnect. Safety: 30 PSI A.S.M.E. Safety Relief Valve. Other: Crated Cast Iron Boiler with Insulated Flush Jacket; Circulator - 1-1/4”, Temperature Pressure Gauge, Boiler Drain Valve, 1-1/4” Supply and Return Tapping. For Tankless Heater Units: Tankless Hot Water Coil and Low Limit. Options Taco, Grundfos or Less Pump; Tankless Coil. Certifications Maximum Allowable Working Pressure 30 psi. All ratings and specifications subject to change. Contractor Assistance: 800.325.5479 UTB507 BC-SeriesII_SellSheet213.indd 2 PN 240009784 Rev. 2/13 P.O. Box 4729 Utica, New York 13504 tel: 315.797.1310 • fax: 315.797.3762 www.uticaboilers.com 2/18/13 12:47 PM
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2013:02:18 12:47:34-05:00 Creator : Adobe InDesign CS6 (Macintosh) Modify Date : 2013:02:19 12:23:00-05:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Instance ID : uuid:6610ecb7-60c5-7249-b8e5-5f1d9b4a2829 Original Document ID : adobe:docid:indd:512815ae-3bc8-11e1-8bb3-984a65b969d7 Document ID : xmp.id:3D231474072068118083A173353236DB Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:3C231474072068118083A173353236DB Derived From Document ID : xmp.did:C4BBF7B50720681180839B93D6A24223 Derived From Original Document ID: adobe:docid:indd:512815ae-3bc8-11e1-8bb3-984a65b969d7 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2013:02:18 12:47:34-05:00 Metadata Date : 2013:02:19 12:23-05:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2EXIF Metadata provided by EXIF.tools