Utica Boilers Cub Series Submittal

2015-05-20

: Utica-Boilers Utica-Boilers-Cub-Series-Submittal-719544 utica-boilers-cub-series-submittal-719544 utica-boilers pdf

Open the PDF directly: View PDF PDF.
Page Count: 4

DownloadUtica-Boilers Utica-Boilers-Cub-Series-Submittal-  Utica-boilers-cub-series-submittal
Open PDF In BrowserView PDF
Utica Boilers CHB-100/130 - Submittal
Engineer:____________________________________________
Project Name:________________________________________
Project Location:______________________________________
Contractor:___________________________________________
APPLICATION:
Modulating Gas fired water heating boiler for indoor installation. Approved for closet or alcove installations.
For use with natural or liquefied petroleum (LP/Propane) fuel gases, LP conversion kits available as option.
Wall mounted – optional floor stand available. All boilers are factory assembled with controls and wiring
and test fired to ensure dependable performance. Boiler shall be certified for Category I and Category III
applications.
CERTIFICATION AND APPROVALS:
Copper tube heat exchanger is manufactured and tested in accordance with American Society of Mechanical
Engineers (ASME) and certified by Canadian Standards Association (CSA). Copper tube heat exchanger is
tested for maximum allowable working pressure of 43.5 psig in accordance with ASME boiler and pressure
vessel code, section IV, rules for construction of heating boilers. A 30 psig safety relief valve is shipped
standard.
BOILERS INCLUDE:
•	Wall mount bracket
•	Boiler has separate dedicated supply & return water connections to supply hot water directly to an Indirect
tank.
•	Boiler is equipped with an automatic 3 way diverting valve to allow Domestic Hot Water Priority operation.
•	Boiler includes an internal pressure activated bypass loop to eliminate the need for primary secondary
piping and includes an internal factory installed and wired circulator pump.
•	Digital Boiler Control:
XX Control system is PCB integral controller with LCD digital display that includes graphical interface.
XX Control senses supply water temperature and adjusts the boiler firing rate to deliver amount of heat
needed.
XX Control can sense and display supply water temperature and indicate by icon when boiler is in central
heating or domestic water mode.
XX Control can accept a wired Outdoor Air sensor and has field selectable reset curves
XX Control continuously monitors boiler during operation and standby modes. Control receives input data
from dual temperature sensor, air pressure transducer, and outdoor air temperature sensors (when
used) to adjust modulation rate accordingly.
XX Control can power and accept input from field supplied LWCO device.

2201 Dwyer Ave.

Utica, NY 13501

www.UticaBoilers.com

P/N 240010784 REV C, [02/2015]

•	Boiler Combustion System:
XXThe Gas valve is a modulating valve capable of firing from 100% input firing rate to 33% input firing rate.
XXInduced draft blower is variable speed. PCB uses air pressure transducer to vary blower speed.
XXBurners and manifold shall be constructed of stainless steel.
XXIgnition system shall be direct spark single rod flame sensing
•	Primary Heat Exchanger:
XXBoiler’s primary heat exchanger is constructed of copper tube with copper fins, stainless steel support 	
plates and is covered with a high temperature protective coating.
•	Electrical:
XX120 volts AC, 60 Hertz, 1-phase; less than 12 amps.
XXFactory wired 6-foot appliance cord with male plug end.
XXLow voltage terminal strip for Thermostat, and optional Outdoor Air Sensor, 	
DHW Indirect tank sensor and LWCO

	

•	Optional Equipment:
XXFloor mounting stand
XXOutdoor Air Sensor
XXDirect Vent Termination Kit
XXLP Conversion kit
XXDHW Sensor kit for Indirect tank	

SEA LEVEL RATINGS
NATURAL AND PROPANE GASES

Size

Boiler Input Rate
(MBH)(1)
Maximum

Minimum

Heating
Capacity
(MBH)(1)(2)

100
130

31.5
43.5

85
110

CHB-100
CHB-130

Net AHRI
Rating, Water
(MBH)(1)(3)

AFUE(2)

73.0
96.0

85.0
85.0

1000 Btu/hr (British Thermal Units Per Hour)
Heating Capacity and AFUE (Annual Fuel Utilization Efficiency) are based on DOE (Department of Energy) test procedures.
(3)
Net AHRI Ratings based on piping and pickup allowance of 1.15. Contact Technical Support before selecting boiler for
installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.
(1)
(2)

•	Constructed and hydrostatically tested for maximum allowable working pressure of 43.5 psig
(pounds per square inch gauge) (.30MPa) in accordance with ASME Boiler and Pressure Vessel
Code, Section IV, Rules for Construction of Heating Boilers.
•	 USA - Input rates are derated 4% for each 1000 ft (300m) above sea level,beyond 2000 ft. (600m).
•	 CANADA - Ratings above used for elevations up to 200 ft (600m) above sea level.
- For elevations between 2000 ft (600m) and 4500 ft (1350m), derate 10% using high altitude kit.
- Contact Provincial authority having jurisdiction for installations above 4500 feet (1350m) above
sea level.

2201 Dwyer Ave.

Utica, NY 13501

www.UticaBoilers.com

P/N 240010784 REV C, [02/2015]

Overall Dimensions

7
= Gas Inlet - 3/4” FPT
10 = System Delivery - 1” MPT
11 = System Return - 1” MPT
*209 = Hot Water Tank Delivery - 3/4” Capped
*210 = Hot Water Tank Return - 3/4” Capped
* BSPT To NPT Adapters Included

2201 Dwyer Ave.

Utica, NY 13501

www.UticaBoilers.com

P/N 240010784 REV C, [02/2015]

Boiler Clearances
Combustible
Materials (1)

Service(1)(2)

16” (41cm)

12" (30cm)

Left Side (B)

0" (0 cm)

1” (3 cm)

Right Side (C)

0" (0 cm)

1” (3 cm)

Dimension
Top (A)

Front (D)

0" (0 cm)

1" 3 cm)

Back (E)

0" (0 cm)

0” (0 cm)

Bottom (F)

0" (0 cm)

4" (12 cm)

Combustion Air/
piping

0” (0 cm)

3/8" (1 cm)

6” (15 cm)

6” (15 cm)

Vent piping
(1)
(2)



Required distances measured from boiler jacket.
Service, proper operation clearance recommendation.



Combustion Air and Vent Pipe Fittings Category I
(Chimney Vent)
Item

Vent Pipe &
Fittings

Combustion Air

Material

Standards

Type B Vent

UL 441, ULC
S605

Masonry Chimney
- must conform
to proper sizing
and materials

National Fuel
Gas Code, ANSI
Z223.1/NFPA 54

Stainelss Steel,
PVC, CPVC, PP

ANSI/ASTM
D2564, ANSI/
ASTM F493, UL
1738/ULC636-08



Horizontal
Venting requires
eld supplied
appliance adapter
the boiler ueappliance
outlet.
Horizontal
Venting
requires
field for
supplied
Boiler
is provided with
ventboiler
connection.
A 3” xoutlet.
4” increaser must be eld supplied
adapter
fora 3”
the
flue
for chimney
ventisapplications.
This with
does notainfer
the connection
to the chimney
Boiler
provided
3”thatvent
connection,
3”
will always be 4”.
x refer
4” increaser
sourced for
chimney
Please
to IOM, National must
Fuel Gas be
Code,field
ANSI Z223.1/NFPA54,
or applicable
proapplication.
This
not
mean
that
theconnections.
connection
visions
of the local building
codesdoes
for details
concerning
proper
chimney

to the chimney will always be 4”.

Combustion Air and Vent Pipe Fittings Category III (Horizontal Vent & Direct Vent)
Type

Item

Diameter

Min
Length

Max
Length

Materital

Standards

Vent

3”

5 ft

65 ft

AL294C
Stainless Steel,
Aluminum

UL1738,
ULC S636

Air Intake

3”

5 ft

65 ft

Stainless Steel,
PVC, CPVC, PP,
Aluminum

ANSI/ASTM D2564,
ANSI/ASTM F493,
UL1738/ULC636-08

Vent

3”

5 ft

65 ft

AL294C
Stainless Steel
Aluminum

UL1738,
ULC S636

Direct
Vent

Category
III

Equivalent Length of Venting Components:
•	 	5 ft. equivalent for a 3” 90° elbow
•		2½ ft. equivalent for 3” 45° elbow
2201 Dwyer Ave.

Utica, NY 13501

www.UticaBoilers.com

P/N 240010784 REV C, [02/2015]



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c014 79.156797, 2014/08/20-09:53:02
Create Date                     : 2015:02:24 11:55:32-05:00
Metadata Date                   : 2015:02:24 11:55:37-05:00
Modify Date                     : 2015:02:24 11:55:37-05:00
Creator Tool                    : Adobe InDesign CC 2014 (Windows)
Instance ID                     : uuid:d978828b-2902-4720-919d-34ce507e1f02
Original Document ID            : xmp.did:ED26EFB1778EE311BC0DEE3BF8290C38
Document ID                     : xmp.id:dc6ffcd5-2305-1844-b963-fa8332590f83
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:9721cb48-0fdf-2a4b-9ef9-027631469ef7
Derived From Document ID        : xmp.did:278708f0-b2d1-ab4b-8ca9-2107975bb8df
Derived From Original Document ID: xmp.did:ED26EFB1778EE311BC0DEE3BF8290C38
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2014 (Windows)
History Changed                 : /
History When                    : 2015:02:24 11:55:32-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 11.0
Trapped                         : False
Page Count                      : 4
Creator                         : Adobe InDesign CC 2014 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu