Utica Boilers Cub Series Submittal
2015-05-20
: Utica-Boilers Utica-Boilers-Cub-Series-Submittal-719544 utica-boilers-cub-series-submittal-719544 utica-boilers pdf
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
Utica Boilers CHB-100/130 - Submittal Engineer:____________________________________________ Project Name:________________________________________ Project Location:______________________________________ Contractor:___________________________________________ APPLICATION: Modulating Gas fired water heating boiler for indoor installation. Approved for closet or alcove installations. For use with natural or liquefied petroleum (LP/Propane) fuel gases, LP conversion kits available as option. Wall mounted – optional floor stand available. All boilers are factory assembled with controls and wiring and test fired to ensure dependable performance. Boiler shall be certified for Category I and Category III applications. CERTIFICATION AND APPROVALS: Copper tube heat exchanger is manufactured and tested in accordance with American Society of Mechanical Engineers (ASME) and certified by Canadian Standards Association (CSA). Copper tube heat exchanger is tested for maximum allowable working pressure of 43.5 psig in accordance with ASME boiler and pressure vessel code, section IV, rules for construction of heating boilers. A 30 psig safety relief valve is shipped standard. BOILERS INCLUDE: • Wall mount bracket • Boiler has separate dedicated supply & return water connections to supply hot water directly to an Indirect tank. • Boiler is equipped with an automatic 3 way diverting valve to allow Domestic Hot Water Priority operation. • Boiler includes an internal pressure activated bypass loop to eliminate the need for primary secondary piping and includes an internal factory installed and wired circulator pump. • Digital Boiler Control: XX Control system is PCB integral controller with LCD digital display that includes graphical interface. XX Control senses supply water temperature and adjusts the boiler firing rate to deliver amount of heat needed. XX Control can sense and display supply water temperature and indicate by icon when boiler is in central heating or domestic water mode. XX Control can accept a wired Outdoor Air sensor and has field selectable reset curves XX Control continuously monitors boiler during operation and standby modes. Control receives input data from dual temperature sensor, air pressure transducer, and outdoor air temperature sensors (when used) to adjust modulation rate accordingly. XX Control can power and accept input from field supplied LWCO device. 2201 Dwyer Ave. Utica, NY 13501 www.UticaBoilers.com P/N 240010784 REV C, [02/2015] • Boiler Combustion System: XXThe Gas valve is a modulating valve capable of firing from 100% input firing rate to 33% input firing rate. XXInduced draft blower is variable speed. PCB uses air pressure transducer to vary blower speed. XXBurners and manifold shall be constructed of stainless steel. XXIgnition system shall be direct spark single rod flame sensing • Primary Heat Exchanger: XXBoiler’s primary heat exchanger is constructed of copper tube with copper fins, stainless steel support plates and is covered with a high temperature protective coating. • Electrical: XX120 volts AC, 60 Hertz, 1-phase; less than 12 amps. XXFactory wired 6-foot appliance cord with male plug end. XXLow voltage terminal strip for Thermostat, and optional Outdoor Air Sensor, DHW Indirect tank sensor and LWCO • Optional Equipment: XXFloor mounting stand XXOutdoor Air Sensor XXDirect Vent Termination Kit XXLP Conversion kit XXDHW Sensor kit for Indirect tank SEA LEVEL RATINGS NATURAL AND PROPANE GASES Size Boiler Input Rate (MBH)(1) Maximum Minimum Heating Capacity (MBH)(1)(2) 100 130 31.5 43.5 85 110 CHB-100 CHB-130 Net AHRI Rating, Water (MBH)(1)(3) AFUE(2) 73.0 96.0 85.0 85.0 1000 Btu/hr (British Thermal Units Per Hour) Heating Capacity and AFUE (Annual Fuel Utilization Efficiency) are based on DOE (Department of Energy) test procedures. (3) Net AHRI Ratings based on piping and pickup allowance of 1.15. Contact Technical Support before selecting boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc. (1) (2) • Constructed and hydrostatically tested for maximum allowable working pressure of 43.5 psig (pounds per square inch gauge) (.30MPa) in accordance with ASME Boiler and Pressure Vessel Code, Section IV, Rules for Construction of Heating Boilers. • USA - Input rates are derated 4% for each 1000 ft (300m) above sea level,beyond 2000 ft. (600m). • CANADA - Ratings above used for elevations up to 200 ft (600m) above sea level. - For elevations between 2000 ft (600m) and 4500 ft (1350m), derate 10% using high altitude kit. - Contact Provincial authority having jurisdiction for installations above 4500 feet (1350m) above sea level. 2201 Dwyer Ave. Utica, NY 13501 www.UticaBoilers.com P/N 240010784 REV C, [02/2015] Overall Dimensions 7 = Gas Inlet - 3/4” FPT 10 = System Delivery - 1” MPT 11 = System Return - 1” MPT *209 = Hot Water Tank Delivery - 3/4” Capped *210 = Hot Water Tank Return - 3/4” Capped * BSPT To NPT Adapters Included 2201 Dwyer Ave. Utica, NY 13501 www.UticaBoilers.com P/N 240010784 REV C, [02/2015] Boiler Clearances Combustible Materials (1) Service(1)(2) 16” (41cm) 12" (30cm) Left Side (B) 0" (0 cm) 1” (3 cm) Right Side (C) 0" (0 cm) 1” (3 cm) Dimension Top (A) Front (D) 0" (0 cm) 1" 3 cm) Back (E) 0" (0 cm) 0” (0 cm) Bottom (F) 0" (0 cm) 4" (12 cm) Combustion Air/ piping 0” (0 cm) 3/8" (1 cm) 6” (15 cm) 6” (15 cm) Vent piping (1) (2) Required distances measured from boiler jacket. Service, proper operation clearance recommendation. Combustion Air and Vent Pipe Fittings Category I (Chimney Vent) Item Vent Pipe & Fittings Combustion Air Material Standards Type B Vent UL 441, ULC S605 Masonry Chimney - must conform to proper sizing and materials National Fuel Gas Code, ANSI Z223.1/NFPA 54 Stainelss Steel, PVC, CPVC, PP ANSI/ASTM D2564, ANSI/ ASTM F493, UL 1738/ULC636-08 Horizontal Venting requires eld supplied appliance adapter the boiler ueappliance outlet. Horizontal Venting requires field for supplied Boiler is provided with ventboiler connection. A 3” xoutlet. 4” increaser must be eld supplied adapter fora 3” the flue for chimney ventisapplications. This with does notainfer the connection to the chimney Boiler provided 3”thatvent connection, 3” will always be 4”. x refer 4” increaser sourced for chimney Please to IOM, National must Fuel Gas be Code,field ANSI Z223.1/NFPA54, or applicable proapplication. This not mean that theconnections. connection visions of the local building codesdoes for details concerning proper chimney to the chimney will always be 4”. Combustion Air and Vent Pipe Fittings Category III (Horizontal Vent & Direct Vent) Type Item Diameter Min Length Max Length Materital Standards Vent 3” 5 ft 65 ft AL294C Stainless Steel, Aluminum UL1738, ULC S636 Air Intake 3” 5 ft 65 ft Stainless Steel, PVC, CPVC, PP, Aluminum ANSI/ASTM D2564, ANSI/ASTM F493, UL1738/ULC636-08 Vent 3” 5 ft 65 ft AL294C Stainless Steel Aluminum UL1738, ULC S636 Direct Vent Category III Equivalent Length of Venting Components: • 5 ft. equivalent for a 3” 90° elbow • 2½ ft. equivalent for 3” 45° elbow 2201 Dwyer Ave. Utica, NY 13501 www.UticaBoilers.com P/N 240010784 REV C, [02/2015]
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c014 79.156797, 2014/08/20-09:53:02 Create Date : 2015:02:24 11:55:32-05:00 Metadata Date : 2015:02:24 11:55:37-05:00 Modify Date : 2015:02:24 11:55:37-05:00 Creator Tool : Adobe InDesign CC 2014 (Windows) Instance ID : uuid:d978828b-2902-4720-919d-34ce507e1f02 Original Document ID : xmp.did:ED26EFB1778EE311BC0DEE3BF8290C38 Document ID : xmp.id:dc6ffcd5-2305-1844-b963-fa8332590f83 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:9721cb48-0fdf-2a4b-9ef9-027631469ef7 Derived From Document ID : xmp.did:278708f0-b2d1-ab4b-8ca9-2107975bb8df Derived From Original Document ID: xmp.did:ED26EFB1778EE311BC0DEE3BF8290C38 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2014 (Windows) History Changed : / History When : 2015:02:24 11:55:32-05:00 Format : application/pdf Producer : Adobe PDF Library 11.0 Trapped : False Page Count : 4 Creator : Adobe InDesign CC 2014 (Windows)EXIF Metadata provided by EXIF.tools