JE Steam
There Are Some Things You Can Always Depend On...

JE Steam

Commercial Gas Fired Steam Boiler
Electronic Ignition Base
Standard Equipment:
	

	
	
	
	
	
	
	

Base
Fire Door
• Burner Orifice
• Manifold
• Main and Pilot Burner
• Electronic Pilot Gas Valve
• Intermittent Pilot Module
• Complete Jacket Assembly
•
•

Steam Trim
Package:
	

	
	
	
	
	

Low Water Cut-Off
Glass Gauge Set
• Safety Valve
• Steam Gauge
• Pressure Limit
• Drain Valve
•
•

JE Series Boiler Bases are pre-assembled at the factory with burner manifold,
burner orifices, gas valves and electronic ignition installed, ready for field
installation of the pre-tested sections and appropriate packages.

Plug ‘N Play Harness and Junction Box
Individual base and junction box controls are designed for easy installation with
Plug ‘n Play harnesses. The entire boiler links together in a “snap”. A color-coded
factory supplied harness eliminates wiring errors.

CSD1 Option
JE boilers are available with a CSD1 option to comply with CSD1 standards
where required by building code. The CSD1 option provides the increased
number of controls and safety devices required to meet CSD1 standards.

Utica JE Commercial Gas-Fired Steam Boiler
Chimney
Size (4)

Steam
(PPF) (2)

Steam
(Sq. Ft.) (3)

Steam
(Mbh) (2)

300
(8")

400
(10")

500 (12")

I.D. x Ht.

Vent
Connector
Size to
Chimney (4)

233

1.333

729

175

1

0

0

8" x 20'

8

77.0

400

310

1.333

971

233

0

1

0

10" x 20'

10

77.0

JE500S

500

388

1.333

1213

291

0

0

1

12" x 20'

12

77.0

JE600S

600

465

1.333

1454

349

2

0

0

12" x 20'

12

77.0

JE700S

700

543

1.333

1696

407

1

1

0

12" x 20'

12

77.0

JE800S

800

620

1.333

1938

465

0

2

0

14" x 20'

14

77.0

JE900S

900

698

1.333

2183

524

0

1

1

14" x 20'

14

77.0

JE1000S

1000

775

1.333

2421

581

0

0

2

14" x 20'

14

77.0

JE1100S

1100

853

1.333

2667

640

1

2

0

16" x 20'

16

77.0

JE1200S

1200

930

1.333

2908

698

0

3

0

16" x 20'

16

77.0

JE1300S

1300

1008

1.333

3150

756

1

0

2

16" x 20'

16

77.0

JE1400S

1400

1085

1.333

3392

814

0

1

2

18" x 20'

18

77.0

JE1500S

1500

1163

1.333

3633

872

0

0

3

18" x 20'

18

77.0

Model

Input
(Mbh) (1)

Gross
Output
(Mbh)

JE300S

300

JE400S

Net AHRI Ratings

Right & Left End Tappings Data

D
A

F
B
G
B

Opening

Size

Steam

A

4”

Supply and Return

B

1/2”

Primary LWCO
and Gauge
Glass set

C

3/4”

Drain, Left End

C

3/4”

Drain, Right End

D

1/2”

Plugged

A
E
C

E

1”

Accessories

*F

1”

Safety Valve

G

3/4”

Plugged or
Electronic
(Probe Type) LWCO

*If opening F is to be used for something other than the Safety Valve or Pressure
Relief Valve, or the Safety/Relief Valve is larger than 1”, the Safety/Relief Valve
must be installed in the Header Piping as near to the boiler as possible.

Contractor
Assistance: 800.325.5479

Base Size & Flue Outlet

Thermal
Efficiency

1. Ratings are at sea level to 2,000 feet. For altitudes above 2,000 feet, reduce all ratings 4% for each
1,000 feet above sea level.
2. Net steam ratings based on piping and pickup allowance of 1.333 (300-1500). Contact Technical Support
before selecting boiler for installations having unusual piping and pick-up factors, such as intermittent
system operations, extensive piping systems, etc.
3. Ratings in square feet are computed at 240 Btuh/square foot for steam boilers.
4. Chimney sizes shown are one option based on a typical venting system as shown in Figure 6 of the
Installation Manual, and sized according to the National Fuel Gas Code, assuming Type B double wall
vent and vent connectors, other venting system designs are acceptable as shown on Flue Connection
And Venting section of the installation manual. For further chimney design and sizing information,
consult the National Fuel Gas Code, ANSI Z223.1/NFPA 54-latest revision, or ASHRAE HVAC Systems
and Equipment Handbook, Chimney, Gas Vent, and Fireplace Systems, or the Standard for Chimneys,
Fireplaces, Vents, and Solid Fuel Burning Appliances. NFPA 211. Follow standard
engineering practice.

Certifications

All ratings and specifications subject to change.

P.O. Box 4729
Utica, New York 13504
tel: 315.797.1310 • fax: 315.797.3762
www.uticaboilers.com

PN 240009442 Rev. 6/14



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Instance ID                     : uuid:565f2714-b559-d74e-b37c-b28fe9bdbb62
Original Document ID            : adobe:docid:indd:64c10fb5-9344-11df-9e53-ba4cb7a41fa7
Document ID                     : xmp.id:AAF566582520681197A5D9849BD57CC3
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:A9F566582520681197A5D9849BD57CC3
Derived From Document ID        : xmp.did:B8022A2C1F2068118A6DA6EFC45FA990
Derived From Original Document ID: adobe:docid:indd:64c10fb5-9344-11df-9e53-ba4cb7a41fa7
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh)
History Changed                 : /
History When                    : 2014:05:30 11:45:47-04:00
Create Date                     : 2014:05:30 11:45:47-04:00
Modify Date                     : 2014:05:30 11:45:59-04:00
Metadata Date                   : 2014:05:30 11:45:59-04:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS6 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu