Utica Boilers Je Brochure
2015-05-20
: Utica-Boilers Utica-Boilers-Je-Brochure-719527 utica-boilers-je-brochure-719527 utica-boilers pdf
Open the PDF directly: View PDF
.
Page Count: 2
| Download | |
| Open PDF In Browser | View PDF |
JE Steam There Are Some Things You Can Always Depend On... JE Steam Commercial Gas Fired Steam Boiler Electronic Ignition Base Standard Equipment: Base Fire Door • Burner Orifice • Manifold • Main and Pilot Burner • Electronic Pilot Gas Valve • Intermittent Pilot Module • Complete Jacket Assembly • • Steam Trim Package: Low Water Cut-Off Glass Gauge Set • Safety Valve • Steam Gauge • Pressure Limit • Drain Valve • • JE Series Boiler Bases are pre-assembled at the factory with burner manifold, burner orifices, gas valves and electronic ignition installed, ready for field installation of the pre-tested sections and appropriate packages. Plug ‘N Play Harness and Junction Box Individual base and junction box controls are designed for easy installation with Plug ‘n Play harnesses. The entire boiler links together in a “snap”. A color-coded factory supplied harness eliminates wiring errors. CSD1 Option JE boilers are available with a CSD1 option to comply with CSD1 standards where required by building code. The CSD1 option provides the increased number of controls and safety devices required to meet CSD1 standards. Utica JE Commercial Gas-Fired Steam Boiler Chimney Size (4) Steam (PPF) (2) Steam (Sq. Ft.) (3) Steam (Mbh) (2) 300 (8") 400 (10") 500 (12") I.D. x Ht. Vent Connector Size to Chimney (4) 233 1.333 729 175 1 0 0 8" x 20' 8 77.0 400 310 1.333 971 233 0 1 0 10" x 20' 10 77.0 JE500S 500 388 1.333 1213 291 0 0 1 12" x 20' 12 77.0 JE600S 600 465 1.333 1454 349 2 0 0 12" x 20' 12 77.0 JE700S 700 543 1.333 1696 407 1 1 0 12" x 20' 12 77.0 JE800S 800 620 1.333 1938 465 0 2 0 14" x 20' 14 77.0 JE900S 900 698 1.333 2183 524 0 1 1 14" x 20' 14 77.0 JE1000S 1000 775 1.333 2421 581 0 0 2 14" x 20' 14 77.0 JE1100S 1100 853 1.333 2667 640 1 2 0 16" x 20' 16 77.0 JE1200S 1200 930 1.333 2908 698 0 3 0 16" x 20' 16 77.0 JE1300S 1300 1008 1.333 3150 756 1 0 2 16" x 20' 16 77.0 JE1400S 1400 1085 1.333 3392 814 0 1 2 18" x 20' 18 77.0 JE1500S 1500 1163 1.333 3633 872 0 0 3 18" x 20' 18 77.0 Model Input (Mbh) (1) Gross Output (Mbh) JE300S 300 JE400S Net AHRI Ratings Right & Left End Tappings Data D A F B G B Opening Size Steam A 4” Supply and Return B 1/2” Primary LWCO and Gauge Glass set C 3/4” Drain, Left End C 3/4” Drain, Right End D 1/2” Plugged A E C E 1” Accessories *F 1” Safety Valve G 3/4” Plugged or Electronic (Probe Type) LWCO *If opening F is to be used for something other than the Safety Valve or Pressure Relief Valve, or the Safety/Relief Valve is larger than 1”, the Safety/Relief Valve must be installed in the Header Piping as near to the boiler as possible. Contractor Assistance: 800.325.5479 Base Size & Flue Outlet Thermal Efficiency 1. Ratings are at sea level to 2,000 feet. For altitudes above 2,000 feet, reduce all ratings 4% for each 1,000 feet above sea level. 2. Net steam ratings based on piping and pickup allowance of 1.333 (300-1500). Contact Technical Support before selecting boiler for installations having unusual piping and pick-up factors, such as intermittent system operations, extensive piping systems, etc. 3. Ratings in square feet are computed at 240 Btuh/square foot for steam boilers. 4. Chimney sizes shown are one option based on a typical venting system as shown in Figure 6 of the Installation Manual, and sized according to the National Fuel Gas Code, assuming Type B double wall vent and vent connectors, other venting system designs are acceptable as shown on Flue Connection And Venting section of the installation manual. For further chimney design and sizing information, consult the National Fuel Gas Code, ANSI Z223.1/NFPA 54-latest revision, or ASHRAE HVAC Systems and Equipment Handbook, Chimney, Gas Vent, and Fireplace Systems, or the Standard for Chimneys, Fireplaces, Vents, and Solid Fuel Burning Appliances. NFPA 211. Follow standard engineering practice. Certifications All ratings and specifications subject to change. P.O. Box 4729 Utica, New York 13504 tel: 315.797.1310 • fax: 315.797.3762 www.uticaboilers.com PN 240009442 Rev. 6/14
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Instance ID : uuid:565f2714-b559-d74e-b37c-b28fe9bdbb62 Original Document ID : adobe:docid:indd:64c10fb5-9344-11df-9e53-ba4cb7a41fa7 Document ID : xmp.id:AAF566582520681197A5D9849BD57CC3 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:A9F566582520681197A5D9849BD57CC3 Derived From Document ID : xmp.did:B8022A2C1F2068118A6DA6EFC45FA990 Derived From Original Document ID: adobe:docid:indd:64c10fb5-9344-11df-9e53-ba4cb7a41fa7 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2014:05:30 11:45:47-04:00 Create Date : 2014:05:30 11:45:47-04:00 Modify Date : 2014:05:30 11:45:59-04:00 Metadata Date : 2014:05:30 11:45:59-04:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2 Creator : Adobe InDesign CS6 (Macintosh)EXIF Metadata provided by EXIF.tools