SFE Series IV
There Are Some Things You Can Always Depend On...

SFE IV

82% AFUE Oil Fired Steam Boiler

• Available in 4 sizes from 106 MBH to 247 MBH.
• Dependable Cast Iron Heat Exchanger with Cast Iron Push
Nipples. The Sections and Push Nipples expand at the same rate
when heated. By using similar materials instead of less expensive
gaskets the boiler maintains a water tight seal over time.
• Patented Protective Heat Shield Baffle to protect the casting
above the water line.
• Honeywell Pressure Control, Boiler Water Level Gauge Glass,
and Steam Pressure Gauge.
• Electronic Low Water Cutoff.
• Atmospheric Chimney Vent Boiler.
• Textured paint Jacket with compact footprint.
• Cast Iron swing door and large flueways allow for easy
cleaning and servicing.
• 10 Year Limited Warranty (Residential Applications).
• Made in the U.S.A.

Utica SFE Series IV Residential Oil Fired Steam Boiler
Dimensional
Diagram

With
Tankless

Without
Tankless

Model

Front View
21.7/8”
9.1/32”
“C”

Elwco
Cycle
Guard

Pressure
Control

AHRI Oil
Burner Input(1)
G.P.H.

MBH(2)

Net AHRI
Min. Nat. Draft
Htg.
Pump
Ratings(3)
Chimney Size
Cap.
Press.
MBH(4) Steam Sq. Ft. Round Square PSI
MBH Steam

SFE-3090S

0.90

126

106

80

333

6"

8”x8”x15’

150

SFE-4125S

1.25

175

147

110

458

6"

8”x8”x15’

140

SFE-5185S

1.85

259

216

162

675

8"

8”x8”x15’

150

SFE-6210S

2.10

294

247

185

771

8"

8”x8”x15’

145

SFE-3090ST

0.90

126

106

80

333

6"

8”x8”x15’

150

SFE-4125ST

1.25

175

147

110

458

6"

8”x8”x15’

140

SFE-5185ST

1.85

259

216

162

675

8"

8”x8”x15’

150

SFE-6210ST

2.10

294

247

185

771

8"

8”x8”x15’

145

(1) Burner input is based on an oil heating value of 140,000 Btu/gal.

Nozz. AFUE %
(4)
Furn.
0.75-60°B

82.0%

1.50-70°B

82.0%

0.75-60°B

82.0%

1.50-70°B

82.0%

1.10-60°B

82.0%

1.75-70°B

82.0%

1.10-60°B

82.0%

1.75-70°B

82.0%

(2) MBH = 1000 Btu per hour [Btu = British Thermal Unit].
(3) N
 et AHRI Steam Ratings based on piping and pick-up allowance of 1.333. Consult manufacturer before selecting boiler for installations having unusual piping and
pick-up requirements, such as intermittent system operation, extensive piping, etc.
(4) H
 eating Capacity and AFUE based on 13.0% CO2 with -0.02” W.C. draft over fire and #1 smoke or less. Tested in accordance with U.S. Department of Energy test
procedures.

General Information (See Installation, Operation and Maintenance Manual for complete instructions)

Oil
Burner

Combustible Materials (Required)

Clearances

Required
distances
measured from boiler.

Top

6” (152 mm)

Right Side

24” (610 mm)

Front

24” (610 mm)

Back

24” (610 mm)

Flue Connector

9” (229 mm)

Connections
(All Models)

Supply Tapping Two 2”, Return Tapping 1-1/2”, Oil Line 3/8” O.D. copper tubing for runs of 50 feet or less,
and ½” O.D. for longer runs.

Electrical

120 Volts AC, 60 hertz, 1 phase, Less than 12 amps (15 amp circuit recommended).
Model

Input
Rate
G.P.H.

SFE-3090ST
SFE-4125ST
SFE-5185ST
SFE-6210ST

0.90
1.25
1.85
2.10

Side View

A.S.M.E. Pressure
Relief Valve
“B”

“A”

Tankless Heater
Capacities

35.3/4”

No. of
Sec.
16”

24” (610 mm)

Left Side

Dimensions/
Weights

Standard
Equipment

Options

Tankless
Heater Number

Tankless Heater
Capacity Intermittent
Draw G.P.M.

L-24

2
41/2
41/2
41/2

A
(Length of
Flush Jacket)

B
(Front of Jacket
to Center Line
of Flue Outlet)

Boiler Water
Content (Gallons)
To Water
To LWCO Line
Line
11
8
13
9
15
10
15
10

C
(Flue Outlet Diameter)

Weight

3
16 3/8”
61/2”
6”
534 lbs.
1
4
20 /4”
81/2”
6”
688 lbs.
5
23 5/8”
101/4”
7”
781 lbs.
6
271/2”
8 5/16”
8”
901 lbs.
Boiler Controls: Honeywell Pressuretrol, Boiler Water Level Gauge Glass, and Steam Pressure Gauge.
Heat Exchanger: Cast Iron Heat Exchanger with Cast Iron Push Nipples, Swing Door.
Combustion: Beckett Oil Burner, Target Wall/Liner.
Electrical: Wiring Harness, Burner Electric Disconnect.
Safety: Electronic Low Water Cut Off.
Other: Crated Boiler, Flush Jacket, ASME Relief Valve, Drain Valve, Plastic Cover, Two 2” Supply Tappings,
1-1/2” Return Tapping and Skim Port.
For Tankless Heater Units: Add Tankless Hot Water Coil and 4006 Limit Control.
Tankless Coil.

Certifications
Tested for 15 psi ASME
Working Pressure

PN 240009857 Rev. 4/14

All ratings and specifications subject to change.

Contractor
Assistance: 800.325.5479

P.O. Box 4729
Utica, New York 13504
tel: 315.797.1310 • fax: 315.797.3762
www.uticaboilers.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Instance ID                     : uuid:0d8dd5ae-2a1e-7645-aa3b-6568ede0f0b7
Original Document ID            : adobe:docid:indd:512815ae-3bc8-11e1-8bb3-984a65b969d7
Document ID                     : xmp.id:1FA3E1680F2068118083D5A09F8C05D0
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:1EA3E1680F2068118083D5A09F8C05D0
Derived From Document ID        : xmp.did:263491390F2068118083D5A09F8C05D0
Derived From Original Document ID: adobe:docid:indd:512815ae-3bc8-11e1-8bb3-984a65b969d7
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh)
History Changed                 : /
History When                    : 2014:04:16 11:23:45-04:00
Create Date                     : 2014:04:16 11:23:45-04:00
Modify Date                     : 2014:04:16 11:23:57-04:00
Metadata Date                   : 2014:04:16 11:23:57-04:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS6 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu