SFE Series IV There Are Some Things You Can Always Depend On... SFE IV 82% AFUE Oil Fired Steam Boiler • Available in 4 sizes from 106 MBH to 247 MBH. • Dependable Cast Iron Heat Exchanger with Cast Iron Push Nipples. The Sections and Push Nipples expand at the same rate when heated. By using similar materials instead of less expensive gaskets the boiler maintains a water tight seal over time. • Patented Protective Heat Shield Baffle to protect the casting above the water line. • Honeywell Pressure Control, Boiler Water Level Gauge Glass, and Steam Pressure Gauge. • Electronic Low Water Cutoff. • Atmospheric Chimney Vent Boiler. • Textured paint Jacket with compact footprint. • Cast Iron swing door and large flueways allow for easy cleaning and servicing. • 10 Year Limited Warranty (Residential Applications). • Made in the U.S.A. Utica SFE Series IV Residential Oil Fired Steam Boiler Dimensional Diagram With Tankless Without Tankless Model Front View 21.7/8” 9.1/32” “C” Elwco Cycle Guard Pressure Control AHRI Oil Burner Input(1) G.P.H. MBH(2) Net AHRI Min. Nat. Draft Htg. Pump Ratings(3) Chimney Size Cap. Press. MBH(4) Steam Sq. Ft. Round Square PSI MBH Steam SFE-3090S 0.90 126 106 80 333 6" 8”x8”x15’ 150 SFE-4125S 1.25 175 147 110 458 6" 8”x8”x15’ 140 SFE-5185S 1.85 259 216 162 675 8" 8”x8”x15’ 150 SFE-6210S 2.10 294 247 185 771 8" 8”x8”x15’ 145 SFE-3090ST 0.90 126 106 80 333 6" 8”x8”x15’ 150 SFE-4125ST 1.25 175 147 110 458 6" 8”x8”x15’ 140 SFE-5185ST 1.85 259 216 162 675 8" 8”x8”x15’ 150 SFE-6210ST 2.10 294 247 185 771 8" 8”x8”x15’ 145 (1) Burner input is based on an oil heating value of 140,000 Btu/gal. Nozz. AFUE % (4) Furn. 0.75-60°B 82.0% 1.50-70°B 82.0% 0.75-60°B 82.0% 1.50-70°B 82.0% 1.10-60°B 82.0% 1.75-70°B 82.0% 1.10-60°B 82.0% 1.75-70°B 82.0% (2) MBH = 1000 Btu per hour [Btu = British Thermal Unit]. (3) N et AHRI Steam Ratings based on piping and pick-up allowance of 1.333. Consult manufacturer before selecting boiler for installations having unusual piping and pick-up requirements, such as intermittent system operation, extensive piping, etc. (4) H eating Capacity and AFUE based on 13.0% CO2 with -0.02” W.C. draft over fire and #1 smoke or less. Tested in accordance with U.S. Department of Energy test procedures. General Information (See Installation, Operation and Maintenance Manual for complete instructions) Oil Burner Combustible Materials (Required) Clearances Required distances measured from boiler. Top 6” (152 mm) Right Side 24” (610 mm) Front 24” (610 mm) Back 24” (610 mm) Flue Connector 9” (229 mm) Connections (All Models) Supply Tapping Two 2”, Return Tapping 1-1/2”, Oil Line 3/8” O.D. copper tubing for runs of 50 feet or less, and ½” O.D. for longer runs. Electrical 120 Volts AC, 60 hertz, 1 phase, Less than 12 amps (15 amp circuit recommended). Model Input Rate G.P.H. SFE-3090ST SFE-4125ST SFE-5185ST SFE-6210ST 0.90 1.25 1.85 2.10 Side View A.S.M.E. Pressure Relief Valve “B” “A” Tankless Heater Capacities 35.3/4” No. of Sec. 16” 24” (610 mm) Left Side Dimensions/ Weights Standard Equipment Options Tankless Heater Number Tankless Heater Capacity Intermittent Draw G.P.M. L-24 2 41/2 41/2 41/2 A (Length of Flush Jacket) B (Front of Jacket to Center Line of Flue Outlet) Boiler Water Content (Gallons) To Water To LWCO Line Line 11 8 13 9 15 10 15 10 C (Flue Outlet Diameter) Weight 3 16 3/8” 61/2” 6” 534 lbs. 1 4 20 /4” 81/2” 6” 688 lbs. 5 23 5/8” 101/4” 7” 781 lbs. 6 271/2” 8 5/16” 8” 901 lbs. Boiler Controls: Honeywell Pressuretrol, Boiler Water Level Gauge Glass, and Steam Pressure Gauge. Heat Exchanger: Cast Iron Heat Exchanger with Cast Iron Push Nipples, Swing Door. Combustion: Beckett Oil Burner, Target Wall/Liner. Electrical: Wiring Harness, Burner Electric Disconnect. Safety: Electronic Low Water Cut Off. Other: Crated Boiler, Flush Jacket, ASME Relief Valve, Drain Valve, Plastic Cover, Two 2” Supply Tappings, 1-1/2” Return Tapping and Skim Port. For Tankless Heater Units: Add Tankless Hot Water Coil and 4006 Limit Control. Tankless Coil. Certifications Tested for 15 psi ASME Working Pressure PN 240009857 Rev. 4/14 All ratings and specifications subject to change. Contractor Assistance: 800.325.5479 P.O. Box 4729 Utica, New York 13504 tel: 315.797.1310 • fax: 315.797.3762 www.uticaboilers.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Instance ID : uuid:0d8dd5ae-2a1e-7645-aa3b-6568ede0f0b7 Original Document ID : adobe:docid:indd:512815ae-3bc8-11e1-8bb3-984a65b969d7 Document ID : xmp.id:1FA3E1680F2068118083D5A09F8C05D0 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:1EA3E1680F2068118083D5A09F8C05D0 Derived From Document ID : xmp.did:263491390F2068118083D5A09F8C05D0 Derived From Original Document ID: adobe:docid:indd:512815ae-3bc8-11e1-8bb3-984a65b969d7 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2014:04:16 11:23:45-04:00 Create Date : 2014:04:16 11:23:45-04:00 Modify Date : 2014:04:16 11:23:57-04:00 Metadata Date : 2014:04:16 11:23:57-04:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2 Creator : Adobe InDesign CS6 (Macintosh)EXIF Metadata provided by EXIF.tools