VALES and HILLS BIOMEDICAL TECH ICV200BLE ECG Acquisition System User Manual SELLER

VALES & HILLS BIOMEDICAL TECH. LTD. ECG Acquisition System SELLER

user manual

Download: VALES and HILLS BIOMEDICAL TECH ICV200BLE ECG Acquisition System User Manual SELLER
Mirror Download [FCC.gov]VALES and HILLS BIOMEDICAL TECH ICV200BLE ECG Acquisition System User Manual SELLER
Document ID3114652
Application IDo6TGe6WtEpzhXtatTNK5Hw==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize131.96kB (1649448 bits)
Date Submitted2016-08-29 00:00:00
Date Available2016-08-29 00:00:00
Creation Date2016-06-15 17:00:31
Document Lastmod2016-06-15 17:00:31
Document TitleSELLER
Document CreatorWPS Office
Document Author: Mickael REGULIER

®
CardioView® Family
iCV200(BLE) User Manual
VH-JS-08(60F)
Version A/0
VALES & HILLS BIOMEDICA TECH. LTD.
Tel: 0086-010-51665548
Fax: 0086-010-67856343
E-mail: sales@vhmedical.com
Website: http://www.vhECG.com
Address: Bldg 46-1, No2 North Street Jingyuan, Beijing Economic-technological Development
Area, 100176 Beijing, China
CARDIO SYSTEMES 6 rue Descartes 78370 PLAISIR France
®
CardioView® Family
iCV200(BLE) User Manual
Table of Contents
Preface.................................................................................................................................................................................. 3
1 iCV200BLE......................................................................................................................................................7
1.1About the iCV200(BLE).........................................................................................................................7
1.2List of packing ........................................................................................................................................ 8
1.3Accessories ..............................................................................................................................................8
2.Installation........................................................................................................................................................ 9
2.1 iCV200(BLE)ECG Acquisition Recorder............................................................................................9
2.2 Down Load vhECG HD from Apple App Store...............................................................................10
3.Electrodes Hookup.........................................................................................................................................11
3.1Hoopup...................................................................................................................................................11
4.Getting Start................................................................................................................................................... 12
4.1Recorder Setting.................................................................................................................................... 12
4.2Communication Between the Recorder and iPad............................................................................... 13
5.vhECG Resting ECG System........................................................................................................................14
5.1System Setting....................................................................................................................................... 15
5.2Patient Records Archive....................................................................................................................... 16
5.3Monitoring and Recording....................................................................................................................16
5.4Records Review.....................................................................................................................................17
5.4.1 Records State...................................................................................................................................17
5.4.2 ECG Review....................................................................................................................................18
5.4.3 Average ECG...................................................................................................................................19
5.5 VHCloud..................................................................................................................................................... 20
6.Cleaning and Maintenance............................................................................................................................21
7.Guidance and Manufacture’s Declarations..................................................................................................23
Annex I : iCV200(BLE) ECG Recorder Technical Specifications........................................................ 26
Annex II : Definitions and Rules For ECG Measurements.....................................................................27
®
CardioView® Family
iCV200(BLE) User Manual
Preface
Copyright
Copyright 2014, Vales and Hills (V&H). All rights reserved. No one is permitted to translate, reproduce
or duplicate this manual or any part thereof, in any form, without prior written permission from V&H,
V&H assumes no responsibility for any injury to anyone, or for any illegal or improper use of the
product, that may result from failure to use this product in accordance with the instructions, cautions,
warnings, or statement of intended use published in this manual. Unauthorized copying of this
publication may not only infringe copyright but also reduce the ability of V&H to provide accurate and
up-to-date information to users and operators alike.
The information contained in this manual is subject to change without notice. All changes will be in
compliance with regulations governing manufacture of medical equipment.
General Description and Intended Use
iCV200(BLE) is a portable ECG system with CardioView family. It includes a data acquisition recorder
and iPad with vhECG App. The system is designed and manufactured by V&H for patient ECG
recording with automatic measurements and interpretations.
 This product is not intended for use as sustain or support life devices.
 This product is not intended for introcardiac use.
 This product is not intended for use in operating room or ICU
 This product is not intended for infant.
The device is intended to provide reference for medical diagnosis, not intended for a replacement of
diagnosis clinicians.
Precautions
Radio Frequency (RF) interference between the iCV200BLE recorder or electrocardiograph and any
existing RF transmitting or receiving equipment at the installation site, including electrosurgical
equipment, in close proximity to the electrocardiograph should be evaluated before the equipment is
operated as they may seriously degrade performance.
The iCV200BLE is susceptible to interference from RF energy sources (lowered RF immunity) which
exceed the IEC 60601-1-2 limits, such as power line bursts, other medical equipment, cellular products,
information technology equipment and radio/television transmission.
To reduce EMC interference the cardiograph shall be separated from the emitting sources as much as
possible. If assistance is needed, call V&H service.
Artifact on the ECG caused by electromagnetic interference should be evaluated by a physician or
physician authorized personnel to determine if it will negatively impact diagnosis or treatment.
Like all electronic devices, this electrocardiograph is susceptible to electrostatic discharge (ESD). ESD
typically occurs when electrostatic energy is transferred to the patient, the electrodes, or the
electrocardiograph. ESD may result in ECG artifact that may appear as narrow spikes on the cardiograph
display or on the printed report. When ESD occurs, the electrocardiograph’s interpretation may be
inconsistent with the physician’s interpretation.
®
CardioView® Family
iCV200(BLE) User Manual
V&H assumes no liability for failures resulting from RF or ESD interference between V&H CardioView
series and any RF or ESD generating equipment when these levels exceed those established by
applicable standard.
Warnings
The electrocardiograph has not been designed for use with high frequency (HF) surgical equipment and
dose not protect against hazards to the patient.
Ensure the location of the electrode and associated cables provides maximum separation away from all
sources of HF energy. The best way to ensure patient safety is to completely remove all electrodes and
cables from the patient when exposed to HF energy.
Other medical equipment, including but no limited to defibrillators, ultrasound machines, pacemakers,
and other simulators, may be used simultaneously with the electrocardiograph. However, such devices
may disturb the electrocardiograph signal.
Can not touch the patient during Defibrillation.
This equipment has been tested and found to comply with the limits for a Class B digital device,pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
- Consult the dealer or an experienced radio/TV technician for help
Changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Warranty and Service
V&H provides a one-year warranty and life-time service to all CadioView series products. Repairs on
products under warranty must be performed or approved by V&H. Unauthorized repairs will void the
warranty. In addition, whether or not covered under warranty, any product repair shall exclusively be
performed by V&H certified service personnel.
Limited warranty statement
The warranty will not cover the damages caused by:
1) Use or maintenance contrary to labeled instructions
2) Alteration or repair by anyone not authorized by V&H
3) Accidents.
Troubleshooting
®
CardioView® Family
iCV200(BLE) User Manual
Most of the problem can be solved by contacting V&H service department support@vhmedical.com. To
get the prompt and efficient response you will provide:
 Product name and its serial number.
 A complete problem description
 The complete name, address and phone number of your facility
 For out-of-warranty repairs or spare parts order, a purchase order
 For parts order, the required spare or replacement part number
Product return
If the product has to be returned for service, V&H recommends these parking instructions:
 Wherever possible, use the original shipping carton and packing materials.
 Including a packing list.
 Including a problem description report.
It is recommended that all returned goods be insured. Claim for loss or damage to the product must be
initialed by the sender.
Unit disposal Instructions
Disposal of battery and the unit after the end of device life in municipally approved recycling area. The
life of device is 4 years.
Classification
Degree of protection against electrical shock
The power supply of ECG Acquisition box
Degree of protection against harmful ingress
of water
Degree of safety of application in the presence
of a flammable anesthetic mixture with air or
with oxygen or nitrous oxide
Method(s) of sterilization or disinfection
recommended by the manufacturer
Mode of operation
The defibrillation-proof recovery time
List of Symbols
Type CF, defibrillation-proof
2XAA Battery
Enclosed equipment without
protection against ingress of
water
Not suitable for use in the
presence of a flammable
anesthetic mixture with air or
with oxygen or nitrous oxide.
Sterilization: not applicable
disinfection: see user manual
Continuous operation
10s
®
CardioView® Family
iCV200(BLE) User Manual
Symbols
Meaning
Caution, consult accompanying documents.
SN
Serial Number(xxxxxxxxxxxxxxx)
Manufacturer
Date of manufacture
Authorized representative in the European community
The CE marking with the Registration Number of the Notified Body. This denotes
the compliance of European Medical Device Directive 93/42/EEC
Waste Electrical and Electronic Equipment (WEEE) It is the responsibility of the end
user to dispose of this equipment at a designated collection point for recycling.
DEFIBRILLATION-PROOF TYPE CF APPLIED PART
Bluetooth
Function switch button
Keep dry
temperature limits
Indicates the range of humidity to which the medical device can be
safely exposed.
IPX0
Against ingress of water with harmful effects : non-protected
---------------------------------------------------------------------------------------------------------------------------Warning: Warning statements describe conditions or actions that can result in personal injury or lost of life.
----------------------------------------------------------------------------------------------------------------------------Caution: Warning statements describe conditions or actions that can result in damage to the equipment of software.
----------------------------------------------------------------------------------------------------------------------------Note: Notes contain additional information on iCV200(BLE) usage.
®
CardioView® Family
iCV200(BLE) User Manual
1. iCV200(BLE)
 iCV200(BLE) Rest ECG for iOS (iPad, iPad-mini and iPhone)
Thank you for your purchase of iCV200(BLE) Resting ECG System and we hope that you will enjoy
working with it. If you have any comments or suggestions, we would appreciate hearing from you.
Please contact support@vhmedical.com
1.1 About iCV200(BLE)
iCV200(BLE) is a portable ECG system. It includes a data acquisition recorder and patient cable. The
system is designed and manufactured by V&H, The ECG Acquisition System is capable of sampling,
recording and analyzing patients resting ECG. This system is applicable to the heart disease analysis for
the medical treatment institution.
Fig1.1 iCV200(BLE) Rest ECG Composition
®
CardioView® Family
iCV200(BLE) User Manual
1.2 List of packing
The ECG Acquisition Systems consists of the following items:
Part No.
Description
QTY
EC G Ac quisi tion Box
iCV200 (BLE ) soft ware
(Note 1)
M0201120
ECG cable
CV060F-060
User manual
CV060F-010
Note1: About the software download please see 2.2 Download vhECG HD from Apple App Store.
1.3 Accessories
Item No.
CV-022010-M0201120
CV-021010-M0201044
Description
ICV200(BLE) patient cable
Standard Patient Cable
CV-040002
Battery
Intended Use
Cables allow connection to the
electrode leads, which adhere to
the patient for detection of ECG
signals
Power for ECG acquisition box
Note:
1. If any lead wire of lead part is failure, the user is unable to replace the lead wire, please contact with
V&H.
2. If any lead wire of lead part is failure, the user can replace the standard 6511ECG cable, the ECG
cable safety requirements tested for compliance with 93/42/EEC, should have the CE certificate. Vales
& Hills recommends Qingdao Bright medical, the model is M0201020.If use the manufacturer approval
attachment may reduce the safety of the products.
3.iCV200(BLE) is powered by two AA LR06 batteries.Insufficient of power may affect the
communication between the recorder and iPad.Check the batteries with adequacy of power before using.
If the power is low,the user can replace the new battery, Vales & Hills recommends the battery model is
AA LR06.
4.For the sake of environmental protection, please recycle disposal of the battery.
5.For products and accessories that are no longer used, it will be the cause of environmental pollution, it
should be properly treated.
6.Do not include standard Patient cable and battery when we sale.
7.If you find anything above is not included in the packing, please contact us by the following address:
Technical Support Dept. of Vales & Hills Biomedical Tech. Ltd.
Tel:0086-010-51665548
E-mail:service@vhmedical.com
Website: http://www.vhecg.com
Fax:0086-010-67856343
®
CardioView® Family
iCV200(BLE) User Manual
2. Installation
A complete iCV200(BLE) system consists of iCV200(BLE) data acquisition recorder and iPad or iPadmini with Apple App – vhECG HD. This section will guide you iCV200(BLE) recorder composition
and vhECG HD installation.
2.1Hardware Connection
iCV200(BLE) ECG Acquisition Recorder
Fig 2.1 iCV200(BLE) Recorder
®
CardioView® Family
iCV200(BLE) User Manual
iCV200(BLE) Connecting further accessories
The illustration on the Fig2.2 show further accessories and the interface where they are
connected.
patient
patient cable (F-TYPE APPLIED PART)
Bluetooth
ipad/iphone
iCV200(BLE) ECG acquisition box
Fig 2.2
2.2. Download vhECG HD from Apple App Store
iCV200(BLE) Resting ECG System has its software running on iPad or iPad-mini named vhECG HD
approved by
Apple.
Purchase
Find vhECG HD in App Store and download it wth your Apple ID and registered credit card.
Free Download
If you have got a promotion code from V&H, you can use it to download vhECG HD to your iPad or
iPad-mini free as following steps:
Step 1. Login with your Apple ID (Settings → Store). If you do not have an Apple ID, you can create
one with your e-mail address.
Step 2. In AppStore, scroll to the bottom and find  button.
Step 3. Click , and then enter your promotion code in the popup dialog.
Step 4. After step 3, you will be asked to enter your Apple ID password again.
Step 5. Download in process and you get vhECG HD
Note: The promotion code is valid within four weeks.You should download vhECG HD within this
period.
10
®
CardioView® Family
iCV200(BLE) User Manual
If you have any questions about vhECG HD download, please contact support@vhmedical.com.
3. Electrodes Hookup
3.1 Hookup
11
®
CardioView® Family
iCV200(BLE) User Manual
4. Getting Start
The communication between iPad and iCV200(BLE) Recorder is through Bluetooth.
iCV200(BLE) Resting ECG System for iPad is vhECG. It currently runs with the following languages:
The running language of vhECG depends on your iPad language setting. The default language is English,
that means if your iPad sets the language not belong to above selections, vhECG will run in English.
vhECG will support more languages in progress. V&H appreciates your participations in vhECG
development.
4.1 Recorder Setting
Referring to 2.1 to get the  explaining.
The communication between iCV200(BLE) recorder and iPad is through Bluetooth.
Battery: Set two AA batteries into the recorder.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Page Count                      : 29
Author                          : Mickael REGULIER
Comments                        : 
Company                         : 
Create Date                     : 2016:06:15 17:00:31+09:00
Creator                         : WPS Office
Modify Date                     : 2016:06:15 17:00:31+09:00
Producer                        : 
Source Modified                 : D:20160615170031+09'00'
Subject                         : 
Title                           : SELLER
Trapped                         : false
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AIE3ICV200BLE

Navigation menu