VISSANI Wine Cooler Manual L0911228
User Manual: VISSANI VISSANI Wine Cooler Manual VISSANI Wine Cooler Owner's Manual, VISSANI Wine Cooler installation guides
Open the PDF directly: View PDF .
Page Count: 11
Download | |
Open PDF In Browser | View PDF |
TM BI SO RIGHT AT HOME. TM STAINLESS STEEL BUILT-IN WINE COOLER WITH DUAL TEMPERATURE ZONES AND TOUCH-SCREEN CONTROL PANEL INSTRUCTION MANUAL Model No.: MCWC44DZ L :l To ensure proper use of this appliance and your safety, please read the following instructions completely before operating this appliance. TABLE OF CONTENTS NAMES OF THE PARTS ........................................................................................ SPECIFICATIONS IMPORTANT .................................................................................................... SAFETY INSTALLATION INSTRUCTIONS BUILT-IN INSTALLATION INSTALLATION ELECTRICAL FEATURES ......................................................... 3 ........................................................ 3 ............................................................................. 4 CONNECTION ................................................................. .......................................................................................... 4 5 YOUR APPLIANCE TEMPERATURE INDICATOR STAND CONTROL LIGHT AND DISPLAY ........................................... 6 ...........................................................................................6 BY ................................................................................................................. 6 LOCK AND UNLOCK TEMPEP, ATURE INTERIOR AUTOMATIC ..................................................................3 USING YOUR APPLIANCE FREE STANDING OPERATING 2 INSTRUCTIONS BEFORE APPLIANCE 2 ........................................................................................... 6 SETTING ................................................................................ 7 LIGHT ............................................................................................ 7 DEFROST ........................................................................................... 7 CARE AND MAINTENANCE CLEANING YOUR APPLIANCE VACATION TIME .................................................................................................8 MOVING YOUR APPLIANCE ENERGY SAVING TROUBLESHOOTING APPLIANCE .....................................................................8 ................................................................... 8 TIPS ................................................................................. 8 GUIDE ......................................................................................9 WARRANTY ......................................................................................... ! 10 EN NAMIES OF THE PARTS MODEL t) NO.: Interior MCWC44DZ Light 2) DC Electric Fan 3) Zone Partition 4) Inner rear 5) Wine Shelf 6) Door Handle 7) Partition Gasket 8) Tempered Glass Door (Touch-Screen Control Panel is on the front SPECIFICATIONS of the Glass Door.) - Mlodel # IVlCWC44DZ 44 Bottle Built-In Wine Cooler Product Description with Dual Temperature Zones and Touch-Screen Control Panel Model No. Unit Dimensions MCWC44DZ Width Height Depth 23.4" 34.4" 24.4" ( inches ) Net Weight (Ibs) 1041bs 2 EN iMPORTANT SAFETY iNSTRUCTiONS _f'WARNING/V • o o o • ° ° To reduce the risk of fire, electrical shock, or injury when using your appliance, follow these basic precautions: Read all instructions before using the wine cooler. DANGER orWARNING: Risk of child entrapment. To avoid the possibility of child entrapment, please take the following precautions before throwing out the appliance.. Remove all doors from the unit_ Leave the shelves in place so that children may not easily climb inside.. Never allow children to operate, play with, or crawl inside the appliance. Refrigerants: All refrigeration products contain refrigerants, which under the guidelines of federal law must be removed before disposal of product. It is the consumer's responsibility to comply with federal and local regulations when disposing of this product, Never clean appliance parts with flammable fluids, The fumes can create a fire hazard or explosion. Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of this or any other appliance.. The fumes can create a fire hazard or an explosion -Save these instructions- iNSTALLATION INSTRUCTIONS Before Usinq Your Appliance ° Remove the exterior and interior packing. • Before connecting the appliance to the power source, let it stand upright for approximately 4 hours., This will reduce the possibility of a malfunction in the cooling system from improper handling during transportation, • Clean the interior surface with lukewarm water using a soft cloth,, (Cleaning instruction on page 8) Free-Standinq Installation • This applianceis designed to be installed built-in or free standing,_ • Locate the appliance away from direct sunlight and sources of heat (stove, heater, radiator, etc.).. Direct sunlight may affect the acrylic coating and heat sources may increase electrical consumption, Ambient temperature below 68°F (20°C) or above 90°F (32°C) will hinder the performance of this appliance. This unit is not designed for use in a garage or any other outside installation. • Avoid locatingthe appliancein moist areas ° Plug the appliance into dedicated, properly installed-groundedwail outlet, Do not under any circumstancescut or remove the third (ground) prong from the power cord.,Any questions concerning power and/or groundingshould be directed toward a certified electrician or an authorizedservice center.,This unit is not designed to be installed in an RV or used with an inverter. ° After pluggingthe appliance into a wall outlet, turn the uniton and allow the unitto cooldown for 3 - 4 hours before placingwine bottles in the appliance, 3 EN Built-In Installation The cutout dimension illustrated in figure (A) allows for door swing and access to the pull-out shelves when installed as a built-in appliance. If installing between frametess cabinets, a 1/_,,wide fiUer strip or side panel may be needed on hinge side.. The filler strip will act as a spacer between the appliance case and adjacent cabinet door swing. The width of the opening must include the filter panels.. E ...........,.....[' _[7 ..... =I-N_= .......... . :i Note: The door should protrude at least 1" beyond the surrounding cabinets.. ll-l;}" li '_, Figure A The cutout de_th must be 24'L Electrical Connection tVWARNING improper use of the grounded plug can result in the risk of electrical shock, if the power cord is damaged, have it replaced by an authorized service center. This appliance should be properly grounded for your safety., The power cord of this appliance is equipped with a three-prong plug which mates with standard three prong wall outlets to minimize the possibility of electrical shock. Do not, under any circumstances, cut or remove the third ground prong from the power cord supplied.. This appliance requires a standard 1t5 Volt A.C. t60Hz electrical outlet with three-prong ground, This appliance is not designed to be used with an inverter_ The cord should accidental injury, be secured behind the appliance and not left exposed or dangling to prevent Never unplug the appliance by pulling the power cord, Always grip the plug firmly and pull straight out from the receptacle. Do not use an extension cord with this appliance.. If the power cord is too short, have a qualified electrician or service technician install an outlet near the appliance Use of an extension cord can negatively affect the performance of the unit. If any problems with the appliance persist, please contact our Customer Service DepL to consult with a representative at 888 775.0202 or visit our website to request warranty service at wv,-,v,mcapplia nce.com, 4 EN APPLIANCE Touch-screen . FEATURES Control Panel Touch-screen control panel is on the front of glass door for convenient temperature reading and setting,, You can easily read the zone temperature without opening the door and control your unit just by touching the screen., For details of temperature setting, please see "Operating Your Apptiance"_ (pg, 6-7) Two Temperature Zones ° There are two zones in this appliance divided by a partition. . Each zone has its independent temperature control and display ° The upper zone can hold up to 16 bottles, The Iowerzone can hold up to 28 bottles. Interior Light ° Each zone has its own interior light, which can be switched on or off by pressing the pad O (light) on the control panel. Long-life and high efficiency LEDs are installed for durability and energy efficiency,, Upper Zone ° There are two wine shelves of full depth in the upper zone, Each shelf can holds up to 8 bottles with the bottle necks alternating front to back. ° The second supporting guide in the upper zone (counted from top, see illustration "A" on this page) is not designed for wine shelves,, Lower Zone ° o There are also two wine shelves of ful! depth in the lower zone., Each shelf can holds up to 8 bottles with the bottle necks alternating front to back, The bottom rack in the lower zone, which consists of two stories, each holds up to 6 bottles with bottle necks facing the front (see illustration below on this page) Engaged Wine Shelves ° All the wine shelves have tabs to engage the cabinet on both sides, . Any of the shelves can be removed to accommodate larger bottles, To Remove a Shelf: . Remove all bottles from the shelves. ° Lift the shelve upwards and then gently pull out the shelves To Replace a Shelf: ° Place the sides of the shelves back onto the supporting guides of the cabinet and push back until the shelf tabs slide into place., NOTE: Ensure that the tabs are firmly engaged in place before storing ! A . -_'_••_ any bottles, i! • , t_:_- _ ,',_..'._,"-" :.._.-,l_ 5 EN OPERATING YOUR APPLIANCE Temperature 1. 2. 3, 4. 5. Control and Display The temperatures in upper zone and lower zone can be independently controlled and displayed,, The temperature in either zone can be controlled between 39°F to 61°F (4°C to 16"C)., (The zone temperature may have a tolerance of +t-5°F (+k3"C) from setting depending on different loading and ambient conditions..) The temperature display, indicator C), control pads O (warmer) and O (colder) near the symbol [] (left side) are for upper zone of the wine cooler.. The temperature display, indicator Q, control pads O (warmer) and O (colder) near the symbol [] (right side) are for lower zone of the wine cooler. The indicators _ and [], and the control pads _ (lock) and O (light) are for both zones. Indicators Liqhts e @ When lit, the _ indicator light indicates that the unit is in the "Stand by" mode, When lit, the r_ indicator light indicates that all of the control pads are locked and no adjustment can be made to the unit When lit, the Q indicates that the corresponding zone is in the refrigeration cycle (compressor is running),. The C) indicator will go off once the desired temperature is reached, Note: The C) light will remain on and the compressor may continue to run for several minutes after the desired temperature is reached. When the unit is plugged in all of the display indicators will light for 3 seconds and an audible beep will be heard., The unit wilI automatically resume the previous settings from when the unit was unplugged_ If the unit was previously in the "Stand By" mode when unplugged it will resume in the "Stand By" mode and the _ indicator will be IlL I,, ,, You can manually set the unit to the "Stand By" mode by pressing and holding both the 0 and _) pads simultaneously of the lower zone located on the right side of the control panel for approximately 3 seconds, The control pad must be "unlocked" to set the unit to the "Stand By" mode., The _ indicator light will illuminate to confirm this setting., Lock and Unlock The lock feature is designed to prevent the settings of your wine cooler from being adjusted accidentally., In order to adjust any of the settings you must unlock the control panel by pressing the "lock" pad for approximately 3 seconds. Once the unit is unlocked an audible beep will be heard and the "lock" indicator light will go out If no selection is made to adjust the unit in approximately automatically return to the "lock" mode, one minute the control panel will To lock the unit manually press the "lock" pad,, 6 EN Temperature settinq o Unlock the control panel by pressing the -_, pad for approximately 3 seconds Once the control panel is unlocked an audible beep will be heard and the ,_-indicator will go ouL ° Under normal conditions the temperature display indicates the current temperature of the corresponding zone.. When adjusting the temperature, the temperature display will flash to indicate that the temperature is being adjusted. ° The temperature in both upper zone and lower zone can be set independently by pressing O (warmer) or O (colder) pads that correspond to desired zone. The temperature range of both zones can be set between 39°F to 6t°F (4 ° to 16°) +1- 5"F_ When the pad O (warmer) or O (colder) is pressed, the temperature displayed will increase or decrease in an increment of one degree, If the pad O (warmer) or O (colder) is pressed and held for 2 seconds, the temperature displayed will increase or decrease in a speed of one degree per half second. Once you have adjusted the upper or lower zone to the desired temperature, release the temperature pad. At this time the temperature displayed will flash for approximately 3 seconds to confirm the selected temperature. Once the display stops flashing the temperature display will indicate the current temperature of that zone Note: The temperature display can be changed between Celsius and Fahrenheit by simultaneously pressing and holding both pads O (warmer) and O (colder) for the upper zone for approximately 3 seconds. This unit cannot be in _ (Lock) mode to perform this operation.. Interior L_ To turn on / off the interior light, press the _ (Light) pad. The unit cannot be in the [] (Lock) mode to perform this operation. Note: The light will turn on / off after the touch pad is released. AUTOMATIC DEFROST There is no need for manual defrosting of this appliance due to automatic defrosting function. • The ice build-up on the inner back wall during compressor operation will be automatically defrosted in a compressor off cycle. ° When defrosting is in process, the indicators C) for both zones will go off, and the circulation fans for both zones will run o Defrost water wil! drain out passing through the drain outlet in the inner back wall into a drain pan located above the compressor, from where it evaporates.. 7 EN CARE AND MAINTENANCE Cleaninq Your Appliance o ° o Upon installation of your new appliance, it is recommended that it be cleaned thoroughly. Turn off the appliance first and then unplug the unit from the wall outlet., Remove all contents. = Wash the inside with a damp warm cloth soaked in lukewarm water and baking soda solution,. The solution should be about 2 tablespoons of baking soda to a quart of water., Be sure to keep the door gasket (seal) clean to keep the unit running efficiently., The outside of the appliance should be cleaned with mild detergent and warm water, Dry the interior and exterior with a soft cloth.. Dust or anything else blocking the vent may hinder the cooling efficiency of the appliance.. Vacuum the vent if necessary. ° ° ° ° Vacation Time ° • Turn off the appliance first and then unplug the unit from the walt outlet.. Remove all the contents ° • ° ° Clean the appliance. Leave the door open slightly to avoid possible formation of condensation, mold, or odors. Short vacations: Leave the appliance operating during vacations of less than three weeks, Long vacations: If the appliance will not be used for several months, remove all content and unplug the power cord. Clean and dry the interior thoroughly. To prevent odor and mold growth, leave the door open slightly: blocking it open if necessary. Movinq Your Appliance o = Turn off the appliance first and then unplug the unit from the wall outlet. Remove all the contents. o ° Securely tape down all loose items inside your appliance,, Tape the doors shut. Enercly Savinq Tips ° The appliance should be located in the coolest area of the room, away from heat producing appliances or heating ducts, and out of the direct sunlight. • Ensure that door is closed when the appliance is turned on., 8 EN TROUBLESHOOTING GUIDE You can solve many common appliance problems easily, saving you the cost of a possible service call Try the suggestions below to see if you can solve the problem before calling for service, PROBLEM Appliance POSSIBLE CAUSE does not operate, Temperature inside the appliance is too warm. Temperature inside the appliance is too cold. Not plugged in The circuit breaker tripped or a blown fuse. Temperature control is set too warm, Turn the control to a cooler setting and allow several hours for the temperature to stabilize, Door is kept open too long or is opened too frequently., Warm air enters the appliance every time the door is opened Open the door less often., The door is not closed completely, The door gasket does not seal properly The appliance has recently been disconnected for a period of time, 4 hours are required for the appliance to cool down completely. Temperature control is set too cold. Turn the control to a warmer setting and allow several hours for the temperature to stabilize. Check to assure that the appliance is on a level surface, The appliance is touching the wall Re-level the appliance and move it from the wall, If continued vibration occurs, turn off the appliance and unplug the power plug, Contact Customer Service Dept. for further assistance. Door is slightly open Door is kept open too long, or is opened too frequently, Open the door less often. The door is not sealed properly. ,......... Door is slightly open. causing cold air from inside the appliance to meet warm moist air from outside. The appliance is not on a level surface, The gasket is dirty. "El" on display for upper zone - error of temperature sensor for upper zone "E2" on display for lower zone - error of temperature sensor for lower zone_ "E3" on display for tipper zone - error of DC electric fan for tipper zone,, "E4" on display for lower zone - error of DC electric fan for lower zone. if any of above errors happens, please contact Customer Service DepL for further assistance Do not attempt to repair it yourself. Vibrations, Moisture forms on inside appliance walls Moisture forms on outside of appliance, The door will not close properly, Abnormal display on control panel 9 EN Magic SO Chef RIG|IT AT Appliance TM 11 OMEJ" Warranty MC Appliance Corporation warrants each new appliance to be free from defects in material and workmanship and agrees to remedy any such defect or to fl_rnish a new part(s) (at the company's option) for any part(s) of the unit that has failed during the warranty period Parts and labor expenses are covered on this unit for a period of one year after the date of purchase In addition, MC Appliance Corp warrants the compressor (parts only) to be free from defects in material and workmanship for a period of 5 years The consumer is responsible for all labor and transportation expenses related to the diagnosis and replacement of the compressor after the initial one-year warranty expires if in the event that the unit is determined to be non-repairable under the terms of this warranty, the consumer is responsible for all transportation expenses to return the unit to our factory prior to receiving a refund A copy of the dated sales receipt / invoice is required to receive warranty service or a refund. This warranty covers appliances in use within the continental Rico and Hawaii. The warranty does not cover the following: . . = = . = = = • = = United States, Puerto Damages due to shipping damage or improper installation Damages due to misuse or abuse Content losses due to failure of the unit Inside components such as door panels, door shelves, racks, light bulbs, etc Punctures to the evaporator system due to improper defrosting of the unit Repairs performed by unauthorized service agents Service calls that do not involve defects in material and workmanship such as instruction on proper use of the product, door reversal or improper installation Replacement or resetting of house fuses or circuit breakers Failure of this product if used for other than for its intended purpose Disposal costs for any failed unit not returned to our factory Any delivery costs incurred as the result of a unit that fails to perform as specified This warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume for us any other liability in connection with the sale of this product. Under no circumstances is the consumer permitted to return this unit to the factory without prior written consent from MC Appliance Corporation. Model Parts Labor Compressor (part only) Type of Service MCWC44DZ One-Year One-Year Five-Year In-Home For Service or Assistance please call 888 775- 0202r Or visit us on the web at www.mcappliance.com to request warranty service ]0 EN
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 11 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 4, 0, 0, 13 Create Date : Wed Nov 18 04:18:45 2009 Author : Title : Subject :EXIF Metadata provided by EXIF.tools