Vecima Networks PA700 Amplidier User Manual ml pa700 03

Vecima Networks Inc. Amplidier ml pa700 03

Users Manual

                                 700 MHz Band Power Amplifier  PA700-T740_746   INSTALLATION AND OPERATION GUIDE FOR SYSTEM OPERATORS
   VCom Inc. PA700 Manual; ml_pa700_03 (January 2005) Approved: C.H. ii                                  Proprietary to VCom Inc. All rights reserved. No part of this publication may by reproduced in any form or by any means or used to make any derivative work (such as translation, transformation or adaptation) without written permission from VCom Inc. VCom Inc. reserves the right to revise this publication and to make changes in content from time to time without obligation on the part of VCom Inc. to provide notification of such revision or change. VCom Inc. provides this guide without warranty of any kind, either implied or expressed, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. VCom Inc. may make improvements or changes in the product(s) described in this manual at any time. PA700 Manual; ml_pa700_01 (November 2004); Approved: C.H. Specifications subject to change without notice — Printed in Canada
   VCom Inc. PA700 Manual; ml_pa700_03 (January 2005) Approved: C.H. iii   Thank-you for purchasing this product and welcome to VCom!  You have chosen an innovative solution from a leading technology design center in the ongoing TV & data delivery revolution.   No doubt you’ve been thinking that the future of your television delivery system includes new technologies such as Digital TV, Internet Over Cable, Wireless Cable.  By selecting VCom, you are benefiting from the same design powerhouse that since 1988 has created custom RF and digital products for technology leaders such as AT&T, Cisco Systems, Cogeco, Comcast, and Cox Communications.    VCom designs and manufactures:  Agile CATV Modulators     256 QAM Upconverters     Digital Video Modulators  Frequency Translators     Spread Spectrum Devices   MMDS Transceivers  Off Air/CATV Demodulators   Wireless Cable MMDS     Wireless Cable LMDS  Video On Demand Products     and more!  Designs to fill the market needs of the CATV industry – both foreign and domestic.  For additional product or corporate information, contact us:  On the web at:    www.vcom.com By sending email to:  sales@vcom.com By telephone:    (306) 955-7075 By fax:      (306) 955-9919 By snail mail:    VCom Inc. 150 Cardinal Place Saskatoon, SK  Canada S7L 6H7              VCom's Corporate Mandate is to be a leading worldwide designer and manufacturer of state-of-the-art communications equipment and components.  Through the remarkable success of our customers and business partners, VCom innovations are achieving this goal.
   VCom Inc. PA700 Manual; ml_pa700_03 (January 2005) Approved: C.H. iv   SAFETY PRECAUTIONS  1. Before installing and operating this equipment, read all Safety, Installation and Operating sections. Retain this manual for future reference. 2. Follow all instructions — Failure to do so may result in damage to the unit or severe personal injury. 3. Servicing should not be attempted by the user. There are no user serviceable parts inside. Refer all servicing to factory qualified personnel. 4. Cleaning — Do not use liquid or aerosol cleaners. Use a damp cloth for cleaning. Warning Do not work on the system or connect or disconnect cables during periods of lightning activity. LES PRÉCAUTIONS DE SÉCURITÉ    1. Avant d'installer ou d'opérer cet équipement, lisez, toutes les sections de sécurités, d'installations et d'opérations.  Gardez ce manuel comme source de référence.  2. Suivez toutes instructions - si non, vous risquez d'endommager la machine ou de vous blesser sérieusement.  3. N'essayez, pas de réparer cet équipement vous même.  Référez toutes revisions nécessaire au personnel qualifié de la manufacture.  4. Le nettoyage - n'utilisez pas de nettoyeurs aérosols ou liquides.  Utilisez un tissu humide pour nettoyer. Attention Ne pas travailler sur le système ni brancher ou débrancher les câbles pendant un orage du foudre.      ☛         Important Installation Instructions
   VCom Inc. PA700 Manual; ml_pa700_03 (January 2005) Approved: C.H. v INDEX 1.0 GENERAL INFORMATION......................................................................................................... 6 1.1 Functional Overview................................................................................................................................6 1.2 Features.....................................................................................................................................................6 1.2.1 Amplifier Features:...............................................................................................................................6 1.2.2 System Features (with UCD4940): ......................................................................................................6 2.0 INSTALLATION.......................................................................................................................... 11 2.1 Unpacking the Unit................................................................................................................................11 2.2 Installing the Unit...................................................................................................................................11 3.0 Connection With MSM................................................................................................................. 13 5.0 WARRANTY STATEMENT AND SERVICE POLICY............................................................ 16 5.1 Warranty Statement ..............................................................................................................................16 5.2 Service Policies: How to Return an Item for Service:.........................................................................16 5.3 Repair Charges and Warranty Exemptions ........................................................................................17
   VCom Inc. PA700 Manual; ml_pa700_03 (January 2005) Approved: C.H. 6 The PA700-T740_746 is a solid state, fixed gain power amplifier for operation in the US 700 MHz frequency band. Advanced LDMOS design permits the PA700 to operate with high level digital signals such as 64QAM, DVB-T or 8-VSB DTV. The PA700 can be operated on a stand-alone basis or controlled via SNMP or front panel display when serially connected to a UCD4940. Together, the PA700 and UCD4940 offer a complete solution for up-conversion, down-conversion and high linearity amplification in a rack mount configuration requiring only 4U of rack space*. This advanced, cost effective power amplifier offers high performance and flexibility in a space-efficient design.  The unit is state of the art in terms of easy assembly, reliability and performance.   The PA700 is factory configured and calibrated for operation at a specific band.    !• 80W typical transmit power with 64QAM or DVB-T modulation • Alarms and automatic protection for RF faults, over-temperature, over-drive, output VSWR, and over-current • Enable/disable via front panel switch or two pole rear connector • Monitor and control via RS232/RS485 • International switching power supply (100 to 240 VAC)  "#$%&'()*)+!• Local control via LCD and 4 soft touch push buttons • Remote control and monitoring via RS232/RS485, Terminal or optional SNMP • Automatic level control • 44 MHz input for up-conversion and amplification of IF modulators or Cable Modem Termination Systems
   VCom Inc. PA700 Manual; ml_pa700_03 (January 2005) Approved: C.H. 7 ,"   RF Output Frequency   740 to 746 MHz Linear Output Power   +49 dBm (80W) Gain       56 dB ± 2 dB, fixed Gain Flatness     ±0.3 dB over 6 MHz Spurious   Inband   -55 dBc   Out of band   -55 dBc Input/Output Connectors   N female, 50 ohms Input Return Loss   16 dB Output Return Loss   18 dB RF Monitor       SMA female, 50 ohms RF Monitor Port    -42.5 ± 2 dB MONITORING AND ALARMS Remote Control Interface   Standalone   RS232 via DB9, RS485 via RJ45   With UCD4940**   Front panel LCD push button, RS232/RS485, Terminal       (RJ45) or optional SNMP over 10BaseT ethernet Status/Alarms     Enable, RF fault, Over-temperature, Input Over-drive,       Over-current, Max. Reflected Output power Exceeded Monitors (with UCD4940)   RF Input Power, RF Output Power, Temperature,       Supply Voltage, Automatic Protection       Over-temperature, Input Over-drive,       Reflected Output Power, Over-current LED Indicators     Power Supply OK, Alarm, Enable MISCELLANEOUS Dimensions       17.25” (w) x 18” (d) x 5.25” (h) (43.8 x 45.7 x 13.3 cm) Mounting       Standard 19” rack - 3U (5.25”) Weight       33 lbs. (15 kg.) Operating Temperature   0 to 45°C Power Requirements   100 to 240 Vac, 50 to 60 Hz\ Power Consumption  500W maximum        * Rack space for output filtering not included. ** When configured for monitoring via the UCD4940, the standalone terminal interface is disabled.   Specifications subject to change without notice.
   VCom Inc. PA700 Manual; ml_pa700_03 (January 2005) Approved: C.H. 8 )-DIAGRAM 1.4A: PA700 FRONT PANEL
   VCom Inc. PA700 Manual; ml_pa700_03 (January 2005) Approved: C.H. 9 DIAGRAM 1.4B: PA700 REAR PANEL  
   VCom Inc. PA700 Manual; ml_pa700_03 (January 2005) Approved: C.H. 10 DIAGRAM 1.4C: PA700 SIDE AND TOP VIEW
   VCom Inc. PA700 Manual; ml_pa700_03 (January 2005) Approved: C.H. 11  "&./%&Carefully remove the equipment from its packing material and set it on a solid surface, such as a table or desk. If it appears damaged in any way, notify the carrier, and keep all packing materials for inspection by the carrier’s agent.  /%& Note:  This unit should be installed by qualified service personnel only.  Diagram 2.2 details the input and output connections for the PA700.  1.  Carefully identify between the electrical ground of the AC power supply and the station ground that is common to the antenna system, other RF components and the transmitter rack cabinet.  Ensure that the PA700 and the CMTS ground points are connected to the station ground and not the electrical ground. 2.  If installing the PA700 into an equipment rack, use the 4 mounting holes on the front of each cabinet.  It is also important to connect the rear side of the PA700 chassis to the same rack cabinet using a rear support bracket (not supplied).  3.  It is suggested that a heavy gauge line cord (No. 10 AWG stranded) with connector be used in most applications for connection to the AC power supply.  The AC power connector and station ground stud are located on the rear panel (refer to Diagram 1.4B). 4.  Prior to connection, please ensure that the frequency, modulation and BW of the CMTS or CMTS/upconverter are set for the application.  PA700 type approval for the US lower 700 MHz band under FCC Part 27 is only valid for the following input frequency and modulation combinations and only when the VCom duplexer is connected between the output and the antenna.  Carrier Bandwidth  Center Frequency Range  Modulation 2 MHz  741-745 MHz  QPSK, 16QAM, 64QAM 6 MHz  743 MHz only  QPSK, 16QAM, 64QAM  5.  Adjust the input level so that the input power to the unit is nominally -7 dBm. 6.  Connect both upconverter/CMTS to unit and duplexer/antenna assembly 7.  Adjust input level so that output power is +48 to +49 dBm as reported by MSM server or the UCD4940.  Opeartion below this level will result in less than optimal performance and operation above this level may violate regulatory emissions requirements.      WARNING! Maintain a distance of at least 10mm (3/8 “) between PA700 units when mounting several units in a rack.   The rear air outlets should be unobstructed.
   VCom Inc. PA700 Manual; ml_pa700_03 (January 2005) Approved: C.H. 12 DIAGRAM 2.2: PA700 SYSTEM CONNECTIONS
   VCom Inc. PA700 Manual; ml_pa700_03 (January 2005) Approved: C.H. 13 ,''01" In order for the PA700 to be monitored by the MSM software package, the PA700 must be connected to the MSM server computer as illustrated in diagram 3.1.  The required cables are included with the AC3000 kit.   DIAGRAM 3.1: CONNECTION WITH MSM
   VCom Inc. PA700 Manual; ml_pa700_03 (January 2005) Approved: C.H. 14 )&2"1 “My amp is cutting-in/cutting-out repeatedly” “My amp is unstable”  The amp may be in shutdown mode due to an input level that is too high, or due to a high amount of reverse-power being detected.  Reverse-power is really reflected power – often caused by a fault between the PA700 and the antenna, or by operation at a frequency outside of the DPX700 passband.  All LEDs are off   • Ensure that the PA700 is plugged in to the power source   • Check the FUSE led on rear panel; if the light is on, replace the fuse   • If failure persists please contact technical support  Only the MAINS led light is on, but enable does not work   • Check that all three enables (LOCAL, REMOTE, SOFTWARE) are present   • Check RF IN, RF REF and TEMPERATURE alarms  Enable ON, VDC absent    • Possible power supply fault  Enable and VDC ON, RF Output Power Absent   • Check that the input is valid   • Check for alarms.  Some conditions result in muted output power.  Frequently occurring thermal protection conditions   • Check that air outlets are not obstructed   • Check the amount of dust on heatsink   Amplifier VSWR alarm condition   • Too much power is being reflected by the antenna/duplexer/cable feed • Verify that connections and cables are intact • Impedance at the duplexer must be 50 ohm   Amplifier mute due to over-drive   • Check the input level • Input level and amplifier gain should not exceed +49 dBm  No gain   • Check the input and alarms  Too high output distortion   • Check the output power level.  Output should not exceed 49 dBm.
   VCom Inc. PA700 Manual; ml_pa700_03 (January 2005) Approved: C.H. 15 No RS232 communication   • Press reset (this may result in a service interruption)   • Check the connector on front panel   • If failure persists please contact technical support  No RS485 communication   • Press reset (this may result in a service interruption)   • Check the connector on rear panel   • Disconnect RS232 com and press reset   • If failure persists please contact technical support
   VCom Inc. PA700 Manual; ml_pa700_03 (January 2005) Approved: C.H. 16 304"("5'-'430#"VCom warrants its products to be free from defects in workmanship or materials for a period of two years.  The warranty begins on the date of the original shipment from VCom to its customer.  No claim may be allowed for expenses incurred in installation or use.  No other expressed or implied warranties shall apply to the goods sold. VCom is not responsible for delayed shipments, other loss beyond VCom’s control, or consequential damages of any kind arising in connection with the use of its products.  This warranty is a return-to-factory warranty only.  During the warranty period VCom will at its option, replace, repair or refund the price paid for any item which is returned for service.  This warranty does not apply to units that have been physically or environmentally abused. 3"-!1 "!Before returning any item for service, an R.M.A. (Returned Material Authorization) number must be assigned by VCom.  A unique R.M.A. number will be assigned for each item being returned.  When requesting an R.M.A. number, please be prepared to provide the model, VCom serial number, original invoice number, your purchase order number and an adequate fault description.  The serial number of a unit can be found on a barcode label similar to the one pictured below.  R.M.A. service is available Monday to Friday from 8:30 a.m. to 4:30 p.m. CST (statutory holidays excepted).  To obtain an R.M.A. number you may:   Call: (306) 955-7075, press ‘0’ for Operator, or ‘3’ for Service Dept. Fax: (306) 384-0086 — Attention: R.M.A. Request Email: support@vcom.com  Once an R.M.A. number has been assigned, please refer to it in all correspondence and make certain that all applicable R.M.A. numbers are clearly marked on the outside of each package being returned.  You must also ensure that each product is shipped to VCom in its original shipping container (or equivalent) via Prepaid carrier, with appropriate insurance and customs documentation (where required).  VCom will not accept collect shipments, damaged shipments or shipments unaccompanied by an R.M.A. number.  For items still under Warranty – Items will be returned from VCom Inc. to its customer via prepaid ground carrier.  The customer is responsible for any additional costs incurred, including custom clearance and duties.  Any alternate means of shipment must be requested by the customer and will be subject to additional charges.   For items no longer under Warranty – Items will be returned from VCom Inc. to its customer via prepaid ground carrier at the customer’s expense.  The customer is responsible for any additional costs incurred, including custom clearance and duties.  Any alternate means of shipment must be requested by the customer and will be subject to additional charges.  Shipping Instructions will be provided by the repair center when the RMA number is sent to the customer.
   VCom Inc. PA700 Manual; ml_pa700_03 (January 2005) Approved: C.H. 17 3,'%/60#7Items returned beyond the warranty period or items that do not qualify for warranty service are subject to additional out-of-warranty repair charges.  Descriptions of these charges and warranty exemptions are below: 1) Repair turnaround time is typically 5-14 business days after receipt of the item at VCom. A Flat Rate Repair Charge will apply to all out-of-warranty items.  Flat Rate Repair Charges are subject to change without notice. 2) Any faults due to customer error (ie - incorrect set-up or configuration settings) are subject to the current  Test Fee and will be exempt from warranty. 3) Items returned with inadequate fault descriptions are subject to the current Test Fee and are  exempt from warranty. 4) In the event that no fault is found, the item is subject to the current Test Fee and will be  exempt from warranty. 5) Any product exhibiting external damage (either from shipping, improper handling or use) will be subject to inspection. If said damages are determined to be the cause of failure, the item will be exempt from warranty. All repairs to correct the external damage are subject to Time & Materials Charges (parts and labor at current rates). 6) Items with damage caused by unauthorized repairs or by external devices are subject to current out-of-warranty Flat Rate Repair Charges and are exempt from warranty. 7) All products returned for Factory Optioning are subject to the applicable current Option Charge plus Test Fee.  Factory-optioned products carry the balance of the original warranty or a 90-day warranty, whichever is greater. All out-of-warranty repairs must be approved by the customer in writing.  No repairs will be made until the customer’s Purchase Order or Out-Of-Warranty Repair Authorization is received.
                                        150 Cardinal Place Saskatoon, Saskatchewan S7L 6H7 Canada Tel: (306) 955-7075 Fax: (306) 955-9919 www.vcom.com sales@vcom.com

Navigation menu