Vecima Networks TR850 850 MHz Subscriber Transceiver User Manual ml tr850 01

Vecima Networks Inc. 850 MHz Subscriber Transceiver ml tr850 01

Users Manual

Download: Vecima Networks TR850 850 MHz Subscriber Transceiver User Manual ml tr850 01
Mirror Download [FCC.gov]Vecima Networks TR850 850 MHz Subscriber Transceiver User Manual ml tr850 01
Document ID558777
Application IDcpj3H8qfFW2upnGJLInp6w==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize80.61kB (1007651 bits)
Date Submitted2005-07-05 00:00:00
Date Available2005-07-02 00:00:00
Creation Date2005-01-21 11:34:55
Producing SoftwareAFPL Ghostscript 8.0
Document Lastmod2005-01-24 09:56:07
Document TitleMicrosoft Word - ml_tr850_01.doc
Document CreatorPScript5.dll Version 5.2
Document Author: colinho

AMPS Band
Transceiver
TR850
INSTALLATION AND OPERATION GUIDE
FOR SYSTEM OPERATORS
Proprietary to VCom Inc.
All rights reserved.
No part of this publication may by reproduced in any form or by any means or used to make any derivative work (such as translation,
transformation or adaptation) without written permission from VCom Inc.
VCom Inc. reserves the right to revise this publication and to make changes in content from time to time without obligation on the part of
VCom Inc. to provide notification of such revision or change.
VCom Inc. provides this guide without warranty of any kind, either implied or expressed, including, but not limited to, the implied warranties
of merchantability and fitness for a particular purpose. VCom Inc. may make improvements or changes in the product(s) described in
this manual at any time.
TR850 Manual; ml_850_01 (January 2005); Approved: C.H.
Specifications subject to change without notice — Printed in Canada
VCom Inc.
TR850 Manual; ml_tr850_01 (January 2005)
Approved: C.H.
ii
Thank-you for purchasing this product
and welcome to VCom!
You have chosen an innovative solution from a leading
technology design center in the ongoing TV & data delivery
revolution.
No doubt you’ve been thinking that the future of your television delivery system includes new technologies
such as Digital TV, Internet Over Cable, Wireless Cable. By selecting VCom, you are benefiting from the
same design powerhouse that since 1988 has created custom RF and digital products for technology leaders
such as AT&T, Cisco Systems, Cogeco, Comcast, and Cox Communications.
VCom designs and manufactures:
Agile CATV Modulators
256 QAM Upconverters
Digital Video Modulators
Frequency Translators
Spread Spectrum Devices
Off-Air Demodulators
Video-On-Demand Products
Wireless Cable MMDS
Wireless Cable LMDS
Frequency Stackers
MMDS Transceivers
Satellite Receivers
and more! Designs to fill the market needs of the CATV industry – both foreign and domestic.
For additional product or corporate information, contact us:
On the web at:
By sending email to:
By telephone:
By fax:
By snail mail:
www.vcom.com
sales@vcom.com
(306) 955-7075
(306) 955-9919
VCom Inc.
150 Cardinal Place
Saskatoon, SK Canada S7L 6H7
VCom's Corporate Mandate
is to be a leading worldwide designer and manufacturer of stateof-the-art communications equipment and components. Through
the remarkable success of our customers and business partners,
VCom innovations are achieving this goal.
VCom Inc.
TR850 Manual; ml_tr850_01 (January 2005)
Approved: C.H.
iii
SAFETY PRECAUTIONS
1. Before installing and operating this equipment, read all Safety, Installation and Operating sections. Retain
this manual for future reference.
2. Follow all instructions — Failure to do so may result in damage to the unit or severe personal injury.
3. Servicing should not be attempted by the user. There are no user serviceable parts inside. Refer all
servicing to factory qualified personnel.
4. Shock Hazard — An electrical shock hazard exists when the chassis cover is removed as is required to set
internal controls. Always disconnect power from the unit before removing the cover.
5. Cleaning — Do not use liquid or aerosol cleaners. Use a damp cloth for cleaning.
Warning Do not work on the system or connect or disconnect cables during periods of lightning activity.
CAUTION: To comply with FCC RF exposure requirements in section 1.1307, a minimum separation
distance of 1.5 meters is required between this antenna and all persons.
LES PRÉCAUTIONS DE SÉCURITÉ
1. Avant d'installer ou d'opérer cet équipement, lisez, toutes les sections de sécurités, d'installations et
d'opérations. Gardez ce manuel comme source de référence.
2. Suivez toutes instructions - si non, vous risquez d'endommager la machine ou de vous blesser
sérieusement.
3. N'essayez, pas de réparer cet équipement vous même. Référez toutes revisions nécessaire au personnel
qualifié de la manufacture.
4. Risque de choc - Il y a un risque de décharge électrique qui existe quand la couverture du châssis est
enlevée, comme est nécessaire pour ajuster les contrôlcs internes. Il faut toujours couper l'électricité avant
d'enlever le couvercle pour faire aucun ajustage.
5. Le nettoyage - n'utilisez pas de nettoyeurs aérosols ou liquides. Utilisez un tissu humide pour nettoyer.
Attention Ne pas travailler sur le système ni brancher ou débrancher les câbles pendant un orage du
foudre.
☛
Important Installation Instructions
CAUTION: To comply with FCC RF exposure requirements in section
1.1307, a minimum separation distance of 1.5 meters is required between
this antenna and all persons.
VCom Inc.
TR850 Manual; ml_tr850_01 (January 2005)
Approved: C.H.
iv
INDEX
1.0 GENERAL INFORMATION ......................................................................................................... 6
1.1 Functional Overview................................................................................................................................6
1.2 Module Features.......................................................................................................................................6
1.3 Specifications ............................................................................................................................................7
2.0 INSTALLATION............................................................................................................................ 8
2.1 Unpacking the Unit ..................................................................................................................................8
2.2 Mounting the Unit....................................................................................................................................8
2.2.1 Mounting the TR850........................................................................................................................................... 8
2.2.2 Mounting the Antenna......................................................................................................................................... 9
2.3 Connection to the Antenna....................................................................................................................10
2.4 Connection to the Power Inserter and Cable Modem.........................................................................11
2.5 Waterproofing Connections ..................................................................................................................13
3.0 WARRANTY STATEMENT AND SERVICE POLICY ............................................................ 15
3.1 Warranty Statement ..............................................................................................................................15
3.2 Service Policies: How to Return an Item for Service:.........................................................................15
3.3 Repair Charges and Warranty Exemptions ........................................................................................16
VCom Inc.
TR850 Manual; ml_tr850_01 (January 2005)
Approved: C.H.
The VCom TR850 is an AMPS Band Transceiver for use in wireless systems. The TR850 integrates an LNA,
upconverter, power amplifier, RF and IF diplexers to provide a one-box solution for two-way wireless RF
communications. The TR850 and antenna are situated outdoors and connected to a cable modem indoors by
standard RG-59 cable. A single RF connector on the weatherproofed enclosure provides the interface to the
transmit/receive antenna for rapid setup. The Transceiver is configured to work with standard cable modem
frequency plans and levels, permitting direct connection. The Transceiver also includes an RF mute function
to reduce power consumption and broadband noise emissions.
•
•
•
•
+24 dBm output for high reverse channel system gain
Low Phase Noise
Automatic transmit RF mute (transmits only when an IF signal is present)
Fully weatherized unit, suitable for outdoor mounting
VCom Inc.
TR850 Manual; ml_tr850_01 (January 2005)
Approved: C.H.
!
TRANSMITTER SPECIFICATIONS
IF Input Frequency
RF Output Frequency
Linear Output Power
Output P1dB
Spectral Mask
Gain
Gain Flatness (Frequency Response)
Gain Stability over Temperature
Phase Noise
Spectral inversion
IF Level for RF Activation
RF Activation/Mute Response Time
17-42 MHz
824-849 MHz
+24 dBm at RF port
+27 dBm at RF port
FCC CFR 47 Part 22.917
20 ± 2 dB at 23°C
± 1.0 dB in any 3MHz band
± 2.0 dB over -40°C to +60°C ambient
-87 dBc/Hz @ 10 kHz
No spectral inversion
-46 ± 3 dBm maximum
<2 microseconds max
RECEIVER SPECIFICATIONS
Frequency
Gain
Gain Flatness (Frequency Response)
Noise Figure
869-894 MHz
24 ± 2 dB at 23°C
± 1.0 dB in any 6MHz band
<5 dB typical, 6.0 dB maximum
GENERAL
Frequency Stability
Frequency Stability over time
RF Connector
IF Connector
DC Supply
Operating Ambient Temperature
Size
Weight
Mounting
± 20 kHz (-30 to +60°C)
< ±35 kHz over 10 years
N female, 50 ohms
F female, 75 ohms
+10 to 28 V (+24V nominal), +10W
-40°C to +60°C
5" x 7" x 1" (12.7cm x 17.8cm x 2.5cm)
2.2 lbs. (1 kg)
Pole mount, 1” to 1.75” diameter pole
RF PORT SPECIFICATIONS
RF Return Loss
RF Spurious Emissions
Better than 8 dB in transmit and receive RF bands
FCC CFR 47 Part 22.917
IF PORT SPECIFICATIONS
IF Return Loss
IF Spurious Emissions
Better than 10 dB over transmit and receive IF bands
-30 dBm from 100-860 MHz except receiver frequency range
-80 dBm, receiver frequency range
Specifications subject to change without notice.
VCom Inc.
TR850 Manual; ml_tr850_01 (January 2005)
Approved: C.H.
# !
$ % & #
Carefully remove the equipment from its packing material and set it on a solid surface, such as a table or
desk. If it appears damaged in any way, notify the carrier, and keep all packing materials for inspection by the
carrier’s agent.
% & #
% &
'(
The following hardware is included in the box for mounting the TR850 to the pole:
•
•
1 V-bolt
2 ¼”x20 flange locknuts for connecting V-bolt and pole catch to the pole
The TR850 was designed for mounting to a pole with a diameter of 1.0" to 1.75". Please ensure that the
pole used is attached securely to the building or other mounting location. Simply secure the TR850 unit to a
pole as shown in Figure 2.2A with F-Connectors on the bottom.
DIAGRAM 2.2A: MOUNTING THE UNIT
Top View of TR850
Mounted to the Pole
VCom Inc.
TR850 Manual; ml_tr850_01 (January 2005)
Approved: C.H.
% &
Mount the antenna according to the manufacturer’s instructions.
The TR850 is intended for use with planar arrays and Yagi antennas. Please consult table 2.2B
for further information.
TABLE 2.2B: ANTENNA LIST
Transceiver Power
[Watts]
0.25
0.25
0.25
[dBm]
+24
+24
+24
Antenna Type
Antenna Gain
Yagi
Flat planar array
Window mount planar array
[dBi]
10 dBi
9 dBi
7 dBi
Included with the TR850 unit is a self-adhesive label for application to the antenna. To operate
the TR850 in compliance with FCC regulations, you must apply the included label to the antenna.
Peel off the protective backing from the label and affix it to the antenna such that the label is
readable from a distance of 5 feet.
DIAGRAM 2.2C: APPLYING THE SELF-ADHESIVE LABEL
VCom Inc.
TR850 Manual; ml_tr850_01 (January 2005)
Approved: C.H.
)
Connect the TR850 to the Antenna via the F-Connector
DIAGRAM 2.3A: CONNECTION TO THE ANTENNA
VCom Inc.
TR850 Manual; ml_tr850_01 (January 2005)
Approved: C.H.
10
*)
& +
) ,
Connections to the TR850 are made as shown in Diagrams 2.3A and either 2.4B or 2.4C depending on which
power supply and inserter came with the TR850.
The power inserter has three connections:
DC POWER
Connect to wall adapter with RG-59 cable with F connectors
TO MODEM
Connect to cable modem
TO TRANSCEIVER
Connect to TR850
WARNING!
If the power inserter is not connected correctly, the TR850 will not operate,
and there is the potential to damage the cable modem.
Ensure that all wires and cables are hooked up before plugging into the
AC adapter/power supply (i.e. hook up to the power supply last).
After connection, both connectors MUST be waterproofed with the supplied rubber sealing tape. See Section 2.5
for details.
DIAGRAM 2.4A: CONNECTION TO CABLE MODEM VIA POWER INSERTER USING PS24V750MA-01
VCom Inc.
TR850 Manual; ml_tr850_01 (January 2005)
Approved: C.H.
11
DIAGRAM 2.4B: CONNECTION TO CABLE MODEM VIA POWER INSERTER USING CPE POWER SUPPLY & INSERTER
VCom Inc.
TR850 Manual; ml_tr850_01 (January 2005)
Approved: C.H.
12
(.
" %)
Many transceiver problems can be attributed to environmental conditions (including vibration), which can
loosen cables and permit moisture to penetrate the connectors. It is highly recommended to seal the
connectors using a technique similar to the one described below. This will provide moisture protection and
keep the connections tight. For your convenience, VCom has provided two 6 inch lengths of rubber selfamalgamating sealing tape to use on the two connections of the TR850.
STEP 1
Use one 6” section of rubber sealing tape. Starting at the TR850 end, stretch the tape and wrap it around the
connector as close as possible to the wall of the TR850. Overlap the tape by approximately one-half of it’s
width so that it can form a seal with itself. Extend the wrapping to approximately one inch past the end of the
connector.
DIAGRAM 2.5A: WATERPROOFING CONNECTION – STEP 1
STEP 2
Cover the sealing tape with electrical tape (not provided). Start approximately one inch further down the
cable, and stretch the tape, overlapping by one-half. Wrap to the TR850 end and without breaking the tape,
wrap back down to the cable end.
DIAGRAM 2.5B: WATEPROOFING CONNECTION – STEP 2
VCom Inc.
TR850 Manual; ml_tr850_01 (January 2005)
Approved: C.H.
13
STEP 3
When done, the connection should be tightly wrapped with tape, with a good seal to the cable.
DIAGRAM 2.5C: WATERPROOFING CONNECTION – STEP 3
VCom Inc.
TR850 Manual; ml_tr850_01 (January 2005)
Approved: C.H.
14
.
1 ) +
)/
VCom warrants its products to be free from defects in workmanship or materials for a period of two years.
The warranty begins on the date of the original shipment from VCom to its customer. No claim may be
allowed for expenses incurred in installation or use. No other expressed or implied warranties shall apply to
the goods sold. VCom is not responsible for delayed shipments, other loss beyond VCom’s control, or
consequential damages of any kind arising in connection with the use of its products. This warranty is a
return-to-factory warranty only. During the warranty period VCom will at its option, replace, repair or refund
the price paid for any item which is returned for service. This warranty does not apply to units that have been
physically or environmentally abused.
34
-"
Before returning any item for service, an R.M.A. (Returned Material Authorization) number must be assigned
by VCom. A unique R.M.A. number will be assigned for each item being returned. When requesting an
R.M.A. number, please be prepared to provide the model, VCom serial number, original invoice number, your
purchase order number and an adequate fault description. The serial number of a unit can be found on a
barcode label similar to the one pictured below. R.M.A. service is available Monday to Friday from 8:30 a.m.
to 4:30 p.m. CST (statutory holidays excepted).
To obtain an R.M.A. number you may:
Call: (306) 955-7075, press ‘0’ for Operator, or ‘3’ for Service Dept.
Fax: (306) 384-0086 — Attention: R.M.A. Request
Email: support@vcom.com
Once an R.M.A. number has been assigned, please refer to it in all correspondence and make certain that all
applicable R.M.A. numbers are clearly marked on the outside of each package being returned. You must also
ensure that each product is shipped to VCom in its original shipping container (or equivalent) via Prepaid
carrier, with appropriate insurance and customs documentation (where required). VCom will not accept
collect shipments, damaged shipments or shipments unaccompanied by an R.M.A. number.
For items still under Warranty – Items will be returned from VCom Inc. to its customer via prepaid ground
carrier. The customer is responsible for any additional costs incurred, including custom clearance and duties.
Any alternate means of shipment must be requested by the customer and will be subject to additional
charges.
For items no longer under Warranty – Items will be returned from VCom Inc. to its customer via prepaid
ground carrier at the customer’s expense. The customer is responsible for any additional costs incurred,
including custom clearance and duties. Any alternate means of shipment must be requested by the customer
and will be subject to additional charges.
Shipping Instructions will be provided by the repair center when the RMA number is sent to the
customer.
VCom Inc.
TR850 Manual; ml_tr850_01 (January 2005)
Approved: C.H.
15
!
)&
2 5 -!
Items returned beyond the warranty period or items that do not qualify for warranty service are subject to
additional out-of-warranty repair charges. Descriptions of these charges and warranty exemptions are below:
1) Repair turnaround time is typically 5-14 business days after receipt of the item at VCom. A Flat Rate Repair
Charge will apply to all out-of-warranty items. Flat Rate Repair Charges are subject to change without
notice.
2) Any faults due to customer error (ie - incorrect set-up or configuration settings) are subject to the current
Test Fee and will be exempt from warranty.
3) Items returned with inadequate fault descriptions are subject to the current Test Fee and are
exempt from warranty.
4) In the event that no fault is found, the item is subject to the current Test Fee and will be
exempt from warranty.
5) Any product exhibiting external damage (either from shipping, improper handling or use) will be subject to
inspection. If said damages are determined to be the cause of failure, the item will be exempt from
warranty.
All repairs to correct the external damage are subject to Time & Materials Charges (parts and labor at
current rates).
6) Items with damage caused by unauthorized repairs or by external devices are subject to current out-ofwarranty Flat Rate Repair Charges and are exempt from warranty.
7) All products returned for Factory Optioning are subject to the applicable current Option Charge plus Test
Fee. Factory-optioned products carry the balance of the original warranty or a 90 day warranty, whichever
is greater.
All out-of-warranty repairs must be approved by the customer in writing. No repairs will be made until the
customer’s Purchase Order or Out-Of-Warranty Repair Authorization is received.
VCom Inc.
TR850 Manual; ml_tr850_01 (January 2005)
Approved: C.H.
16
150 Cardinal Place
Saskatoon, Saskatchewan
S7L 6H7
Canada
Tel: (306) 955-7075
Fax: (306) 955-9919
www.vcom.com
sales@vcom.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Producer                        : AFPL Ghostscript 8.0
Create Date                     : 2005:01:21 11:34:55
Modify Date                     : 2005:01:24 09:56:07-06:00
Title                           : Microsoft Word - ml_tr850_01.doc
Creator                         : PScript5.dll Version 5.2
Author                          : colinho
Page Count                      : 18
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OPPTR850

Navigation menu