 REVISION HISTORY  Rev Description Date Apprv’d  000  Initial Release per ECO 127519  Ref. PLM  001  Update after customer review  Ref. PLM  002  Update 5.3.1, add 5.3.8  Ref. PLM  003  Update 5.3.1 RX Distance  Ref. PLM                                            TITLE:  Installation Specifications and User Manual, C6 Radar (24 GHz MMR, 24 GHz SRR, 24 GHz MRR)  DOCUMENT NO:  E805913 INSTALLATION SPECIFICATION  REV. 003,  PAGE 1 OF 12  AEL, Inc. 1011B Pawtucket Blvd. Lowell, MA  01853 ATTENTION USER OF THIS DOCUMENT IS RESPONSIBLE FOR DETERMINING CURRENT REVISION LEVEL BEFORE USING DOCUMENT. ©AUTOLIV INC. THIS DOCUMENT AND THE DATA DISCLOSED HEREIN OR HEREWITH IS PROPRIETARY AND MAY NOT BE REPRODUCED, USED OR DISCLOSED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION FROM AUTOLIV INC.
Title Installation Specifications and User Manual, Radar Sensor, C6  Doc. No.  E805913 INSTALLATION SPECIFICATION  Rev. 003,  Page 2 of 12    1.0  PURPOSE/SCOPE  This document describes the specifications for installation of type C6 Radar Sensors.  2.0  MATERIALS/EQUIPMENT  N/A  3.0  APPLICABLE DOCUMENTS  Outline see Fig 1. DIN 40050-9 IP6K9K IEC 68-2-6 Fc    IEC 68-2-7  IEC68-2-10     IEC68-2-11 Ka IEC 668-2-14Nb  IEC 68-2-27  IEC 68-2-29     IEC68-2-30 IEC68-2-32     IEC68-2-38  IEC68-2-50     IEC68-2-51 IEC68-2-52    IEC68-2-56   IEC68-2-64Fh   IEC529, 13.4 SAE J1211    SAE J1812  SAE J1879  4.0  DEFINITIONS  N/A  5.0  SPECIFICATIONS  5.1.  Preface  This chapter describes the specifications to install C6 radar sensors into vehicles.  These specifications shall be complied with to enable the specified characteristics of the sensors as well as the complete system.  Due to the various installation situations and applications, a measurement check is required to verify the actual installation implementation.  5.2.  C6 Sensors  This chapter describes the characteristics relevant to the installation of C6 sensors in vehicles.  Note that there are three types of C6 sensors, each supporting various applications as follows: C6 Mid Range Radar (24 GHz MRR) Model # 6208428  – used for medium range applications such as Forward collision Warning. C6 Short Range Radar (24 GHz SRR) Model # 6221569  – used for short range applications such as ACC Stop and Go, Blind Spot Monitoring. C6 Multi Mode sensor (24 GHz MMR) Model # 6234448  – combined SRR and MRR functionality.  Unless otherwise stated the specifications contained in this document apply to all C6 sensor types.
Title Installation Specifications and User Manual, Radar Sensor, C6  Doc. No.  E805913 INSTALLATION SPECIFICATION  Rev. 003,  Page 3 of 12    5.2.1.  Dimensions and Weight of the C6 Sensor  Figure 1 shows the dimensions of the C6 sensor and details the mounting of the sensor.  Please refer to Fig. 1 for the detailed drawing.  Sensor weight:  150 grams max.
Title: Installation Specifications and User Manual, Radar Sensor, C6  Doc. No.  E805913 INSTALLATION SPECIFICATION  Rev. 003,  Page 4 of 12   5.0  SPECIFICATIONS  Figure 1 IMPORTANT NOTE: The two mounting holes are not specified for mounting the complete sensor. They do not provide the mechanical properties to keep the sensor in place.  They shall be used to fix the sensor in a mounting bracket. Mounting tabs are to be fastened tight to mounting bracket using appropriate fastener. Maximum strength per tab is 270 N.
Title: Installation Specifications and User Manual, Radar Sensor, C6  Doc. No.  E805913 INSTALLATION SPECIFICATION  Rev. 003,  Page 5 of 12   5.0  SPECIFICATIONS  5.2  C6 Sensor (cont’d)  5.2.2  Keep-Out Zone / Azimuth Angle Measurement Range  Figure 2 displays the keep out area of the C6 sensor.   Within the detection area of the antennas there must not be objects like screws, mounting brackets, license plates etc.  The impact reducing foam material, clips or fascia laminations has to be avoided in that area.  Within the keep out zone of the antennas  there must be no vertical character lines present in the fascia (see 5.3.5). Mounting bracket material shall not enter the keep out zone. Bracket retention features which interface with the surface of the sensor radome shall not enter the keep out zone noted in Section 5.2.5    The keep out zone in the azimuth direction is ±65°.   The angle is established 7mm from the edge of the sensor.        Figure 2
Title: Installation Specifications and User Manual, Radar Sensor, C6  Doc. No.  E805913 INSTALLATION SPECIFICATION  Rev. 003,  Page 6 of 12   5.0  SPECIFICATIONS  5.2  C6 Sensor (cont’d)  5.2.3  Keep-out zone, Angle Elevation  Within the elevation keep out zone there must not be metal parts like screws, mounting brackets, license plate etc. The impact reducing foam material, clips or fascia laminations has to be avoided in that area.   Within the keep out zone of the antennas there must be no vertical character lines present in the fascia (see 5.3.5). Mounting bracket material shall not enter the keep out zone.  Bracket retention features which interface with the surface of the sensor radome shall not enter the keep out zone noted in Section 5.2.5     The elevation material keep out zone in elevation is ±30°. This angle is established 7mm from the edge of the sensor.     Figure 3
Title: Installation Specifications and User Manual, Radar Sensor, C6  Doc. No.  E805913 INSTALLATION SPECIFICATION  Rev. 003,  Page 7 of 12   5.2  C6 Sensor (cont’d) 5.2.4  Section deleted    5.2.5  Bracket to sensor retention features keep out zone  Bracket retention features which are used to hold the sensor into the bracket, shall be made of non-conductive material, and protrude into the face of the sensor radome with enough overlap to overcome any variability in the bracket (ie. bracket to sensor gap, material distortion). A general guideline is to create a retention feature with overlap which is positioned in the allowable shaded area outlined below (Figure 3b).     Figure 3b
Title: Installation Specifications and User Manual, Radar Sensor, C6  Doc. No.  E805913 INSTALLATION SPECIFICATION  Rev. 003,  Page 8 of 12    5.3  Installation Specifications for Individual Sensors  5.3.1  Distance to the Bumper Material  The distance of the C6 Sensor to the bumper shall be as shown below. An installation with the sensor parallel to fascia is preferred. If this is not possible any combination of TX and RX distance within the table below are allowed.  Figure 4   Sensor Model#  Sensor Type    RX Distance    TX Distance   6208428    Mid Range Radar  5mm-25mm    5mm-25mm   6221569    Short Range Radar  5mm-25mm    5mm-25mm   6234448    Multimode Sensor  5mm-25mm    5mm-25mm           5.3.2  Section Deleted
Title: Installation Specifications and User Manual, Radar Sensor, C6  Doc. No.  E805913 INSTALLATION SPECIFICATION  Rev. 003,  Page 9 of 12   5.0  SPECIFICATIONS  5.3  Installation Specifications for Individual Sensors (cont’d)  5.3.3  Effect of Type- and Thickness of Fascia Material  Autoliv has examined various fascia material samples with a thickness of 2.5 – 4 mm.  Fascia loss effects can be optimized by proper control of the material thickness and dielectric constant. Thickness should be uniform in front of the radar sensor.  Thickness and dielectric constant must be controlled to a tolerance of ±10% max to ensure optimal performance.  New fascia material shall be evaluated by Autoliv for its characteristics at RF antenna frequency.  5.3.4  Effect of the Paint  Effect of paint is detailed in Appendix A.  New paint material shall be evaluated by Autoliv.  5.3.5  Smoothness of Fascia in Front of Antenna  Avoid sharp vertical or near vertical character lines in front of sensor antenna.  Horizontal character lines seem to have little effect on sensor performance.  Fascias with textured surfaces shall be evaluated by Autoliv to characterize the effects on sensor performance.       Figure 6
Title: Installation Specifications and User Manual, Radar Sensor, C6  Doc. No.  E805913 INSTALLATION SPECIFICATION  Rev. 003,  Page 10 of 12   5.0  SPECIFICATIONS  5.3  Installation Specifications For Individual Sensors (cont’d)  5.3.6  Protection from Mud and Dirt Buildup  There will be performance degradation if excessive buildup occurs on the antenna areas and especially for wet mud. Therefore Autoliv strongly recommends the sensor mounting include provisions to protect the antenna face from dirt and mud accumulation. The mounting concept should completely protect the face of the antenna to prevent mud and dirt from entering the free space between the sensor radome and the fascia, yet a small weep hole at the bottom of the bracket is required to allow condensation to dissipate.      5.3.7  Sensor Mounting Thermal Considerations   The sensor is specified to operate in a –40° to +85°C ambient, still air environment. Natural convection and venting from the front and backside surfaces of the sensor to the ambient air is assumed. Therefore the mounting concept shall leave both the front radome and backside area of the sensor exposed to the ambient air. Minimum area to be left for the backside exposed is as shown below. Bracket reinforced structure such as cross bars are allowed if approximately 80% of backside area remains exposed to ambient air for heat dissipation.  Maximum surface temperature in this region is +115°C at a maximum ambient of +85°C.      Figure 7
Title: Installation Specifications and User Manual, Radar Sensor, C6  Doc. No.  E805913 INSTALLATION SPECIFICATION  Rev. 003,  Page 11 of 12   5.3.8  Mounting Bracket Design and Vehicle Mounting     In addition to the mounting bracket design being consistent with the keep out zones described in this document the bracket must also provide the following:     - The mounting bracket shall prevent sensor movement or vibration in x, y, or z direction with respect to the bracket.     - The bracket shall be mounted to vehicle in manner to prevent sensor movement or vibration  in  x, y, or z direction with respect to the fascia surface that is in the sensor field view (sensor keep out zone). To achieve this it is preferred that the bracket be firmly attached to the inner surface of the fascia.      - For cases where a chassis mounted bracket is only option there shall be design considerations in place to prevent movement or vibration in x, y, or z direction with respect to the fascia surface that is in the sensor field view (sensor keep out zone).   6.0  C6 SENSOR SYSTEM  The following observations refer to the combination of several C6 Sensors into one sensor system. Many applications require several sensors networked together to achieve the desired function. The sensors should be placed in the best possible location for optimal coverage and range performance   relative to the specific applications. The optimal locations will be highly dependent on the desired applications and the bumper dimensions. Autoliv can perform analysis and characterization to determine sensor locations to best achieve a desired performance.  Attention should be paid that the installation specifications for individual sensors from chapter 5 are maintained. Due to the various installation situations and applications, a measurement check is required to verify the actual installation implementation.
Title: Installation Specifications and User Manual, Radar Sensor, C6  Doc. No.  E805913 INSTALLATION SPECIFICATION  Rev. 003,  Page 12 of 12     APPENDIX A   EFFECT OF PAINT  Depending upon the type of paint, number of coatings, base coats used, etc. the attenuation of the radar signal was measured between 2 and 5 dB (corresponds to reduction of coverage between 11 and 25%).  Because attenuation has significant impact on performance, prior inspection of the material and paint samples are suggested.  Autoliv can characterize painted fascia samples to determine the radar signal loss effects. Autoliv sensor specifications assume a maximum signal loss (2-way) of 4 dB due to fascia effects. Materials and paints that exhibit greater than 4 dB loss will degrade the specified performance. As noted in 5.3.3 performance can be optimized by proper control of the fascia material thickness and dielectric constant.