SleepO2
TM
Sleep Oxygen Monitor
User Manual
This product is intended only for general wellness use. It is not a medical
device and should not be used to diagnose or treat any medical
condition.
1.2
After fully charged, the device will power off
automatically.
2.3
POWER ON/OFF
POWER ON:
Press the button on the side for 1 second to turn on
the device.
Unpacking
Main Unit × 1
Charging Cable × 1
User Manual × 1
1.3
Overview
Wear the device during sleep. It protects you
from oxygen shortage by Smart Vibration.
Manually: press the button for about 2 seconds to
turn off.
1. Introduction
1.1

Warnings and Cautions
DO NOT squeeze the sensor part or apply excessive force
on it.
Oxygen drop
Smart Vibration
Oxygen recover
Next morning, you can get the sleep results and
O2 Score in App to help you track.
You can customize Smart Vibration in App to
help you sleep better.







Do not use this device during MRI examination.
Never submerge the device in water or other liquids. Do not
clean the device with acetone or other volatile solutions.
Do not place this device in pressure vessels or gas
sterilization device.
Consult your doctor immediately if you experience
symptoms that could indicate acute disease.
Do not self-diagnose or self-medicate on the basis of this
device without consulting your doctor. In particular, do not
start taking any new medication or change the type and/or
dosage of any existing medication without prior approval.
Use only cables, sensors and other accessories specified in
this manual.
Prolonged continuous monitoring may increase the risk of
undesirable changes in skin characteristics, such as irritation,
reddening, blistering or burns.
POWER OFF:
Recommended way: device turns off automatically
in 2 minutes if no measurement, no operation,
without App connection.
Using the Monitor
2.1
Download App
App name: Check O2
iOS: App Store
Android: Google Play
2.2
Charging
Charge the battery before using.
Connect the device to USB of computer or USB
charging adapter.
2.4
Typical steps
2.5
1)
2)
Start monitoring
Wear the device on the
forefinger. If it is too tight,
try another finger.
Turn on the device. After a
few seconds, the device will begin to monitor.
(If the working time is less than 1 minute, the
data will not be saved)
Note:
•
2.6
Please avoid excessive motion for the sensed finger during
recording and avoid any strong ambient light condition.
Stop monitoring & sync data
START. Charge the battery.
Wear the device, press the
button to power on. Go to sleep.
Take off the device, the countdown
will begin.
(If the working time is less than 1 minute, there will
be no countdown)
STOP. Next morning, take off the
device, the recording will be over
after the countdown.
During the countdown, if you wear the device again,
the record will be resumed.
After the countdown, the data will be ready for
sync.
DATA
SYNC.
After
the
countdown, run App to sync
data. Check results in App.
Sync data:
1) After the countdown, run App to sync data;
2) Or next time after you turn on the device, run
App to sync.
Note: The device can store maximum 4 records.
The oldest record will be overwritten when the 5th
record is coming in. Please sync data to your phone
in time.
2.7
Display
18:45
SPO2
O2 7.5
13
Time, Remaining battery capacity
Blood oxygen saturation
Heart rate
Wear the device
O2 Score, SpO2 drop times
You can customize the vibration to help you sleep
better. Make sure your device is connected to App
first. Then you can configure it in App->Device.
•
•
•
During measurement, press the button, you can
switch different displays.
2.8
Bluetooth Connection
The device Bluetooth will be enabled automatically
only when the screen lights up.
To establish a Bluetooth connection,
1) Ensure the device screen is on to keep the
device Bluetooth enabled.
2) Make sure the phone Bluetooth is enabled.
3) Run the App, then select the Device ID for the
initial use.
You can switch on or off the vibration.
You can adjust the Intensity of vibration.
You can adjust the Threshold. If the vibration
disturbs you during sleep too much, you can
lower the Threshold. If you would like to get
more protection from oxygen shortage, you
can turn up the Threshold.
View Results and Report
In App, you can review all
the history data. Touch a
record, there comes out the
detailed
report,
which
includes analysis results and
charts.
Slide a record to left, you can delete it.
2.9
Smart Vibration
The vibrator in the sensor will be activated when the
SpO2 fall below the pre-set value (Threshold). The
vibration will stop when the SpO2 recover, or you can
press the button to stop it.
O2 Score
Example:
O2 Score 7.5
10
Cleaning
Use a soft cloth moistened with water or alcohol to
clean the device surface.
3.2
1)
2)
O2 Score is overall assessment of oxygen condition,
which synthesizes the frequency, depth and
duration of oxygen shortage overnight. The range is
0-10 (10 is best). It is provided for each record in
App.
2.10
Maintenance
Firmware Update
Connect the monitor with the APP.
Enter the APP, visit Device  Device Update.
Check the version and start an update if you
want.
Battery
To keep the battery in good condition, charge the
battery every 6 months when the device is not in use.
2.12
You can check real-time SpO2, Heart Rate in App.
1) Connect device to App.
2) App->Dashboard.
3.1
3.3
2.11
Note: DO NOT PAIR in the settings of your
smartphone.
Real-time Dashboard
(in the APP)
Possible Cause
Device
does not
turn on
or no
response
Battery may be low.
Unexpected
software condition
Device might be
damaged.
The app
cannot
find the
device
The Bluetooth of
your phone is off.
The device
Bluetooth is off in
Sleep Mode.
Weight
Size
Battery
Charge time
Wireless
Oxygen level
range
Heart Rate range
Possible
Solution
Charge battery
and try again.
Press the button
for about 10
seconds to reset
Please contact
your local
distributor.
Turn on the
Bluetooth in the
phone.
Press the button,
the Bluetooth will
be turned on
when the screen
lights up.
18g
44×25×17 mm (main unit)
Rechargeable Lithium-polymer
2-3 hours
Bluetooth 4.0 BLE
70% to 100%
30 to 250 bpm
Trigged by low oxygen level
Oxygen Level, heart rate, motion
Vibration
Recorded
parameters
Data storage
Mobile App for iOS
Mobile App
android
Troubleshooting
Problem
Specifications
Model: Oxiband-1
Version: A
for
4 records, up to 10 hours for
each
iOS 9.0 or above,
iPhone 4s/iPad 3 or above
Android 4.4 or above,
with Bluetooth 4.0 BLE
FCC Statement
15.19
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause
undesired operation.
15.21
Note: The grantee is not responsible for any changes or modifications not expressly approved by
the party responsible for compliance. Such modifications could void the user’s authority to operate
the equipment.
15.105(b)
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-Consult the dealer or an experienced radio/TV technician for help

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Author                          : 王晓娟
Comments                        : 
Company                         : Microsoft
Create Date                     : 2018:06:28 17:24:04+08:00
Modify Date                     : 2018:08:16 13:51:10+08:00
Source Modified                 : D:20180628092231
Subject                         : 
Tagged PDF                      : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2018:08:16 13:51:10+08:00
Creator Tool                    : Acrobat PDFMaker 11 Word 版
Document ID                     : uuid:e0073dc2-20ca-40d9-8d3d-d81de1635ffa
Instance ID                     : uuid:6aac0e49-b488-44ee-8057-a7007c8a87b8
Format                          : application/pdf
Title                           : 
Description                     : 
Creator                         : 王晓娟
Producer                        : Adobe PDF Library 11.0
Keywords                        : 
Page Layout                     : OneColumn
Page Count                      : 3
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ADXK-1651

Navigation menu