Solar System Controls and Accessories

The SCU solar system control series offers
options for any type of system, from basic singleload installations to complex multi-load systems
with demanding requirements. With their large
LCD displays, SCU controls are user-friendly and
provide industry leading solar system safety,
performance and efficiency.
All controls incorporate variable speed pump
control, preprogrammed configurations, collector
glycol cooling function, heat rejection loop control,
energy meter and VBus accessories. The SCU
345 control also provides data logging to an
internal SD memory card, and an optional SEM
flow meter kit can be added for precise energy
metering or used as a standalone unit.

TopInfo

Solar System Controls and Accessories

SCU 124/SCU 224 solar system controls for
basic single- and multi-load systems
The SCU 124 and SCU 224 solar system
controls are ideal for basic systems with
two semiconductor relay outputs and four
sensor inputs. The single-load SCU 124
control features three basic, preprogrammed
system configurations for easy planning and
installation. For basic multi-load systems or
east-west collector arrays, the SCU 224 control
is an ideal choice. It features an additional

SCU 124/SCU 224 Solar System Control

delta-T for control of second relay, as well as
10 preprogrammed system configurations for
ultimate installation flexibility.

SD

w
Ne

With SD card capabilities*, the
SCU345 control allows you to

SCU 345 solar system control for multi-load,
east-west and commercial arrays
The SCU 345 is an advanced solar system
control for multi-load systems, east-west
collector arrays and commercial solar systems.
This advanced solar system control features
four relay outputs and adjustable delta-T
and time controlled thermostat functions for
limitless configuration possibilities. The SCU
345 control is compatible with a number of
system accessories designed for system
monitoring, analytics and additional control.

w
Ne

SCU 345 Solar System Control

view system data on your PC.
Adjustable logging intervals from
one second to 20 minutes.

Control Section Guide

w
Ne

V40 Flowmeter Kit includes two
sensors and two sensor wells.

SCU 124

SCU 224

SCU 345

Relay outputs

2

2

4

Variable speed pump







Sensor inputs

4

4

5

System configurations

3

10

9

Number of heat loads (tanks)

1

2

3

Number of differentials

1

2

3

Heat dissipater layout







Energy meter







Pump hour counter







Collector cooling







Night tank cooling







V-Bus accessories







Internal SD card

_

_



Flowmeter option

_

_



Model

For use with SCU 345 or SEM.

*Field supplied.

Sample System Layout — with optional accessories shown
s

4

7

1

s

6
2

4
8

M

5

9

5

10

3
s

4

11
s 4

s

4
12

Solar Energy Meter
With input from the V40 Flowmeter and two system
sensors, the Solar Energy Meter (SEM) records the
energy yield and flowrate produced by your solar
system. Heat quality calculations displayed on the
large screen are also stored in the internal memory
or transmitted to the Datalogger or PC using VBus
communication.

w
Ne

Solar Energy Meter

SCU Control Accessories

VBus/PWM Interface Adaptor allows for

Smart Display shows collector and tank

Datalogger stores 180 MB of operational

control of a high efficiency pump.

temperature and energy production in

details. SD card* or ethernet for data

real time.

extraction.

*Field supplied.

1

Vitosol solar collector

2

Solar-Divicon

3

V40 Flowmeter Kit

4

Temperature sensor

5

Vitocell solar tank

6

Motorized diverting valve

7

SCU 345 control

8

VBus/PWM Interface

9

Smart Display

10

Datalogger

11

Internet

12

PC

®

®

Viessmann Manufacturing
Company Inc.
Waterloo, ON Canada
1-800-387-7373
www.viessmann.ca
Viessmann Manufacturing
Company (U.S.) Inc.
Warwick, RI U.S.A.
1-800-288-0667
www.viessmann.us

V40 Flowmeter Technical Data

Flowmeter Pressure Loss Curve

Three Flowmeter Kit sizes available; flowmeter must be sized to
match flow rate of system.

V40-15

V40-25

Minimum flow rate

0.1
usgpm

0.3
usgpm

0.5
usgpm

Maximum practical
flow rate
recommended

2.4
usgpm

5.3
usgpm

9.7
usgpm

Maximum number
of Vitosol Flat Plate
Solar Collectors
Maximum number
of Vitosol Vacuum
Tube Solar Collectors
Pressure loss at
maximum
recommended
flow rate

Pressure loss in bar

V40-06

Flowmeter Model

V4

1

14

24

90

180

360

80“
w.c.

80“
w.c.

80“
w.c.

V4

0-

15
V4

0-

25
400
200

0.1

40

0.05

30

0.01

4
0.1

0.3

0.5

1

3

5

m³/h

0.44

1.3

2.2

4.4

13.2

22

usgpm

V40 Flowmeter Kit

Technical information subject to change without notice.
9440 428 v1.0 08/12 Printed in Canada

06

0.5

Flow rate

6

0-

Pressure loss " w.c.

Flowmeter Sizing



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : romj
Create Date                     : 2012:08:16 11:28:25-04:00
Modify Date                     : 2012:08:16 11:32:40-04:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2012:08:16 11:32:40-04:00
Format                          : application/pdf
Title                           : TopInfo Solar Controls.indd
Creator                         : romj
Document ID                     : uuid:74f8a6c9-b46c-4b68-8840-d3c6e9a9e070
Instance ID                     : uuid:91a1bab1-4912-4531-a01a-70b4880770ee
Page Count                      : 4
EXIF Metadata provided by EXIF.tools

Navigation menu