Viessmann Vitosol 100 F Technical Manual 5354 729 V1.3
2015-08-26
: Viessmann Viessmann-Vitosol-100-F-Technical-Manual-802326 viessmann-vitosol-100-f-technical-manual-802326 viessmann pdf
Open the PDF directly: View PDF
.
Page Count: 4
| Download | |
| Open PDF In Browser | View PDF |
VITOSOL 100-F Flat plate solar collectors for the harnessing of solar energy Panels with 25 ft.2 (2.32 m2) absorber surface Technical Data Manual Part Nos. and Pricing: see Price List VITOSOL 100-F Model SV1B and SH1B Flat plate solar collectors Certified in accordance with SRCC OG-100. for vertical or horizontal installation on sloped and flat roofs To produce domestic hot water, or to supplement low-temperature heating systems or swimming pools via a heat exchanger Listed by CSA International as complying with the Energy Efficiency Verification Service requirements 5354 729 v1.3 03/2011 Meets the requirements of the German “Blue Angel” certificate of environmental excellence to RAL UZ 73. Certified in accordance with Solar Keymark testing requirements. Product Information Vitosol 100-F Models SV1B, SH1B The benefits at a glance: H High performance flat plate collector at an attractive price, thanks to a highly-efficient selectively-coated copper absorber. H Suitable for many residential or commercial applications with vertical or horizontal versions available. Best suited for DHW or pool heating. H Rugged, high-quality construction using impact-resistant low-iron solar glass, copper piping and absorber, aluminum frame and non-degrading thermal insulation. H Permanently sealed and high stability through all-around folded aluminum frame and endless glass seal. H Fast installation with flexible connection pipes and quick-connect fittings. Prefabricated collector mounting hardware ensures easy connection to roofs. H Maximum system performance and reliability with a full range of solar system components designed to integrate seamlessly. H Certified to the Solar Rating and Certification Corporation (SRCC) OG-100 Standard. CSA Energy Efficiency Verification. H Quality tested to Solar Keymark testing requirements. Meets the requirements of the German “Blue Angel” certificate of environmental excellence. Solar glass cover, 0.13” (3.2 mm) thick Aluminum cover strip Continuous glass seal Copper absorber sheet Meander-shaped copper pipe 2 Construction and function The main component of the Vitosol 100-F is the black chrome coated copper absorber. It ensures high absorption of solar radiation and low emission of thermal radiation. A meander-shaped copper pipe, through which the heat transfer medium flows, is permanently embedded into the absorber. The heat transfer medium channels the absorber heat through the copper pipe. The absorber is encased in a highly insulated collector housing, which minimizes collector heat losses. The high quality thermal insulation provides temperature stability and is free from gas emissions. The cover consists of a solar glass panel with a very low iron content, thereby reducing reflection losses. The solar glass is 3.2 mm thick, making it very resistant to weather influences. Thermal insulation made from mineral fiber Non-coated aluminum frame sections Back panel made from aluminum-zinc coated sheet steel The glass is set into the collector frame with a continuous profiled seal, preventing water from penetrating into the collector. This ensures a long and reliable service life for all internal components. The collector housing consists of a one-piece non-coated aluminum frame into which the solar glass is permanently sealed. Up to twelve collectors can be joined quickly and easily to form a single collector array. For this, the standard equipment includes flexible connection pipes, sealed with O-rings (see picture below). A connection kit with clamping ring fittings enables the collector array to be quickly connected to the pipes of the solar circuit. The collector temperature sensor is installed in the solar circuit flow using a sensor well set. Flexible interconnection pipes 5354 729 v1.3 H Universal application on flat and sloped roofs or freestanding, vertical or horizontal installations, connect up to 12 collectors in one array for commercial or residential systems. Technical Data Technical Data Model - Vitosol 100-F SV1B SH1B Total surface area ft.2 (m2) 27.0 (2.51) 27.0 (2.51) Absorber surface area ft.2 (m2) 25.0 (2.32) 25.0 (2.32) Aperture *1 ft.2 (m2) 25.1 (2.33) 25.1 (2.33) 41¾ 1056 93¾ 2380 2¾ 72 93¾ 2380 41¾ 1056 2¾ 72 75.4 75.4 4.15 0.0114 4.15 0.0114 Dimensions *2 Width inches mm inches mm inches mm Height Depth Optical efficiency*3 % Heat loss coefficient U1 Heat loss coefficient U2 W/(m2 . K) W/(m2 . K2) Thermal capacity kJ(m2 . K) Weight lb (kg) Fluid capacity (heat transfer medium) 4.5 4.5 96.8 (43.9) 96.8 (43.9) USG L 0.44 1.67 0.62 2.33 Maximum working pressure *4 psig bar 87 6 87 6 Maximum stagnation temperature *5 ºF (ºC) 395 (196) 395 (196) Connection inches mm ¾ 22 ¾ 22 Roof construction with adequate load capacity for prevailing wind forces Requirements for installation surface and anchorage *1 *2 Important for system design considerations. Dimensions rounded to the nearest ¼ inch. *3 Based on absorber surface area. *4 In sealed systems, operating pressure of at least 15 psig + 0.45 psig x static head (ft.) / 1 bar + 0.1 bar x static head (m) must be present in the collectors in cold condition. *5 The stagnation temperature is the temperature which applies to the hottest point of the collector at a global radiation intensity of 3412 Btu/h / 1000 W when no heat is conducted by the heat transfer medium. Model SV1B Model SH1B 93¾”/2380 mm 2¾”/ 72 mm CS 41¾”/1056 mm 34½”/876 mm 1½” 38 mm 3½” 90 mm CR CR 3½” 90 mm 5354 729 v1.3 93¾”/2380 mm 86½”/2200 mm 41¾”/1056 mm 2¾”/ 72 mm 1½” 38 mm CS Legend CR Collector return (inlet) CS Collector supply (outlet) 3 Standard Equipment/Accessories General connection set Required to connect solar collector to system piping. One set required per collector array - max. 269 ft2 (25 m2). Part No. 7248 240 Pipe connection set Required to connect multiple solar collectors. Part No. 7248 239 x2 Standard equipment Accessories Accessories (individually packed, depending on order): - Mounting hardware with technical literature - Interconnection pipes with insulation - General connection set - Sensor well set - Solar Divicon (pumping station for the collector circuit) - Automatic air vent with air separator - Fast air vent valve with tee and shutoff valve - System filling manifold - Solar hand pump - Solar expansion tank - Heat transfer medium Sloped roof hardware Required for mounting collector directly onto shingled roof. Raises collector 3½” / (889 mm) above the roof. Roof bracket SCU 124/224 Electronic differential temperature control for solar heating. Installation rail Flat roof hardware Required for freestanding, flat roof installations. Mounting hardware The mounting hardware consists of components required for the relevant method of installation, such as: Roof brackets, mounting plates, mounting rails, connecting elements for mounting rails, clamping bolts, screws and nuts. Viessmann Manufacturing Company (U.S.) Inc. 45 Access Road Warwick, Rhode Island • 02886 • USA 1-800-288-0667 • Fax (401) 732-0590 www.viessmann-us.com • info@viessmann-us.com 4 Please note Viessmann offers complete solar heating system combi packages, as well as comprehensive design support in order to facilitate the component selection process. Viessmann Manufacturing Company Inc. 750 McMurray Road Waterloo, Ontario • N2V 2G5 • Canada 1-800-387-7373 • Fax (519) 885-0887 www.viessmann.ca • info@viessmann.ca Technical information subject to change without notice. Vitosol 100-F, Models SH1B and SV1B come fully assembled in shrink-wrap packaging and ready to be connected. Solar Divicon Preassembled pumping station for solar collector circuit. Includes: 3-speed pump (2 sizes), pressure gage, 2 thermometers, 2 ball valves, pressure relief valve, flow meter, 2 flowcheck valves, air separator, system fill manifold, and foam insulation cover. Part No. 7134 799 (for DN20) 7134 800 (for DN25) 5354 729 v1.3 Tyfocor non-toxic heating liquid for solar heating systems with active anti-corrosion and anti-ageing protection. Frost protection: to -31ºF (-35ºC) Specific gravity at 68ºF (20ºC): 1.032 to 1.035 g/cm3 to ASTM D 1122 Viscosity at 68ºF (20ºC): 6.5 to 8.0 mm2/s to DIN 51562 pH value: 7.5 to 8.5 to ASTM D 1287 Color: transparent, blue-green Container: 5.3 USG (20 L) in a disposable container Printed on environmentally friendly (recycled and recyclable) paper. Heat transfer medium
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Author : ebem Create Date : 2011:03:28 15:51:19Z Modify Date : 2011:03:28 16:09:26-04:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Format : application/pdf Creator : ebem Title : 5354 729 v1.3 Creator Tool : FreePDF XP 3.24 - http://shbox.de Metadata Date : 2011:03:28 16:09:26-04:00 Producer : AFPL Ghostscript 8.53 Document ID : uuid:82624c05-d85b-4df2-ab94-f19c63ce5edc Instance ID : uuid:6f277f0d-ec61-4009-9e7f-ebdccb10c352 Page Count : 4EXIF Metadata provided by EXIF.tools