Vision Automobile Electronics Co ZP3102US-5 Wireless PIR Motion Sensor User Manual INSTALLATION GUIDE

Vision Automobile Electronics Industrial Co Ltd Wireless PIR Motion Sensor INSTALLATION GUIDE

User manual

Download: Vision Automobile Electronics Co ZP3102US-5 Wireless PIR Motion Sensor User Manual INSTALLATION GUIDE
Mirror Download [FCC.gov]Vision Automobile Electronics Co ZP3102US-5 Wireless PIR Motion Sensor User Manual INSTALLATION GUIDE
Document ID2732611
Application IDFUS/MmiE7ZTmea+hB0HwNg==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize52.45kB (655625 bits)
Date Submitted2015-08-31 00:00:00
Date Available2015-09-16 00:00:00
Creation Date2014-12-17 11:51:41
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2015-08-20 13:32:35
Document TitleINSTALLATION GUIDE:
Document CreatorMicrosoft® Word 2010
Document Author: wendy

Installation & Operation Manual
ZP3102IN-5
ZP3102MY-5
ZP3102EU-5
ZP3102RU-5
ZP3102US-5
ZP3102IL-5
ZP3102KR-5
ZP3102HK-5
ZP3102JP-5
ZP3102BR-5
ZP 3102-5
V1 1031125 6B1Z-31002
Wireless PIR Motion Sensor
(Temperature Sensor Built-In)
Z-Wave Command Classes:
Introduction
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BASIC
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V4 (mapping _COMMAND_CLASS_BASIC)
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Thanks for choosing the Vision’s wireless PIR motion sensor of the home security device.
TM
This sensor is a Z-Wave
enabled device (interoperable, two-way RF mesh networking
TM
technology) and is fully compatible with any Z-Wave
enabled network and it’s security
TM
framework. Every mains powered Z-Wave
enabled device acts as a signal repeater and
multiple devices result in more possible transmission routes which helps eliminate “RF
dead-spots”.
TM
TM
Z-Wave
enabled device displaying the Z-Wave
logo can also be used with it
regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-Wave
TM
TM
enabled networks. This sensor monitors movement, and send Z-Wave
signal when
movement is detected inside the building. With Temperature sensor built inside, it will
send the signal out when temperature changed. When the device is secure included into
Z-Wave network, above communication will be encrypted.
Product Description and Specification
*** For indoor use only ***
Installation
TM
Notice: If you are installing the entire Z-Wave system for the first time, please refer to the
TM
installation guide of Z-Wave
Interface Controller before installing ZP3102.
Specification:
Package Content:
Protocol: Z-Wave™ (ZM5202)
Frequency Range:
865.22MHz (ZP3102IN-5)
868.10MHz (ZP3102MY-5)
868.42MHz (ZP3102EU-5)
869.00MHz (ZP3102RU-5)
908.42MHz (ZP3102US-5)
916.00MHz (ZP3102IL-5)
919.70MHz (ZP3102KR-5)
919.80MHz (ZP3102HK-5)
920.00MHz~928.00MHz (ZP3102JP-5)
921.42MHz (ZP3102BR-5)
Operating Range: Up to 100 feet line of sight
Operating Temp.: -15°C~ 40°C (5°F~104°F)
1pc
1pc
1pc
1pc
ZP 3102 sensor
Adhesive tape for sensor
CR123A Lithium Battery
Installation & Operation Manual
1.
Release cover tab to open the cover and insert a CR123A battery into the battery
compartment and LED will start to flash slowly, which means the sensor has not been
“inclusion” yet.
2.
Close the cover back to sensor.
3.
For “Inclusion (Auto-Inclusion)” in (adding to) a network: To add the ZP3102 to your
Z-Wave network (inclusion), place your Z-Wave primary controller into inclusion mode
and the distance between sensor and controller is suggested to be in one meter.
Press the Program Switch of ZP3102 for sending the NIF. After sending NIF, Z-Wave
will send the auto inclusion, otherwise, ZP3102 will go to sleep after 10 seconds. (P.S.:
Press the Program Switch to send NIF again for inclusion if the auto inclusion did not
success. The ZP3102 will go to sleep after 20 seconds if the inclusion did not work).
For “Exclusion” from (removing from) a network: To remove the ZP3102 from your
Z-Wave network (exclusion), place your Z-Wave primary controller into “exclusion”
mode, and following its instruction to delete the ZP3102 to your controller. Press the
Program Switch of ZP3102 once to be excluded. The LED on the ZP3102 should start
to flash.
For “Association”: removing the cover of the ZP3102 to get into “Awake” mode, then
TM
put the Z-Wave Interface Controller into “association”, and following its instruction to
associate the ZP3102 with other device. Close the cover back after “association”
done, afterward the ZP3102 will get into “Sleep” mode for power saving. Support one
association group (5 nodes).
Battery: Panasonic CR123A * 1PC
-1-
-2-
4.
Awake Mode:
It will be triggering after opening the front cover (refer Table 2), also the red LED will
keep on lasting 10 seconds and ZP3102 will send “Wake Up Notification” after 10
seconds.
5.
Auto Wake Up:
Use “Wake Up” command to set up the awaking time (from 10 minutes to 1 week) and
send the wake up notification to controller
6..
Battery Capacity Detection:
* Use “Battery Get” command to have the battery capacity back in %
* It will detect the battery capacity automatically
* Low Battery Auto Report when power is lower than 2.6V +/- 0.1V
7.
Temperature Report:
The user needs to get the controller for receiving the current temperature except when
the temperature +2°C or -2°C degree then the sensor will automatically report to the
controller. (ZP3102 will send the Multilevel Sensor Report to Controller)
8.
Configuration Command Class:
Parameter 1
Byte
Parameter 2
Parameter 3
Parameter 4
Value
1 ~ 255 (unsigned decimal) Minutes
(default: 3 minutes)
0x00 (Celsius) / 0x01 (Fahrenheit)
(default: 0x00)
1~7
(default: 4)
-10 ~ -1, 0 ~ 10 (signed decimal in Celsius)
(0xF6~0xFF, 0x0~0xA, default: 0x00)
(Table 1)
(Parameter 1) Re-trigger duration: User can change value from 1 to 255 minutes to
setup the re-trigger time when there is no movement detected in the period of time.
Default is 3 minutes.
(Parameter 2) Celsius / Fahrenheit switching function.
(Parameter 3) Infrared sensor sensitivity adjustment, 7 levels sensitivity, 1 = most
sensitive, 7 = most insensitive, default values= 4
(Parameter 4) User Defined Celsius Adjustment , for user's own choice
9.
Using adhesive tape to mount ZP3102 at 2 meters above surface. To enhance proper
operation, place ZP3102 on the angle which can detect the room widely. The solid
area means the detector’s coverage range.
-3-
10.
Factory Default Reset: Remove cover to trigged tamper switch, LED ON & send out Alarm
Report. Press Program Switch 10 times within 10 seconds, ZP3102 will send the “Device
Reset Locally Notification” command and reset to the factory default. (Remark: This is to be
used only in the case of primary controller being inoperable or otherwise unavailable.)
11.
All the rest commands depend on Z-Wave standard.
Operation
1.
Walk in front of ZP3102, sensor will send Basic set On (0xFF) , LED willl flash once
Operation
and please refer to status report as table below.
1. Walk in front of ZP3102, sensor will send Basic set (On) and Alarm
2. If no movement detected in three minutes (default is 3 minutes - based on user’s
configuration
setting,Level:0xFF,
refer Table 1, Parameter
1) will send
Basic will
Set OFF
(0x00),
Report
(Type:0x07,
Event=0x08),
the LED
flash
once.LED
will flash once, and refer to table for status.
2. If no movement detected in three minutes (default is 3 minutes 3. The ZP3102 sensor equipped with tamper switch. If the tamper switch is triggered (or
based
on user’s
configuration
setting)
will
send
Basic
Setwill(Off)
andand refer
remove
the cover),
the PIR sensor
will send
Alarm
Report,
LED
go solid,
to table
for status.
Alarm
Report
(Type:0x07, Level:0x00, Event=0x00)
4.
switch
is closed
(or closed
the cover),
willIfsend
3. If the
Thetamper
ZP3102
sensor
equipped
with
tamperZP3102
switch.
theAlarm
coverReport,
of
LED will go off, and refer to table for status.
sensor is removed, the PIR sensor will send an alarm report (Type:0x07,
5. Alarm report willl not be send if there is no association set. Before closing the tamper
Level:0xFF,
Event:0x03)
thesensor
Z-Wave™
Controller, and the
switch (or closed
the cover),tothe
is underInterface
“Awake” mode.
LED will go solid.
4. If the cover is closed, ZP3102 will
-4- send Alarm Report (Type:0x07,
Level:0x00, Event=0x00), and the LED will go off.
(Movement)
Notification
V4
Notification Type
0x07
0x07
Notification
Event
0x08(Motion Detected)/
0x00 (no movement after 3 mins)
0x03(remove cover)/
0x00 (cover closed)
Notification
Parameter
0x08
0x03
Alarm V1
(Movement &
Tamper Switch)
Alarm Type
Alarm Level
Notification V4
(Tamper Switch)
0x07
0x00 (No
movement after 3
mins)
0xFF (Motion
detected)
(Table 2)
6.
Support OTA Firmware update from controller. Please refer to your controller manual.
Once OTA function success, please make sure to exclusive the device & inclusive
again before use the device.
Federal Communications Commission Statement
This equipment has been followed to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try and
correct the interferene by one of the following measures:
Reorient or relocate the receiving antenna,
Increase the separation between the equipment and receiver,
Connect the equipment into and outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undersired
operation.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this equipment.
Limited Warranty
Vision Guarantees that every wireless PIR sensor is free from physical defects in material
and workmanship under normal use for one year from the date of purchase. If the product
proves defective during this one-year warrany period, Vision will replace it free of charge.
Vision does not issue any refunds. This warnnty is extended to the original end user
purchase only and is not transferable. This warranty does not apply to : (1) damage to units
caused by accident, dropping or abuse in handling, or any negligent use; (2) units which
have been subject to unauthorized repair, taken apart, or otherwise modified; (3) units not
used in accordance with instruction; (4) damanges exceeding the cost of the produt; (5)
transit damage, initial installation costs, removal cost, or reinstallation cost.
For information on addional devices, plesae visit us at www.visionsecurity.com.tw
-5-
-6-
Industry Canada Notice
Operation is subject to the following two conditions: (1) this device may
not cause interference and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
Industry Canada Caution
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d'IndustrieCanadaapplicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Tagged PDF                      : No
XMP Toolkit                     : 3.1-701
Create Date                     : 2014:12:17 11:51:41+08:00
Creator Tool                    : Microsoft® Word 2010
Modify Date                     : 2015:08:20 13:32:35+08:00
Metadata Date                   : 2015:08:20 13:32:35+08:00
Format                          : application/pdf
Creator                         : wendy
Title                           : INSTALLATION GUIDE:
Producer                        : Microsoft® Word 2010
Document ID                     : uuid:e6802312-67b8-4a08-baa1-127a5cd6eae0
Instance ID                     : uuid:4c62d45a-e4c5-4bb6-b223-0b0f562c63fb
Has XFA                         : No
Page Count                      : 5
Language                        : zh-TW
Author                          : wendy
EXIF Metadata provided by EXIF.tools
FCC ID Filing: KFR-ZP3102US-5

Navigation menu