Vision Automobile Electronics Co ZW4102US Z-Wave Curtain Module Relay Output User Manual INSTALLATION GUIDE

Vision Automobile Electronics Industrial Co Ltd Z-Wave Curtain Module Relay Output INSTALLATION GUIDE

Manual

Download: Vision Automobile Electronics Co ZW4102US Z-Wave Curtain Module Relay Output User Manual INSTALLATION GUIDE
Mirror Download [FCC.gov]Vision Automobile Electronics Co ZW4102US Z-Wave Curtain Module Relay Output User Manual INSTALLATION GUIDE
Document ID2328839
Application ID7081Qtc0vFRRscK5PoBrTA==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize20.74kB (259268 bits)
Date Submitted2014-07-18 00:00:00
Date Available2014-07-21 00:00:00
Creation Date2014-03-18 17:37:25
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2014-03-18 17:37:25
Document TitleINSTALLATION GUIDE:
Document CreatorMicrosoft® Word 2010
Document Author: wendy

Operation
1.
Close or open the curtain that attached to ZW4101 or ZW4102 by Z-Wave™ Interface Controller ,
or manually press the button switch on the curtain.
Federal Communications Commission Statement
This equipment has been followed with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try and correct the
interferene by one of the following measures:
Reorient or relocate the receiving antenna,
Increase the separation between the equipment and receiver,
Connect the equipment into and outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undersired
operation.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this equipment.
Limited Warranty
Vision Guarantees that every Curtain Control Module is free from physical defects in
material and workmanship under normal usage for one year from the date of purchase. If
the product proves defective during this one-year warrany period, Vision will replace it free
of charge. Vision does not issue any refunds. This warnnty is extended to the original end
user purchase only and is not transferable. This warranty does not apply to : (1) damage to
units caused by accident, dropping or abuse in handling, or any negligent usage; (2) units
which have been repaired, taken apart, or modified by an unauthorized personnel; (3) units
not used in accordance with instruction; (4) damanges exceeding the cost of the produt; (5)
transit damage, initial installation costs, removal cost, or reinstallation cost.
For information on addional devices, plesae visit us at www.visionsecurity.com.tw
ZW4101/4102
-3-
V0
1030318
6B1Z-41001
Installation & Operation Manual
ZW 4101IN
ZW 4101EU
ZW 4101RU
ZW 4101US
ZW 4101IS
ZW 4101BR
ZW 4101JP
Z-Wave Curtain Control Module, Signal Output
ZW 4102IN
ZW 4102EU
ZW 4102RU
ZW 4102US
ZW 4102IS
ZW 4102BR
ZW 4102JP
Z-Wave Curtain Control Module, Relay Output
Introduction
Thanks for choosing the Vision’s curtain control module of the home automation device.
This module is a Z-Wave™ enabled device (interoperable, two-way RF mesh networking
technology) and is fully compatible with any Z-Wave™ enabled network. Every mains
powered Z-Wave enabled device acts as a signal repeater and multiple devices result in
more possible transmission routes which helps eliminate “RF dead-sports”
Z-Wave™ enabled devices displaying the Z-Wave™ logo can also be used with it
regardless of the manufacturer, and ours can also be used in other manufacturer’s
Z-Wave™ enabled networks. Users easily control the curtain to open and close by sending
Z-Wave™ signal from Z-Wave™ Interface Controller. This module will send open/close
signal to the appliance that attached to this module by receiving Z-Wave™ signal from
controller or manually switch. Our special design the curtain not only can be opened and
closed but also can be stopped under the Multilevel Switch command on the controller.
This module also acts as repeater (supporting FLiRS devices).
Relay Normal Output: 14VDc, 5A (max)
OPEN output: 14VDc, 5A (max)
CLOSE output: 14VDc, 5A (max)
STOP output: 14VDc, 5A (max)
Installation
Notice: If you are installing the entire Z-Wave™ system for the first time, please refer to the installation
guide of Z-Wave™ Interface Controller before installing ZW 4101 / ZW 4102 Curtain Module.
1.
Product Description and Specification
*** For indoor use only ***
2.
Specification:
Package Content:
Protocol: Z-Wave™ (ZM3102N)
Frequency Range:
865.22MHz (ZW4101IN/ZW 4102 IN)
868.42MHz (ZW 4101EU/ZW 4102 EU)
869.00MHz (ZW 4101RU/ZW 4102 RU)
908.42MHz (ZW 4101US/ZW 4102 US)
916.00MHz (ZW 4101IS/ZW 4102 IS)
921.42MHz (Z W 4101BR/ZW 4102 BR)
920-928Mhz (ZW4101JP/ZW 4102 JP)
Operating Range: Up to 100 feet line of sight
Operating Temp.: -15°C~ 60°C (5°F ~140°F)
Operating Voltage: 12V
Current Consumption: 25mA
1pc
1pc
ZW 4101 or ZW 4102 Curtain Control
Module
Installation & Operation Manual
Connect the following wires with curtain’s manual switch or switch’s signal. User can skip switch if
it is not necessary.
Wire Color
ZW 4101
ZW 4102
RED
POWER
POWER
BLACK
GROUND
GROUND
WHITE
OPEN SIGNAL OUTPUT
OPEN RELAY-COM
WHITE/BLACK
OPEN RELAY-NO
GRAY
CLOSE SIGNAL OUTPUT
CLOSE RELAY-COM
GRAY/BLACK
CLOSE RELAY-NO
BROWN
STOP SIGNAL OUTPUT
STOP RELAY-COM
BROWN/RED
STOP RELAY-NO
For “Inclusion” in (adding to) a network: Put the Z-Wave™ Interface Controller into“inclusion”
mode, and following its instruction to add the ZW 4101 / ZW4102 to your controller. To get in the
“inclusion” mode, the distance between module and controller is suggested to be in one meter.
Press the program switch on the module once to be included.
For “Exclusion” from (removing from) a network: Put the Z-Wave™ Interface Controller into
“exclusion” mode, and following its instruction to delete the ZW 4101 / ZW4102 from your
controller. Press the program switch on the module once to be excluded.
Note: LED setting light will flash (RED) continuously in Exclusion condition.
3.
Z-Wave™ Command Class
COMMAND_CLASS_BASIC (Mapping COMMAND_CLASS_SWITCH_MULTILEVEL)
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_VERSION
ZW4101 Signal Output:
OPEN output: -VE, 100mA (max)
CLOSE output: -VE, 100mA (max)
STOP output: -VE, 100mA (max)
4.
Under the basic command, Status of “ON” (Basic Set,0xFF), Curtain to be opened. Status of
“OFF” (Basic Set,0x00), Curtain to be closed.
5.
Configuration command class: Parameter 1: Up output time, 1 byte value=1~255 seconds;
Parameter 2: Stop output time, 1 byte value=1~255 seconds; Parameter 3: Down output time, 1
byte value=1~255 seconds.
6.
Keeping press program switch for 5 seconds, curtain will reset back to factory preset
ZW4102 Relay Output:
-1-
-2-

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 2
Language                        : zh-TW
Tagged PDF                      : Yes
Title                           : INSTALLATION GUIDE:
Author                          : wendy
Creator                         : Microsoft® Word 2010
Create Date                     : 2014:03:18 17:37:25+08:00
Modify Date                     : 2014:03:18 17:37:25+08:00
Producer                        : Microsoft® Word 2010
EXIF Metadata provided by EXIF.tools
FCC ID Filing: KFR-ZW4102US

Navigation menu