K-980W
Installation Instructions
Pet-immune Wireless PIR Motion Detector
1. FEATURES
Uses TSI™ (Target Specific Imaging) technology for
distinction between humans and pets
•
Rejects RF interference up to 1000 MHz
•
•
Elegantly styled, sturdy case
Immune to pets weighing up to 36 kg (80 lb)
•
•
Keyhole-shaped slot for easy removal of PCB
Integral swivel bracket for wall or ceiling installation
•
Sealed chamber protects the optical system
•
•
On-board CE and FCC approved transmitter
•
Programmable pulse counter (1, 2, 3 or 5 pulses)
•
9 Volt battery powered, with unique energy saving
circuitry
•
Extremely-low current consumption – 0.013 mA
•
Automatically inhibited after detecting motion; reverts to
the ready state if no motion is detected for 2 minutes.
•
A TEST/NORMAL selector eliminates the 2-minute inhibit
period and sets the pulse counter to 1-pulse during walk
testing.
•
Automatic transmission of low-battery and tamper alerts
•
Three-position vertical adjustment
•
White light protection
•
Programmable 8-bit system code and 4-bit channel code
•
Surface and corner mounting
Figure 1. The K-980W Wireless Detector
2. SPECIFICATIONS
OPTICAL
Max. Coverage Range: 9 x 9 m (30 x 30 ft) / 90°
Pet Immunity: Immune to pets weighing up to 36 kg (80 lb)
under optimal environmental conditions.
Vertical Adjustment: 3-position adjustment scale: 1.8 m (6 ft),
2.1 m (7 ft) and 2.4 m (8 ft).
ELECTRICAL
Voltage: 9 Volt alkaline or lithium battery.
Standby Current: 0.013 mA.
LED: Walk Test & transmission.
Detector: Dual-element low-noise pyroelectric sensor.
Pulse Counter: Programmable to 1, 2, 3 or 5 pulses with walk-test
override.
Inhibit Timer: re-enables the unit about 2 minutes after alarm, if
no further motion is detected.
WIRELESS
Frequency (MHz): 315, 304, 404, 418, 433.92 or other
frequencies according to local requirements.
Alarm Transmission Duration: 2 seconds.
Encoding: 8-bit digital word, 256 combinations, pulse width
modulation.
Channels: 4 channels, switch selectable.
Battery Test: Automatic transmission of "Code 0" at 2-minute
intervals if the battery voltage drops below 7 V.
DE3582
Tamper Alert: Transmission of the "Channel 2" code at 2-minute
intervals, until the tamper switch is restored.
ENVIRONMENTAL
Operating Temperature: -10°C to 50°C (14°F to 122°F).
Storage Temperature: -20° to 60°C (-4°F to 140°F).
RFI Protection: Greater than 30 V/m up to 1000 MHz.
Note: The temperature range may be reduced due to battery
characteristics.
Compliance with Standards: Meets FCC Part 15 requirements;
The 433.92 MHz version complies with the European Council
Directive EMC 89/336/EEC & 92/31/EEC, and bears the CE mark
and certification.
MOUNTING
Height: 1.8 to 2.4 m (6 to 8 ft)
Installation Options: Surface or corner (without bracket);
surface or ceiling (with bracket).
Bracket Adjustment: 20° downward (only in non-pet immune
applications), 20° left and right.
PHYSICAL
Dimensions (H x W x D): 117 x 65 x 47 mm.
(4-5/8 x 2-9/16 x 1-7/8 in.).
Weight: 92 g (3.25 oz) without bracket, 107 g (3.8 oz) with bracket.
Color: White
3. INSTALLATION
3.1 Installation Hints
and remove it via the “keyhole” (see Figure 4).
Important! Under optimal environmental
conditions, the detector is immune to animals
weighing up to 36 kg (80 lb) that move on the
floor or climb on furniture, as long as this
activity takes place below 1 m (3 ft). Above 1
m (3 ft), the detector is immune to pets
weighing 18 kg (40 lb), but the pet immunity
will decrease as the pet gets closer to the detector. It is
therefore recommended to select a mounting location that
minimizes potential close proximity of animals.
When installing keep in mind the advice given in Figure 2 below:
Do not aim at heat sources
Mount on solid, stable surfaces
Do not expose to air drafts
Do not install outdoors
Prevent direct sunlight from
reaching the detector
Keep wiring away from
electrical power cables
Do not install behind partitions
3rd.Pull the PCB straight out and put it aside until required again.
4th.Refer to Figure 4 and punch out the mounting knockouts at
the rear wall of the base (for surface mounting) or mounting
knockouts at the angled sides of the base (for corner
mounting).
5th.Hold the base against the wall at the selected installation
location and mark the points for drilling.
6th.Drill the holes and insert the plastic anchors supplied (if
necessary).
7th.Return the PCB to its place: align the ”keyhole” with the head
of the vertical adjustment screw, press the PCB against the
base, slide the PCB up and adjust it as explained in Para. 3.8.
Figure 4. Inside View
3.3 Mounting with Swivel Bracket
1st.Remove the front cover as shown in Figure 3.
2nd.Remove the PCB and put it temporarily aside.
3rd.Punch out the large knockout in the round bulge at the top
part of the base (see Figure 5)
Figure 2. Installation Hints
3.2 Mounting without Swivel Bracket
1st.Remove the front cover as shown in Figure 3.
Figure 5. Attaching the Bracket
Figure 3. Cover Removal
2nd.Loosen the vertical adjustment screw, slide the PCB down
4th.Assemble the bracket as shown in Figure 5.
5th.Rotate the bracket to the desired position (see Figure 6) but
do not yet tighten the screw fully.
DE3582
Figure 6. Wall and Ceiling Positions of Bracket
6th.Press the bracket against the mounting surface and mark the
points for drilling. Drill out the holes and insert plastic
anchors.
7th.Attach the bracket to the mounting surface using the two
screws supplied.
H. Swivel the detector horizontally to face the desired direction,
but do not tilt it if this is a pet immune application.
However, if pets are not present it is advisable to tilt the
detector as much as 20° down. Figure 7 shows the tilt/swivel
possibilities.
This feature is very useful for zoning
purposes - activation of different type of
zones at the control panel.
The channel selector consists of a 4-key
DIP switch (see Figure 9). The channel
code is selected by setting the key with
the desired channel number to ON.
If there is a low battery condition, a LOW
BATTERY alert code (code "0") will be Figure 9. Channel
Code Selector
automatically transmitted once every 2
minutes, regardless of the channel selector setting. Code "0"
causes receivers equipped with a buzzer output to activate the
buzzer. Setting the 4 channel keys to OFF and initiating a
transmission is a way to check whether code "0" works.
Upon activation of the detector’s tamper switch (by removing the
front cover), channel "2" code will be automatically transmitted
once every 2 minutes, regardless of the channel selector setting.
Caution: Do not select channel 2 as the normal alarm channel,
because this will cause alarm and tamper events to have the
same channel code.
3.7 Setting the Pulse Counter
The location of the pulse count selector is indicated in Figure 5.
Refer to Figure 10 below and mount the jumper as desired.
Figure 7. Tilt/Swivel Limits
I. Once the detector is directed as desired, tighten the bracket
assembly screw well, to prevent any further change of position.
3.4 Battery Installation
The K-980W is powered by a 9-volt alkaline or lithium battery.
Remove the detector's front cover, snap the battery clip onto the
battery and place the battery in its place (below the printed circuit
board). Before testing, allow 10 minutes for the detector to
stabilize (the LED may light during this time).
Warning! For proper operation, use only alkaline or lithium type
batteries.
3.5 System Code Selection
The code selector consists of an 8-key
DIP switch (see Figure 8). Each key is
set to either ON or OFF position to create
a unique digital system code combination
(256 possibilities).
Select a digital code that matches the
one selected on the companion receiver.
All wireless detectors and the receiver
used in the alarm system must be set
to the same digital system code.
Figure 10. Pulse Counter Setting Options
3.8 Vertical Adjustment
A. Pet-Immune Applications
Figure 8. System
Code Selector
CAUTION: The code combination 2, 4, 5, 6, 7 ON / 1, 3, 8 OFF
is a factory setting that must be avoided. Also avoid codes such
as all keys ON, all keys OFF or alternating ON-OFF settings.
To maintain maximum coverage range and
pet immunity, the vertical adjustment scale
must be adjusted in accordance with the
actual mounting height (refer to Figure 11).
Loosen the vertical adjustment screw and
slide the printed circuit board up or down until
the pointer shows the actual mounting height on the scale.
When done, re-tighten the screw well.
3.6 Channel Code Selection
The Visonic Ltd. wireless security systems have a multi-channel
capability. Each wireless K-980W detector can be set to transmit
one of 4 different channel codes. Each channel code activates a
particular output circuit of the companion receiver.
Figure 11. Vertical Adjustment
DE3582
B. Pet-Free Locations
To obtain the best coverage possible where no pets are present,
mount the detector with the integral bracket at any desired height
between 1.8 m (6 ft) and 2.4 m (8 ft). Then set the vertical
adjustment scale to the 2.4 m (8 ft) position and tilt the detector
20° down.
3.9 Setting the TST/NORM Jumper
Since battery saving is of utmost importance in normal use of the
detector unit, an automatic timer inhibits the detector for
approximately 2 minutes after each transmission. During this
period, the transmitter cannot be triggered again by subsequent
motion within the protected area. The detector is automatically
rearmed 2 minutes after the last motion was detected.
For rapid walk testing of the coverage pattern, you must eliminate
the 2 minute inhibit interval between successive alarms. The
NORM/TEST selector, when set to TEST, overrides the 2-minute
rearm timer, and also sets the pulse counter to 1 PULSE.
Remember that in the TEST mode, tamper and low battery alerts
will be transmitted at 1/2 second intervals instead of the usual 2minute intervals. When the selector is reset to NORM, the rearm
timer reverts to normal operation.
TEST Position Setting the jumper as shown
overrides the rearm timer and the pulse counter,
allowing you to walk test the detector rapidly.
protective beam. Allow the unit to re-stabilize for 5 seconds
after each test.
F. In pet immune applications, continue the test by sending the
house pet into the protected area. Make sure it does not
trigger the detector by moving across the protected area and
by climbing on furniture within that area.
G. Remove the cover and set the pulse counter as required for
the particular application.
H. Set the NORMAL/TEST selector to NORM, mount the cover
and wait 5 minutes outside the coverage area. Then re-enter
the coverage area and verify that the LED lights (response will
be immediate only if the pulse counter is set to 1 pulse).
If you continue moving within the detector's field of view, the
LED will turn OFF and the unit will remain disabled as long as
movement continues, due to the 2-minute battery saving
rearm timer. The unit will be rearmed provided that no motion
is detected for approximately 2 minutes, and will again be
ready to detect and signal.
CAUTION: The range and coverage area of the unit should
be checked at least once a year. To assure proper
continuous function, the end user should be instructed to
perform a walk test at the far end of the area to assure an
alarm signal prior to each time the alarm system is armed.
NORMAL Position: Setting the jumper as
shown re-enables the 2-minute rearm timer and
the pulse counter.
3.10 Final Testing
A. Snap the battery clip onto the 9 Volt alkaline or lithium battery
and allow ten minutes for the unit to stabilize before testing.
B. Adjust the vertical calibration position per Para. 3.8.
C. Set the Normal/Test selector to TEST.
D. Put the cover back in place.
E. Walk-test the entire protected area by walking slowly across
it, observing the LED. The LED lights whenever you cross a
4. WARNINGS
Visonic Ltd. wireless systems are very reliable and are tested to
high standards. However, due to their low transmitting power
(required by FCC and other regulatory authorities), there are
some limitations to be considered:
A. Receivers may be blocked by radio signals on or near their
operating frequencies, regardless of the code selected.
B. Receivers can only respond to one transmitted radio signal at
a time.
C. Wireless equipment should be tested regularly (at least once a
week) to determine if there are sources of interference and to
protect against faults.
WARNING! Changes or modifications to this unit not expressly
approved by the party responsible for compliance could void the
user's authority to operate the equipment
Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in residential installations. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful
interference to radio and television reception. However, there is no
guarantee that interference will not occur in a particular installation. If
this device does cause such interference, which can be verified by
turning the device off and on, the user is encouraged to eliminate the
interference by one or more of the following measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
– Connect the device to an outlet on a circuit different from the one
which supplies power to the receiver.
– Consult the dealer or an experienced radio/TV technician.
This device has been tested and found to comply with the limits for a
WARRANTY
Visonic Ltd. and/or its subsidiaries and its affiliates ("the Manufacturer") warrants its
products hereinafter referred to as "the Product" or "Products" to be in conformance with
its own plans and specifications and to be free of defects in materials and workmanship
under normal use and service for a period of twelve months from the date of shipment by
the Manufacturer. The Manufacturer's obligations shall be limited within the warranty
period, at its option, to repair or replace the product or any part thereof. The Manufacturer
shall not be responsible for dismantling and/or reinstallation charges. To exercise the
warranty the product must be returned to the Manufacturer freight prepaid and insured.
This warranty does not apply in the following cases: improper installation, misuse,
failure to follow installation and operating instructions, alteration, abuse, accident or
tampering, and repair by anyone other than the Manufacturer.
This warranty is exclusive and expressly in lieu of all other warranties, obligations or
liabilities, whether written, oral, express or implied, including any warranty of
The Manufacturer does not represent that its Product may not be compromised and/or
circumvented, or that the Product will prevent any death, personal and/or bodily injury
and/or damage to property resulting from burglary, robbery, fire or otherwise, or that the
Product will in all cases provide adequate warning or protection. User understands that a
properly installed and maintained alarm may only reduce the risk of events such as
burglary, robbery, and fire without warning, but it is not insurance or a guarantee that such
will not occur or that there will be no death, personal damage and/or damage to property
as a result.
The Manufacturer shall have no liability for any death, personal and/or bodily injury
and/or damage to property or other loss whether direct, indirect, incidental,
consequential or otherwise, based on a claim that the Product failed to function.
However, if the Manufacturer is held liable, whether directly or indirectly, for any loss or
damage arising under this limited warranty or otherwise, regardless of cause or origin, the
Manufacturer's maximum liability shall not in any case exceed the purchase price of the
DE3582
merchantability or fitness for a particular purpose, or otherwise. In no case shall the
Manufacturer be liable to anyone for any consequential or incidental damages for breach
of this warranty or any other warranties whatsoever, as aforesaid.
This warranty shall not be modified, varied or extended, and the Manufacturer does not
authorize any person to act on its behalf in the modification, variation or extension of this
warranty. This warranty shall apply to the Product only. All products, accessories or
attachments of others used in conjunction with the Product, including batteries, shall be
covered solely by their own warranty, if any. The Manufacturer shall not be liable for any
damage or loss whatsoever, whether directly, indirectly, incidentally, consequentially or
otherwise, caused by the malfunction of the Product due to products, accessories, or
attachments of others, including batteries, used in conjunction with the Products.
Product, which shall be fixed as liquidated damages and not as a penalty, and shall be the
complete and exclusive remedy against the Manufacturer.
Warning: The user should follow the installation and operation instructions and among
other things test the Product and the whole system at least once a week. For various
reasons, including, but not limited to, changes in environmental conditions, electric or
electronic disruptions and tampering, the Product may not perform as expected. The user
is advised to take all necessary precautions for his/her safety and the protection of his/her
property.
6/91
VISONIC LTD. (ISRAEL): P.O.B 22020 TEL-AVIV 61220 ISRAEL. PHONE: (972-3) 645-6789, FAX: (972-3) 645-6788
VISONIC INC. (U.S.A.): 10 NORTHWOOD DRIVE, BLOOMFIELD CT. 06002-1911. PHONE: (860) 243-0833, (800) 223-0020 FAX: (860) 242-8094
VISONIC LTD. (UK): UNIT 1, STRATTON PARK, DUNTON LANE, BIGGLESWADE, BEDS. SG18 8QS. PHONE: (01767) 600857 FAX: (01767) 601098
Internet Web Site: www.visonic.com
VISONIC LTD. 1999
D3582
K-980W
DE3582- (REV. 1, 10/99)

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Create Date                     : 2001:05:18 06:53:32
Producer                        : Acrobat Distiller 4.0 for Windows
Modify Date                     : 2001:05:18 06:53:34-04:00
Page Count                      : 5
EXIF Metadata provided by EXIF.tools
FCC ID Filing: GSAK980W

Navigation menu