Visonic KP160 Touch screen keyprox User Manual User manual 22015
Visonic Ltd. Touch screen keyprox User manual 22015
Visonic >
Contents
- 1. manual
- 2. Users Manual
- 3. User Manual
manual
K P-1 6 0 PG2 Touch Screen Keyprox User’s Guide T a ble of Cont e nt s 1. INTRODUCTION .......................................................................................................... 2 2. INSTALLATION............................................................................................................ 3 2.1 Inserting Battery.................................................................................................. 3 2.2 Closing Battery Compartment Cover .................................................................. 3 2.3 Wall Mounting Options ....................................................................................... 4 2.4 Enrolling the KP-160 PG2................................................................................... 6 2.5 Configuring the KP-160 PG2 Parameters........................................................... 6 2.6 Enrolling Proximity Tags ..................................................................................... 8 3. USING THE TOUCH SCREEN KEYPROX .................................................................. 9 3.1 Arming and Disarming the System ..................................................................... 9 3.2 Initiating Alarms ................................................................................................ 10 3.3 System Status and Indications ......................................................................... 10 3.4 Bypassing Zones .............................................................................................. 14 3.5 Controlling Home Automation Devices ............................................................. 14 3.6 Other Functions ................................................................................................ 15 APPENDIX A: SPECIFICATIONS .................................................................................. 15 APPENDIX B: COMPLIANCE WITH STANDARDS....................................................... 16 D-303169 KP-160 PG2 User’s Guide 1 . I N T RODU CT I ON KP-160 PG2 is a 2-way wireless PowerG touch screen keyprox for the PowerMaster family control panels. The KP-160 PG2 enables most common everyday user functions: Arm and Disarm the alarm system. Initiate Emergency, Fire and Panic alarms. Control home automation devices. Review system status. Perform programmable predefined functions. KP-160 PG2 is operated by proximity tags. When authorization is required the user presents a valid proximity tag to the built-in tag reader In addition, the KP-160 PG2 supports panels featuring Partitions. Partitioning allows you to select up to three controllable areas; each partition can be armed and disarmed independently regardless of the status of the other two partitions by the same or different users (see keys marked "7" in the "Icon and Key Indications" Figure). The KP-160 PG2 can be wall-mounted using the supplied bracket or be used as a portable unit. For compliance with various international standards, the KP-160 PG2 is equipped with two tamper switches that can be defined to detect when the cover of the battery compartment is removed or when the unit is removed from its mounting bracket. Other features of the KP-160 PG2 include: Easy-to-use intuitive graphical touch user interface Proximity-tag operated, no need for user to remember codes Allows all users' every day actions Panel can be installed in hidden location 8 or 32 per system (depending on the control panel), suitable for any installation Status, Alarm, Memory, Trouble and Ready indications. Automatic reporting of low battery. Back lighting. Exit/entry beeps Enrollment of proximity tags directly into control panel or via tag reader. Long battery life expectancy (for typical use). D-303169 KP-160 PG2 User’s Guide 2 . I N ST ALLAT I ON 2 .1 I nse rt ing Ba t t e ry CAUTION! Risk of explosion if battery is replaced by an incorrect type. Dispose of used battery according to manufacturer's instructions. Figure 1 – Battery Insertion Insert two 1.5V batteries in each slot while ensuring battery polarity. 2 .2 Closing Ba t t e ry Com pa rt m e nt Cove r Port a ble I nst a lla t ion (U sing Ba t t e ry Cove r w it hout T a m pe r H ole ) D-303169 KP-160 PG2 User’s Guide Figure 2 - Battery Cover Mounting (part a) Wa ll-m ount e d I nst a lla t ion (U sing Ba t t e ry Cove r w it hout T a m pe r H ole – se e "A") Figure 3 - Battery Cover Mounting (part b) A. Tamper B. DC Power Connection 2 .3 Wa ll M ount ing Opt ions The KP-160 PG2 unit mounting options are illustrated in the following drawings. Wall Mounting Figure 4a – Wall Mounting 1. Drill 3 mounting holes 2. Position the bracket and secure with 3 screws 3. Attach the unit to the bracket 4. Secure the unit with the screw D-303169 KP-160 PG2 User’s Guide Wall Mounting with External Electrical Connector Figure 4b – Wall Mounting with External Electrical Connector 1. Secure bracket with 2 screws as shown in the two drawings above. 2. Attach the unit to the bracket. 3. Secure the unit with the screw D-303169 KP-160 PG2 User’s Guide 2 .4 Enrolling t he K P-1 6 0 PG2 Refer to the PowerMaster panel's Installer Guide and follow the procedure under the "02:ZONES/DEVICES" option of the Installer Menu. A flowchart of the procedure is provided below. Step Action Enter the Installer menu and select “02:ZONES/DEVICES” Select "ADD NEW DEVICE" Option See Note LCD Display 02.ZONES/DEVICES ADD NEW DEVICES MODIFY DEVICES Enroll the device or enter the 7-digit code that appears on the device's sticker. Select the desired keyprox Number ENROLL NOW or ENTR ID:XXX-XXXX K07: LCD Keypad ID No. 374-XXXX Configure the settings of the device Configure the Keyprox means scroll K07.DEV SETTINGS See section 2.5 and select Note: If the KP-160 PG2 is already enrolled, you can configure the KP-160 PG2 parameters via the “Modify Devices” option – see Step 2. 2 .5 Configuring t he K P-1 6 0 PG2 Pa ra m e t e rs K07.DEV SETTINGS Enter the main menu in the PowerMaster control panel, choose the number of the touch screen keyprox device to configure and follow the configuration instructions for the KP-160 PG2 touch screen keyprox. Option TAMPERS Configuration Instructions Define the active tamper. Option settings: Disabled (default); All Tampers and Battery Cover. SUPERVISION Define whether or not the control panel will monitor supervision messages sent by the keyprox (see Note). Option settings: ON (default) or OFF. D-303169 KP-160 PG2 User’s Guide Note: Every 5 minutes the keyprox performs a communication test session with the control panel (i.e. "Supervision signal) to check the integrity and quality of the Radio link. If the keyprox does not report a supervision signal at least once within a predefined time, a “MISSING” trouble alert is initiated. Therefore, if you take the keyprox out of the protected premises, switch the Supervision OFF to avoid the trouble alert. EXIT-ENTRY Beeps Define whether or not the keyprox will sound the exit and entry beeps or whether the keyprox will sound the beeps only when the system is armed AWAY and not when it is armed HOME. Option settings: ON; OFF (default) and OFF @ Home. Trouble Beeps Under trouble conditions, the panel sounder emits a series of 3 short reminder beeps once per minute. Here you determine whether to enable or disable this reminder beeping or just disable it at night. The “night” hours are defined in the factory but are usually from 8 PM (20:00) until 7:00 AM. Option settings: ON; OFF (default) and OFF @ night. Sounder Volume Define the volume level of the sounder. Option settings: Medium (default); Maximum and Minimum Screen Saver Enabling the function will turn off the display if no key is pressed for more than several seconds. Options settings: Disabled (default) and Enabled. Notes: 1) When the "SCREEN SAVER" menu on the PowerMaster control panel is configured as "refresh by key", touching the right side of the screen on the KP-160 PG2 device will return the device to normal display (refer to the PowerMaster Installer Guide, section 3.5.6). 2) When the "SCREEN SAVER" menu on the PowerMaster control panel is configured as "refresh by code", touching the right side of the screen on the KP-160 PG2 device and then presenting the proximity tag to the tag reader will return the device to normal display (refer to the PowerMaster Installer Guide, section 3.5.6). BUTTON () Select the function of the (AUX) key when pressed: Not used: No function assigned to AUX key. Status: Control panel displays and announces* the system status. Stop Beeps: Control panel and other devices in the system (such as keyproxs, sirens etc.) will stop beeping during the exit delay. Skip exit delay: Stop the exit delay immediately. X-10 (PGM): Activate the appliance controlled by the chosen X-10 D-303169 KP-160 PG2 User’s Guide unit(s) or the device wired to the PGM output. For more details on configuring the X-10/PGM output functions, see the corresponding sections of the control panel’s Installer Guide (“OUTPUTS” menu) and User Guide (“SCHEDULER” menu). Option settings: Not Used, Status (default); Stop Beeps, Skip exit delay; and X-10 (PGM). * Applicable only to control panels that support the voice option. AC POWER Connect Define whether or not to report power failure. Option settings: NOT Connected (default) and Connected to AC. 2 .6 Enrolling Prox im it y T a gs You can enroll proximity tags in the PowerMaster panel either via the KP-160 PG2 touch screen keyprox, as described below, or through the PowerMaster control panel, as described in the corresponding section of the control panel's User or Installer Guide. Each proximity tag corresponds to its User Code. Therefore, be sure that a corresponding User Code is programmed for each enrolled proximity tag (code "0000" is not allowed). For example, "T02:Tag" must be assigned to User Code 2 and "T14:Tag " must be assigned to User Code 14. Partition authorization of each proximity tag is identical to that of the corresponding User Code. For example, if User Code 3 is set to Partitions 1 and 3, "T03:Tag " will also be set to Partitions 1 and 3. Step Action Enter the Installer menu of the control panel and go to “02:ZONES/DEVICES” LCD Display 02.ZONES/DEVICES ADD NEW DEVICES Select "ADD NEW DEVICE" Option MODIFY DEVICES ENROLL NOW or When "ENROLL NOW" is displayed, press the AWAY key ( ) on the KP-160 PG2. The AWAY key and the Present Prox Tag key ( begin to blink Present the proximity tag to the KP-160 PG2 within the timeout period. If the enrollment is successful the display reads "DEVICE ENROLLED" and then shows the device details DEVICE ENROLLED T01:Tag (Prox) D-303169 KP-160 PG2 User’s Guide 3 . U SI N G T H E T OU CH SCREEN K EY PROX 3 .1 Arm ing a nd Disa rm ing t he Syst e m Step Operation User Actions (1) Select a PARTITION (if Partition is enabled) Arm AWAY Optional Keyboard & Panel Response Any combination of The selected key blinks. Arm HOME Disarm (OFF) Optional Optional Quick arm AWAY (If Quick Arm is enabled) ( 2 sec.) (3) INSTANT ( 2 sec.) ) begin to blink and prompt you to present your Tag. The keyprox's LED blinks red once to indicate transmission of the arming command to the control panel. (After arming HOME/ AWAY) LATCHKEY The selected key and the "Present Prox Tag" icon (4) (4) (3) Quick arm HOME (If Quick Arm is enabled) (4) (5) (7) (After arming AWAY) (6) (7) The LED and the buzzer then indicate the control panel's response – see “System Status and Indications” section 3.3. Notes: 1. If Partition is disabled at the control panel, skip Step 1. 2. If Partition is enabled at the control panel and a partition was not selected in Step 1, Step 2 will activate all of the partitions assigned to the user. 3. The Quick arm functions only if enabled at the control panel. 4. If the action is not completed while the selected arming key is blinking, the desired function will not be executed. 5. Press the INSTANT key within maximum 8 seconds timeout period after completing the previous step. This will delete the entry delay for the current arming session. INSTANT is available only if supported in the PowerMaster control panel (refer to the PowerMaster Installer Guide). D-303169 KP-160 PG2 User’s Guide 6. 7. For LATCHKEY activation, press the LATCHKEY key within maximum 8 seconds timeout period after completing the previous step. LATCHKEY is available only if the LATCHKEY feature is enabled in the PowerMaster control panel (see PowerMaster Installer Guide).You can perform the LATCHKEY and INSTANT functions, one after the other. The order is not important. LATCHKEY and INSTANT functions can be operated only during exit delay. While in INSTANT / LATCHKEY, the small circle icon on the upper right side of the INSTANT / LATCHKEY icon lights. 3 .2 I nit ia t ing Ala rm s Alarms Emergency alarm Actions ( 2 sec.) Fire alarm ( 2 sec.) Panic alarm Response Notes See section 3.3. When pressing the Fire or Emergency icons, the KP-160 PG2 starts beeping. After pressing the button for approx. 2 seconds, the KP-160 PG2 sends the command. See section 3.3. See section 3.3. ( 2 sec.) When pressing the Fire and Emergency icons together, the KP-160 PG2 starts beeping. After pressing the button for approx. 2 seconds, the KP-160 PG2 sends the Panic command. 3 .3 Syst e m St a t us a nd I ndic a t ions When executing a command, the keyprox's LED ("30" in the "Icon and Key Indications" Figure) blinks red once to indicate transmission of the command to the control panel. If the operation is successfully completed, the green LED lights momentarily and a "happy tune" sounds. If the operation fails or cannot be completed, for example, when the system is "Not Ready", the red LED lights steadily and a "sad tune" sounds. Buzzer Indication LED Indication Panel Response Happy (success) tune Sad (failure) tune None Momentary GREEN Success: Operation is successfully completed Momentary RED Fail: Operation failed or invalid key press None No communication: Control panel does not respond. Arming Indications The table below lists the Arming indication keys and their definition. Icon/Key Indications Arming Indication ARM AWAY 10 D-303169 KP-160 PG2 User’s Guide Icon/Key Indications Arming Indication ARM HOME DISARM EXIT DELAY Each icon appears one after the other ENTRY DELAY The "Present Prox Tag" icon and DISARM key blink simultaneously If Partition is enabled, the arming indication of the first partition is displayed concurrently with the corresponding first partition key LED , then the second partition indication is displayed concurrently with the second partition key LED and then the third partition indication is similarly displayed. General Indications The Ready/Not Ready, Alarm Memory, Trouble and Low Battery indications are provided via the indications in the following table: Number Indication [1] What it Means Instructs the user to display the RFID proximity tag in order to initiate a command. Volume control mode. System is NOT READY; one of the zones is not secured. You cannot arm the system before the zone is secured or bypassed. System is READY but one or more zones are bypassed. No indication System is READY and all zones are secured. Bypassed ( ) or Open ( ) Zone number Selected PGM or X-10 unit number. D-303169 KP-160 PG2 User’s Guide Volume level 11 Number Indication [1] What it Means PGM/X-10 control mode. System is armed in LATCHKEY mode. Exit beeps are shut off. This mode disables when the exit delay is over. [2] System is armed in the INSTANT mode. A message is waiting in the system. The control panel is presently in "INSTALLER MODE" or "USER SETTINGS". Memory / Alarm in partition or system. The partition / system has an active trouble status that needs to be reviewed and cleared. [3] AC failure. Communication failure: KP-160 PG2 is out of range of the control panel or did not get an acknowledge signal of a command from the control panel. Indicates that the KP-160 PG2 device's battery is low and must be replaced (see section 2.1). [1] The key indication is displayed after the first red LED blinks indicating the status request. [2] Operates only during Exit Delay. [3] See respective sections in the control panel's User and Installer's Guides. [4] If there is more than one status indication at a single time, the keys are displayed simultaneously. Zone Status Indications To view the zone numbers of enrolled detectors that are in NOT READY ( ) or BYPASSED state ( ), repeatedly press the key. Upon each press of the key, the next zone number appears on the Zone # display (marked "4" in the "Icon and Key Indications" Figure). To view the zone numbers that are assigned to a Partition, press the desired Partition 12 D-303169 KP-160 PG2 User’s Guide / ) followed by the key. Upon each press of the key, the number ( next zone number assigned to the pressed Partition number appears on the Zone # display. D-303169 KP-160 PG2 User’s Guide 13 Notes: A zone which is BYPASSED and NOT READY is shown as BYPASSED ( ). When "00" appears on the Zone # display, this indicates a NOT READY state in the alarm system that is not related to any detector, for example, "tamper open" in a keypad or control panel. If all zones are READY and "not bypassed", the button is disabled. 3 .4 Bypa ssing Z one s A zone can by bypassed by pressing the key until the zone number is shown on the zone # display (marked "4" in the "Icon and Key Indications" Figure) followed by the key. Note: Zone bypassing on the KP-160 PG2 unit can be operated only if Bypass was enabled via the control panel (see PowerMaster Installer Guide, section 3.5.2 "Configuring Arming/Disarming and Exit/Entry Procedures"). 3 .5 Cont rolling H om e Aut om a t ion De vic e s To configure the PGM and X-10 output functions, see the corresponding sections of the control panel’s Installer Guide (“OUTPUTS” menu) and User Guide (“SCHEDULER” menu). Step X-10 device ON PGM device ON X-10 or PGM device OFF X-10 or PGM device TOGGLE [PGM P0 to P9] or [X-10 01 to 99] [PGM P0 to P9] or [X-10 01 to 99] (~2sec) … [P0 to P9] … [00 to 99] Note: Long press (more than 2 sec.) of the button initiates the X-10 function and the PGM/X-10 display (marked "4" in the "Icon and Key Indications" Figure) will read "01". Short press of the with the 14 button initiates the PGM function and the PGM/X-10 display will read "P0" key. This number is incremented by 1 upon each press of the key. D-303169 KP-160 PG2 User’s Guide 3 .6 Ot he r Func t ions Output Function Actions AUX Function Response Enrollment: Long key press (more than 5 sec.) until green LED lights and then release key. Back to Factory: Long key press (more than 7 sec.) to reset the KP-160 PG2 device to factory default settings. Cancels current operation: Short key press Volume control Changes the volume level upon each key press. Volume level alternates between 1, 2, 3, 0 Mute exit beeps Mutes the exit beeps; small circle key will appear above the key. Press button again to cancel mute. Note: Operates only per Exit Delay duration. Upon next Exit Delay, the exit beeps will not be muted. APPEN DI X A: SPECI FI CAT I ON S Frequency Band (MHz) Europe and rest of world: 433-434, 868-869 USA: 912-919 Communication Protocol PowerG Battery type Four 1.5V AA Alkaline batteries Battery Life Expectancy 4 years (for typical use). Power source (optional) 5-12VDC Back light Blue/white or black/white Operating Temperature 0C to 55C (32F to 131F) Dimensions (WxLxD) 150x100x20mm (5-7/8 x 3-7/8 x 13/16 in) Weight (including battery and bracket) 379 g (13 oz). Mounting Wall-mounted or portable Color Black or White-Silver Compliance with Standards Europe: EN 300220-1, EN 300220-2, EN300330, EN301489, EN60950, EN50131-1, EN50131-3, EN50131-6. USA: CFR 47 part 15 Canada: RSS 210 RFID Tags: ISO-18000-2 (125 kHz) D-303169 KP-160 PG2 User’s Guide 15 APPEN DI X B: COM PLI AN CE WI T H ST AN DARDS This device complies with FCC Rules Part 15 and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. WARNING! To comply with FCC and IC RF exposure compliance requirements, the mobile version of device should be located at a distance of at least 20 cm from all persons during normal operation. The antennas used for this product must not be co-located or operated in conjunction with any other antenna or transmitter. The portable device version complies with FCC and IC RF radiation exposure limits set forth for an uncontrolled environment. The digital circuit of this device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures: – Re-orient or re-locate the receiving antenna. – Increase the distance between the device and the receiver. – Connect the device to an outlet on a circuit different from the one which supplies power to the receiver. – Consult the dealer or an experienced radio/TV technician. Changes or modifications not expressly approved by Visonic Ltd. could void the user's authority to operate the equipment. W.E.E.E. Product Recycling Declaration For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not returning it for repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste. Directive 2002/96/EC Waste Electrical and Electronic Equipment. 16 D-303169 KP-160 PG2 User’s Guide The technical documentation as required by the European Conformity Assessment procedure is kept at: UNIT 6 MADINGLEY COURT CHIPPENHAM DRIVE KINGSTON MILTON KEYNES MK10 0BZ. Telephone number: 0870 7300800, Fax number: 0870 7300801 D-303169 KP-160 PG2 User’s Guide D-303169 KP-160 PG2 User’s Guide Rev 3, 9/11 17
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res Author : marina Create Date : 2011:09:21 09:33:33+03:00 Modify Date : 2011:09:21 09:34:23+03:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 10.0.0 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2011:09:21 09:34:23+03:00 Format : application/pdf Title : Microsoft Word - User_manual_22015.doc Creator : marina Document ID : uuid:c9b0e4e5-7d79-4bcf-a620-08bf093a5493 Instance ID : uuid:1120b73f-b3ba-46cd-8b23-6f4e2f22b219 Page Count : 17EXIF Metadata provided by EXIF.tools