Visonic MCS710 Wireless Siren User Manual

Visonic Inc. Wireless Siren

User Manual

Download: Visonic MCS710 Wireless Siren User Manual
Mirror Download [FCC.gov]Visonic MCS710 Wireless Siren User Manual
Document ID716667
Application IDErLu3yGq3C7qChDPHQ+nXg==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize10.2kB (127498 bits)
Date Submitted2006-10-17 00:00:00
Date Available2006-10-17 00:00:00
Creation Date2006-10-08 14:54:41
Producing SoftwareAcrobat Distiller 4.05 for Windows
Document Lastmod2006-10-08 14:54:41
Document TitleUser Manual

MCSMCS-710
Installation Instructions
Fully Wireless Siren
1. INTRODUCTION
The MCS-710 is an indoor or outdoor fully wireless siren,
designed for installation in areas in which wiring action is difficult
or impossible. There is no need for an external power supply. The
MCS-710 is powered by an internal non-chargeable battery.
The siren communicates with the PowerMax+ wireless alarm
control system. When an identified activation command is received
from the PowerMax+, the siren activates its sounder, activates its
flash lights and acknowledges its activation to the PowerMax+.
The MCS-710 and the alarm control system should be located in
the same house.
MCS-710 Features
•
•
Designed for indoor or outdoor use
The siren has double plastic cover for extra protection against
rain and sun.
Distinguishable siren fire and burglar alarms
Fire alarm: Alternating on/off alarm sound.
Burglary alarm: Continuous high/low tone sweep.
Figure 1 - External View
•
•
Note: The siren is activated for a predefined "Bell Time" (refer to
PowerMax+ installer guide, par. 4.4) according to local authorities
requirements. After this period, the siren sound stops.
•
Squawk indications
High, mid or low siren squawk (beep) sounds can be used to
indicate PowerMax+ arming (1 squawk) and disarming (2
squawks) by a keyfob (see PowerMax+ user's guide par. 7.13).
•
Flash lights
The siren includes 6 flash lights that are activated as follows:
A. When an identified activation command is received from
the PowerMax+, the siren starts sounding for a
predetermined time (set by the PowerMax+ "4. DEFINE
PANEL", "04: BELL TIME" menu). (The siren sound can
be stopped by PowerMax+ disarming). After the siren
sounding period (if the PowerMax+ is not disarmed) the
siren lights flash once every 1 second (0.1 second ON,
0.9 second OFF) for a period of 20 minutes, or until the
PowerMax+ is disarmed.
B. When the battery voltage is low, the lights flash once every
5 seconds (for low voltage indication).
C. When there is no communication between the siren and the
PowerMax+, the lights flash once every 5 seconds, for
communication failure indication.
•
Triple Tamper protection
3 tamper switches are included; one on side cover, second touching
the mounting surface and third attached to the closure screw.
•
Non-rechargeable 3.6V Lithum battery
When the battery voltage is low, low battery message is sent
to the PowerMax+. After the low voltage message delivery, at
least 2 siren alarms will be possible before the siren will be
totally inactive.
2-way full supervision
The siren is fully supervised, 2-way communication device. It
includes a receiver, to receive activation commands from the
alarm system, and a transmitter, to periodically transmit its
status signal to the alarm system.
The transmitted signal strength can be measured during the
installation (refer to PowerMax+ installer guide, paragraph 5.2
– Diagnostic Test).
Self-test feature
Upon pressing the MCS-710 self test switch for 3 seconds,
the siren functional check is performed (low level sounds and
flash lights indicate that that siren is serviceable).
Remote commander
Emergency pendant
transmitter
Door or window
open/close detector
MCS-710
Universal perimeter
protection detector
Smoke detector
Motion detector
Hard wired detector
Figure 2- Integration with the Alarm System
Note: When the PowerMax+ is removed or its power is switched
off for a long period, the siren internal battery should be removed
to preserve battery life.
2. SPECIFICATIONS
Siren Type: Piezo, 100dB min. SPL @ 1m, 1.8-2.3 kHz, sweep
frequency 7Hz
Internal Battery: 3.6V non-rechargeable Lithum battery, EEMB
type ER34615M
Battery life expectancy: 3 years (for typical use)
Operating Frequency (MHz): 315, 433.92, 868.95, or other
frequency according to the requirement in the country of use.
DE5421
Receiver and Transmitter ID Type: 24-bit
Flash Lights Duration: 100ms ON, 900ms OFF
Dimensions (LxWxD): 30 x 19 x 7 cm (11-13/16 x 7-1/2 x 2-3/4 in)
Weight: 982g (34.6 oz.)
Operating Temperature: -30°C to 70°C (-22°F to 158°F)
Compliance with Standards: EN 50131-1 Grade 2 Class II
3. INSTALLATION,
INSTALLATION, TESTING AND ENROLLING
BATTERY
Battery
Locat e the batt ery,
tighten it with tightening
strap and connect the
b a t t e r y c o n n e c t o r.
BATTERY &
BATTERY
TIGHTENING
STRAP
Remove screw
and remove cover
Mark and drill 4 holes (as desired) in
mounting surface, fasten the siren to
the surface with four 6 cm screws.
SELF TEST
ENROLLING
Press SF TST (Self-Test) switch
for 5 seconds minimum. Verify
that the siren sounds (low level
sound) and that the lights flash.
Perform enrolling procedure as
described in PowerMax+ installer guide
(par. 4.2). When TRANSMIT NOW is
displayed, press the siren SF TST (Self
Test) switch 2-3 seconds and release.
PowerMax+ should indicate a successfull enrolling.
Press the SF TST button again if needed.
Figure 3 – Installation, Testing and Enrolling
Notes
a. Pressing the Self-Test switch for 3 seconds is used for testing the siren (by using low level sound) and its flash light.
b. Pressing the Self-Test switch momentarily is used to enroll the siren in the PowerMax+ memory (The PowerMax+ must
recognize the siren unique identification code for command delivery and supervision).
c. After the enrolling, close the siren cover and perform DIAGNOSTIC TEST, as described in PowerMax+ installer guide par. 5.2.
d. Enrolling cancellation, if required, is described in the PowerMax+ Installer Guide.
e. Before removing the siren form the mounting surface:
1. Perform deleting the siren enrolling in the control panel.
2. Enter Installer Mode and enter Installer Code and then you can remove the siren without activating the siren.
Interference Prevention
This device complies with FCC Rules Part 15. Operation is subject to two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference that may be received or that may cause undesired operation.
The digital circuit of this device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception. However, there is no
guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be verified by turning the device off and on,
the user is encouraged to eliminate the interference by one or more of the following measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
– Connect the device to an outlet on a circuit different from the one which supplies power to the receiver.
– Consult the dealer or an experienced radio/TV technician.
Changes or modifications not expressly approved by Visonic Ltd. could void the user's authority to operate the equipment.
WARRANTY
Visonic Ltd. and/or its subsidiaries and its affiliates ("the Manufacturer") warrants its products hereinafter
referred to as "the Product" or "Products" to be in conformance with its own plans and specifications and to
be free of defects in materials and workmanship under normal use and service for a period of twelve
months from the date of shipment by the Manufacturer. The Manufacturer's obligations shall be limited
within the warranty period, at its option, to repair or replace the product or any part thereof. The
Manufacturer shall not be responsible for dismantling and/or reinstallation charges. To exercise the warranty
the product must be returned to the Manufacturer freight prepaid and insured.
This warranty does not apply in the following cases: improper installation, misuse, failure to follow
installation and operating instructions, alteration, abuse, accident or tampering, and repair by anyone other
than the Manufacturer.
This warranty is exclusive and expressly in lieu of all other warranties, obligations or liabilities, whether
written, oral, express or implied, including any warranty of merchantability or fitness for a particular purpose,
or otherwise. In no case shall the Manufacturer be liable to anyone for any consequential or incidental
damages for breach of this warranty or any other warranties whatsoever, as aforesaid.
This warranty shall not be modified, varied or extended, and the Manufacturer does not authorize any
person to act on its behalf in the modification, variation or extension of this warranty. This warranty shall
apply to the Product only. All products, accessories or attachments of others used in conjunction with the
Product, including batteries, shall be covered solely by their own warranty, if any. The Manufacturer shall
not be liable for any damage or loss whatsoever, whether directly, indirectly, incidentally, consequentially
or otherwise, caused by the malfunction of the Product due to products, accessories, or attachments of
others, including batteries, used in conjunction with the Products.
The Manufacturer does not represent that its Product may not be compromised and/or circumvented, or that
the Product will prevent any death, personal and/or bodily injury and/or damage to property resulting from
burglary, robbery, fire or otherwise, or that the Product will in all cases provide adequate warning or
protection. User understands that a properly installed and maintained alarm may only reduce the risk of
events such as burglary, robbery, and fire without warning, but it is not insurance or a guarantee that such
will not occur or that there will be no death, personal damage and/or damage to property as a result.
The Manufacturer shall have no liability for any death, personal and/or bodily injury and/or damage
to property or other loss whether direct, indirect, incidental, consequential or otherwise, based on a
claim that the Product failed to function. However, if the Manufacturer is held liable, whether directly or
indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of cause or
origin, the Manufacturer's maximum liability shall not in any case exceed the purchase price of the Product,
which shall be fixed as liquidated damages and not as a penalty, and shall be the complete and exclusive
remedy against the Manufacturer.
Warning: The user should follow the installation and operation instructions and among other things test the
Product and the whole system at least once a week. For various reasons, including, but not limited to,
changes in environmental conditions, electric or electronic disruptions and tampering, the Product may not
perform as expected. The user is advised to take all necessary precautions for his /her safety and the
protection of his/her property.
6/91
W.E.E.E. Product Recycling Declaration
For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not
returning it for repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste.
Directive 2002/96/EC Waste Electrical and Electronic Equipment.
VISONIC LTD. (ISRAEL): P.O.B 22020 TEL-AVIV 61220 ISRAEL. PHONE: (972-3) 645-6789, FAX: (972-3) 645-6788
VISONIC INC. (U.S.A.): 65 WEST DUDLEY TOWN ROAD, BLOOMFIELD CT. 06002-1376. PHONE: (860) 243-0833, (800) 223-0020 FAX: (860) 242-8094
VISONIC LTD. (UK): FRASER ROAD, PRIORY BUSINESS PARK, BEDFORD MK44 3WH. PHONE: (0870) 7300800 FAX: (0870) 7300801
INTERNET: www.visonic.com
VISONIC LTD. 2006 MCS-710, DE5421- (REV. 2, 08/06)
DE5421

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Create Date                     : 2006:10:08 14:54:41
Producer                        : Acrobat Distiller 4.05 for Windows
Modify Date                     : 2006:10:08 14:54:41+02:00
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: GSAMCS710