 D-305291 MCT-340 SMA Installation Instructions  1  MCT-340 SMA Wireless Contact Sensor  Installation Instructions  1. INTRODUCTION  The MCT-340 is a fully supervised, wireless magnetic contact sensor, for use  with  iControl  H.A.  1.2  control  panels.  The  sensor  includes  a  built-in reed switch (that opens upon removal of a magnet placed near it).  The MCT-340 tamper switch is activated when the cover is removed. A  periodic  supervision  message  is  transmitted  automatically.  The  target receiver  is  thus  informed,  at  regular  intervals,  of  the  unit’s  active participation in the system. Operating power is obtained from an on-board 3 V Lithium battery. When the  battery  voltage  is  low,  a  “low  battery”  message  will  be  sent  to  the receiver 30 days before expiration of battery life. PairingLEDMagnet Fig. 1 –  External View  2. SPECIFICATIONS WIRELESS Frequency: 2.4 GHz as per IEEE 802.15.4 Tamper Alert: Reported when a tamper event occurs and in any subsequent message, until the tamper switch is restored. Supervision Message: Signaling at 27-minute intervals. Transmission Range in Open Area: Up to 280 meters (iControl panel) ELECTRICAL Internal Battery: 3V Lithium battery, type CR2032. Use Varta only. Nominal Battery Capacity: 230 mAh Battery Life Expectancy: 3 years (for typical use). Note: Inability to connect with wireless network, or wireless link quality no higher than 20% may significantly reduce the expected battery life. Battery Power Test: Performed immediately upon battery insertion and periodically every several hours. Battery Supervision: Automatic transmission of battery condition data as part of any status report. ENVIRONMENTAL  Operating Temperature: 0°C to 55°C (32°F to 131°F). Dimensions: 66 x 25 x 10 mm (2-9/16 x 1 x 6/16 in.) Weight (including battery): 15g (0.5 oz)   3. ACTIVATING THE SENSOR To activate, pull the strip (from either side) that protrudes from the back of the sensor. Activationstrip Fig. 2 – Activation Strip   4. PAIRING/DEFAULTING THE SENSOR To pair the sensor to the control panel, you must set it to pairing mode. First set the panel to pairing mode and then the sensor. 1.  Press and hold down the sensor’s tamper switch (see Figure 4-4). 2.  Insert the battery into the sensor (see Figure 4-4). 3.  Release the  tamper  switch  within  4 seconds (the  LED blinks 3  times every 5 seconds). 4.  Complete the  pairing procedure  on the control  panel (see  the pairing instructions in the control panel’s installation guide).   5. INSTALLATION CAUTION:  This equipment shall  be  installed  by Service  Personnel  in non-hazardous indoor locations only. 5.1 Mounting NOTE: It is highly recommended to attach the  transmitter to the top of the door/window on the fixed frame and the magnet to the movable part (door or window). Make sure that the magnet is located not more than 6 mm (0.25 in.) from the transmitter’s marked side.  The transmitter should be mounted on the fixed surface and the magnet on the moving surface (see Figure 3). A1 1. Peel away the release liners from the two strips of double-sided adhesive tape and attach to the device and magnet. A. Double-sided adhesive tape  2 2. Align the device with the magnet according to the location marks and fasten the device and magnet to the mounting surface. The transmitter should be mounted on the fixed surface and magnet on the moving surface. Fig. 3 – Mounting 5.2 Battery Replacement 1 2
 2  D-305291 MCT-340 SMA Installation Instructions  3 4Tamperswitch Fig. 4 – Battery Replacement 1. Insert a “quarter” coin in the slot as shown in the drawing and push downward firmly into the slot. 2. Twist to remove the cover. 3. Remove the old battery using a 3 mm flat-edged screwdriver. 4. Insert the battery at an angle, as shown in the drawing, while observing battery polarity. Note: The required battery is CR2032 Lithium 3V, manufactured by VARTA or another UL recognized manufacturer, purchased from a Visonic-approved supplier. 6. TESTING THE SENSOR Close the door or window, thus restoring it to the undisturbed state.  7. TROUBLESHOOTING If  you  encounter  one  of  the  following  problems  with  the  MCT-340  SMA, perform the suggested remedy: Problem Remedy Attempt to pair the sensor is unsuccessful. Make sure that the sensor has been defaulted and is set to pairing mode (see section 4). Make sure that the iControl panel supports the H.A 1.2. The sensor and the panel do not communicate. Perform the signal strength testing procedure described in the control panel installation manual. Make sure that the signal is sufficient. If necessary, replace the sensor’s battery.  Problem Remedy The sensor sends a Low Battery indication. To ensure continuous proper operation, replace the battery within two weeks of the first Low Battery indication. Panel does not arm because of an unrecognized sensor malfunction Consult with your installer or system provider before you disable a zone. Disable the detector zone (see the control panel user manual). Note that disabling a sensor zone lowers the overall security level of your system. 8. COMPLIANCE WITH STANDARDS FCC This device complies with Part 15 of the FCC Rules and RSS-210 of Industry and Science Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.     FCC ID: WP3MCT340SMA IC: 1467CMCT340SMA   USA/CANADA Complies with: USA: CFR 47 part 15, Canada: RSS 210. ANSI/UL 634, ULC – S306 FCC Compliance Statement This device has been tested and found to comply with the limits for a Class B digital device, pursuant  to  Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide reasonable  protection  against  harmful  interference  in  residential  installations.  This equipment  generates  uses  and  can  radiate  radio  frequency  energy  and,  if  not installed  and  used  in  accordance  with  the  instructions,  may  cause  harmful interference to radio and television reception. However,  there  is  no  guarantee  that  interference  will  not  occur  in  a  particular installation.  If  this  device  does  cause  such  interference,  which  can  be  verified  by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures: – Re-orient or re-locate the receiving antenna. – Increase the distance between the device and the receiver. –  Connect  the  device  to  an  outlet  on  a  circuit  different  from  the  one  that  supplies power to the receiver. – Consult the dealer or an experienced radio/TV technician. WARNING!  Changes  or  modifications  to  this  unit  not  expressly  approved  by  the party  responsible  for  compliance  could  void  the  user’s  authority  to  operate  the equipment. Reed Switch Positions Wood Supports Iron YxYZYXXZ Figure 5 - Range Coverage Directions Opening  Closing  Direction  Opening  Closing >10 mm  <8 mm  X  >10 mm  <9 mm >25 mm  <21 mm  Y  >12 mm  <10 mm >30 mm  <25 mm  Z  >12 mm  <10 mm  9. PRODUCT LIMITATIONS Visonic  Ltd.  wireless  systems  are  very  reliable  and  are  tested  to  high standards.  However,  due  to  low  transmitting  power  and  limited  range (required  by  FCC  and  other  regulatory  authorities),  there  are  some limitations to be considered: A. Receivers may  be  blocked  by radio  signals  occurring  on  or near their operating frequencies, regardless of the digital code used. B. A receiver responds only to one transmitted signal at a time. C.  Wireless  devices  should  be  tested  regularly  to  determine  whether there are sources of interference and to protect against faults. The user is cautioned that  changes or modifications to the unit, not expressly  approved  by  Visonic  Ltd.,  could  void  the  user’s  FCC  or other authority to operate the equipment.     W.E.E.E. Product Recycling Declaration For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not returning it for repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste. Directive 2002/96/EC Waste Electrical and Electronic Equipment.   EMAIL: info@visonic.com INTERNET: www.visonic.com VISONIC LTD. 2014       MCT-340 SMA       D-305291   (Rev 0, 5/14)       Please refer to the separate Warranty statement

Navigation menu