Von Duprin QEL Conversion Kit For 98/99 Series 110745
User Manual: Von Duprin QEL Conversion Kit for 98/99 Series Installation Instructions
Open the PDF directly: View PDF .
Page Count: 8
Download | ![]() |
Open PDF In Browser | View PDF |
QEL 33A/35A, 98/99 Series *24908386* 24908386 Conversion Kit 1. 2. 3. 4. 5. Installation Instructions This kit converts all 33/35A and 98/99 series mechanical exit devices to quiet electric latch (QEL) retraction devices. This kit can also be used for motor replacement on existing QEL devices. Install according to instructions or device will not function and panic or fire label will be void. The QEL wiring must be attached to the fire alarm system if installed on fire exit hardware. If existing device is fire rated or less dogging a QEL baseplate conversion kit is required. Parts 3 Remove Exit Device from Door Device and trim must be held securely while screws are being removed, to prevent dropping to the floor ! a QEL c b Unplug cable, HD-QEL (Hex Dogging QEL) WARNING If existing exit device is fire rated, do not install HD-QEL (hex dogging) type motor. Doing so will void fire rating. 1 Disconnect Power d 4 Remove Mechanism Case To avoid risk of shock, disconnect AC power from power supply before proceeding with this conversion. If using 900-BB Battery Backup option, unplug all four wires from battery terminals. 2 33a/35a c Detach Vertical Rods if present Refer to device instructions as needed. d b Keep all parts a OR 98/99 b a 5 Prepare baseplate for new motor. Find your existing application below (on page 2 or 3) and follow steps. FIRE OR LESS DOGGING DEVICE (Applies to exit devices built after October 2014. Baseplate conversion kit required for earlier devices.) QEL DEVICE (built prior to December 2014) 1. Remove existing QEL motor 1. Remove pushpad from baseplate. Keep pushbar b a c 2. 2. Install connector and pin. Verify pin is snapped in place on other side of action rod. Pin should be inserted from side that will be up when device is mounted on door. b a 2 Discard old QEL motor assembly. 5 Continued QEL DEVICE (built after December 2014) PANIC DEVICE (with dogging assembly) 1. 1. Remove two screws from dogging assembly. If riveted see below. 2. Drill or use center punch on two rivet heads until rivets can be removed from baseplate. Remove existing QEL motor. a b 2. Discard old QEL motor assembly. 1/4” or 5/16” or Note: Do not drill through baseplate. Rivet may tend to spin with drill bit. 3. 3 Remove and discard dogging assembly. 6 8 Install New QEL Motor Assembly 8a Prepare dogging cover for HD dogging key (if applicablle and only on panic devices). Locate and drill hole 1/4” New QEL motor assembly Center of Cover a Deburr edge of hole 1 1/2” 8b Install dogging cover 9 Drill Wire Access Hole (if required) b 7 Install Mechanism Case ⁵⁄₁₆" 33/35 b a c d Drill ⁵⁄₈" dia. access hole through device side of door. OR 98/99 a b 4 10 Attach Exit Device to Door d a b For more detailed installation instructions for specific Exit Devices, visit the Support area of the Allegion website at www.allegion.com/us 11 Confirm Equipment Compatibility The QEL is compatible with the following equipment (refer to individual instructions as needed): • PS900-SERIES Power Supplies - PS902, PS904, PS906, PS914 • 900-SERIES Option Boards - 900-2RS, 900-4R, 900-4RL, 900-2Q • PS873 Power Supply Plus 871-2, 871-2Q, 873-4TD/AO Option Boards 12 Route Two Wires from QEL Exit Device to Power Supply QEL Electrical Load Voltage: 24 VDC Current: 1.0 A inrush (0.5 sec) 0.14 A holding PS900-Series power supply with 900-Series option board(s) installed QEL device used with EPT, Door Loop, or Electric Hinge/Pivot Distance (one way) Wire Gauge 200’ 18AWG 320’ 16AWG 500’ 14AWG 800’ 12AWG QEL Exit Device EPT shown. A door loop or electric hinge/pivot may also be used. 5 Note: Power wires to QEL are not polarized. 13 b Review Available 900 series Option Board Mounting Locations (Gray) Plug Option Board Cable into any Available Option Connector PS902 1 Board Option 1 a Install 900-2Rs, 4Rl, or 4R Option Board(s) into Power Supply 1 PS904, 914 2 Boards Option 2 Option 1 PS902 Option 3 Option 2 Option 1 1 PS906 3 Boards PS904 PS914 1 2 c Secure Board(s) with Screws Notes: 1. 24VDC output setting required when QEL device connected 2. If installing board in location 2 or 3, rotate board 180˚ PS906 1 3. The QEL is compatible with an existing 900-2Q board if currently installed. 2 4. Latchbolt retraction of (2) sequenced QEL’s requires more than 1 second to complete. 5. When powering multiple components, verify that the amperage requirements of all components combined does not exceed the power supply output rating. 3 14 Connect Input and Output Wires to Option Board (2RS Shown) Individual Mode - Typical Wiring Sequential Mode - Typical Wiring PS900 Series 120/240 VAC (PS900 Series only) 50/60Hz 2RS Input I1 will activate both outputs SC I1 01 I2 02 GND EPT-2/10 Note: Fail secure output only allowed if approved by Authority Having Jurisdiction Access Control for Devices 1&2 PS900 Series 120/240 VAC 50/60Hz 2RS SC I1 01 I2 02 GND EPT-2/10 Access Control for Device 2 EPT-2/10 Input I1 will activate output 1 Input I2 will activate output 2 QEL Device 2 EPT-2/10 QEL Device 1 QEL Device 2 Access Control for Device 1 6 QEL Device 1 15 Check Operation A. Activate each input and verify all QEL devices operate properly. B. If any device does not operate properly, see step 16 for troubleshooting. 16 If Necessary, Troubleshoot Operation (LED is only visible with the mechanism cover removed) Power at the QEL 24VDC QEL Response LED - Solid green Latchbolt - retracted Operation normal, latch retracted immediately LED - Solid red after latchbolt attempts to retract multiple times Verify mechanical adjustment (on vertical rod or mortise lock devices if used). Remove and reapply input voltage to reset this condition.* LED - Flashing green/red Latchbolt - not retracted 24VDC low LED - Flashing green Latchbolt - retracted 29VDC or greater 13VDC or lower Condition/Solution Latchbolt cannot fully retract mechanically See Check Mechanical Operation on page 8 as needed.** Excessive tamper (while power applied, the pushpad was pulled out at least 3 time) Wait 15 seconds and latchbolt will retract again OR remove and reapply power to clear condition Voltage low during latchbolt retraction (latchbolt retracts at reduced force) Wire length is too long, wire gauge is too small or power supply has poor regulation Input voltage is too high for proper operation Wrong power supply, power supply defective. Input voltage is too low for proper operation LED- Flashing red Latchbolt - will not retract 0VDC LED - off Latchbolt - not retracted 0VDC LED - off Latchbolt - retracted Wrong power supply, power supply defective or not set to the proper output voltage. To set, remove AC power from power supply, change power supply setting from 12 to 24VDC, then reapply AC power and verify proper operation. No input voltage Problem with the power supply, control switch or wiring No input voltage Mechanical dogging is engaged *For information about adjusting exit devices, you can find their installation instructions in the support area at www.allegion.com/us or call Technical Services at 1-877-671-7011 LED on Device 7 17 Check Mechanical Operation 33A/3527A 98/9927 98/9947WDC 33/3549A 98/9949 33A/3547A 98/9947 98/9957 33/3550A-WDC 98/9949WDC 98/9975 98/9950WDC 1. Make sure device is not dogged for SD-QEL / HD-QEL. 1. Make sure device is not dogged for SD-QEL/HD-QEL. 2. Depress pushbar and make sure latch bolt retracts and extends fully (see Figure 1). 2. Depress pushbar. Door should begin to open with pushbar depressed halfway. 3. If latch bolt does not retract or extend fully, adjustments may be required per the device installation instructions. 3. Close door. Top latch should be secure. If two point latch, bottom latch should be secure as well. 33A/3527A, 98/9927, 98/9957 Latch bolt deadlocked (will not push in) Latch bolt Release stays retracted trigger extended 4. If device does not function as described in steps 2 and 3, adjustments may be required per the device installation instructions. Any HD Device 1. Fully depress pushbar. with door closed with door open ³⁄₁₆" 33A/3547A, 98/9947, 98/9947WDC Latch bolt deadlocked (will not push in) Flush within ¹⁄₁₆" 2. Insert hex dogging key and turn clockwise. 3. Release pushbar and verify latchbolt remains retracted. 4. Fully depress pushbar. 5. Insert hex dogging key and turn counter clockwise. 6. Release pushbar and verify latchbolt extends fully. ⁵⁄₈" Latch bolt extended Latch bolt retracted 98/9975 Latch bolt extended ³⁄₄" Latch bolt retracted Flush within ¹⁄₁₆" Figure 1 Customer Service 1-877-671-7011 www.allegion.com/us © Allegion 2015 Printed in U.S.A. 24908386 Rev. 11/15-b
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Create Date : 2015:11:16 14:21:47-05:00 Metadata Date : 2015:11:16 14:22-05:00 Modify Date : 2015:11:16 14:22-05:00 Creator Tool : Adobe InDesign CS6 (Windows) Instance ID : uuid:95e0d141-cb45-468c-a104-a56b3c6f858d Original Document ID : xmp.did:516915126ECCE1118A0D8AD340C27D6B Document ID : xmp.id:5F05382D968CE511B36D98872D6FECBF Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:5E05382D968CE511B36D98872D6FECBF Derived From Document ID : xmp.did:FC83BB827F8CE511B36D98872D6FECBF Derived From Original Document ID: xmp.did:516915126ECCE1118A0D8AD340C27D6B Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2015:11:16 14:21:47-05:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 8 Creator : Adobe InDesign CS6 (Windows)EXIF Metadata provided by EXIF.tools