INSTALLATION INSTRUCTIONS
ZW1P
Wireless Lighting Control
Plug-in Lamp
Dimming Module
1. Plug the ZW1P Lamp Dimming Module into a 120VAC,60HZ outlet.
2. Plug the lamp into the ZW1P Lamp Dimming Module. Make sure the
lamp to be controlled does not exceed 300 Watts.(Not for use with
fluorescent lights, motor loads, or magnetic or electronic transformers.)
3. Turn the knob or switch on the lamp to the ON position.
2 3
Manual Control
INSTALLATION
SPECIFICATIONS
Voltage................................................................................ 120VAC, 60Hz
Maximum Load requirements:
Incandescent......................................................................................300W
Resistive...........................................................................................1800W
Frequency................................................................................ 908.42 MHz
Operating Temperature............................................................... 32-104° F
Range.................................................................Up to 100 feet line of sight
between the Wireless Controller and the closest Z-Wave receiver module.
The following Advanced Operation parameters require that you have an
advanced controller. However, basic remotes do not have this capability.
All On/All Off
Depending upon your primary controller, the ZW1P dimming module can
be set to respond to ALL ON and ALL OFF commands in up to four different
ways. Some controllers may not be able to change the response from its
default setting. Please refer to your controller’s instructions for information
on whether or not it supports the configuration function and if so, how to
change this setting.
FEATURES
The four possible responses are:
DESCRIPTION
This lamp dimming module is a Z-Wave enabled device and is fully comp-atible with any Z-Wave enabled network. Z-Wave enabled devices display-ing the Z-Wave logo can also be used with it regardless of the manufacturer.
In a Z-Wave network, each device is designed to act as a wireless repeater.
Repeaters will retransmit the RF signal from one device to another until the
intended device is reached. This ensures that the signal is received by its
intended destination by routing the signal around obstacles and radio dead
spots.
OPERATIONS
Program Button
Z-Wave outlet
If you are unsure or uncomfortable about performing the installation,
please consult a qualified electrician.
-01-
- It will respond to ALL-ON and the ALL-OFF command (default).
- It will not respond to ALL-ON or ALL-OFF commands.
- It will respond to the ALL-OFF command but will not respond to the ALL-ON
command.
- It will respond to the ALL-ON command but will not respond to the ALL-OFF
command
WARNINGS AND CAUTIONS
To be installed and/or used in accordance with approprite electrical codes
and regulations. Exercise extreme caution when using Z-Wave devices to
control appliances. Operation of the Z-Wave device may be in a different
room than the controlled appliance, also an unintentional activation may
occur if the wrong button on the remote is pressed. Z-Wave devices may
automatically be powered on due to timed event programming.Depending
upon the appliance, these unattended or unintentional operation could
possibly result in a hazardous condition.
1.To manually turn ON the ZW1P Lamp Dimming Module, press and release
the program button.The blue indicator LED will turn ON, and the lamp plugged
into the ZW1P Lamp Dimming Module will also turn ON.
2.To manually turn OFF the ZW1P Lamp Dimming Module, simply press and
release the program button. The blue indicator will turn OFF and the lamp
plugged into the ZW1P Lamp Dimming Module will also turn OFF.
3.To manually dim the ZW1P Lamp Dimming Module, press and hold the
program button until the desired lighting level has been reached.
4. Refer to the instruction for your primary controller to access the setup
function and include or exclude devices.
ADVANCED OPERATION
Z-Wave controled AC outlet
Provides manual and remote control
Blue LED show feedback from the controller
Ease of installation(no new wiring)
Compatible with other Z-Wave enabled devices
The Front Panel Program Button on the ZW1P dimming module allows the
user to:
Blue LED indicator
WIRELESS RANGE
This device complies with the Z-Wave standard of open-air, line of sight
transmission distances of 65 feet. Actual performance in a home depends
on the numbers of walls between the remote controller and the destination
device, the type of construction and the number of Z-Wave enabled devices
installed in the control network.
Things to consider regarding RF range:
Basic Operation
The connected light can be turned ON in two ways:
1. With a Z-wave remote.
2. Manually with the program button on the Z-Wave module.
Remote Control
Z-Wave remotes provide control of an Individual device, Groups of devices
and Scenes. Please refer to your remote control's instructions for detail on
its capabilities and instructions for adding and controlling devices.
-02-
- Each wall or obstacle (i.e.:refrigerator, big screen TV, etc.)between the
remote or a Z-Wave device and the destination device will reduce the
maximum range by approximately 25-30%.
- Brick, tile or concrete walls block more of the RF signal than walls made
of wooden studs and plasterboard (drywall).
- Wall mounted Z-Wave devices installed in metal junction boxes will suffer
a significant loss of range (approximately 20%) since the metal box blocks
a large part of the RF signal.
-03-
INSTALLATION INSTRUCTIONS
Effects of Home Construction on Wireless Range Between
Z-Wave Enabled Devices.
Note: The distances shown in the table below are typical examples.Actual
performance in your home will vary .
From the Remote (or repeating Z-Wave module) to
destination device:
Type of
Construction
Number of
Walls or
Obstacles
Wood Frame with
Drywall
Brick, Tile or
Concrete
Plastic
J-Boxes*
Metal
J-Boxes
Plastic
Metal
J-Boxes* J-Boxes
0** 100’
80’
100’
80’
70’
56’
60’
48’
49’
39’
36’
29’
34’
27’
21’
17’
Restoring Factory Defaults
All Configuration Parameters can all be restored to their factory default settings
by using your primary controller to reset the device.
Troubleshooting:Verify that the lamp wattage does not exceed the 300W
rating if the module doesn’t seem to work properly. Normal operation can
be restored by remote when the load is reduced to the proper rating.
Over-Current Protection
Additional over-current protection is provided by an internal fuse which is
not user serviceable. Check your home’s circuit breakers before concluding
that the product must be replaced.
WARRANTY INFORMATION
Our company warranties its products to be free of defects in materials and
workmanship for a period of two (2) years. There are no obligations or
liabilities on the part of our company for consequential damages arising
out of or in connection with the use or performance of this product or
other indirect damages with respect to loss of property, revenue, or profit,
or cost of removal, installation or reinstallation.
Jun,2011
-04-
-05-
FCC STATEMENT
1. This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
2. Changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
FCC ID: ZZH-ZW1P
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Count                      : 3
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:aa316c9d-c9fe-489a-8da1-bb31035656c5
Producer                        : Acrobat Distiller 6.0 (Windows)
Modify Date                     : 2011:09:15 14:18:24+08:00
Create Date                     : 2011:09:15 14:18:24+08:00
Document ID                     : uuid:b74cd127-7dc7-40d0-a38f-15525de98bbe
Format                          : application/pdf
Title                           : untitled
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ZZH-ZW1P

Navigation menu