WG security WGWFCB 58 KHz Electronic Article Surveillance System User Manual Manual

WG Security Products, Inc 58 KHz Electronic Article Surveillance System Manual

Manual

            58KHz WiFi Floor Guard & Door Guard EAS Systems  (EAS5.0 ver1.6 AM board) Installation Manual     March 2015  Manual Ver. 03261501          TM
                      WG SECURITY PRODUCTS INC.  2105 S. Bascom Ave., Suite 316, Campbell, CA 95008 (USA) http://www.wgspi.com    Technical Support Contact Information North America South America Tel: 408-241-8000 Fax: 408-559-2073 Email: service@wgspi.com Rest of World Tel: +49 8654 7715-0 Fax: +49 8654 7715-29 Email: support@wgglobal.eu        WARRANTY DISCLAIMER  WG  Security  Products  Inc.  makes  no  representation  or  warranty  with  respect  to  the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Further, WG Security Products Inc. reserves the right to  revise  this  publication  and  make  changes  from  time  to  time  in  the  content  hereof without obligation of WG Security Products Inc. to notify any person of such revision or changes. CRITICAL NOTES As specified by FCC Regulations 15.21, any changes or modifications not expressly approved by the  party  responsible  for  compliance  of  this  equipment,  will  void  the  user’s  permission  and authority to operate this equipment.  This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in  accordance  with  the  instruction  manual,  may  cause  harmful  interference  to  radio communications.  Operation  of  this  equipment  in  a  residential  area  is  likely  to  cause  harmful interference in which case the user will be required to correct the interference at his own expense.
TABLE OF CONTENTS    OVERVIEW ..................................................................................................................... 1 System Overview ......................................................................................................... 1 System Configurations ................................................................................................. 2 Product Codes and Descriptions ................................................................................. 3 Specifications .............................................................................................................. 4 CONTROLLER CIRCUIT BOARD .................................................................................. 5 WiFi Main Board Connectors ....................................................................................... 5 System Configuration .................................................................................................. 6 PRE-INSTALLATION INFORMATION ............................................................................ 7 Quick Start for System Connections ............................................................................ 7 SMART POWER SUPPLY (WG SPS-24) ..................................................................... 12 Controls and Connections ......................................................................................... 12 Terminals Description ................................................................................................ 13 Main AC Input and Voltage Setup ............................................................................. 14 External Relay interface ............................................................................................. 15
 (THIS PAGE INTENTIONALLY LEFT BLANK)
WiFi Floor Guard & Door Guard EAS Systems 1 OVERVIEW   System Overview  All WIFI  EAS  Systems  utilize  a  common  controller,  differing  only  in  the  antennas  that  are used.  Pedestal  controllers  (Ad  Guard,  Ad  Guard  XL,  Premier  Guard  and  Premier  Pro)  are imbedded in the pedestal base. Door Guard and Floor Guard controllers are contained in a separate  housing.  In  either  case,  the  controller  is  comprised  of  a  main  circuit  board  for performing all the functions of transmitting, receiving and alarm notification. The power board facilitates all the antenna transmission. This manual applies to the WiFi Floor Guard and WiFi Door Guard.   Door Guard and Floor Guard Antennas These modules contain only the antennas whose operation and power are derived from the separate Control and Adaptor boxes.  WiFi Control and Adaptor Boxes The  Controller  Box contains  the WiFi  Controller  and PSU  (WG  SPS-24)  for  controlling  the antenna and processing tag data. Between the Control Box and Antenna is the Adaptor Box which ensures signal stability between the WiFi Controller and the antennas. The Control Box includes WiFi capability so that the systems can be synchronized and tuned remotely over the Internet.                                      WiFi Control Box WiFi Floor Guard WiFi Adapter Box WiFi Door Guard WiFi Controller WG SPS-24
WiFi Floor Guard & Door Guard EAS Systems 2 System Configurations  Each WiFi system is powered by its own dedicated SPS. The SPS not only provides 24vac power to the transceiver pedestal, but it includes some very important features.   Accepts a wide range of AC input voltage   Controls transmitter bursts for troubleshooting   Adjusts pedestal alarm volume   Provides alarm visual & audio indication and relay output   Provides Jammer Detection alarm and relay output   24vac power and data/control is carried by a single TX cable from the SPS to the controller. The WiFi Control Box can only be connected to only one adaptor and from that to only one antenna.                  Caution!  One  WiFi  Control  Box  can  only  be connected with one antenna and Adapter Box.
WiFi Floor Guard & Door Guard EAS Systems 3  Product Codes and Descriptions   Systems  Product Code Description Comment WG WFFG Floor Guard WiFi Transceiver, 6-foot Includes antennas, WiFi Control Box and Adaptor Box. WG WFDG Door Guard WiFi Transceiver, Gray Includes antenna, WiFi Control Box and Adaptor Box. WG WFDG-B Door Guard WiFi Transceiver, Black Includes antenna, WiFi Control Box and Adaptor Box. WG WFDG-W Door Guard WiFi Transceiver, White Includes antenna, WiFi Control Box and Adaptor Box. WG SPS-24 Smart Power Supply (24vac) Ordered separately but mounted inside the Control Box     Accessories, Spares and Options  Product Code Description Comment WG WFCB WiFi Control Box (with WG SPS-24) Included with WG WFFG and WG WFDG (N/A) Adaptor Box Included  with  WG  WFFG  and WG WFDG
WiFi Floor Guard & Door Guard EAS Systems 4 Specifications  Smart Power Supply (WG SPS-24) Electrical Primary Input (Stepdown Transformer)   100vac 10 %   110vac 10 %  120vac 10 %  220vac 10 %  240vac 10 %  Secondary Output 26Vac  5 % Rated Output Current 1.8A  Maximum Secondary Output Current 1.9 A Built-in Fuse (self-resettable) 500mA   Smart Power Supply (WG SPS-24) Mechanical   Height 80mm ( 3.15” )   Width 110mm ( 4.33” )   Thickness 140mm ( 5.5” )   Weight 3 Kg ( 6.6 lbs)  Environmental (Antenna, Control Box, Adaptor Box and Power Supply) Operating Temperature 45 C (113F) Relative Humidity 0 to 85% non-condensing  Mechanical (Antenna, Control Box and Adaptor Box) Floor Guard Antenna 59.25”L x 15.75”W (150.5cm x 40cm) Thickness 1.13” (2.9cm) Weight 33 lb. (15kg) Door Guard Antenna 59”H x 9.5”W x 1.75”D (150 x 24 x 4.4cm) Weight TBD  Control Box Dimensions TBD Weight TBD  Adaptor Box 7.75” x 7.5” x 3.5” (197 x 190 x 90cm) Weight TBD
WiFi Floor Guard & Door Guard EAS Systems 5 CONTROLLER CIRCUIT BOARD   WiFi Main Board Connectors                                           WiFi Module Alarm Connector TX Connector RX Connector
WiFi Floor Guard & Door Guard EAS Systems 6 WiFi Adapter Box System Configuration  Transmit and receive  antennas are  connected to the WiFi Control  Box through  the  Adapter Box. The following diagram illustrates the connections.                                               WiFi Floor antenna WiFi Control Box Connections Legend TX Loop  Driving Cable RX Signal Receiver Antennas (Green) Transmitter Antenna (Blue) WiFi Door Guard --OR--
WiFi Floor Guard & Door Guard EAS Systems 7 PRE-INSTALLATION INFORMATION  Quick Start for System Connections  A Floor  Guard  system  consists  of  a smart  power  supply (WG  SPS-24),  WiFi  Control  Unit, Floor Antenna and Adapter box. A Door Guard system consists of a smart power supply (WG SPS-24), WiFi Control Unit, Door Guard and Adaptor Box. Connection between the various modules is identical.  The smart power supply has a 6-pin output connector for the 24vac output to power the WiFi Controller  and  also  communicate  with  the  control  unit  for  tuning  control  and  remote  alarm display features.  The WiFi Control Box is powered and controlled by the WG SPS-24 power supply unit. Also the  control  unit  has  two  4-conductor  connectors  for  cables  that  will  connect  to  the  WIFI Control Unit AM board. One of the connectors is 4-pin connector for TX transmitting signals from the Control Unit to drive a loop antenna coil. The other connector is a 4-pins connector for RX signals from the Control Unit to receive signals from Floor Guard RX antennas.  Note: Both the TX and RX cables are color coded and it is critical not to transpose the order.
WiFi Floor Guard & Door Guard EAS Systems 8 WIFI Control Unit and Adapter box and antenna Connection                                                            P1 P2 P3 P4   White White P1 P2 P3 P4 Red Green Red Green P1 P2 P3 P4 Red Brown   P1 P2 P3 P4 White Green Blue Orange  J2 J1 J2 J3 J5 J5-1 J4 J4-1 J7 J7-1 J6 J6-1 J3 J5 J1 J5-1
WiFi Floor Guard & Door Guard EAS Systems 9       J3 port of Adapter Box connects to the Transmit antenna (2 white wires).   J1 port of the Adaptor Box connects to the figure “O” antenna.   J2  port  of  the  Adaptor  Box  connects  to  the  figure  “8”  antenna.  At  this  time  there  is  no connection required for figure “8”; only figure “O”.   J5 port of the Adaptor Box connects the RX antenna to Adapter PCB (2pcs 2-core wires).  J5-1 port of the Adaptor Box is the output port for RX antenna.   SW5 is antenna phasing adjustment switch. Use this switch to adjust if the site is too noisy.              P1 P2 P3 P4 P5 P6 P7 P8     White Green Blue Orange P1 P2 P3 P4 Brown Red   SW5
WiFi Floor Guard & Door Guard EAS Systems 10   TX  ampere debug                                          Connect transmit detector to J1, turn on the power supply of CB and transmit detector, adjust TX “O” debug jumper, from the bottom the up. System will be under optimum working status when the transmit detector shows a value from 17 to 22.    TX “O” debug jumper TX “8” debug jumper
WiFi Floor Guard & Door Guard EAS Systems 11   Antenna Installation Instructions: The  antenna  is  designed  to  be  buried  in  the  flooring,  in  a  rectangular  of  sufficient  size  to conveniently  fit  the  antenna  size.  Coverage  may  be  standard  flooring  (concrete  or  wood material).  There is a cable extending out of the antenna case. Ensure the connector end is extended far enough for service access. Distance from the Antenna Box to the antenna should be no more than 25 feet. Distance between the Antenna Box and Controller should be no longer than the included interconnect cable.
WiFi Floor Guard & Door Guard EAS Systems 12 SMART POWER SUPPLY (WG SPS-24)   Controls and Connections                                               Fuse Replacement: Internal AC fuse rating (T3.15AL, 250V)  SPS Power On/Off Switch Main AC Power In 24vac Power & Data Output Input Voltage Select Switch A Input Voltage Select Switch B SPS Front View SPS Top View SPS Rear View Pedestal Alarm Volume Adjust TX Antenna On/Off Switch Caution!  Remove  power before service.
WiFi Floor Guard & Door Guard EAS Systems 13  Terminals Description                                       SPS Output Terminal Layout (10 pins)  SPS to Pedestal Cable (6 wires) Alarm Relay Jammer Relay Pin # 1 2 3 4 5 6 7 8 9 10 Function GND 24VAC TX OFF Alarm Anti- Jammer Alarm Volume     Electrical Common GND 26 VAC >4.0vdc <2.5vdc <2.5vdc 5-15vdc 1A  Contact 1A Contact I/O Output Output Output Input Input Output Output Output    SPS Main AC Input Terminal Layout  Main AC Cable (3 wires) Pin Function Color 1 Neutral Blue 2 Ground Green w/Yellow Stripe 3 Live Red(Brown) 1 2 3 N - GND - L Main AC Input Terminal 1 2 3 4 5 6 7 8 9 10 LED Status LED On Off TX Off TX is Off TX is On System Alarm Alarm Enabled Alarm Disabled Jammer Detection Detection Enabled Detection Disabled Alarm Volume Dim Means Weaker Bright Means Louder  Pin: Pin:
WiFi Floor Guard & Door Guard EAS Systems 14 Main AC Input and Voltage Setup  The Smart Power Supply (WG SPS-24) accepts 5 input voltages: 100vac 110vac and 120vac in North America and Japan, 220vac and 240vac in Europe and Australia.  Caution: Set the two Voltage Switches (A and B) on the power supply at the specified combination based on the local incoming voltage value (see picture below).                                                       Voltage Switch B HIGH     MID     LOW (Three Positions) AC Power In 100vac Voltage Switch A - 115 Voltage Switch B - LOW  110vac Voltage Switch A - 115 Voltage Switch B - MIDDLE  120vac Voltage Switch A - 115 Voltage Switch B - HIGH  220vac Voltage Switch A - 230 Voltage Switch B - MIDDLE 240vac Voltage Switch A - 230 Voltage Switch B - HIGH  Voltage Switch A
WiFi Floor Guard & Door Guard EAS Systems 15 External Relay interface  The external relay interface is located at Output side of the SPS.                                                 ***   Suggested Relay Ratings 1A@ 24 VDC Notes: 1.  Wire length to the dry contact circuit is limited to 20 feet. 2.  To prevent high voltage noise from being introduced into the transceiver and degrading the system’s performance, it is highly recommended that you use a 24vdc output relay. Last 4 pins on this end. Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 Power Supply Output Terminal Layout (10 pins)  SPS to Pedestal Cable (6 wires) Alarm Relay Jammer Relay Pin # 1 2 3 4 5 6 7 8 9 10 Function GND 24VAC TX OFF Alarm Anti- Jammer Alarm Volume     Electrical       1A  Contact Rating 1A Contact Rating