WHIRLPOOL Range Hood Manual L0604813
User Manual: WHIRLPOOL WHIRLPOOL Range Hood Manual WHIRLPOOL Range Hood Owner's Manual, WHIRLPOOL Range Hood installation guides
Open the PDF directly: View PDF .
Page Count: 7
Download | |
Open PDF In Browser | View PDF |
www,whirlpool,com IMPORTANT: Installer:LeaveInstallationInstructions with homeowner, Homeowner:KeepInstallationInstructions for futurereference, Save:InstallationInstructions for electrical inspector'suse, 24", 30" and 36" Custom Series Range Hood 628010A/9763371 Be£ere sta ... Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. 24" model: 30" model: 36" model: 23-7/8" 29-7/8" 35-7/8" \ This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word "DANGER"or "WARNING". These words mean: \\\ \ You can be killed or seriously injured if you don't immediately follow instructions. rectangular roof venf-_----._ knockout for (RH2300 series only) rearof hood You can be killed or seriously injured if you don't follow instructions. 17-5/8" _r 2 _r All safety messages will tell you what the potential hazard is, tell you how to reducethe chance of injury, and tell you what can happen if the instructions are not followed. Important: Observe and ordinances. all governing 7- 112" Check the location where the range hood will be installed, The location should be away from strong draft areas, such as windows, doors, and strong heating vents, Tools and materials needed for installation: • compass or 7" circle template • pliers • level • 1-1/4" drill bit • pencil • • • • caulking gun saber saw keyhole saw duct tape installation no_:gkouts A[]A ] ]5-volt, 60-Hz, AC-only, fused electrical supply is required. The total ampere load used, including the range hood, must not exceed 90% of the rated capacity of the circuit. The ampere rating of the range hood is located on the model/serial number rating plate located on the side cover of the blower motor housing. [] The range hood must be connected with copper wire only. [] The range hood can be connected directly to the fused disconnect (or circuit breaker) box through flexible armored or nonmetallic sheathed copper cable. A U.L.-listed strain relief must be provided at each end of the power supply cable. Wire sizes (COPPER WIRE ONLY) and connections must conform with the rating of the appliance as specified on the model/serial rating plate. The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or when such standard is not applicable, the Standard for Manufactured Home Installation ]982 (Manufactured Home Sites, Communities and Setups) ANSI A225, ]/NFPA 50]A, or latest edition, or with local codes, For power cord connected installations, a U,L,-listed range hood cord-connection kit MUST be used, Note: Some models come with a factory installed 3 ft, long power cord having a 3-prong ground plug, EIect caJ Wire sizes must conform to the requirements of the National Electrical Code ANSI/NFPA 70 --latest edition*, and all local codes and ordinances, reqeiremeats Important: Observe and ordinances. It is the customer's To contact installer. all governing codes responsibility: a qualified electrical To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 -- latest edition*, and all local codes and ordinances. If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate. Do not ground to a gas pipe. Check with a qualified electrician if you are not sure range hood is properly grounded. Do not have a fuse in the neutral or ground circuit. A WARNING -- To reduce the risk of fire or electrical shock, do not use this fan with any solid-state speed control device, WARNING -- TO REDUCE THE RISKOF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Use this unit only in the manner intended by the manufacturer, If you have questions, contact the manufacturer, Before servicing or cleaning unit, switch power off at service panel and lock switch power off at service panel and lock service panel to prevent power from being switched on accidentally, When the service disconnecting means cannot be locked, securely fasten a prominent warning device such as a tag to the service panel CAUTION: For general ventilating Do not use to exhaust hazardous materials and vapors, use only, or explosive WARNING -- TO REDUCE THE RISKOF A RANGE TOP GREASE FIRE: Never leave surface units unattended at high settings, Believers cause smoking and greasy spillovers that may ignite, Heat oils slowly on low or medium settings, Always turn hood ON when cooking at high heat or when cooking flaming foods, Clean ventilating fans frequently, Grease should not be allowed to accumulate on fan or filter, Use proper appropriate element, pan size, Always use cookware for the size of the surface WARNING -- TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: WARNING -- TO REDUCE THE RISKOF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING: Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable Codes and Standards, including Fire Rated Construction, Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting, Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA),and the American Society of Heating Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities, SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner, BE CAREFUL TO PREVENT BURNS, If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT, When cuffing or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. The fire department Ducted fans must always be vented outdoors, Panel RH2600 series vent hoods can be used for non-vented (recirculating) installations only. wirin • ruler • Phillips screwdriver • metal snips • drill home RH2300 series vent hoods can be used for vented installations only. codes Proper installation is your responsibility, Make sure you have everything necessary for correct installation, It is the responsibility of the installer to comply with the clearances specified, Mobile rectangular backvent (RH2300 series only) WARNING -- To reduce only metal ductwork, NEVER PICK UP A FLAMING PAN -- You may be burned, DO NOT USEWATER, including wet dishcloths or towels -- a violent steam explosion will result, Use an extinguisher ONLY if: You know you have a Class ABC extinguisher, and you already know how to operate it, The fire is small and contained where it is started, in the area is being called, You can fight the fire with your back to an exit, to the the risk of fire, use Copies of standards listed may be obtained * National FireProtectionAssociation Bafferymarch Park Quincy, Massachusetts 02269 from: Now Horizontalwall venting start... With range hood in kitchen. Venting system must terminate outside, to the Do not terminate the vent in an attic other enclosed space, Do not use four-inch caps, laundry-type Slide cardboard or hardboard under range before moving range across floor to prevent damaging floor covering. Cover countertop, cooktop or set-in range with a thick, protective covering to prevent damaging countedop. 3-114" x 10" through the wall cap or wall [] Disconnect and move freestanding range from cabinet opening to provide easier access to upper cabinet and rear wall, Put a thick, protective covering over cooktop, set-in range or countertop to protect from damage or dirt, Do not use plastic vent, Vent system needed for installation is not included. Backdraft damper supplied with product must be used, If roof or wall cap has a damper, do not use damper supplied with hood, Use metal vent only, Rigid metal vent is recommended, Determine which outside venting you need to use, method The length of the vent and number of elbows should be kept to a minimum to provide efficient performance, The size of the vent should be uniform, Do Not install two elbows together, Use duct tape to seal all joints in the vent system, Vent can terminate either through the roof or wall, Use caulking to seal exterior wall or roof opening around exhaust hood, For the most efficient and quiet operation, it is recommended that the range hood be vented vertically through the roof using 7" round vent, Figures ]-4 show common venting methods and what types of materials are needed, Verticalroofventing roof cap 7" round _ "b - throu_ damper _ ] I I I ] I located as far from hood as possible __ J l I J _ I Figure 3 roof cap If your range hood is a non-vented= (recirculating) only model, go to Step 3a, Panel D, 3-114" x 10" to round vent transition Figure 4 Recommended 3= ]/4" to 7" tiffing vent To install a length Use 3-1/4" x 10" or 7" vent with a maximum length of 26 feet for vent system, For best performance, use no more than three 90 ° elbows, To calculate the length of system you need, add the equivalent feet for each vent piece used in the system, See the following examples, x ] 0" vent b_6 3-114" x 10" 66,,_ wall cap 7" min. diameter round vent 3-1/4" x 10" __ [] If your range hood is a vented-only model, determine which venting method (roof or wall venting) you need to use, ] 2 ft. ____ wall cap = = = 1-walleap Length of 3-1/4" x 10" system 5 ft, 8 ft, 0 ft, =13 ft, Figure ] Recommended Verticalroofventing standard fiffings • wiring knockouts [] Remove knockout from the wiring opening (top or rear) to be used, For rectangular venting, remove only the 3-1/4" x 10" rectangular opening knockout for the venting method (roof or wall) you have selected, roof cap J 3-1/4" x 10" go ° elbow = 5 ft. 3-1/4" x 10" through the roof rectangular knockouts = 26 feet lengf ] - 90 ° elbow 8 feet straight II model system ft. Maximum ] yented-only Installatlon: 7" vent 3-1/4" x 10" flat elbow = 12 ft. terminal - box 3-1/4" x 10" wall cap = 0 ft. cover system go ° elbow 2 _(-_6 T _ycap 2 ft. _!_ / 3-114" x 10" to 7" transition Figure 2 Recommended 3-1/4" x 10" to 7" = 4.5 ft. ft. -- Maximum length 1 - transition 2- 90 ° elbows ] -wallcap 8 feet straight = = = = = Length of 7" system = 22,5 ft, standard 3-1/4" x 10" to 7" 90 ° elbow = 5 ft, 26 feet 4,5 ft, 10 ft, 0 ft, 8 ft, fittings 90 ° elbow = 5 ft, [] If your model does NOT have a factory installed power cord, remove terminal box cover from range hood, Excessive Weight Hazard Use two or more people to move and install range hood. Failure to follow this instruction can result in back or other injury. keyhole slot front hood 45 ° elbow : 2.5 ft. 7" wall cap = 0 ft. [] Lift the range hood into final position and center, Mark on the underside of cabinet the location of the four keyhole mounting slots, Set range hood aside on a protected surface, Panel B vent ' I E Numbers correspond fo sfeps. 'jII centerlJne IIII Determine and clearly mark a vertical centerline on the wall and cabinet in the area the vent opening will be made, '1 'i I 2 It i i i i from wall (not cabinet frame) l cabinet cutouts i ! i I I i centerlJne II [] 5- '1/4" To wire through fop, mark a line 7-1/2" from the right of the centerline on the underside of the cabinet, Mark the point on this line that is 2" from back wall, Drill a 1-1/4" diameter hole through the cabinet at this point, Note: If a cordconnection kit is used, drill a 1-5/8" diameter hole, I * from wall, not cabinet frame I I I '1, '11 I L To wire through rear, mark a line 7-1/2" from the right of the cenferline on the wall, Mark the point on this line that is 65-1/4" from the floor (or 3/4" from underside of cabinet), Drill a ] -1/4" diameter hole through wall at this point, To make a 4"x 10-1/2" rectangle on the underside of cabinet fop and bottom: a. Mark lines 1-1/2" and 5-1/2" from the back wall on the centerline of the underside of cabinet, b. Mark lines 5-1/4" to the right and left of the centerline on the underside of cabinet, c. Use saber and keyhole saws to cut a rectangular opening for vent, d. Repeat steps a-c for the underside of the top of the cabinet, If venting through the wall with 3-1/4" x 10" rectangular vent -To make a 4"x 10-1/2" rectangle in the wall: a. Measure from floor 65-7/8" and 62-3/8" (or 1/8" and 3-5/8" down from underside of cabinet) and mark on the cenferline on the back wall, b. Mark lines 5-1/4" to the right and left of the cenferline on the underside of cabinet, c. Use saber and keyhole saws to cut a rectangular opening for vent, To transition from a 3-1/4" x 10" rectangular vent to a 7" round vent and vent through the roof -Start by making a 4"x 10-l/2" rectangle on the underside of cabinet bottom: a. Mark lines 1-1/2" and 5-1/2" from the back wall on the cenferline of the underside of cabinet, b. Mark lines 5-1/4" to the right and left of the cenferline on the underside of cabinet, c. Use saber and keyhole saws to cut a rectangular opening for vent, 7-1/8'L-_,_ cabinet 7-5/8" -'1-1/2" *from wall not cabinet frame / It i Now make a 7-1/8" x 7-5/8" slot on the underside of the cabinet fops, d. Mark lines 5" and 5-1/2" from the back wall on the cenferline on the underside of the fop of cabinet, e. Draw two 7-1/8" circles using the marks made in step d as center points, f. Use saber and keyhole saws to cut a slotted (oval) opening to make installing 7" round vent easier, Panel C For cord connected models: f [] Install vent through the vent opening in upper cabinet or wall, Complete venting system according to method needed, See "Venting requirements," Use caulking to seal exterior wall or roof opening, Electrical Shock Hazard Plug into a grounded Do not remove ground 3-prong outlet. centerline prong. Do not use an adapter. Failure to follow these instructions can result in death, fire, or electrical shock. [] If roof or wall cap does not have a damper, attach rectangular damper supplied with hood to selected rectangular vent opening, If damper is attached to back of range hood, be sure damper hinge is toward the top, If roof or wall cap does not have a damper and round vent is used, install damper (supplied with hood) in vent to prevent air from flowing back into vent, If roof or wall cap has a damper, Do not use damper blade supplied with range hood, [] Do not turn on power until installation is complete. Run wiring through wall or cabinets according to the National Electrical Code and local codes and ordinances, Use caulking to seal ceiling or outside wall opening, keyhole slot front of hood vertical For your personal safety, this range hood must be grounded, To minimize possible shock hazard, the cord must be plugged into a mating, 3-prong, ground-type outlet, grounded in accordance with National Electrical Code, ANSI/NFPA 70 - latest edition* and all local codes and ordinances, If mating outlet is not available, it is the responsibility and obligation of the customer to have a properly grounded, prong outlet installed by a qualified electrician, Do not use an extension Using a U.L.-listed cord-connection 3- )11 [] Determine centerline and clearly in the cabinet i I II I , I '1 I I mark a opening, I I I '11 wall cabinet frame) I LI cord, power supply kit: centerline Follow Power Cord Kit instructions for connecting wiring. Replace terminal a box cover, For models with a factory installed power cord: Plug power outlet, Check that screw is in narrow neck of slot. a cord into grounded 3-prong []To wire through top, mark a line 7-1/2" from the right of the centerline on the underside of the cabinet, Mark the point on this line that is 2" from the back wall, Drill a 1-1/4" diameter hole through cabinet at this point, Note: If a cordconnection kit is used, drill a 1-5/8" diameter hole, screw [] Start screws in the center of the narrow neck of each of the four keyhole mounting screw slots marked on the cabinet bottom, I / I Ii i '11 [] Lift range hood into final position, feeding electrical wire through wiring opening, Tighten mounting screws to cabinet, making sure mounting screws are in narrow neck of slots, , l- i i 3/4" I I i 7-112" L [] Remove knockout from the wiring opening (rear or top) to be used, The range hood cabinet may have venting knockouts, Do not remove these venting knockouts. The model cannot be vented, X terminal / Electrical I cover 65-1/4" (to floor) I i i i i i i centerline To wire through rear, mark a line 7-1/2" from the right of the centerline on the wall, Mark the point on this line that is 65-1/4" from the floor (or 3/4" from underside of cabinet), Drill a 1-1/4" diameter hole through wall at this point, Shock Hazard Disconnect power before making electrical connections. Connect ground wire to green ground screw in terminal box. Failure to do so can result in death or electrical shock. [] If your model does NOT have a factory installed power cord, remove terminal box cover on range hood, Do not turn on power until installation is complete. Use caulking to seal ceiling or outside wall opening, Run wiring through wall or cabinets according to the National Electrical Code and local codes and ordinances, keyhole white Excessive ground Weight Hazard Use two or more people to move and install range hood. Failure to follow this instruction can result in back or other injury. slot front of hood Check that screw is in narrow neck of slot. g a [] Start screws in the center of the wire [] For models front of hood requiring direct wiring: Connect the white and black wires of the power supply cable to the white and black leads in the range hood with twist-on connectors, Connect the power supply ground wire to the green ground screw inside the range hood terminal box, Use caulking to seal wire opening, Replace terminal box cover Panel D narrow neck of each of the four keyhole mounting screw slots marked on the cabinet bottom, keyhol_ [] Lift range hood into final position and center, Mark on underside of cabinet the location for the four keyhole mounting slots, Set range hood aside on a protected surface, [] Lift range hood into final position, feeding electrical wire through wiring opening, Tighten mounting screws to cabinet, making sure mounting screws are in narrow neck of slots, Use & (::are Information OPERATION If range hood does not operate... OF RANG=: HOOD 1 For best results, turn range hood fan on at beginning of cooking and allow it to run until all smoke and odors are removed from room, Electrical Shock Hazard Disconnect power before making electrical connections. To operate fan: Press fan control to turn fan on and off and adjust fan speed, Speed may be increased or decreased anytime during range hood operation, Connect ground wire to green ground screw in terminal box. Failure to do so can result in death or electrical shock. To operate light: Press light control to turn light on or off, Light may be turned to off or on anytime during range hood operation, white f LL..L.__ II[L La_.._.Jj ITT-1 I c_ sr sE ss ,_0, wire CARE OF RANGE requiring direct wiring: Connect the white and black wires of the power supply cable to the white and black leads in the range hood with twist-on connectors, Connect the power supply ground wire to the green ground screw inside the range hood terminal box, Filter/light HOOD and clean To remove filter/light lens: Pull firmly on filter tab to remove filter/light lens from range hood, To clean filter/light lens: Place filter/light lens in dishwasher sudsy water to clean, Electrical Do not remove ground 3-prong outlet. When it's time to replace your aluminum filter/light lens, or charcoal pads: prong. Do not use an adapter. Failure to follow these instructions can result in death, fire, or electrical shock. For your personal safety, this range hood must be grounded, To minimize possible shock hazard, the cord must be plugged into a mating, 3-prong, ground-type outlet, grounded in accordance with National Electrical Code, ANSI/NFPA 70 -latest edition* and all local codes and ordinances, If mating outlet is not available, it is the responsibility and obligation of the customer to have a properly grounded, prong outlet installed by a qualified electrician, Do not use an extension cord, Using a U.L.-Iisted power cord-connection kit: supply Follow Power Cord Kit instructions for connecting wiring. Replace terminal box cover, For models with a factory installedpower cord: Plug power outlet, cord into grounded IIIITurn power or hot To reinstall filter/light lens: Place edge of filter/light lens in opening so that right side is above flange and tab faces downward, Press filter/light lens into position, Shock Hazard Plug into a grounded often, filter tab models: 3-prong supply on, 3- Model Series RH2600 (recirculating): Order complete filter replacement kit no, 883093 (includes Filter/Light Lens no,883149 and Charcoal Filter Pads no, 883151 ,) Filter/Light Lens, no, 883149 and Charcoal Filter Pads, no, 883151 can be ordered separately, 2, Call Whirlpool's 1-800-442-9991 3, Give the Telesales Representative part number needed, 4, The Representative current price, the will give you the 5, Place your order using your Master Card @, Visa @or Discover @credit card, 6, If you wish: mail a check or money order to: Whirlpool Corporation 1900 Whirlpool Drive LaPorte, IN 46350-9980 Attn: Accessory Accounting 7, Be sure to ask the Telesales Representative about the wide variety of other Whirlpool Product Accessories, Exterior blower motor cloth surfaces Clean the range hood with a mild detergent and soft cloth, Do Not use abrasive cleansers or steel wool pads, Light Do not use bulb larger than 60 watts in light socket, Light bulb is not included, Panel E Callthe WhirlpoolConsumer Assistance Center telephone number. Dialfoil-free from anywhere inthe U.S.A.1-800=253=1301 and talk with one of our trained consultants, The consultant can instruct you in how to obtain satisfactory operation from your appliance or, if service is necessary, recommend a qualified service company in your area, If you prefer, write to: Please include a daytime your correspondence, phone number in Whirlpool has a nationwide network of authorized Whirlpool service companies, Whirlpool service technicians are trained fulfill the product warranty and provide after-warranty service, anywhere in the United States, To locate the authorized Whirlpool service company in your area, call our Consumer Assistance Center telephone number (see "If you need assistance") or look in your telephone directory Yellow Pages under: to * APPLIANCE--HOUSEHOLD-MAJOR, SERVICE & REPAIR -- See: Whirlpool Appliances or Authorized Whirlpool Service (Example: XYZ Service Co,) * WASHING MACHINES & DRYERS, SERVICE & REPAIR -- See: Whirlpool Appliances or Authorized Whirlpool Service (Example: XYZ Service Co,) When asking for help or service: Please provide a detailed description of the problem, your appliance's complete model and serial numbers and the purchase date, This information will help us respond properly to your request, Telesales line at Clean exterior of motor with a damp and grease-cuffing detergent, from: filter 1, Find the model/serial number rating plate located on the side cover of the fan motor housing, Model Series RH2300 (vented): Order Filter/Light Lens no, 883103 To cleon Copies of standards listed may be obtained * National Fire Protection Association Batterymarch Park Quincy, Massachusetts 02269 asststa:nce... If you need semite... Use caulking to seal wire opening, Replace terminal box cover, For cord connected lens For best results, remove If you need Consumer Assistance Representative Whirlpool Corporation 2000 North M-63 Benton Harbor, MI 49022-2692 m For models Check that the circuit breaker is not tripped or the house fuse blown, If you need FSP ® rep:lacement :parts... FSP is a registered trademark of Whirlpool Corporation for quality parts, Look for this symbol of quality whenever you need a replacement part for your WHIRLPOOL ° appliance, FSP replacement parts will fit right and work right, because they are made to the same exacting specifications used to build every new WHIRLPOOL appliance, To locate FSP replacement parts in your area, refer to "If you need service" or call the Whirlpool Consumer Assistance Center number in "If you need assistance," WHIRLPOOLCORPORATIONMAJORAPPLIANCEWARRANTY ONE YEAR LIMITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, Whirlpool Corporation or Whirlpool Canada LP (hereafter "Whirlpool") will pay for FSP replacement parts and repair labor to correct defects in materials or workmanship. Service must be provided by a Whirlpool designated service company. ITEMS WHIRLPOOL WILL NOT PAY FOR 1. Service calls to correct the installation of your major appliance, to instruct you how to use your major appliance, to replace or repair house fuses or to correct house wiring or plumbing. 2. Service calls to repair or replace appliance light bulbs, air filters or water filters. Those consumable coverage. 3. Repairs when your major appliance is used for other than normal, single-family 4. Damage resulting from accident, alteration, misuse, abuse, fire, flood, acts of God, improper installation, accordance with electrical or plumbing codes, or use of products not approved by Whirlpool. 5. Any food loss due to refrigerator or freezer product failures. 6. Replacement parts or repair labor costs for units operated outside the United States or Canada. 7. Pickup and delivery. This major appliance is designed to be repaired in the home. 8. Repairs to parts or systems resulting from unauthorized 9. Expenses for travel and transportation modifications parts are excluded from warranty household use. installation not in made to the appliance. for product service in remote locations. 10. The removal and reinstallation of your appliance if it is installed in an inaccessible published installation instructions. location or is not installed in accordance with DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES CUSTOMER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED HEREIN. IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW. WHIRLPOOL SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS, SO THESE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS, WHICH VARY FROM STATE TO STATE OR PROVINCE TO PROVINCE. Outside the 50 United States and Canada, this warranty does not apply. Contact your authorized Whirlpool dealer to determine if another warranty applies. If you need service, first see the "Troubleshooting" section of the Use & Care Guide. After checking "Troubleshooting," additional help can be found by checking the "Assistance or Service" section or by calling Whirlpool. In the U.S.A., call 1-800-253-1301. In Canada, call 1-800-807-6777. 8/05 528010A/9753371 _) 2005 Whirlpool Corporation _) Registered Trodemork/SM Trddemdrk of Whirlpool, U.S.A. Benton Hdrbor, Michigan 49022 Printed in U,S,A. 09/2005
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 7 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Fri Apr 20 14:26:39 2007 Author : Title : Subject :EXIF Metadata provided by EXIF.tools