WILLIAMS Heater/LP Gas Manual L0408171
User Manual: WILLIAMS WILLIAMS Heater/LP Gas Manual WILLIAMS Heater/LP Gas Owner's Manual, WILLIAMS Heater/LP Gas installation guides
Open the PDF directly: View PDF .
Page Count: 23
MODEL NOS:
FOR NAT. GAS ONLY
2001612; 2001622
3501512; 3501522
3501912; 3501922
5001512; 5001522
5001912; 5001922
6501512; 6501522
6501912; 6501922
MODEL NOS.
FOR L.R GAS ONLY
2001611 2001621
3501511 3501521
3501911 3501921
5001511; 5001521
5001911; 5001921
6501511; 6501521
6501911; 6501921
INSTALLATION & OPERATING INSTRUCTION MANUAL
350 MODEL SERIES SHOWN
READ THIS OWNERS MANUAL
CAREFULLY BEFORE YOU INSTALL
YOUR NEW WILLIAMS
VENTED ROOM HEATER
WARNING: Improper installation, adjust-
ment, alteration, service or maintenance
can cause injury or property damage.
Refer to this manual. For assistance or
additional information consult a qualified
Installer, service agency or the gas
supplier.
WARNING: Do not install any of these fur-
naces (Natural or L.P. Gas) in mobile
homes, trailers, or recreational vehicles.
WARNING: If the information in this l
manual is not followedexactly, a fire or ex- I
plosion may result causing property
damage, personal injury or loss of life.
-- Do notstore or use gasolineor other flam-
mable vapors and liquids in the vicinity
of this or any other appliance.
-- WHAT TO DO IF YOU SMELL GAS
•Open all windows.
•Do not try to light any appliance.
•Do not touch any electrical switch; do
not use any phone in your building.
• Extinguish any open flame.
•Immediatelycallyourgas supplierfrom
a neighbor's phone. Follow the gas
supplier's instruction.
•If you cannot reach your gas supplier,
call the fire department.
-- Installation and service must be per-
formed by a qualified installer, service
agency or the gas supplier.
WILLIAMS Furnace Co., 225 Acacia St., Colton, CA 92324
PRINTED IN USA 4/98 P500407
IMPORTANT
TO THE PURCHASER: Keep this warranty and the installation and homeowner's instructions for your future reference.
LIMITED WARRANTY
The Manufacturer, Williams Furnace Co., warrants this wall furnace or heater to the original purcheser under the following conditions:
LIMITED ONE-YEAR WARRANTY
1. Any part thereof which proves to be defective in material or workmanship within one year from date of odginal purchase for use will be repaired
or replaced at the Manufacturer's option, FOB its factory.
2. No liability is assumed by the Manufacturer for removal or installation labor costs, nor for freight or delivery cha_ges.
LIMITED EXTENDED WARRANTY
1. In addition to the above limited one-year warranty on the complete unit, any heat exchanger which bums out or rusts under normal installation,
use and service conditions dudng a period of nine years following expiration of the one-year warranty pedod will be exchanged for a like or
functionally similar part, FOB Manufacturer's factory.
2. No liability is assumed by the Manufacturer for removal or installation labor costs, nor for freight or delivery charges.
LIMITATIONS
I. THIS LIMITED WARRANTY IS THE ONLY WARRANTY MADE BY THE MANUFACTURER. IMPLIED WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR ANY PARTICULAR PURPOSE ARE LIMITED TO THE SAME ONE YEAR TERM AS THIS EXPRESS WARRANTY. UNDER
NO CIRCUMSTANCES SHALL THE MANUFACTURER BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, SPECIAL OR CONTINGENT
DAMAGES OR EXPENSES ARISING DIRECTLY OR INDIRECTLY FROM ANY DEFECT IN THE I_RODUCT OR ANY COMPONENT OR FROM
THE USE THEREOF. THE REMEDIES SET FORTH HEREIN ARE THE EXCLUSIVE REMEDIES AVAILABLE TO THE USER AND ARE IN LIEU
OF ALL OTHER REMEDIES.
Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow
the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions
may not apply to you.
2. This warranty does not include any charge for labor or installation.
3. This warranty does not extend to painted surfaces nor to damage or defects resulting from accident, alteratico, misuse or abuse, or improper
installation.
4. This warranty does not cover claims which do not involve defective workmanship or materials.
DUTIES OF THE CONSUMER
1. The heating equipment must be installed by aqualified installer end operated in accordance with the installation end homeowner's instructions
furnished with the equipment.
2. Any travel, diagnostic costs, service labor, and labor to repair the defective unit will be the responsibility of the owner.
3. A bill of sale, cancelled check, payment record or permit should be kept to verity purchase date to establish the warranty pedod.
4. Have the installer enter the requested information in the space below.
GENERAL
1. The Manufact uror neither essumes nor aut hodzes any pereon to essoma for it any cther obligation or liability In connantion with said equipmect.
2. Service under this warranty should be obtained by contacting your dealer. Provide the dealer with the modeq number, sodal number and pur-
chase date verification.
3. If, within a reasonable time after contacting your dealer, satisfactory service has not been received, contact: Customer Service Department,
225 Acacia St., Colton, CA 92324, for assistance.
4. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATETO STATE.
INSTALLATION INFORMATION
Model No. Serial No.
Odg. Purchaser.
Address
City and State. Zip
Dealer
Address.
City and State. Zip
Installation date Signed by (Dealer or
authorized representative who certifies that this appliance has been installed in accordance with Manufacturer's instructions and
local codes.)
--2--
A Word From The Manufacturer
Dear Customer,
Toset up our furnace assembly procedures, several hundred quality assurance, safety audit and design performance
tests have been conducted according to the standards provided by the American National Standards Institute, the Depart-
ment of Energy and our certification agency -- the American Gas Association Laboratories.
This was done to assure you of receiving the best value and most reliable appliance of its type available today.
We are confident that your Williams furnace can provide you years of low cost, efficient, heating comfort.
Thank you for purchasing a Williams furnace. Sincerely,
Employees of Williams Furnace Company
Introduction
Please read our instructions before you install and use your heater. This will help you obtain the full value from this
heater. It could help you avoid needless service costs, if the answer to the problem is found within this instruction
manual.
Basic Description
Always consult your local heating or plumbing inspec-
tor, building department or gas utility company
regarding regulations, codes or ordinances which
apply to the installation of a vented room heater.
The heat exchanger is built of heavy gauge steel treat-
ed for corrosion resistance. The heater cabinet is also
constructed of heavy gauge steel and has an enamel
paint finish.
No electric power is required unless furnace is
equipped with an optional blower accessory.
The efficiency rating of this appliance is a product ther-
mal efficiency rating determined under continuous
operating conditions and was determined independent
of any installed system.
Warmed air is discharged into the room in which the
heater is located.
The heater contains a single multi-slot gas burner.
Combustion air is drawn in from the room where the
heater is located and is vented out of the heater verti-
cally through vent piping to a roof vent top. (Vent
equipment is not supplied with heater).
The heater controls are located behind a access door
on the side of the heater. All models are equipped with
AGA listed gas valves and pilots.
NOTE, ALL MODELS:
This appliance is equipped with a vent safety shutoff
system, designed to protect against improper venting
of combustion products. Operation of this room
heater when not connected to a properly installed and
maintained venting system or tampering with the vent
safety shutoff system can result in carbon monoxide
(CO) poisoning and possible death.
Helpful Installation Information
The following booklets will help you in making the
installation:
ANSIINFPA 70, or current edition "National Electrical
Code:' In Canada: CSA C22.1 Canadian Electrical
Code.
American National Standard Z223.1 or current edition
"National Fuel Gas Code:'
Obtain from--Amedcan National Standards Institute,Inc.,
1430 Broadway, New York, N.Y. 10018. In Canada: CAN/
CGA B149.
--3--
Safety Rules
WARNING.
READ THESE RULES AND THE INSTRUCTIONS
CAREFULLY. FAILURE TO FOLLOW THESE
RULES AND INSTRUCTIONS COULD CAUSE A
MALFUNCTION OF THE FURNACE. THIS COULD
RESULT IN DEATH, SERIOUS BODILY INJURY,
AND/OR PROPERTY DAMAGE.
7.
umn. The maximum inlet gas supply pressure is 13"
water column.
ANY SAFETY SCREEN, GUARD OR PARTS RE-
MOVED FOR SERVICING FROM THIS APPLIANCE
MUST BE REPLACED PRIOR TO OPERATING THE
APPLIANCE TO AVOID PROPERTY DAMAGE, BOD-
ILY INJURY OR DEATH.
INSTALLATION MUST CONFORM TO LOCAL CODES. IN
THE ABSENCE OF LOCAL CODES, INSTALLATIONMUST
CONFORM WITH THE NATIONAL FUEL GAS CODE, ANSI
Z223.1. THE APPLIANCE, WHEN INSTALLED, MUST BE
ELECTRICALLY CONNECTED AND GROUNDED IN
ACCORDANCE WITH LOCAL CODES OR, IN THE
ABSENCE OF LOCAL CODES, WITH THE CURRENT
NATIONAL ELECTRICAL CODE ANSI/NFPA NO. 70.
IN CANADA
1. INSTALLATION MUST CONFORM TO LOCAL
CODES OR, IN THE ABSENCE OF LOCAL
CODES, THE CURRENT CAN/CGA B149 IN-
STALLATION CODE.
2. THE APPLIANCE, WHEN INSTALLED, MUST BE
ELECTRICALLY CONNECTED AND GROUND-
ED IN ACCORDANCE WITH LOCAL CODES OR,
IN THE ABSENCE OF LOCAL CODES, WITH
THE CURRENT CSA C22.1 CANADIAN ELEC-
TRICAL CODE.
3. REFERENCE IS MADE IN THIS MANUAL
REGARDING GAS TYPE AS L.P.G.BE ADVISED
THAT L.RG. IS NOT AVAILABLE IN CANADA,
REFER TO PROPANE/L.R GAS.
1.
2,
3_
.
.
.
I
8. INSTALL the heater vent directly to the outdoors, so
that harmful gases will not collect inside the building.
Followthe venting instructionsfor your type of installa-
tion exactly. Use only the type and size of vent pipe
and fittings specified.
9. BE SURE to provide for adequate combustion and
ventilation air. See page 7. The flow of this air to the
heater must not be blocked.
10. NEVER test for gas leaks with an open flame. Llse
soap suds to check all gas connections.This will avoid
the possibility of fire or explosion.
11. ALLOW heater to cool before servicing. Always shut
off electricity and gas to heater when working on it.
This will prevent any electrical shocks or burns.
12. DUE TO HIGH TEMPERATURES, locate the heater
out of traffic and away from furniture and draperies.
13. ALERT children and adults to the hazards of high sur-
face temperature and to keep away to avoid burns or
clothing ignition.
14. CAREFULLY supervise young children when they are
in the same room with the heater.
15. DO NOT place clothing or other flammable material
on or near heater.
USE ONLY MANUFACTURER'S REPLACEMENT
PARTS. USE OF ANY OTHER PARTS COULD CAUSE
INJURY OR DEATH.
DO NOT install this heater in an alcove.
DO NOT installthese heaters in a travel trailer, recrea-
tional vehicle or mobile home.
MAINTAIN all clearances specified in section
"Locating Room Heater" and "Vent Installation."
BE SURE heater is for type of gas to be used. Check
the rating plate by the gas valve in the lower cabinet.
Do not change it to use other gases. Unsafe opera-
tion could result and could cause bodily injury and
death.
For Natural gas, the minimum inlet gas supply
pressure for the purpose of input adjustment is 5" col-
umn. The maximum inlet gas supply pressure is 7"
water column.
FOr L.R gas, the minimum inlet gas supply pressure
for the purpose of input adjustment is 11" water col-
16.
17.
18.
19.
INSTALLATION and REPAIR must be done by a quali-
fied service person. The appliance should be inspected
before use and at least annually by a professionalserv-
ice person. More frequent cleaning may be required
due to excessive lint on the material, etc. It is im-
perative that control compartments, burners and cir-
culating air passages be kept clean. Failure to keep
burner-control compartment and other parts of heater
clean can cause dangerous conditions to develop
which can cause injury and even death.
BEFORE INSTALLING optionalblower:.Toavoid electri-
cal shock, turn off electrical circuitsthat pass through
the wall where you are going to install the heater.
BE AWARE of good safety practices by wearing per-
sonal protective equipment such as gloves and safe-
ty glasses to avoid being injured by sharp metal edges
in or around heater and while cutting or drilling holes
in wood and/or sheet metal.
CAUTION: Label all wires prior to disconnectionwhen
servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after
servicing.
WARNING
DO NOT USE THIS HEATER IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL A QUALIFIED
SERVICE TECHNICIAN TO INSPECT THE HEATER AND TO REPLACE ANY PART OF THE CONTROL SYSTEM
AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER. I
---4---
LOCATING THE HEATER -- MINIMUM FRESH AIR OPENING IS 1 SQUARE INCH PER 1,000 BTUIHR.
WARNING: Gas burning appliances require air for combusion and proper venting. Minimum fresh air opening of 1square
inch per 1000 BTU per hour input rating must be provided for ventilation. EXAMPLE: A30,000 BTU per hour input unit
requires the equivalent of a 30 inch wide window be open 1 inch for safe operation.
A. In choosing the location for the heater, the following factors should be considered:
1. Convenience to gas supply.
2. Arrangement of rooms or area to be heated.
3. Probable location of funiture.
4. General appearance.
5. Safe clearance from anything that could catch fire.
B. Locate the heater centrally in the area which it is to heat. The ideal location is at the source of cold air, which is
an outside wall. If the heater is on an outside wall, the cold air will be warmed before it moves through the room.
C. Place the heater where the air will circulate freely throughout the area to be heated. If one heater is intended to
heat the entire house, it is adviseable to consider the installation of grilles immediately below the ceilings to permit
circulation of hot air from room to room. Return air grilles are also desirable.
D, Be certain the heater is placed where the air is free to cimulate around it. Never install the heater in a wall recess.
The minimum clearance required to any wall or object can be found on the rating plate located inside the furnace
control door on the base plate. We recommend a 24-inch min. clearance from the burner access door for the ease
of lighting and for observation of pilot and burner flames.
E. NOTE: Heater must be installed so that drafthood is in the same pressure zone as the combustion air.
F. The heater may be placed directly on wood floors.
Heavy pile or shag rugs may restrict normal air flow.
Some floor coverings discolor easily from even low
heat. To assure safe operation, afloorboardextending
the full depth and width of the appliance must be
placed under the heater.
G. Do not place heater where curtains, draperies, or any
other material may come into contact with any part
of the heater.
GAS CONTROLS
A. All models are regulated on Natural and L.R gases.
The regulator is built into the gas control valve.
B. All models are equipped with a 100% pilotsafety shut-
off and a vent safety shut-off system.
C. CAUTION: Do not connect 115V electrical service
line to gas control valve or wall thermostat.
GAS SUPPLY
For Natural gas, the minimum inlet gas supply pressure
for the purpose of input adjustment is 5" water column.
The maximum inlet gas supply pressure is 7" water
column.
For L.R gas, the minimum inlet gas supply pressure for
the purpose of input adjustment is 11" water column. The
maximum inlet gas supply pressure is 13" water column.
Gas pressures and input to the burners must not exceed
the rated input and pressure shown on the rating plate.
On Natural Gas the manifold pressure should be 4 inches
water column. The manifoldpressure,shouldbe 10.5 inches
water column for L.P. Gas.
Orifice change may be required to suit gas supplied.
Check with your WILLIAMS service department.
FOr heater located at elevations between sea level and
2000 feet, the measured input must not be greater than
the input shown on the rating plate of the heater.For eleva-
tions above 2000 feet, the measured input must not ex-
ceed the input of the rating place reduced by 4 percent
for each 1000 feet that the heater is above sea level.
REQUIRED CLEARANCE
MODEL "A" "B" "C"
SIDE CEIUNG REAR
200 SERIES 2" MIN. 22" MIN. 3" MIN.
350 SERIES 6" MIN. 57" MIN. 6" MIN.
!500 SERIES 6" MIN. 57" MIN. 6" MIN.
650 SERIES 6" MIN. 57" MIN. 6" MIN.
=
OBSL='RVA'nONOF PILOTAND BURNER FLAMES.
o" \
FRONT VIEW
Fig. 1
--5--
PIPING THE GAS TO THE HEATER
State and local authorities have established codes regulating the installation of gas burning equipment. Consult your
gas supplier or gas company for complete information. In the absence of local codes, all aspects of the installation must
comply with the national fuel gas coda ANSI Z223.1. In Canada: Follow CAN/CGA-B149.1(2) Canadian Standard.
A. Use 1/2-inchpipe or semi-rigid tubing for natural and liquefied petroleum gases. DO NOT USE FLEXIBLE HOSE.
Appliance connectors of corrugated metal tubing and fittings that are listed by a nationally recognized testing agen-
cy may be used if accepted by the local code authorities. FOLLOW THE MANUFACTURERS INSTALLATION
INSTRUCTIONS. This type of connector may only be installed in the room where the heater is located.
B. A manual shut-off valve and union must be installed inthe gas supply line just ahead of the connection to the heater.
The manual valve must include a lie-inch NPT plugged tapping accessable for connection of a test gauge.
C. Unions in the gas supply lines shall be of the ground joint type. Compounds used on threaded pipe joints must be
resistant to the action of liquefied petroleum gases.
WARNING:
WHEN CONNECTING FIELD PIPING, USE A SECOND WRENCH TO KEEP THE HEATER VALVE FROM TURNING.
SUPPORT FIELD PIPING PROPERLY, STRESS AND OVERTIGHTENING COULD DAMAGE THE GAS VALVE AND
RESULT IN DANGEROUS GAS LEAKS WHICH CAN CAUSE DANGEROUS CONDITIONS INCLUDING PROPER-
TY DAMAGE, BODILY INJURY, AND EVEN DEATH.
D. Adripleg Fig. 2 should be installed to constitute a trap to catch any condensate that may be in the gas. The dripleg
should be readily accessible for cleaning.
E. The heater must be disconnected from the gas supply system and from the heater individual shut-off valve when
the system is tested at a pressure in excess of 1/2 PSIG.
F. IMPORTANT."CHECK ALL FACTORY AND FIELD PIPE JOINTS FOR GAS LEAKS BEFORE AND AFTER LIGHTING
THE HEATER. USE ASOAP SOLUTION. NEVER USE AMATCH OR OPEN FLAME. CORRECT ANY LEAK, NO
MA'I-rER HOW SMALL.
G. IMPORTANT_ PIPING SUPPLY SHALL BE SUPPORTED TO PREVENT SAGGING DAMAGE TO CONTROLS AND
HAZARDOUS GAS LEAKS. TO PREVENT FREEZING WHERE THE SUPPLY PIPE IS EXPOSED TO COLD AIR,
WRAP THE PIPE OR RUN IT UNDERGROUND.
DROP
I1PIPED (;_OUN0 JOINT
IIGAS u.loN
_PIPED
_INI_UM__IRI_PuG_J,n176 _ mini _NIPPLE GAS
_UAL SHUt 0f_ SUPPLY
tEE
Nippt E
• ],_ I;6 Z n._,l
s
'i(,°2
' I
I I _<. cAP
MINlP,¢UM
,_ALt 81[NO_ 4_ Ml_Zat,i C IUHlld G S.OULD 0[ SMOOIH
/_ CAUIION SMUT OC, rt_. MA_ ._._ _UOI_.=V BCFOR_ N(MOVII_G (NO CAP
rO P_EVI_N_ Ga_ fROM _ _LL_tlC ! .[ WORK Ag_A _T FON GAS L_AK
IMPORTANT
All piping must comply with local codes and ordinances
or with the National Fuel Gas Code (ANSI Z223.1 NFPA
No. 54), whichever applies. (In Canada: CAN/CGA B149.)
PROPER PIPING PR_rlC_
IMP(RF[CT CONTRO L USI_ MOO(RAT( AMOUNT OF DOPE
THR£AD P_P_ R_T L_N_T_ L_V_ _ _O TH_£AD$ _R_ _
TOP
LEFT
SIDE
350 MODEL SERIES SHOWN
Fig. 2 Rg. 3
---6--
.WARNING
DANGER OF ILLNESS
BODILY INJURY OR DEATH
THE FURNACE AND ANY OTHER FUEL BURNING
APPLIANCE MUST BE PROVIDED WITH ENOUGH
FRESH AIR FOR PROPER COMBUSTION AND
VENTILATION OF FLUE GASES. MOST HOMES
WILL REQUIRE THAT OUTSIDE AIR BE SUPPLIED
INTO THE FURNACE AREA.
WARNING
DANGER OF PROPERTY DAMAGE,
BODILY INJURY OR DEATH
EVEN WHEN HOUSE MEETS REQUIREMENTS
FOR UNCONVINED SPACE WITH ADEQUATE AIR
INFILTRATION IT IS RECOMMENDED THAT A
FRESH AIR INTAKE BE INSTALLED TO LESSEN
THE POSSIBLE DANGERS FROM ANY FUTURE
CHANGES ON THE HOME.
VENTING
WARNING: This heater is equipped with a vent safety shut-off system to protect against improper venting of its combus-
tion products. Tampering with or removal of this control will void the limited warranty and can result in carbon monoxide
(CO) poisoning and possible death.
A. An effective flue is necessary to carry off water vapor, carbon monoxide (CO), carbon dioxide (CO2), and other
products of combustion. For proper venting, follow the following basic rules for gravity venting, which are:
S.
C.
D.
1. Keep the flue gases hot.
2. Follow the vent manufacturer's installation instructions.
3. Select the proper vent size.
4. Provide constant fresh air replacement.
For new installation, it is recommended that a Type "B" vent in accordance with its listing be used. A Type "B"
vent is one made of non-combustible, corrosion resistant material of sufficient thickness and cross sectional area
and heat insulating quality to avoid excess temperature on adjacent combustible material and certified by a na-
tionally recognized testing agency. Existing brick flues should be lined to provide an effective vent. Brick chimneys,
even in good repair, may be too large and will not provide sufficient draft to effectively vent a heater.
Use vent pipe of the same size as the outlet on back of heater. In no case should asmaller vent be used.
Avoid ahorizontal run of vent pipe whenever possible. When a horizontal run is necessary, the pipe must pitch
upward at least 1/4"to the foot, and must be supported securely and joints fastened by sheet metal screws or rivets.
Under no circumstances should the vent run downhill.
E. Never put a damper or barometric draft control in a gas vent pipe.
F. Never end a vent in an open attic or run vent through a wall to the outside without extending it upward above the roof.
G. Always terminate vent with an approved cowl.
H. WARNING: ALWAYS SECURE VENT PIPE TO OUTLET ON BACK OF HEATER WITH A SHEET METAL SCREW.
IMPORTANT:
Inspect venting system prior to each heating season.
WARNING
DANGER OF ILLNESS,
BODILY INJURY OR DEATH
DRAFTHOOD SPILLAGE WITH UNOBSTRUCTED
VENTS, INDICATES THAT ADDITIONAL AIR MUST
BE BROUGHT INTO THE STRUCTURE FROM THE
OUTSIDE. KEEP A WINDOW OPEN (MINIMUM 2
INCHES) NEAR THE APPLIANCE UNTIL APER-
MANENT AIR DUCT IS INSTALLED.
I WARNING: DANGER OF PROPERTY DAMAGE, BODILY INJURY OR LOSS OF LIFE. DO NOT INSTALL FURNACE
IN ANY AREA WHERE OXYGEN IS IN USE.
--7--
Thermostat Installation
Models with the last two digits "11" (or) "12" utilize a built-
in thermostat control system operated by a heat sensing
bulb located in the burner compartment.
IMPORTANT
I andle the bulb with care. Do not kink the connec-
ting tubing.
Models with the last two digits "21" (or) "22" are operated
by a millivolt type thermostat. Current to the thermostat
is supplied by the pilot generator. Anticipation settings are
not required.
1. If an old thermostat is being replaced and is in a
satisfactory location and the wiring appears to be in
good condition, use existing wiring. If in doubt, use new
wire.
2. If anew location is chosen or if this is a new installa-
tion, thermostat cable must first be run to the location
selected. All wiring must agree with local codes and
ordinances. These instructions cover bringing the wire
down from the attic but it can be run from a basement
or crawl space using similar methods.
3. Before drilling hole in wall at selected location, drive
a small finishing nail through the ceiling in the corner
of the wall and ceiling above the thermostat location.
Pull the nail out and push a small stiff wire through the
hole so it can be found in the attic. Drill a 1/2-inchhole
through the ceiling wall plate.
4. Probe for obstructions in the partition. Then drill a
1/2-inch hole through wall at selected location for
thermostat.
5. From the attic, feed the thermostat cable or a stiff wire
through wall until even with thermostat location.
6. Snag thermostat cable through hole and pull cable
through hole in wall so that 6 inches of cable protrubes.
7. Route cable to heater.
MOUNTING THE THERMOSTAT
1. To remove thermostat cover, squeeze both sides and
lift.
2. Connect thermostat wires to the thermal screws on the
back of thermostat base.
,
4.
Push any excess wire back through hole in wall and
plug hole with insulation to prevent drafts from affect-
ing thermostat operation.
Be sure to level thermostat for best appearance, fasten
thermostat base to wall through mounting holes with
screws provided.
5. Replace the thermostat cover.
CAUTION
Do not run wire in any location where it might be
damaged. Avoid slicing thermostat wire unless the
spliced wires are properly cleaned, soldered and
taped.
NOTE
Use #18 Ga. wire as supplied for maximum length of 20
feet. If longer length is needed, use #16 Ga. for maximum
length of 25 feet.
Refer to installation instructions packed in the thermostat
carton if you have any doubt about the above procedures.
Connect thermostat wire, previously run to burner com-
partment from thermostat, to control valve as shown in
Fig. 4.
CAUTION
LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OP-
ERATION. VERIFY PROPER OPERATION AFTER
SERVICING.
THERMOSTAT GENERATOR
€---WHITE BLUE
KNOB
WILLIAMS
LIMIT SWITCH P172100A (OR)
P172200A
J GENERATOR THERMOSTAT LIMIT SWITCH
GREEN KNOll
WILLIAMS
P295000A (OR}
P295001A
Fig. 4
--8--
Start-Up Procedure
WARNING
DANGER OF PROPERTY DAMAGE,
BODILY INJURY OR DEATH.
LIQUEFIED PETROLEUM L.P. GAS IS HEAVIER
THAN AIR AND IT WILL SEI-rLE IN ANY LOW
AREA, INCLUDING OPEN DEPRESSIONS AND IT
WILL REMAIN THERE UNLESS AREA IS
VENTILATED.
NEVER ATTEMPT STARTUP OF UNIT BEFORE
THOROUGHLY VENTILATING AREA.
Check the heater operation as outlined in the following in-
structions. If any sparking, odors or unusual noises are
encountered, shut off electric power immediately. Recheck
for wiring errors, or obstructions in or near fan motor (if
equipped).
CHECK GASINPUT AND PRESSURES
For heater located at elevations between sea level and
2000 feet, the measured input must not be greater than
the input shown on the rating plate of the furnace. For
elevations above 2000 feet, the measured input must not
exceed the input of the rating plate reduced by 4 percent
for each 1000 feet that the heater is above sea level.
Gas supply pressure and manifold pressure with the
burner operating must also be as specified on the rating
plate.
lype of Gas Manifold Pressure, In. W.C.
Natural 4
L.R 10.5
Rated input will be obtained on 2500 Btu propane at 10.5
inch manifold pressure and factory-sized orifices. If LP gas
having a different heating value is supplied, orifices must
be changed by a qualified service technician before the
heater is operated.
CHECK THE MANIFOLD GAS PRESSURE
A tapped opening is provided in the gas valve to facilitate
measuring the manifold gas pressure. A "U Tube"
manometer having a scale range from 0 to 12 inches of
water should be used for this measurement. The manifold
pressure must be measured with the burner and pilot
operating. Any major changes in the flow must be made
by changing the size of the bumer orifice. Check with your
WILLIAMS service department for proper orifice sizing.
CHECK THERMOSTAT
Check thermostat operation. When set above temperature
shown on the thermostat, the main burner should light.
Make certain the thermostat turns off the heater when
room temperature reaches the selected setting and starts
the heater when room temperature falls a few degrees.
CHECK THE GAS INPUT (NATURAL GAS ONLY)
WARNING
NATURAL GAB HEATING VALUE (BTU PER CUBIC
FOOT) CAN VARY SIGNIFICANTLY, THEREFORE,
IT IS THE INSTALLER'S RESPONSIBILITY TO BEE
THAT BTU INPUT TO THE FURNACE IS ADJUSTED
PROPERLY. FAILURE TO DO SO COULD CAUSE
HEAT EXCHANGER FAILURE, ASPHYXIATION, FIRE
OR EXPLOSION, RESULTING IN DAMAGE, BODILY
INJURY OR DEATH. REFER TO THE NATURAL
FUEL GAS CODE (NFPA-54) TO BE SURE THE FUR-
NACE IS BURNING FUEL AT THE PROPER RATE.
Underfiring could cause inadequate heat, excessive con-
densation or ignition problems. Overfiring could cause
sooting flame impingement or overheating of heat ex-
changer.
Before starting natural gas input check, obtain heating
value of gas (BTU per cubic foot) at standard conditions
from your local supplier. This factor is used in "Check the
Gas Input" section and procedure.
To measure the input using the gas meter, proceed as
follows:
Step 1: Turnoff gas supply to all other appliances except
the furnace.
Step 2: With the heater operating, time the smallest dial
on the meter for one complete revolution. If this
is a 2cubic foot dial, divide the seconds by 2; if
it is a1 cubic foot dial, use the time in seconds
as is. (3,600 =Sec. Per Hr.) This gives the
seconds per cubic foot of gas being delivered to
the heater.
Step 3: Assuming natural gas with a heating value of
1000 Btu per cubic foot and 34 seconds per cubic
foot as determined by step (2), then:
Input: 1,000 X 3,600 + 34 = 106000 Btu Per Hour
Step 4:
This measured input must not be greater than the
input indicated on the rating plate of the heater.
Relight all other appliances turned off in step 1
above. Be sure all pilot burners are operating.
CHECK PILOTBURNER
The pilotflame must envelop 1/2 to 5/8 inch of thermocou-
pie or generator. See Fig. 5. Pilot flame is preset at the
factory, so ordinarily does not require field adjustment. If
adjustment is needed, see page 14.
J__
1/2 TO5/s ,_-- RLOT
FRONT
_EW
--9---
Fig. 5
FOR YOUR SAFETY, READ BEFORE LIGHTING
WILLIAMS GAS CONTROL VALVE P322051 (OR) P322052 (OR) P500419 (OR) P5004_,0
r WARNING: If you do not follow these instructions exactly, a fire or explosion I
may result causing property damage, personal injury or loss of life, I
A. This appliance has a pilot which must be lighted by
hand. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING smell around the appliance ares
for gas. Be sure to smell next to the floor because some
gas Is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• DO not touch any electric switch; do not use any
phone In your building.
•Immediately cell your gas supplier from s neighbor's
phone. Follow the gas suppller's instructions.
C,
D.
•If you cannot reach your gas supplier, call the fire
department.
Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
tom by hand, don't try to repair it, call € qualified serv-
ice technician. Force or attempted repair may result In a
flro or explosion.
Do not use this appliance If any part has been under
water, immediately call s qualified service technician to
inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
OPERATING INSTRUCTIONS
1. STOP! Read the sefety information above.
2. TOm off all electric power to the appliance (if applicable).
3. Open control access panel.
4. Tom temperature dial clockwise F_ to "LO'"
5. Push in gas control knob slightly and turn
olookwlee !-_ to "OFF."
TEMPERATURE
DIAL GAS CONTROL
"'_@._:/_--"_@1 _ @1/KNOB SHOWN
"_'F/_ \l F_',_%'_/_ IN OFF
NOTE: Knob cannot be turned from "PILOT" to "OFF"
unless knob Is pushed in slightly. Do not force. 11.
6. Welt five (5) minutes to clear out any gas, then smell for
gas, including near the floor, if you then smell gas, stopl 12.
Follow "B" in the safety Information above. If you don't
smell gas, go to next step.
7. Loosen wlngnut end open the pilot observation door (if 13.
equipped). 14.
8. Find pilot--follow metal tube from gas control. The pilot is
mounted on side of burner.
9. Push In gas control II _
knob slightly and turn
counterclockwise
to "PILOT."
10. Push in control knob all the
way end hold In. Immediately THERMO- PILOT
light the pilot. COUPLE BURNER
Continue to hold the control knob In for about one (1)
minute after the pilot is lit. Release knob end It will
pop back up. Pilot should remain lit. If It goes out,
repeat sfop$ 5 through 10.
•If knob does not pop up when released, stop and
Immediately ceil your service technician or gas
supplier.
•If the pilot will not stay lit after several tries, turn
the gas control knob to "OFF" and call your service
technician or gas supplier.
Close pilot observation door, tighten wingnut
(if equipped).
Torn gas control knob counterclockwise _'_ to "ON':
Sensing bulb is now activated. Set temperature dial to
desired temperature (1 - 5).
Close control access panel.
Torn on all electric power to the appliance
(if applicable).
TO TURN OFF GAS TO APPLIANCE
1. Turn off all electric power to the appliance If serv-
Ice is to be performed (if applicable).
2. Open control access panel.
3. Push In gas control knob slightly and tum
clockwise F-_ to "OFR" Do not force.
4. Close control access panel.
WARNING: DUE TO HIGH SURFACE TEMPERATURES -- KEEP CHILDREN, CLOTHING,
FURNITURE OR ANY COMBUSTIBLE MATERIAL AWAY FROM FURNACE.
IMPORTANT: KEEP BURNER AND CONTROL COMPARTMENT CLEAN.
CONNECTION WIRING DIAGRAM FOR BUILT-IN THERMOSTAT MODELS
SHUT OFF 0E-_IC_ -
BLACK
BLACK
GAS VALVE
RE]_OTE BULB
LZGE_O
-- FACTORY WIRED LOW VOLTAGE
NOTES: Fk_Y 0F 1_ 01_lU_. NR[ _
€[ m'LAC_ US[O_y t_. 4,_,
IK_JI,,A'nG_1G6".C.AW
vm[ oR I_/JIVAL_T.FORRDD.
_Cml_llo_ us[ NO,18A_O
m _lZO mt ATZZ_TI_ (:ml-)
--10--
Im ..u,tc.us,., or,o.o,,i. I
A. This appliance has a pilot which must be lighted by
hand. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING smell around the appliance area
for gas. Be sure to smell next to the floor because some
gas Is heavier than sir and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appllancs.
•Do not touch any eieotdc swifch; do not use any
phone In your building.
•Immediately cell your gas supplier from s neighbor's
phons. Follow the gas suppiier's Instructions.
C.
D°
•If you cannot reach your gas supplier, call the fire
department.
Use only your hand to push In or turn the gas control
knob. Never use tools. If the knob will not push in or
tum by hand, don't try to repair it, ceil n qusiified serv-
Ice tochnlcien. Force or attempted repair may result In a
fire or explosion.
Do not use this appliance if any part has been under
water. Immediately cell n qusliflnd asrvlce tochniclcn to
Inspect the appliance and to replace any part of the
control systom and any gas control which has been
under mr.
OPERATING INSTRUCTIONS
1. STOP! Resd.the safety Information above.
2. Turn off all electric power to the appliance (if applicable).
3. Open control access panel.
4. Push In gas control knob slightly and turn
clockwlse/-"_ to "OFF." TEMPERATURE DIAL
KNOB SHOWN
IN "OFF"
POSITION
NOTE: Knob cannot be turned from "PILOT" to "OFF"
unless knob 18 pushed in slightly. Do not force.
5. Wait five (5) minutes to clear out any gas, then smell for
gas, Including near the floor. If you then smell gas, sfopi
Follow "B" In the safety Informstlon above. If you don't
smell gas, go to the next step.
6. Loosen wlngnot and open the pilot observation door (It
equipped).
7. Find pilot--follow metal tube from gas control. The pilot is
mounted on side of bumer.
8. "Ibm knob on gas control N
counterclockwlas
to "PILOT."
9. Push In control knob all the
way and hold in. Immediately
light the pilot. THERMO- PILOT
COUPLE BURNER
Continue to hold the control knob in for about one (1)
minute sitter the pilot Is lit. Release knob and it will pop
back up. Pilot should remain lit. If it goes out, repast steps
5 through 9.
•If knob does not pep up when released, stop and
Immedlntoly cell your service technician or gas
supplier.
•If the pilot will not stay lit after several tries, turn
the gas control knob to "OFF" and cell your service
technfolnn or gas supplier.
10. Close pgot olmervation door, tighton wlngn_ (if equipped).
11. Turn gas control knob counterclnckwlasl( _to "ON".
Burner Is now under control of the thermostatic canning
element. Tum temperature dial (numbered 1 through 8)
counterclockwise I_ toward 8 to obtain desired
temperature.
12. Close control socese panel.
13. "rum on MI electric power to the appliance
(If ppgWlcehlo).
TO TURN OFF GAS TO APPLIANCE
1. Tum off ell electric power to the appliance If serv-
Ice Is to be performed (if applicable).
2. Open control access panel.
3. Push In gas control knob slightly end turn
clockwise _to "OFF." Do not force.
4. Close control access panel.
WARNING: DUE TO HIGH SURFACE TEMPERATURES -- KEEP CHILDREN, CLOTHING,
FURNITURE OR ANY COMBUSTIBLE MATERIAL AWAY FROM FURNACE.
IMPORTANT: KEEP BURNER AND CONTROL COMPARTMENT CLEAN.
DIAGRAM FOR BUILT-IN THERMOSTAT MODELS
CONNECTION WIRING
VENT _ I--I]]'ERMOCOUPLE
-%_UT OFF OE'VIC_ U.[_
BLACK
GAS VALVE I-- FACTORY_RED LOWVOLTAG_
NO'W.S:WAHYOF 15EO_NAL _ AS
_PP_9 _ IH£N=RJ/_¢[INSl"
Ik_l.A'lION,1_" @.AWM¢¢PP£R
_ CG_I4_'I]G_SIJE NO,10 A14_
R_OTE BULB
_11_
FOR YOUR SAFETY, READ BEFORE LIGHTING
WILLIAMS GAS CONTROL VALVE P172100A & P172200A
WARNING: If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by
hand. When lighting the pilot, follow these Instructions
exactly.
B. BEFORE LIGHTING smell around the appliance area
for gas. Be sure to smell next to the floor because some
gas Is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
•Do not touch any electric owltch; do not use any
phone In your building.
•Immediately call your gas supplier from aneighbor's
phone. Follow the gas suppller's Instructions.
C.
B,
•It you cannot reach your gas supplier, call the fire
department.
Use only your hand to push In or turn the gas control
knob. Never use tools. If the knob will not push In or
turn by hand, don't try to repair It, call e qualified serv-
Ice technician. Force or attempted repair may result In a
fire or explosion.
Do not use this appliance If any part has been under
water. Immediately call a qualified service technician to
Inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
OPERATING INSTRUCTIONS
1. STOPI Read the safety information above.
2. Turn off ell electric power to the appliance (If applicable).
3. Set the thermostat to lowest setting.
4. Open control access panel.
5. Push In gas control knob slightly and tum
clockwlseF-_, to "OFF."
GAS CONTROL
jKNOB SHOWN
IN "OFF" POSITION
NOTE: Knob cannot be turned from "PILOT" to "OFF"
unless knob Is pushed in slightly. Do not force.
6. Walt five (5) minutes to clear out any gas, then smell for
gas, Including near the floor. If you then smell gas, STOPI
Follow "B'" In the safety Informstlon above. If you don't
smell gas, go to the next step.
7. Loosen wlngnut and open the pilot observation door (if
equipped).
8. Find pilot--follow metal tube from gas control. The pilot Is
mounted on side of bumer.
GENERATOR _
9. Push In gas control
knob slightly and turn
counterclockwise _'_
to "PILOT" PILOT
10. Push In control knob ell the way and BURNER
hold in. Immediately light the pilot.
Continue to hold the control knob In for about one (1)
minute after the pilot Is lit. Release knob and it will
pop back up. Pilot should remain lit. If It goes out,
repeat steps 5 through 10.
•If knob does not pop up when released, stop and
Immediately call your service technician or gas
supplier.
• If the pilot will not stay lit after several tries, turn
the gas control knob to "OFF" and call your service
technician or gas supplier.
11. Close pilot observation door, tighten wlngnut
(if equipped).
12. Tumgsecontrolknobcountercloukwlse,rF"_to"ON ''.
13. Close control access panel.
14. "rum on ell electric power to the appliance
(if applicable).
15. Set thermostat to desired setting.
TO TURN OFF GAS TO APPLIANCE
1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance if service Is to be performed.
3. Open control access panel.
4. From "ON" position, depress and turn gas control knob clockwise F_ to "OFF" position. Do not force.
5. Close control access panel.
WARNING: DUE TO HIGH SURFACE TEMPERATURES -- KEEP CHILDREN, CLOTHING,
FURNITURE OR ANY COMBUSTIBLE MATERIAL AWAY FROM FURNACE.
IMPORTANT: KEEP BURNER AND CONTROL COMPARTMENT CLEAN.
CONNECTION W1RING DIAGRAM FOR WALL THERkiOSTAT MODELS
LEGEND
-- FACTORY WIRED LOW VOLTAGE
(_ SCR'L"W TERMINAL LOW VOLTAGE
NOTE: IF ANY OF 1HE ORIGINAL_AS
SUPPt,RDt_IIf l},lEAR=UA,'MCE_
E _ u_ ONlYt_ 4/04
_qul_0_. 106"_ AWM00PP_
W_ 0R I_LWN._T. FOR RB.D -
_RSl) CONN_I014S USE NO. 111A_
ames_1_ _ ATt.F.ASTtOS'C{_n_
--12--
WARNING: If you do not follow these instructions exactly, afire or explosion I
may result causing property damage, personal injury or loss of life. I
A. This appliance has a pilot which must be Ughted by
hand. When lighting the pilot, follow these Instructions
exactly.
B. BEFORE LIGHTING smell around the appliance area
for gas. Be sure to smell next to the floor because some
gas Is heavier than air end will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance.
•Do not touch any electric switch; do not use any
phone In your building.
•Immedlatsiy rail your gas supplier from a neighbor's
phone. Follow the gas soppller'a Inxtroctlona.
• If you cannot reach your gas supplier, call the fire
department.
C. Use only your hand to push In or turn the gas control
knob. Never use tools. If the knob will not push In or
turn by hand, don't try to repair It, call a qualified aerv-
Ice technician. Force or attempted repair may result In a
fire or explosion.
B. Do not use this appliance If any part has been under
water. Immediately call aqualified service technician to
Inspect the appliance end to replace any part of the
control system end any gas control which has been
under water.
OPERATING INSTRUCTIONS
1. STOPI Read the safety Information above.
2. Bet the thermostat to lowest setting.
3. Turn off all siectrlc power to the appliance. (If applicable).
4. Remove control access panel.
5. Push In gas control knob slightly and turn
clockwise F_ to "OFF."
.sCONTROL
t/ __ \_1 t"-'_;_ KNOB SHOWN
'"OFFPOSITION
NOTE: Knob cannot be turned from "PILOT" to "OFF"
unless knob Is pushed in slightly. Do not force.
6. Walt five (5) minutes to clear out any gas, then smell for
gas, Including near the floor. If you then smell gas, atopl
Follow "B" In the safety Information above. If you don't
smell gas, go to the next step.
7. Loosen wlngnut and open the pilot observation door (If
equipped),
8. Find pnot--follow metal tube from gas control. The pilot Is
mounted on side of burner.
9. Turn knob on gas control
counterclockwise
to "PILOT."
GENERATOR PILOT
BURNER
10. Push In control knob all the way end hold In. Immedi-
ately light the pilot.
Continue to hold the control knob In for about one (1)
minute after the pÁÁÙtIs lit. Release knob end It will pop
back up. Pilot should remain lit. If It goes out, repeat
steps 5 through 10.
• If knob does not pop up when released, stop and
Immedlataty call your service technician or gas
supplier.
•If the pilot will not stay lit after several tries, turn
the gas control knob to "OFF" and call your service
technician or gas supplier.
11. Close pilot observation door, tighten wlngnut
(If equipped).
12. Turn gas control knob counterclockwise _'_ to "ON".
13. Close control access panel.
14. Turn on all electric power to the appliance (if applicable).
15. Set thermostat to desired setting.
TO TURN OFF GAS TO APPLIANCE
1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance If service Is to be performed.
3. Open control access panel.
4. Push In gas control knob slightly and turn clockwise F_ to "OFF" pesltlon. Do not force.
5. Close control access panel.
WARNING: DUE TO HIGH SURFACE TEMPERATURES mKEEP CHILDREN, CLOTHING,
FURNITURE OR ANY COMBUSTIBLE MATERIAL AWAY FROM FURNACE.
IMPORTANT: KEEP BURNER AND CONTROL COMPARTMENT CLEAN.
CONNECTION WIRING DIAGRAM FOR WALL THERMOSTAT MODELS
V ENT SAFETTH E_.._ TAT _-] GENERATOR
SHUT OFF DEVICE1 _ -I I I
/ BLACK
GAS
VALVE
LEGENO
1 FACTORY WIRED LOW VOLTAGE
SCREWTERMINAL LOW VOLTAGE
_1_ IF ANY OF 11tE 0RIGINAL Y&_E AS
_tlrD.I 11tE ,N,RJ/gI(Z MUST
ERER,AC_),USEONLYtlIQ,_,4,4H
INSULA'IIaN,106"_Al_l
_R£ ORI_IVN.B_T. F0RRELD-
tfRB)_USENO.18AI_
'lq9 w,'rm_ ATtL_r tes,c(_w)..
--13---
How To Care For Your Heater
CABINET FINISH
Clean cabinet with damp rag. Never use abrasive cleaners.
Cabinets are finished with heat resistant baked enamel
-- DO NOT refinish with wall paint.
REMOVABLE CABINET TOP (350, 500, & 650 MODEL
SERIES ONLY)
For ease of cleaning, access or replacement of internal
parts, the top of this heater can be removed by following
these steps: Refer to Fig. 6.
1. Remove (3) Bracketson roar of heater securing Cabinet
Top to Back Plate.
2. Pull Cabinet Top forward and lift up. Reinstall Cabinet
Top by reversing the procedures noted above.
NOTE: Take Special care to engage the (6) clips located
on the bottom of the Cabinet Top into the top flange of
heater sides.
HEATER AREA
Keep the area near the heater clear and free from com-
bustible materials, gasoline, and other flammable liquids
and vapors.
COMBUSTION AND VENTILATION AIR
The combustion and ventilation air supply must not be
blocked
Do not put anything in or on the heater cabinet.
For better circulation and more effective heating, do not
place obstructive furniture closerthan four feet to the front
of the cabinet or two feet to the side of the cabinet.
CLEANING BURNER COMPARTMENT
Because cold air is attracted to the flame during furnace
operation, abuild up of lint from bedding and dust (etc.)
in the burner area will occur each heating season. It is
necessary to clean this area regularly. Use a vacuum
cleaner with a narrow attachment to reach small areas.
Be careful in and around the pilot. A change in its adjust-
ment could be made if struck during cleaning.
DANGER
A BUILDUP OF ANY DUST, LINT OR FOREIGN
MATERIAL IN THE PARIMARY AIR OPENING OF
THE BURNER CAN INTERFERE WITH THE PRO-
PER AIR GAS MIXTURE AND CAN RESULT IN A
YELLOW FLAME WHICH CAN PRODUCE CAR-
BON MONOXIDE AND SOOT. THIS CONDITION IF
ALLOWED TO DEVELOP, CAN LEAD TO BODILY
INJURY INCLUDING DEATH. IT IS IMPERATIVE
THAT THE BURNER BE KEPT CLEAN.
REMOVABLE CABINE'r TOP
(350, 500, & 650 MODEL SERIES)
*NOTS:
(3) BRACKETS -- TO REMOVE CABINET TOP.
REMOVE (3) BR._CKETS
ON REAR OF HEATER.
CABINET PULL CABINET TOP FORWARO
TOP -_ AND LIFT UF_
\
ANNUAL UPKEEP NEEDED
It'is recommended that a qualified service technician per-
•form these checks st the beginningof each heating season.
TABS
CLEANING BLOWER (if equipped)
Shut off electricity. Clean any lint or dirt from fan blades,
fan motor, and exposed air passages. Use a brush.
PILOT BURNER
Light pilot using instructions in OPERATING YOUR FUR-
NACE on pages 10through 13. Leave thermostat at lowest
setting.
Pilot flame should surround 1/2 to 5/8 inch of the generator
or thermocouple tip. Refer to Fig. 5, page 9. If flame needs
adjusting, do so as follows:
ADJUST PILOT BURNER Refer to Fig. 7.
1. Remove screw cover over pilot adjusting screw.
2. Insert small screwdriver. Adjust flame as needed. Turn
screw counterclockwise (_"_) to increase flame,
clockwise (r'_) to decrease.
3. "rumthermostat to highest setting. Main burner should
light quickly and smoothly.Turn thermostatto lowestset-
ting. Main burner should go out. Pilotshould remain lit.
4. Replace screw cover with gasket over pilot adjusting
screw.
BURNER CLEANING
Check burner. If cleaning is required, contact a qualified
service technician to clean and service burner.
SIDE
Fig. 6
VENT SYSTEM
Make sure that no parts of the venting system are block-
ed or rusted. Clean or replace before using furnace.
"i'
• G
TOP VIEW
I
SIDE VIEW
Flg. 7
NOTE: A properly adjusted bumer with nearly all gases will produce aflame which has clear blue cone having
abluleh.red or bluish-violet outer mantle. In the case of PURE BUTANE GAS, avery slightly yellow tip (Y4" max-
Imum length) Is usually present.
--14---
INSTALLATION & OPERATING INSTRUCTION
2101 BLOWER ACCESSORY
(AVAILABLE ONLY FOR 350, 500, & 650 MODEL SERIES)
WARNING
NOTE:All electrical work must be conform to your local
codes and ordinances or in their absence, with
National Electrical Code,ANSI/NFPA 70. If
you are not famnlar with wtdng codes In general,
haveacompetentdectrlclando this job. in CANADA
CANADIANELECTRICALCODEC22.1.
DANGEROF PROPERTYDAMAGE,BODILYINJURY
OR DEATH.]URN OFFElECTRiCALPOWERSUPPLY
AT DISCONNECTSWITCH,FUSEBOX OR SERVICE
PANEL BEFOREREMOVINGOR WORKINGFAN.
L (EXAMPLE I)
650 SERIES
500 SERIES
B
EXAMPLE 2)
350 SERIES
FIG,1 .A
A. BLOWER ACCESSORY KIT INSTALLATION
WARNING: This appliance
is equipped with athree-
prong (grounding) plug for
/our protection against
shock hazard and should
be plugged directly into a
)roperly grounded three-
prong receptacle.
DO NOT CUT OR REMOVE
THE PRONG. Oil motor every
6 months with a few drops
of SAE 20 motor oil.
A: MOTOR & BLOWER
B: GAS VALVE
C: CONDUIT
D: CONTROL ROD
E: CABLE CLAMP
F: CORD & PLUG
G: CONTROL BOX
H: TEMPERATURE DIAL
J: BLOWER SPEED
SELECT SWITCH
K: FAN LIMIT SWITCH
L: SENSOR MOUNTING
BRACKET
M: SPILL SWITCH
N: COUPLING
This accessory is installed on heater back and will increase circulation of warm air
through heated space. A115V 60Hz outlet adjacent to the furnace is required,
NOTE: WALl THERMOSTAT MODELS ONLY
Control Rod (D), Temperature Dial (H), and Coupling (N) are not used or supplied
with Wall Thermostat Models. Wall Thermostat Models utilize a mlllivolt Thermostat
for Temperature Control. For Wall Thermostat Model installations, disregard STEPS 3
and STEP 4on these instructions.
INSTALL AS FOLLOWS:
STEP 1. Choose a location for heater installation near 115v electrical outlet (within
5 feet to rear of heater.)
STEP 2. Place motor &blower (A) on heater floor, securing with (4) screws as shown
in RG.1. Also place control box (G) near the top of furnace back, securing with
(21 screws as shown In RG.1.
(NOTE: Install this klt by using the holes in cabinet only.)
STEP 5. Attach temperature dlal (H) to hole free end of control rod (D). Tighten set
screw and set assernby aside for now.
--15--
INSTALLATION
(con't)
STEP 4.
&OPERATING INSTRUCTION
21 01 BLOWER ACCESSORY
Remove temperature dial from control valve (B) and discard. Install the
coupling (N) to control valve and secure it by tightening set screw.
Slide previously assembled control rod down through control box and insert
it into coupling attached to the control valve. Secure rod to couplincj with
cotter pin.
STEP 5. Secure cable clamp (El to the heater, as shown in FIGURE 1, with screw
provided.
STEP 6. (Refer to RG.1 page 151 Insert fan sensor switch, attached to fan limit
switch (K), into sensor mounting bracket (L) as shown in FIG.1.
See correct bracket location for your model in example 1and 2.
IMPORTANT: When inserting sensor bulb into mounting bracket be careful
not to push bulb compleUy thru mounting bracket, stopping before sensor
switch tip is exposed at other end of bracket. When installing sensor switch
into mounting.bracket be sure sensor bulb is not touching spill switch
connectors (M).
B. BLOWER OPERATION
I. With heater cold (allow to cool if heater has been operating), insert plug (F)
into available 115volt wall outlet.
2. Turn heater on and allow to operate 10 minutes.
3. Set blower speed select switch (J) to either "LO" or "Hi" position to obtain desired
air movement. (Blower accessory will not operate if blower speed select switch is
set in "OFF" position.)
4. For Built-In type Thermostat Models, turn Temperature Dial (H) to desired
tamp settings. For Wall type Thermostat Models turn Wall Thermostat Dial to
temperature settings.
5. To turn off blower, set blower speed select switch (J) to "OFT" position.
WIRING DIAGRAM
LEGEND
21 01 BLOWER ACCESSORY
LI
115VA¢ _"I
I I
-- CAUTION
Label all wires prior to dis-
connection when servicing
controls. Wiring errors con
cause improper and danger-
ous operation. Verify proper
operation after servicing.
'--' HIGH VOLTAGE FIELD
...... HIGH VOLTAGE FACTORY
0WIRE CONNECTORFOR UNE VOLOTAGE
FACTORY WIRING
BK-BLACK BL==BLUE W==WHITE R-RED G==GREEN
NOTE: IF ANY OF THE ORIGINALWIRE AS SUPPLIEDWITHTHE
APPLIANCEMUST BE REPLACED,USE ONLY 18GA, 4/64"
INSULATION,105"C. AWM COPPERWIRE OR EQUNALENT.
FOR FIELD WIREDCONNE:Cl]ONSUSE NO. 18 AWG WIRES
RA'I'_D FOR AT LEAST 105"C (991"_
--16--
INSTALLATION & OPERATING INSTRUCTION
2101 - BLOWER ACCESSORY
-REPLACEMENT PARTS -
(350, 500, &: 650 MODEL SERIES ONLY)
0
13 17
2
3
NO._._ ITEMS 5,6,7, &16 ARE NOT
SUPPUED OR REQUIRED Y,IIH
WAll TYPE THERMOSTAT MODELS
ITEM
NO.
1
2
3
4
5
6
7
8
9
11o
PART NO.
P500250
K7003-6087
P500137
K5150-6029
SEE P_ _
18
P500125
P500026
P500156
P500158
P097500
-REPLACEMENT
(USE ONLY MANUFACTURES
DESCRIPTION
ASSEMBLY, MOTOR
PLATE, MOTOR MTG.
BLOWER WHEEL
ASSY, BLOWER HOUSING
CONTROL ROD
COTTER PIN
GROMMET, WHITE
CORD &: PLUG
BUSHING - STRAIN
!SCREW, _t_B-32 X 3/8
PARTS LIST -
AUTHORIZED PARTS)
ITEM
NO.
11
12
13
14
15
16
17
18
19
20
PART NO. DESCRIPTION
P500263 FAN UMIT SWITCH
(000062 BASE, CONTROL BOX
P065800 SCREW, #10 X 1/2
K000061 WRAPAROUNDCON'IROL BOX
P320911A SPEED SELECT SWITCH
SEE PAGE 21
rr_ =4 TEMPERATURE DIAL
P50014,5 SET SCREW, BOX CON.
K000143 CABLE CLAMP
PARTOF FURNACE SENSOR MOUN1]NG BRACKET
PARTOF FUB_ACESCREW, _ X 3/8 S.M.
NO'W.: Screws, bolts end woshers ore _endla'd hll,'dware Rims end moy be purchosed locally,
--17--
WILLIAMS GAS FIRED ROOM HEATER
REPLACEMENT PARTS FOR
20016 MODEL SERIES
j"
.j"
I
i
I
I
I
I
I
J
I
•I
FOR PARTS UST
SEE PAGE 19
USE ONLY MANUFACTURER'S
AUTHORIZED PARTS
--18---
REPLACEMENT PARTS FOR MODELS
2001611 2001612 2001621 2001622
!KE'_ DESCRIPTION
NO. 2001611 2001612 2001621 2001622
1 WRAPPER ASSEMBLY K000275 K000275 K000275 K000275
2 DRAFT DIVERTER ASSY. K000274 K000274 K000274 K000274
COMBUSTION CHAMBER
3 KOOO27g K000279 K000279 K000279
ASSEMBLY
4 BASE PLATE K000265 K000265 K000265 K000265
5 VALVE BRACKET K000266 K000266 K000266 K000266
6 CONTROL VALVE P322052 P322051 P172200A P172100A
7 BURNER ASSEMBLY K000301 K000301 K000301 K000301
8 ORIRCE ADAPTER P500393 P500393 P500393 P500393
9 BURNER ORIFICE P090568 P090547 P090568 P090547
PILOT NAT. P500019
10 PILOT L.P.G. P500020
PILOT NAT. P322274
IOA
PILOT LP.G. P322275
11 THERMOCOUPLE P322391 P322391
12 ELECTRODE P322392 P322392 P322276 P322276
13 IGNITER BRACKET 7A189 7A189 7A189 7A189
14. VENT UMIT CONTROL P500406 P500406 P500406 P500406
15 THERMOSTAT P322016 P322016
16 WIRE ASSEMBLY P500409 P500409 P500409 P500409
17 MANUAL SPARK IGNITOR P285500 P285500 P285500 P285500
FOR PARTS ILLUSTRATION, SEE PAGE 18
NOTF._ Screws, bolts and washers are standard hardware Items and may be purchased locally
--19--
WILLIAMS GAS FIRED ROOM HEATER
REPLACEMENT PARTS
350, 500, & 650 MODEL SERIES
FOR PARTS LISTING (ENCLOSED CONSOLES)
SEE PAGE 21 (OR) 22
USE ONLY MANUFACTURERS ./_-.,._
AUTHORIZED PARTS __ NOTE:
ITEMS 24 AND 18 ARI_
NOT USED OR SUPPLIED WITH
WALL THERMOSTAT MODELS
>
_2o--
ENCLOSED CONSOLES
REPLACEMENT PARTS FOR
BUILT-IN THERMOSTAT MODELS
3501512 3501511 5001512 5001511 6501512 6501511
3501912 3501911 5001912 5001911 6501912 6501911
<EY DF_..SCRIP'IION 3501512 3501511 5001512 5001511 6501512 6501511
_10. 3501912 3501911 5001912 5001911 6501912 6501911
1 PANEL SIDE (R.H.) K000204 K000204- K000205 KC00205 K000206 K000206
2 NOT USED (OR PROVIDED)
,.3 INLET DUCT 'K7000.-6022 <7000-6022 K7000--6022 K7000-6022 K7000-6022 K7000-6022
#BoI"rOM LOUVER ASSY. iK000182-1 K000182-1 K000182-2 K000182-2 K000182-3 K000182-3
5CENTER PANEL K000220 K000220 K000221 K000221 K000222 K000222
6 BO'I'roM. CABINET KSOiX)-6003 K5000--6003 K5000-6OO4. K5000-6004 KSOOO.-601gK5000.-6019
7 PANEL SIDE (LH.) K000207 K000207 K000208 K000208 K000209 K000209
5 WIRE ASSEMBLY P50040g P500409 P500416 P5004.16 P500416 P500416
g TOP LOUVER ASSEMBLY K000181 K000181 K000212-1 K000212-1 K000212-2 K000212-2
10 COMBU_'_ION_ASSY. t<000242 K000242 1<000240 K000240 K00004.5 K00004.5
11 STEEL BURNER P50024.4- P50024.4 P50024.5 P50024.5 P500246 P500246
12 CABINET COVER ASSY. K000223 K000223 K000224 K000224 K000225 K000225
13 CONTROL BRACKET K000147 K000147 K000147 K000147 K000147 K000147
14 BURNER ORIFICE P500336 P500351 P500330 P500347 P500327 P500343
15 ORIRDE FIT'nNG P500086 P500056 P500086 P500086 P500086 P500086
16 MANIFOLD PIPE P500087 P500087 P500088 P500088 P500089 P50008g
17 GAS CONTROL VAL_,/E P5004.19 P500420 P5004.19 P500420 P500419 P5004.20
18 CONTROL ROD K000148-1 K000148-1 K000148-2 K000148-2 K000148-2 K000148-2
10 PILOT TUBE P012000 P012000 PO12000 P012000 PO12000 P012000
20 IGAB VALVE HEAT SHIELD KO00080 KO0008O KO00080 KO00080 KO00080 KO0008O
I
21 I SHIELD COVER K7m1-6030 K7011-6030 K7011-6031 K'7011-6031
22 1HERMOCOUPLE P321828 P321825 P321828 P321825 P322391 P322391
23 PILOT- BURNER P500019 P500020 P500019 P500020 P500019 P500020
24. TEMPERATURE DIAL P500126 P500126 P500126 P500126 P500126 P500126
25 VENT UMIT CONTROL P5004.72 P5004.72 P5004,06 P5004.06 P500118 P500118
26 HEAT SHIELD (REAR) K7003-83"/0 K7003-6370 K7003-6371 K7003-6371 K'/003-6372 K7(X)3-6372
27 BACI( PLA'I_ K000226 K000226 K000227 K000227 K000228 K000226
28 REAR CORNER BRACE K7003-6097 KT(X)3--6097 1(7003--6097 K7003.-6097 K7003-6097 K7003--60_17
"_NOT _,'10_1
NOTE: Screws, bolts and washers are standard hardware Items and may be purchased locally
FOR PARTS ILLUSTRA110N, SEE PAGE 20
--21--
ENCLOSED CONSOLES
REPLACEMENT PARTS FOR
WALL THERMOSTAT MODELS
3501522 3501521 5001522 5001521 6501522 6501521
3501922 3501921 5001922 5001921 6501922 6501921
KE_ DESCRIP'IION 3501522 3501521 5001522 5001521 6501522 6501521
NO. 3501922 3501921 5001922 5001921 6501922 6501921
1 PANEL SIDE (R.H.) K000204 K000204 K000205 K000205 K000206 K000206
2 ' THERMOSTAT P322016 P322016 P322016 P322016 P322016 P322016
3INLET DUCT K"/000-.6022 K7000.-6022 K7000-6022 K7000.-6022 K7000-6022 KT(XX)-6022
4 BOTTOM LOUVER ASSY. K000182-1 K000182-1 K000182-2 K000182-2 K000182-3 K000182-3
5CENTER PANEL K000220 K000220 K000221 K000221 K000222 K000222
6 i Bo'rroM, CABINET K5000-6003 K5000--6003 K5000-6004 K5000-6004 K5000-601111 K5000--6019
7 PANEL SIDE (LH.) K000207 K000207 K000208 K000208 K000209 KO0020g
8_RE AS_BLY P500409 P500409 P500416 P500416 P500416 P500416
g TOP LOUVER ASSEMBLY K000181 K000181 K000212-1 K000212-1 K000212-2 K000212-2
10 COMBUSTIONCl_ ASSY. K000242 K000242 K000240 K000240 K000045 K000045
11 STEEL BURNER P50024.4. P500244 P500245 P50024.,5 P50024.6 P500246
12 CABINET COVER ASSY. K000223 K000223 K000224 K000224 K000225 K000225
13 CONTROL BRACKET K000147 K000147 K000147 K000147 K000147 K000147
14. BURNER ORIFICE P500336 P500351 P500330 P500347 P500327 P500343
15 O_RCE FITI'ING P500086 P500086 P500086 P500086 PSOOOB6 P500086
16 MANIFOLD PIPE P500087 P500087 P500088 P500088 P500089 P500089
17 GAS CONTROL VALV1E P172100A P172200A P172100A P172200A P172100A P172200A
18 NOT USED (OR PROVIDED)
19 PILOT TUBE P012000 PO12000 P012000 P012000 P012000 P012000
20 GAS VALVE HEAT SHIELD KO00080 KO00080 KO00080 KO00080 KO00080 KO00080
21 SHIELD COVER K7011-6030 K7011-6030 KTO11-B031 1(7011-8031
22 NOT USED (OR PROVIDED)
23 PILOT - BURNER P322274 P322275 P322274 P322275 P322274 P322275
24 NOT USED (OR PROVIDED)
25 VENT UMIT CONTROL P,500472 P500472 P500406 P500406 P500118 P500118
26 HEAT SI-IIELD (REAR) ,K7003-6370 K7003-6370 K7003-6371 K7(X)3-6371 K7003-6372 KT(X)3-6372
27 BACK PLATE K000226 K000226 K000227 K000227 K000228 K000228
28 RF_ARCORNE_ BRACE K7003-80_ 1(7003-6(307 K7003-eOg7 K7003-60e7 K7003-60_ K7(X)3-60e7
"_ NOT _
NOTF_ Screws. bolts and woshers are etandard hardware Item= and may be purchased locally
FOR PARTS ILLUS'I1RA'nON, SEE PAGE 20
--22--
owners
manual
MODEL NOS.
FOR NAT. GAS ONLY
2001612; 2001622
3501512; 3501522
3501912; 3501922
5001512; 5001522
5001912; 5001922
6501512; 6501522
6501912; 6501922
MODEL NOS.
FOR L.RGAS ONLY
2001611; 2001621
3501511; 3501521
3501911; 3501921
5001511; 5001521
5001911; 5001921
6501511; 6501521
6501911; 6501921
Service Hints
If your heater fails to work right, you may avoid inconvenience and the cost
of a service call by checking the following points before you call for service.
FOR YOUR SAFETY FOR YOUR SAFETY
If you smell gas:
Do not store or use gasoline 1. Open windows.
or other flammable vapors and 2. Don't touch electrical.
liquids in the vicinity of this or any 3. Extinguish any open flame.
other appliance. 4. Immediately call your gas
supplier.
POSSIBLE CAUSE WHAT TO DO
If your heater Is not heating or not giving enough heat --
Thermostat is not set correctly. Reset thermostat to desired setting.
Pilot is out. Check pilot. Relight if necessary
following instructions for "Operating
Your Heater."
Pilot is on but burnerwon't
come on. If gas valve is set at other than "On"
heater will not operate. Shut heater
down and follow instructions for
relighting in "Operating Your Heater"
section.
Burner is not operating
properly.
Air flow restricted.
Pilot goes out time after time --
Heater flue blocked.
Check flame. If it is yellow the burner
is not getting enough air. Or if flame
is blue and noisy and seems to lift off
the burner, the burner is getting too
much air. See page 14.
Check that doors, drapes or furniture
are not blocking heater louvers.
Locatevent outletblockageand
clean.
If bumer is noisy --
Gas input amount is incorrect.
Too much primary air.
If blower does not run --
(if equipped)
Fan switch not set.
Blower not connected to
electric power.
If blower motor is noisy --
(if equipped)
Housing rattling.
Blower dirty.
Blower wheel bent.
Contact Williams Service Department.
Contact Williams Service Department.
Select fan speed.
Connectto electricpower.
Tighten screws.
Clean blower wheel.
Straighten or replace.
See troubleshooting section for more detailed information.
How to Order Repair Parts
When ordering repair parts, always give the following
information:
1. MODEL NUMBER
2. MFG. DATE CODE
3, PART NUMBER
4. PART DESCRIPTION
All parts listed herein may be ordered from your equip-
ment supplier.
The Model Number of your Williams room heater will be
found on the rating plate near gas valve, inside control
compartment.
WILLIAMS FURNACE COMPANY
225 Acacia Street
Colton, CA 92324 USA
(909) 825-0993
MANUFACTURED
IN THE U.S.A.
Established 1916
FAX: (909) 824-8009
©1998 The Williams Furnace Company Pdnted in U.S.A. Rev. 4/98 P500407