WISOL SFM10R2 Sigfox module User Manual

WISOL CO., LTD Sigfox module Users Manual

Users Manual

                                                                                                                                                                                            WISOL page 1 of 6    User manual of SFM10R2  1. Introduction The module  is a SIGFOX only module able to transmit and receive messages using the SIGFOX network.  The Sigfox chipset is from ON semiconductor, part number AX-SFUS-1-01.  2. Hardware Architecture:  2.1 Main Chipset Information Item Vendor Part Number Sigfox ON semiconductor AX-SFUS-1-01   2.2 Circuit Block Diagram The major internal and external block diagram of Module is illustrated in Figure 1-1.  Figure 1-1 Module block diagram and Interface
                                                                                                                                                                                            WISOL page 2 of 6     3. Operational Description This Module able to transmit and receive messages using the SIGFOX network. This module addresses the RCZ2 zone (North America).  - Features   > Sigfox up-link and down-link functionality controlled by AT commands > Temperature sensor > Ultra-low power consumption > High performance narrow-band Sigfox  - Time base of the RF frequency For Sigfox RF frequency, a TCXO(48MHz) is a clock reference.  - Transmission The Tx path produces a DBPSK-modulated signal. modulate RF signal generated by the synthesizer. The modulated RF signal is fed to the integrated RX/TX switch and antenna interface and then out of the AX-SFEU-1-01.  - Receiver The Rx path is able to receive 905.2MHz signal and the noise amplifier is built in the inside of the chip, it amplifies the received signal by the low noise amplifier according to the receiving intensity, and the amplified signal is converted into the digital signal through the ADC, Packets will be interpreted.
                                                                                                                                                                                            WISOL page 3 of 6     - Product Details  > Data Modulation  Sigfox : TX- DBPSK RX- 2GFSK  > Frequency :  Sigfox zone Uplink(TX) Downlink(RX) RCZ2(North America) 902.2MHz 905.2MHz
WISOL page 4 of 6 - Product Spec. Parameter Min Typ. Max Unit RF Characteristics RF Frequency Tx 902.2 MHz Rx 905.2 MHz Tx output power(at “24” setting) 22 24 dBm Frequency Error Tolerance(+25℃) -2.5 - +2.5 ppm 2nd Harmonics(conducted)- -44 dBm 3nd Harmonics(conducted)- -44 dBm Rx Sensitivity(@600bps, GFSK) -129 - dBm Rx Spurious Emission(30MHz~12.75GHz) -54 dBm - Product pwr Spec. Symbol Parameter Min Typ. Max Unit VDD Power supply 2.7 3.3 3.6 V Idd current - - 230 mA - Product Temp. Spec.       Symbol Parameter Rating Unit Temp Operating -30 to +85 ℃ TSTG Storage Temperature -40 to +125 ℃
                                                                                                                                                                                            WISOL page 5 of 6     4. Installation Guide  - Contents  - Installation Figure
WISOL page 6 of 6 5. Notice<Warning Statements>FCC Part 15.19 Statements:This device complies with Part 15 of the FCC Rules. Operation is subject to the following twoconditions: (1) this device may not cause harmful interference, and (2) this device mustaccept any interference received, including interference that may cause undesired operation.FCC Part 15.21 statementAny changes or modifications not expressly approved by the party responsible forcompliance could void the user's authority to operate this equipment.RF Exposure StatementThe antenna(s) must be installed such that a minimum separation distance of at least 20 cmis maintained between the radiator (antenna) and all persons at all times. This device mustnot be co-located or operating in conjunction with any other antenna or transmitter.End Product LabelingThe module is labeled with its own FCC ID. If the FCC ID is not visible when the module isinstalled inside another device, then the outside of the device into which the module isinstalled must also display a label referring to the enclosed module. In that case, the finalend product must be labeled in a visible area with the following:“Contains FCC ID: 2ABA2SFM10R2" Contains IC: 11534A-SFM10R2OEM Responsibilities to comply with FCC RegulationsThe module has been certified for integration into products only by OEM integrators underthe following condition:- The antenna(s) must be installed such that a minimum separation distance of at least 20cm is maintained between the radiator (antenna) and all persons at all times.- The transmitter module must not be co-located or operating in conjunction with any otherantenna or transmitter except in accordance with FCC multi-transmitter product procedures.As long as the two condition above is met, further transmitter testing will not be required.However, the OEM integrator is still responsible for testing their end-product for anyadditional compliance requirements required with this module installed (for example, digitaldevice emissions, PC peripheral requirements, etc.).IMPORTANT NOTE: In the event that these conditions can  ’  t be met (for certainconfigurations or co-location with another transmitter), then the FCC authorization is nolonger considered valid and the FCC ID can’t be used on the final product. In thesecircumstances, the OEM integrator will be responsible for re-evaluating the end product(including the transmitter) and obtaining a separate FCC authorization.Manual Information To the End UserThe OEM integrator has to be aware not to provide information to the end user regardinghow to install or remove this RF module or change RF related parameters in the usermanual of the end product.
WISOL  page 6 of 6 l'exposition aux RF L’antenne  (ou  les antennes)  doit  être installée  de  façon à  maintenir à  tout instant  une distance minimum de au moins 20 cm entre la source de radiation (l’antenne) et toute personne physique. Étiquetage du produit final  Le module BT111 est étiqueté avec sa propre identification FCC et son propre numéro de certification IC. Si l’identification FCC et le numéro de certification IC ne sont pas visibles lorsque le module est installé à l’intérieur d’un autre dispositif, la partie externe du dispositif dans lequel le module est installé devra également présenter une étiquette faisant référence au module inclus. Dans ce cas, le produit final devra être étiqueté sur une zone visible avec les informations suivantes : « Contient module émetteur identification FCC ID : 2ABA2SFM10R2 « Contient module émetteur IC : 11534A-SFM10R2RSS-GEN, Sec. 8.3 This radio transmitter (identify the device by certification number, or model number if Category II) has been approved by Industry Canada to operate with the antenna types listed below with the maximum  permissible  gain  and  required  antenna  impedance  for  each  antenna  type  indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Le présent émetteur radio (identifier le dispositif par son numéro de certification ou son numéro de modèle s’il fait partie du matériel de catégorie I) a été approuvé par Industrie  Canada pour fonctionner avec les types d’antenne énumérés ci-dessous et ayant un gain admissible maximal et l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur.